Attachment_3_-_Pricing_Schedule.xls

XLS spreadsheet 34 KB Posted

Attached to
DFAC Boiler Replace Federal contract opportunity
Solicitation number
FA5575-18-Q-0002
Issued by
Department of the Air Force United States Air Forces in Europe - Air Forces Africa

About this file

Attachment 3 - Pricing Schedule

View the file

Other files for this federal contract opportunity

Other files attached to DFAC Boiler Replace, newest first.
File Type Posted
Questions_and_Answers_-_18-Q-0002_-__DFAC_Boiler_Replace.pdf PDF
FA5575-18-Q-0002_-__DFAC_Boiler_Replace_-_RFQ.pdf PDF
Attachment_1_-_PWS_18116_Replace_DFAC_Boilers.pdf PDF
Attachment_2_-_ROT_18116_Sustituir_DFAC_Calderas.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contractor

Attachment 3 - Pricing Schedule
CONTRACTOR:ADDRESS:
CONTRACT FOR (Work to be performed):PROPOSED TOTAL CONTRACT PRICE
RPL BOILERS AT DFAC0.00 €
PERIOD OF PERFORMANCE:WORK ORDER NUMBER:WORK LOCATION:
QUOTE EXPIRATION:18116MORON AIR BASE, SPAIN
UNITMATERIAL COSTLABOR COSTSOTHER
LINITEMOFDIRECTLINE
NO.MEAS.QUANTI.UNITTOTALMH/MDAV.RATTOTALCOSTSTOTAL
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
1Removal existing Boilers
Ls
2Removal existing Water Softener
Ls
3Boiler OMNIVAP 2.00, Pressure body, Thermal Isolation
and cleaning handtoolsEa
4Electric Panelboard 3x208x60 Hz
Ea
5CE Labeled according Air Force Instruction 32-1068
Ls
6Globe Valves PN16/40 ARI (Water/Steam/Aeration/Draining)
Ls
7Automatic Bottom Mud Blowdown (Safety Integrity Level: Sil 3) GESTRA MPA
Ls
8Check Valves RK 86 DN-32 GESTRA
Ls
9Safety level & Control Level System SIL 3
Ls
10Pressure Gauges Manifold including: Manometer, pressure transmitter, safety PS, operating PS, needle valve
Ls
11Pump 3x208V 60Hz, on boiler frame including accessories: transducers, valves and manometers
Ls
12Automatic Bottom Salt Blowdown PN40 DN20 (Safety Integrity Level: Sil 3) GESTRA
Ls
13Sampling Cooler Gestra PK-40 NS
Ls
14Burner TK7/150 60 Hz Modulated by Tekener. Fuel consumption 150 Kg/h
Ls
15Water Softener Twin Version, 2 resine bottles 125 liters each, plus 250 liters of cationic resin
Ea
16Water Softener Twin Version, 2 resine bottles 125 liters each, plus 250 liters of cationic resin & electronic devices
Ea
17Start up
OCA Revision type CEa
18Documents, as-builts and miscellaneous
Ls
TOTAL
DATE:FIRM NAME:DUNS:
TITLE:BY:
NOTE: The individual signing must be a signatory official for this Entity; signature constitutes agreement to all terms/conditions contained within this solicitation. Please provide quotes in Euros.

&L&"Times New Roman,Regular"AF Form 3052 (Computer Generated)&C&"Times New Roman,Bold"FOR OFFICIAL USE ONLY&R&"Times New Roman,Regular"Page &P of &N