DEPARTMENT OF THE AIR FORCE
OKLAHOMA CITY AIR LOGISTICS COMPLEX
TINKER AIR FORCE BASE OKLAHOMA
1 July 2019
MEMORANDUM FOR RECORD
SUBJECT: Item Description, A19-078 KC-46 Explosion Proof Pressure Washer
1. The 76th AMXG is requesting utilization of funds for the purchase of Explosion Proof Pressure Washers.
2. The requested equipment item specifications are outlined below.
a) Fourteen (14) each Explosion Proof Pressure Washers (Sioux Model EN5.0H3000-60XP or Equivalent)
1. Hot/cold power washer
2. Shall meet a minimum of 5.0 GPM at 3000 PSI during use
3. Shall be equipped with a minimum of 10 HP motor
4. Shall have adjustable pressure
5. Shall include a minimum of three (3) wash tips for angles of 0, 15, and 25 degrees
6. Shall be a minimum of 60 Hz - Hot/Cold Pressure Washer
7. Item shall have a high temperature limit switch
8. Item shall have a pressure relief valve
9. Item shall have a high pressure rupture disc
10. Item shall have a water flow switch
11. Item shall have a minimum 50’ discharge hose
12. Shall have a Glycerin-filled pressure gauge
13. Item shall have a Detergent injector or Metering valve
14. Item shall be equipped with an Internal circuit breaker on units operating on 480 volts or less
15. Shall meet OSHA regulation 1910.303(a) standards requiring electrical equipment to be third-party certified for safety by a Nationally Recognized Testing Laboratory
16. Shall meet UL 1776, standard for safety for high-pressure cleaning machines
17. Shall meet CSA C 22.2 #68, standard for safety for commercial/industrial pressure washers and steam cleaners
18. Shall meet National Electric Code (NEC) and Canadian Electric Code (CEC)
19. Shall be Cleaning Equipment Trade Association (CETA) Performance Certified
20. Shall meet UL 1203, standard for explosion-proof and dust-ignition-proof electrical equipment.
21. Shall meet CSA C22.2 #30, standard for explosion-proof enclosures in Class I hazardous locations.
22. Shall meet CSA C22.2 #25, standard for explosion-proof enclosures in Class II, E, F, and G hazardous locations
OC-ALC OBCA 2
SUBJECT: Item Description, A19-078 KC-46 Explosion Proof Pressure Washer
3. Point of contact for this memorandum is Monica Callaway at (405) 622-7847 or e-mail at monica.callaway@us.af.mil.
Monica J. Callaway Program Management Specialist
OC-ALC OBCA