PD _Lorad Xray System.docx
DOCX document 22 KB Posted
- Attached to
- Sole Source - Lorad X-ray System Procurement Federal contract opportunity
- Solicitation number
- FA8227-23-Q-XRAY
About this file
This document provides product specifications for a Spellman/Lorad 160kV air cooled x-ray system procurement by the 709th Maintenance Support Squadron at Hill Air Force Base. The specifications call for one Spellman/Lorad LPX-160 portable industrial x-ray unit to meet NDI workload requirements. The unit must automatically adapt to input line voltages of 100-130Vac or 200-250Vac and include a control unit, tubehead assembly, cables, transit cases, manual, and air cooled laser pointer adapter. Delivery is required to Hill AFB by the specified contracting officer. The contractor must also provide a standard commercial warranty for the x-ray system.
The related federal contract opportunity is a sole source procurement solicitation issued by the Air Force Sustainment Center to acquire the Spellman/Lorad x-ray system according to the product description and specifications.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation_Lorad Xray System.docx | DOCX document | |
| SSJ _Lorad Xray System.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S Air Force Product Description and Specifications for Spellman/Lorad 160kV Air Cooled X-Ray System
POC: Rand Bagley 8/16/2023
Description and Specifications for Spellman/Lorad 160kV Air Cooled System
709 Maintenance Support Squadron (MXSS) has a need for the purchase/replacement of a Spellman/Lorad model #3-000-0727 Lorad 160kV air cooled system, to meet the needs of their NDI X-Ray workload requirements in support of 309 Maintenance Support Group (MXSG) and Ogden Air Logistic Complex (OO-ALC). Item is specified in Air Force technical order (AFTO) 33B-1-1 paragraphs 6.3.5 and 6.3.5.1.
1 Each Spellman/Lorad LPX-160 Portable Industrial X-ray Unit NSN #3-000-0727 Automatically adapts to input line voltage 100-130Vac, 50/60Hz, 20 Amperes maximum 200-250Vac, 50/60Hz, 10 Amperes maximum May also be portable-generator powered
X-Ray Output:
5 to 160kV, 0.1 to 5.0mA Constant potential, end-grounded anode
Design Type – Portable Tube Cooling Method – Air Included Items
| Control unit |
| Tubehead assembly |
| Control cable |
| Power cable |
| Fan cable |
| Laser printer |
| Air cooled laser pointer adapter |
| Tubehead transit case |
| Control unit transit case |
| Cable transit case |
| Manual/laser pointer/adapter/aircooled supplement transit case |
Delivery:
The contractor shall deliver the equipment to the following address located at Hill Air Force Base:
709 MXSS
Attn: Morgan Neilson (801)586-6009 5832 H Ave.
Bldg. 843 Bay J Hill AFB UT.
84056
Warranty:
The contractor shall provide a standard commercial warranty.
File details come from the government source that posted it. Updated .