DEPARTMENT OF THE AIR FORCE

OKLAHOMA CITY AIR LOGISTICS COMPLEX (OC-ALC)

TINKER AIR FORCE BASE OKLAHOMA

ITEM DESCRIPTION

GROUND POWER UNITS

1) AMXG requires the purchase of five (5) each Hobart Ground Power Units (Brand Name or Equivalent) capable of meeting the following specifications:

o 5 Each ITW GSE Model 2400 Solid State Frequency Converter, Type ID 3GWH-200/260‐N Part Number:

90SX240H (Brand Name or Equivalent)

Units shall have mounted Horizontal Unit trailer

INPUT: Units shall have a minimum of 480VAC +/-10%, 50-60Hz +/-10%

AC OUTPUT: Units shall have a minimum of 90kVA, 400Hz, 3x115/200VAC (93A PF0.8 / 117A

PF1), 400% Overload, Units shall have integrated Line Drop Compensation (LDC) capability to a minimum of 400ft, Plus without additional permanent components/products.

Units shall have a Plug & Play voltage regulation.

Total size of units to include trailer shall not exceed: 40” Wide x 40” Long x 50” Height.

Units shall have a Neutral Conductor rupture supervision.

Units shall have a Wall flush mount/accessible from front for periodic maintenance.

Units shall have an input power disconnect switch.

o 5 Each units shall comply with Military Interlock - E&F interlock functions added per Mil-STD 704F Part

Number - AP-578817 (Brand Name or Equivalent) o 5 Each Trailer, Heavy Duty Assembly with brake and front steering - Part Number - 292180 (Brand Name or Equivalent) o Shall be FAA certified

2) The Contractor shall provide a warranty of at least five (5) years for each ground power unit.

3) 5 Each - ETL Listed. Units shall have a minimum of 400Hz, 50ft, single jacketed AC power cable assembly with Therm gard protection , NSN supported and standard for all ITW 400Hz cable assemblies Part Number:

JB8816-50NJ (Brand Name or Equivalent)

4) 5 Each - Units shall have a minimum of 60Hz, #1 4-pronged conductor, minimum of 40' long input cable 143A rated, Anixter 5B-0104C O.D. 1.68" Part Number: 080634 (Brand Name or Equivalent)

5) Training - Contractor shall provide at least One (1) full business day of operator training In Accordance With

(IAW) the Item Description and Statement of Work (SOW) for the requested Hobart Ground Power Units

(Brand Name or Equivalent) ITW GSE Model 2400. Training will be for a minimum of four (4) Government employees. Operator training shall include but is not limited to cover training on maintenance, troubleshooting, remedial and preventive maintenance (RM/PM) cycles of the units. Training shall be provided at Building 2136

Room 112, Dock 2, Post Location B-11 at Tinker AFB, Oklahoma.