ATTACH__8_-_Environmental_Survey_B-732_Final_Report.pdf
PDF 9 MB Posted
- Attached to
- Renovate Squad OPS Facility, Building 732 Federal contract opportunity
- Solicitation number
- FA670318B0001
About this file
ATTACH #8 - Environmental Survey_B-732 Final Report
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| AWARD_SYNOPSIS.pdf | ||
| ATTACH__7_-_CEC_Use___Registry_of_01560_submittals_include_with_01560_spec.xlsx | XLSX spreadsheet | |
| AMENDMENT_2.pdf | ||
| ATTACH__9_-_2017-1276-005_Dobbins_ARB_Preliminary.pdf | ||
| ATTACH__2_-_Ammendment_1_-_Answer_Questions_1.pdf | ||
| ATTACH__14_-_DARBDesignGuideAug2011.pdf | ||
| Amendment_1.pdf | ||
| Site_Visit_Sgn-In_Sheet.pdf | ||
| Wage_Determination_1.pdf | ||
| Final_Combined_Drawing_Set.pdf | ||
| Attachment_4_Financial.pdf | ||
| FA670318B0001.pdf | ||
| Attachemnt_6_DARB_4.pdf | ||
| _Final_Combined_Specs_Double_Sided.pdf | ||
| Attachment_5_DARB3.pdf |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Dobbins ARB Building 732 DEC Project No. 1603.002
SURVEY
FOR ASBESTOS AND LEAD-BASED PAINT
RENOVATE BUILDING 732 SQUAD OPS
DOBBINS AIR RESERVE BASE
MARIETTA, GEORGIA
Prepared for:
TOLAND MIZELL MOLNAR, LLC
590 MEANS STREET NW, SUITE 200
ATLANTA, GEORGIA 30318
Report Date:
March 28, 2016
Prepared by:
DURBIN ENVIRONMENTAL CONSULTANTS, INC.
3461 LAWRENCEVILLE-SUWANEE ROAD, SUITE A
SUWANEE, GEORGIA 30024
(678) 482-9917
SOLICITATION: FA670318B0001
RENOVATE SQUAD OPS FACILITY, BLDG. 732
ATTACHMENT #8
TABLE OF CONTENTS
PAGE
1. INTRODUCTION 3
2. DISCUSSION AND RESULTS 3
a. Asbestos
b. Lead
c. PCBs/Fluorescent Lights
3. METHODOLOGY 5
4. OBSERVATIONS/CONCLUSIONS 7
5. RECOMMENDATIONS 8
6. REFERENCES 8
APPENDIX
A. Asbestos Bulk Sampling Summary followed by the Laboratory Report and
Representative Photographs of Suspect Asbestos Containing Materials
B. Paint Chip Sample Summary followed by the Laboratory Data and Photographs of Paint
Chip Samples
1. INTRODUCTION
Durbin Environmental Consultants, Inc. (DEC) was retained by Toland Mizell Molnar, LLC, to conduct a hazardous material assessment for suspect asbestos containing materials and lead-based paint at Building 732, Dobbins Air Reserve Base (ARB), Marietta, Georgia, in support of the Renovate Building 732 Squad Ops Project. Michael F. Durbin, CIH of Durbin
Environmental Consultants, Inc. conducted the hazardous material assessment on March 2, 2016.
Mr. Durbin is currently accredited as an asbestos inspector through an Environmental Protection
Agency (EPA) approved training provider.
Bulk sample analysis for suspect asbestos containing materials was performed by Analytical
Environmental Services, Inc., 3080 Presidential Drive, Atlanta, Georgia 30340. Analytical
Environmental Services Inc. is accredited for asbestos fiber analysis through participation in the
National Institute of Standards and Technology (NIST) National Voluntary Laboratory
Accreditation Program (NVLAP) and is assigned NVLAP Lab Code 102082-0. Analytical
Environmental Services Inc. utilized the analytical method: EPA/600/R-93/116: "Method for the Determination of Asbestos in Bulk Building Materials” (polarized light microscopy in conjunction with dispersion staining).
