CLIN_Structure.xlsx

XLSX spreadsheet 16 KB Posted

Attached to
Tension Fabric Structures for Vehicle Storage Federal contract opportunity
Solicitation number
FA5240-16-Q-M003
Issued by
Department of the Air Force Pacific Air Forces

About this file

CLIN Structure

View the file

Other files for this federal contract opportunity

Other files attached to Tension Fabric Structures for Vehicle Storage, newest first.
File Type Posted
Questions_and_Answers_Amendment_01.pdf PDF
wind_rose.pptx PPTX presentation
Attachment_1.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

CLIN STRUCTURE (Attachment 1)
ItemDescription or MaterialQuantityUnitEstimated PriceExtended Price
0001FABRIC STRUCTURE - 100' wide X 100' long X 33' center height X 13' side wall1ea0
ADDITIONAL DESCRIPTION:
A. 22 OZ Cover, Translucent white, flame retardant PVC laminated fabrick. Fabric meets state of California fire marshall and NFPA 701. Frame members: Heavy wall galvanized tubular steel truss design Trusses built on 10' centers.
B. Continuous base beam system allows the shelter to be erected on a dirt, gravel, asphault or concrete foundation.
C. Anchors provided for a concreete, asphault or dirt foundation.
D. Fabric ends at the base beam level. A skirt further seals the base at the ground level.
E. All weld joints coated with 97% zinc "cold Gal" for corrosion protection.
F. Connections via a plate to plate junction with A-325 bolts.
0002End panels - two access end panels with 2 each 20' wide X 18' tall roll up fabric doors per end. Doors raise and lower via a manually operated winch. Doors operate within a track assembly. Also includes 2 aluminum entry personnel doors.2ea0
0003Light Kit - Consists of 15ea - 400W metal halide Hi-Bay lights. System is a reloc system. Also includes all wiring, hangars, 100A breaker box, junctions, etc.1ea0
0004FABRIC STRUCTURE - 118' wide X 160' long X 37' center height X 14' side wall1ea0
ADDITIONAL DESCRIPTION:
A. 22 OZ Cover, Translucent white, flame retardant PVC laminated fabrick. Fabric meets state of California fire marshall and NFPA 701. Frame members: Heavy wall galvanized tubular steel truss design Trusses built on 10' centers.
B. Continuous base beam system allows the shelter to be erected on a dirt, gravel, asphault or concrete foundation.
C. Anchors provided for a concreete, asphault or dirt foundation.
D. Fabric ends at the base beam level. A skirt further seals the base at the ground level.
E. All weld joints coated with 97% zinc "cold Gal" for corrosion protection.
F. Connections via a plate to plate junction with A-325 bolts.
0005End panels - two access end panels with 2 each 20' wide X 18' tall roll up fabric doors per end. Doors raise and lower via a manually operated winch. Doors operate within a track assembly. Also includes 2 aluminum entry personnel doors.2ea0
0006Light Kit - Consists of 24ea - 400W metal halide Hi-Bay lights. System is a reloc system. Also includes all wiring, hangars, 100A breaker box, junctions, etc.1ea0
0007FABRIC STRUCTURE - 68' wide X 170' long X 28' center height X 12' side wall1ea0
ADDITIONAL DESCRIPTION:
A. 22 OZ Cover, Translucent white, flame retardant PVC laminated fabrick. Fabric meets state of California fire marshall and NFPA 701. Frame members: Heavy wall galvanized tubular steel truss design Trusses built on 10' centers.
B. Continuous base beam system allows the shelter to be erected on a dirt, gravel, asphault or concrete foundation.
C. Anchors provided for a concreete, asphault or dirt foundation.
D. Fabric ends at the base beam level. A skirt further seals the base at the ground level.
E. All weld joints coated with 97% zinc "cold Gal" for corrosion protection.
F. Connections via a plate to plate junction with A-325 bolts.
0008End panels - two access end panels with 2 each 20' wide X 18' tall roll up fabric doors per end. Doors raise and lower via a manually operated winch. Doors operate within a track assembly. Also includes 2 aluminum entry personnel doors.2ea0
0009Light Kit - Consists of 16ea - 400W metal halide Hi-Bay lights. System is a reloc system. Also includes all wiring, hangars, 100A breaker box, junctions, etc.1ea0
0010Shipping Costs to Consolidation Point (Tracy Depot in California)1ea0
TOTAL0
***The end panel fabric doors for each shelter need to be 20' wide by 18' tall and the personnel entry doors need to be standard 3' by 7' door with key lock door handle (prefer Kwikset or Schlage type key).

Sheet2

Sheet3

File details come from the government source that posted it. Updated .