A19-078_KC-46_Explosion_Proof_Pressure_Washer_-_Item_Description.pdf

PDF 62 KB Posted

Attached to
Explosion Proof Pressure Washer Federal contract opportunity
Solicitation number
FA8125-19-Q-A071
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Tinker Air Force Base

About this file

Item Description for explosion proof pressure washer

View the file

Other files for this federal contract opportunity

Other files attached to Explosion Proof Pressure Washer, newest first.
File Type Posted
Combo_Synopsis-Solicitation_KC46.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX

TINKER AIR FORCE BASE OKLAHOMA

1 July 2019

MEMORANDUM FOR RECORD

SUBJECT: Item Description, A19-078 KC-46 Explosion Proof Pressure Washer

1. The 76th AMXG is requesting utilization of funds for the purchase of Explosion Proof Pressure Washers.

2. The requested equipment item specifications are outlined below.

a) Fourteen (14) each Explosion Proof Pressure Washers (Sioux Model EN5.0H3000-60XP or Equivalent)

1. Hot/cold power washer

2. Shall meet a minimum of 5.0 GPM at 3000 PSI during use

3. Shall be equipped with a minimum of 10 HP motor

4. Shall have adjustable pressure

5. Shall include a minimum of three (3) wash tips for angles of 0, 15, and 25 degrees

6. Shall be a minimum of 60 Hz - Hot/Cold Pressure Washer

7. Item shall have a high temperature limit switch

8. Item shall have a pressure relief valve

9. Item shall have a high pressure rupture disc

10. Item shall have a water flow switch

11. Item shall have a minimum 50’ discharge hose

12. Shall have a Glycerin-filled pressure gauge

13. Item shall have a Detergent injector or Metering valve

14. Item shall be equipped with an Internal circuit breaker on units operating on 480 volts or less

15. Shall meet OSHA regulation 1910.303(a) standards requiring electrical equipment to be third-party certified for safety by a Nationally Recognized Testing Laboratory

16. Shall meet UL 1776, standard for safety for high-pressure cleaning machines

17. Shall meet CSA C 22.2 #68, standard for safety for commercial/industrial pressure washers and steam cleaners

18. Shall meet National Electric Code (NEC) and Canadian Electric Code (CEC)

19. Shall be Cleaning Equipment Trade Association (CETA) Performance Certified

20. Shall meet UL 1203, standard for explosion-proof and dust-ignition-proof electrical equipment.

21. Shall meet CSA C22.2 #30, standard for explosion-proof enclosures in Class I hazardous locations.

22. Shall meet CSA C22.2 #25, standard for explosion-proof enclosures in Class II, E, F, and G hazardous locations

OC-ALC OBCA 2

SUBJECT: Item Description, A19-078 KC-46 Explosion Proof Pressure Washer

3. Point of contact for this memorandum is Monica Callaway at (405) 622-7847 or e-mail at monica.callaway@us.af.mil.

Monica J. Callaway Program Management Specialist

OC-ALC OBCA

File details come from the government source that posted it.