Paint Chip Sample analysis was performed via Flame Atomic Absorption Spectroscopy (AAS) by Analytical Environmental Services, Inc. (AES), 3080 Presidential Drive, Atlanta, GA 30340.
AES is accredited in the analysis of lead-based paint (LBP) samples via the Environmental Lead
Laboratory Accreditation Program (#100671).
2. DISCUSSION AND RESULTS
a. Building 732 - Asbestos
The asbestos survey was conducted in accordance with the sampling protocol established in the
Environmental Protection Agency’s Asbestos Hazard Emergency Response Act (AHERA 40
CFR, Part 763) for the materials included in this specific survey (roofing materials were not included as part of this survey). The following provides general information and summarizes the potential impact of asbestos containing material during any scheduled renovation project.
Bulk samples were collected from the following suspect asbestos containing materials during this survey:
1. Blue Carpet Adhesive (HM #1)
2. Blue Covebase and Associated Adhesive (HM #2)
3. Beige Covebase and Associated Adhesive (HM #3)
4. Ceramic Tile (HM #4)
5. Ceiling Tile – 2’ X 2’ Smooth White (HM #5)
6. Ceiling Tile – 2’ X 2’ White with Small Fissures, Gouges and Pinholes (HM #6)
7. Duct Mastic on Foil Duct - White (HM #7)
8. Drywall and Joint Compound (HM #8)
9. Exterior Wall BATT Insulation (HM #9)
10. 12” X 12” Floor Tile and Associated Mastic, Glue, Adhesive – Beige Mottled (HM #10)
11. Grey Sink Mastic (HM #11)
12. Pipe Insulation – Paper Wrapped with Fiberglass (HM #12)
None of the collected bulk sample materials contained asbestos by Polarized Light Microscopy
(PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the
Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
All samples collected were determined to be non-asbestos by Polarized Light Microscopy
(PLM).
b. Building 732 - Lead
Paint chip samples were collected from the following locations:
1. Beige Paint on Metal Door, Basement, Room 102, Janitor’s Closet (Sample # 732-PC-01)
2. Beige Paint on Metal Door Frame, Basement, Room 102, Janitor’s Closet (Sample # 732-PC-
02)
3. Beige Paint on Metal Structural Column, Basement, Near Bar Area (Sample # 732-PC-03)
4. Beige Paint on Metal Structural Column, 1st Floor, Room 1238, Janitor’s Closet (Sample #
732-PC-04)
5. Beige Paint on CMU Block Wall, 1st Floor, Room 1238, Janitor’s Closet (Sample # 732-PC-
05)
All of the painted surfaces sampled at Building 732 were less than 0.5% lead by weight via
Flame Atomic Absorption Spectrophotometry. One sample (732-PC-04) had detectable levels of lead via Flame Atomic Absorption Spectrophotometry.
Note: Disturbance to any painted item/surface/component shall be done in compliance with the
OSHA Construction Industry Standard for Lead (29 CFR 1926.62). The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR
1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the
Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain some detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an
8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Refer to Appendix B for the Paint Chip Sample Summary followed by Laboratory Data and
Representative Photographs of Paint Chip Samples.
c. Building 732 – PCBs/Fluorescent Lights
The construction date of Building 732 was not known at the time of the survey. All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
Additionally, the fluorescent lights and high intensity discharge bulbs (HID) should be assumed to contain mercury.
All mercury vapor light fixtures should be handled in accordance with 40 CFR Part 273
Standards for Universal Waste Management.
3. METHODOLOGY
Asbestos Sampling Protocol
The inspector sampled all suspect ACM in accessible areas. In order for a group of homogeneous materials to be considered as non asbestos containing, all samples from that specific homogeneous material must be analyzed and determined to be non asbestos containing or less than or equal to 1% asbestos.
Representative, randomly selected samples were collected from each homogeneous area of suspect asbestos-containing material. For purposes of this report, the homogeneous area is physically defined as all material with the same visual appearance, texture and hardness.
