Updated_Questions_and_Answers_for_FA813219Q0053.pdf

PDF 86 KB Posted

Attached to
CNC Mill; Extend Response Date Federal contract opportunity
Solicitation number
FA8132-19-Q-0053
Issued by
Department of the Air Force Materiel Command

About this file

Additional question and answer (Question #7 on attached PDF)

View the file

Other files for this federal contract opportunity

Other files attached to CNC Mill; Extend Response Date, newest first.
File Type Posted
FA8132-19-Q-0053_Amendment_2,_CNC_Mill.pdf PDF
Questions_and_Answers_for_FA813219Q0053.pdf PDF
FA8132-19-Q-0053_Amendment_1,_CNC_Mill.pdf PDF
FA8132-19-Q-0053,_SOW,_CNC_Mill_-_Rev_05.23.2019.pdf PDF
FA8132-19-Q-0053,_CNC_Mill.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers for FA8132-19-Q-0053; CNC Mill

1) Please clarify what the term "installation" means.

• Installation includes plugging in the machine and attaching any parts and components that complete the machine and are included with this requirement

2) Will the Government off load and place the machine in the place of operation ?

• Upon delivery, the government shall off load and place the machine in the place of operation

3) Will the Government supply electrical power to the machine as well as air ?

• The government will supply electrical power within twenty feet of the machine’s place of operation

4) In reference to Item 2.1 of the solicitation, it states “Shall include offline programming software including support hardware” – What will the software be used for?

• The Government prefers CAD to CAM (CAD to G Code) Software

5) Does it require a UL inspection?

• Yes, UL inspection is required

6) Does the milling machine require UL electrics?

• Yes

7) I need to know if the Power we will be hooking up to is - 480VOLT/3-PH/60HZ or 240VOLT/3-

PH/60HZ?

• For the location that the machine will be operating in can provide 480V but both 480v or 240V will work.

File details come from the government source that posted it.