DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)

TINKER AIR FORCE BASE OKLAHOMA

Commodity Item Description

MAUS SYSTEM

The 76 AMXG requires the purchase of one (1) complete Mobile Automated System (MAUS) with the following specifications:

• 1 EA - P/N 10-95-A21 - Noun: MAUS V, Chassis/Computer.

All Inspection Modes, Pulse-echo, Bond test, and Eddy current, Includes a ruggedized laptop with MAUS REV 3.0 and ImagIn software. PCI express chassis to computer interface, and WIN 7 OS, Including MAUS Card Cage to computer power cables and the PCI Express interface cable

• 1 EA - P/N MAUS-DR-11.1

Variable Stroke Scanner and Track Assembly Kit.

To include: X-Y scanner, Scanner Drive Carriage, Sensor holders, Scan arm extension offset bracket Assy. 2 flexible track sections, Track vacuum system, Sensor Cables, and a scanner Control Cable all in a storm case with custom cut foamCable).

• 1 EA - P/N MAUS-A3 MAUS, PE Ultrasonic Sensor Set:

To include 5MHz standard, 2.25, 10 and 15 MHz selections available, (4 transducers Total), Includes 10-510-C228 sensor cable 14" long (set of 4), and 1 set of 4 each, 10-49-A21 Sensor Sleeves..

• 1 EA P/N MAUS-A4 270/320 KHz set

To include Resonance Sensor Set: 270kHz and 320kHz (Qty 2) standard, Including coesponding transducer holders and coaxial cables

• 1 EA P/N MAUS-A5 , MAUS Eddy Current Sensor Set To include: Includes 2 sensors of your frequency choice. 500 - 10 kHz standard including NDTS Shielded Sensor cable & two each SPC-292-SH Eddy current sensor holders.