The minimum number of samples collected for each homogeneous area (or material) is as follows:
1. Friable Spray-applied or Trowel-applied Material
a. Less than or equal to 1000 square feet (S.F.) = 3 samples
b. Greater than 1000 S.F. and less than or equal to 5000 S.F. = 5 samples.
c. Greater than 5000 S. F. = 7 samples
2. Pipe and Duct Insulation
Three samples per homogeneous area of insulation were taken unless it was a confirmation sample.
3. Elbows, Valves, Fittings and Connection Mud
Three representative samples were taken from each representative type of insulated elbow, valve, fitting and connecting mud unless it was a confirmation sample.
4. Boiler, Tanks and Furnaces
A minimum of 3 samples per unit was collected.
5. Patchwork
Patchwork is defined as a patch or repair to existing material based on the following quantities:
a. Surfacing material patches are limited to a maximum of 6 S. F.
b. Pipe and duct insulation patches are limited to a maximum of 6 L. F. or 6
S. F.
c. Boiler, tanks and furnace patches are limited to 6 S.F. maximum.
If the patchwork exceeded the limits prescribed above, the sampling protocol resorted back to the homogeneous area descriptions in items 1-4. If a material qualifies as patchwork, a single sample was collected per patch.
6. Ceiling or Acoustical Tile
a. Minimum of 2 Samples
7. Miscellaneous Friable Material (INCLUDED DRYWALL & JOINT
COMPOUND)
a. 3 Samples
8. Non-friable Material
Non-friable materials for purposes of this survey would include material such as floor tiles and mastic/adhesive, linoleum floor covering, interior/exterior caulks, flooring felt (if still under floor tile), roofing materials, miscellaneous cementitious material such as wall or ceiling panels, caulking or sealant, or window glazing.
a. Minimum of 2 samples
Lead-Based Paint (LBP) Sampling Protocol
Paint chips containing lead concentrations at or above 0.5 percent by weight are considered positive for lead based on EPA and Department of Housing and Urban Development (HUD) guidelines for Target Housing and Child Occupied Facilities.
The inspector collected paint chip samples from representative surfaces and components likely to be impacted by any renovation project and compared them against the HUD definition for Lead-
Based Paint (LBP) of 0.5 % by weight. Individual sample results are presented in tabular form in Appendix B.
The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for
Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead
Standard. OSHA 29 CFR 1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain some detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an 8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
4. OBSERVATIONS/CONCLUSIONS
Building 732 - Asbestos
None of the collected bulk sample materials contained asbestos by Polarized Light Microscopy
(PLM) (reference Appendix A for the Asbestos Bulk Sampling Summary followed by the
Laboratory Report and Representative Photographs of Suspect Asbestos Containing Materials).
All samples collected were determined to be non-asbestos by Polarized Light Microscopy
(PLM).
Building 732 - Lead
All of the painted surfaces sampled at Building 732 were less than 0.5% lead by weight via
Flame Atomic Absorption Spectrophotometry. One sample (732-PC-04) had detectable levels of lead via Flame Atomic Absorption Spectrophotometry.
Note: Disturbance to any painted item/surface/component shall be done in compliance with the
OSHA Construction Industry Standard for Lead (29 CFR 1926.62). The Occupational Safety and Health Administration (OSHA) Construction Industry Standard for Lead (29 CFR 1926.62) does not reference the HUD definition for LBP. If detectable levels of lead are identified in any painted surface, paint disturbance will fall under the OSHA Lead Standard. OSHA 29 CFR
1926.62 requires employers to perform exposure monitoring for employees whose tasks disturb or potentially disturb lead. The data contained in this survey report should be provided to the
Contractor, prior to the Contractor submitting bids for maintenance, renovation or demolition work. The Contractor shall assume that all painted surfaces may contain some detectable levels of lead for purposes of this project and demonstrate through personal air sampling that airborne lead levels will not exceed 30 micrograms (ug) lead per cubic meter (m3) of air determined as an
8-hour time-weighted average (TWA), for each representative task and trade that disturbs painted surfaces.
Refer to Appendix B for the Paint Chip Sample Summary followed by Laboratory Data and
Representative Photographs of Paint Chip Samples.
Building 732 – PCBs/Fluorescent Lights
The construction date of Building 732 was not known at the time of the survey. All ballasts installed or manufactured prior to 1978, should be assumed to contain PCBs unless specifically labeled as having no PCBs.
Additionally, the fluorescent lights and high intensity discharge bulbs (HID) should be assumed to contain mercury.
All mercury vapor light fixtures should be handled in accordance with 40 CFR Part 273
Standards for Universal Waste Management.
5. RECOMMENDATIONS
A. The asbestos containing material survey report should be maintained at the job site during performance of the construction activities.
B. Disturbance of painted surfaces should be performed in accordance with the OSHA Lead
Standard (29 CFR 1926.62). Waste generated by disturbance of painted surfaces should be subjected to Toxicity Characteristic Leaching Procedure (TCLP) testing to determine leachable lead concentrations. If leachable concentrations of lead in construction waste are determined by TCLP testing, those materials should be disposed of in accordance with 40
CFR Part 260 to 271.
C. Remove and dispose of all PCB ballasts in accordance with 40 CFR Part 761 Polychlorinated
Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use
Prohibitions, and other applicable Federal, State and Local Regulations. Note: Based on major renovation projects it appears that the ballasts were post 1978 and the ballast observed were labeled “No PCBs” or “PCB Free”.
D. Remove and dispose of (or recycle) all mercury vapor light fixtures in accordance with 40
CFR Part 273 Standards for Universal Waste Management and other applicable Federal, State and Local Regulations.
6. REFERENCES
1. Guidance for Controlling Asbestos-Containing Materials in Buildings”
(Purple Book). EPA 560/5-85-024. Office of Pesticides and Toxic Substances
Washington, DC 20460.
2. 40 CFR, Part 763, Asbestos Hazard Emergency Response Act
3. 40 CFR, Part 763, Asbestos School Hazard Abatement Reauthorization Act
4. 40 CFR, Part 61, Subpart M Asbestos
5. 29 CFR Part 1926.1101 Asbestos
6. 29 CFR Part 1926.62 Lead
7. HUD Guidelines for the Evaluation and Control of Lead-Based Paint Hazards in Housing
(Most recent issue)
8. 40 CFR Part 260 General Hazardous Waste Management.
9. 40 CFR Part 261 Identification and Listing of Hazardous Waste.
10. 40 CFR Part 262 Standards Applicable to Generators of Hazardous Waste.
11. 40 CFR Part 263 Standards Applicable to Transporters of Hazardous Waste.
12. 40 CFR Part 268 Land Disposal Restrictions.
13. 40 CFR Part 761 Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions.
14. 40 CFR Part 273 Standards for Universal Waste Management
If you have any questions or comments regarding this report, please do not hesitate to call.
Sincerely, Durbin Environmental Consultants, Inc.
Sellers C. Carmack Sellers C. Carmack
Vice President
Michael F. Durbin, CIH Michael F. Durbin, CIH
President
APPENDIX A
Asbestos Bulk Sampling Summary
Followed By the Laboratory Data and Representative Photographs of Suspect Asbestos Containing Materials
Sample
Number Description Asbestos
Present Friable Non-
Asbestos
Material
Present
Sample
Location
HM
732-CA-01 Blue Carpet
Adhesive NAD N/A See Lab
Report Corridor 1208
732-CA-02 Blue Carpet
Adhesive NAD N/A See Lab
Report Room 1217.1, Aircraft Briefing
Room
732-CA-03 Blue Carpet
Adhesive NAD N/A See Lab
Report Room 1237
732-CB1-01
Blue Covebase and
Associated
Adhesive NAD N/A See Lab
Report Corridor Outside
Stair 1218
732-CB1-02
Blue Covebase and
Associated
Adhesive
NAD N/A See Lab
Report Room 1217.1, Aircraft Briefing
Room
732-CB1-03
Blue Covebase and
Associated
Adhesive
NAD N/A See Lab
Report Room 1238, Janitor’s Room
732-CB2-01
Beige
Covebase and
Associated
Adhesive
NAD N/A See Lab
Report Room 1209, Chief
Pilot
732-CB2-02
Beige
Covebase and
Associated
Adhesive
NAD N/A See Lab
Report Room 1224, Break
Room 3
732-CB2-03
Beige
Covebase and
Associated
Adhesive
NAD N/A See Lab
Report Room 1225, New
Gear Lockers
Description Asbestos
Present Friable Non-
Asbestos
Material
Present
Sample
Location
HM
732-CER-01 Ceramic Tile NAD N/A See Lab
Report
Basement, Men’s
Restroom, Floor
732-CER-02 Ceramic Tile NAD N/A See Lab
Report
Basement, Men’s
Restroom, Wall
732-CER-03 Ceramic Tile NAD N/A See Lab
Report
Basement, Women’s
Restroom, Floor
732-CT1-01
Ceiling Tile –
2’ X 2’
Smooth White
NAD N/A
See Lab
Report
Room 1222, Navigator’s Work
Room
732-CT1-02
2’ X 2’
Smooth White
NAD N/A
See Lab
Report Room 1212, Pilot 5
732-CT1-03
Ceiling Tile –
2’ X 2’
Smooth White
NAD N/A
See Lab
Report Corridor 1248
732-CT2-01
Ceiling Tile –
2’ X 2’ White with Small
Fissures, Gouges and
Pinholes
NAD N/A
See Lab
Report
Room 1238, Janitor’s Room
732-CT2-02
2’ X 2’ White with Small
Fissures, Gouges and
Pinholes
NAD N/A
See Lab
Report Room 1232 6
732-CT2-03
Ceiling Tile –
2’ X 2’ White with Small
Fissures, Gouges and
Pinholes
NAD N/A
See Lab
Report Room 1229
Description Asbestos
Present Friable Non-
Asbestos
Material
Present
Sample
Location
HM
732-CT2-04
Ceiling Tile –
2’ X 2’ White with Small
Fissures, Gouges and
Pinholes
NAD N/A
See Lab
Report
Room 1220, Comm
732-CT2-05
2’ X 2’ White with Small
Fissures, Gouges and
Pinholes
NAD N/A
See Lab
Report
Room 1252, Training
Classroom
732-DM1-01
Duct Mastic on Foil Duct -
White
NAD N/A
See Lab
Report Room 1229
732-DM1-02
Duct Mastic on Foil Duct -
White
NAD N/A
See Lab
Report
Room 1222, Navigator Work
Room
732-DM1-03
Duct Mastic on Foil Duct -
White
NAD N/A
See Lab
Report Corridor 1211
732-DWJC-
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1214, General Storage
732-DWJC-
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1224, Breakroom
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1217.1, Aircrew Briefing
Room
732-DWJC-
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Corridor 1248, Outside OPS
Office Room 1239
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1232, Loadmaster
Workroom
Description Asbestos
Present Friable Non-
Asbestos
Material
Present
Sample
Location
HM
732-DWJC-
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1237.2, Record Data
Management
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1237.2, Record Data
Management
732-DWJC-
Drywall and
Joint
Compound
NAD N/A
See Lab
Report
Room 1237.2, Record Data
Management
732-EWB-01
Exterior Wall
BATT
Insulation
NAD N/A
See Lab
Report
Room 1221, Chief
Navigator
732-EWB-02
Exterior Wall
BATT
Insulation
NAD N/A
See Lab
Report
Room 1222, Navigator Work
Room
732-EWB-03
Exterior Wall
BATT
Insulation
NAD N/A
See Lab
Report
Room 1222, Navigator Work
Room
732-FT1-01
12” X 12”
Floor Tile and
Associated
Mastic, Glue, Adhesive –
Beige Mottled
NAD N/A
See Lab
Report
732-FT1-02
Floor Tile and
Associated
Mastic, Glue, Adhesive –
Beige Mottled
NAD N/A
See Lab
Vestibule 1201 10
Description Asbestos
Present Friable Non-
Asbestos
Material
Present
Sample
Location
HM
732-FT1-03
12” X 12”
Floor Tile and
Associated
Mastic, Glue, Adhesive –
Beige Mottled
NAD N/A
See Lab
Report
Room 1225, New
Gear Lockers
732-FT1-04
Floor Tile and
Associated
Mastic, Glue, Adhesive –
Beige Mottled
NAD N/A
See Lab
Report
Basement, Near
Outside Window
732-GSM-01
Grey Sink
Mastic
NAD N/A
See Lab
Report
732-GSM-02
Grey Sink
Mastic
NAD N/A
See Lab
Report
Room 1224, Breakroom
732-GSM-03
Grey Sink
Mastic
NAD N/A
See Lab
Report
732-PI1-01
Pipe Insulation
– Paper
Wrapped with
Fiberglass
NAD N/A
See Lab
Report Room 1229
732-PI1-02
Pipe Insulation
– Paper
Wrapped with
Fiberglass
NAD N/A
See Lab
Report Room 1229
732-PI1-03
Pipe Insulation
– Paper
Wrapped with
Fiberglass
NAD N/A
See Lab
Report Corridor 1211 12
732-PI1-04
Pipe Insulation
– Paper
Wrapped with
Fiberglass
NAD N/A
See Lab
Report Corridor 1211
732-PI1-05
Pipe Insulation
– Paper
Wrapped with
Fiberglass
NAD N/A
See Lab
Corridor 1248
NAD – No Asbestos Detected; N/A – Not Applicable
Representative Photographs of Suspect Asbestos Containing
Materials
1. Blue Carpet Adhesive (HM #1)
2. Blue Covebase and Associated Adhesive (HM #2)
3. Beige Covebase and Associated Adhesive (HM #3)
4. Ceramic Tile (HM #4)
5. Ceiling Tile – 2’ X 2’ Smooth White (HM #5)
6. Ceiling Tile – 2’ X 2’ White with Small Fissures, Gouges and Pinholes (HM #6)
7. Duct Mastic on Foil Duct - White (HM #7)
8. Drywall and Joint Compound (HM #8)
9. Exterior Wall BATT Insulation (HM #9)
10. 12” X 12” Floor Tile and Associated Mastic, Glue, Adhesive – Beige Mottled (HM #10)
11. Grey Sink Mastic (HM #11)
12. Pipe Insulation – Paper Wrapped with Fiberglass (HM #12)
APPENDIX B
Paint Chip Sample Summary Table Followed by Laboratory Data and Representative Photographs of Paint Chip Samples
Collection
Date
Sample
Number
Description Location Analytical
Method
Percent Lead by Weight
(wt%)
03/02/2016 732-PC-01
Beige Paint on
Metal Door
Basement, Room
102, Janitor’s
Closet
AAS BRL
03/02/2016 732-PC-02
Beige Paint on
Metal Door
Frame
Basement, Room
102, Janitor’s
Closet
AAS BRL
03/02/2016 732-PC-03
Beige Paint on
Metal Structural
Column
Basement, Near
Bar Area
AAS BRL
03/02/2016 732-PC-04
Beige Paint on
Metal Structural
Column
1st Floor, Room
1238, Janitor’s
Closet
AAS 0.111
03/02/2016 732-PC-05
Beige Paint on
CMU Block
Wall
1st Floor, Room
1238, Janitor’s
Closet
AAS BRL
BRL: Not Detected at the Reporting Limit
1. Beige Paint on Metal Door, Basement, Room 102, Janitor’s Closet (Sample # 732-PC-01)
2. Beige Paint on Metal Door Frame, Basement, Room 102, Janitor’s Closet (Sample # 732-PC-
02)
3. Beige Paint on Metal Structural Column, Basement, Near Bar Area (Sample # 732-PC-03)
4. Beige Paint on Metal Structural Column, 1st Floor, Room 1238, Janitor’s Closet (Sample #
732-PC-04)
5. Beige Paint on CMU Block Wall, 1st Floor, Room 1238, Janitor’s Closet (Sample # 732-PC-
05)