TO_00-25-252J.pdf
PDF 79 KB Posted
- Attached to
- Digital Radiographic Imaging System Federal contract opportunity
- Solicitation number
- FA5209-16-T-0145
About this file
Technical Order 00-25-252J
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| MXMFN_PWS_CR_System.docx | DOCX document | |
| FA520916T0145_DRIS.pdf | ||
| FA520916T0145_PWS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
w
Table3A. CR Systems Qualified forWelder Certification
CR System Component Component Information CR System
CR Scanner (Reader) manufacturer GE GE Carestream/Kodak Durr VMI model number CRx Tower
CR25NDTor
CR35NDT
CR Flex HPX-1 HD-CR35 5100MS equipment settings gain 150 PMT gain = 40 PMT gain = 600 PMT gain = 4.5 laser power laser power = HIGH laser power = 4 laser power =14 other
(specify) speed = 50 Beam Deflect Spd
= 2000 other
(specify) sampling resolution 50 micron 50 micron 25 micron 16 micron 30 micron maximum pixel value 65504 65504 4096 65535 65500
Imaging Plates (IP) manufacturer/type GE IPU or
Carestream XL
Blue
GEIPU Carestream XL Blue Carestream XL
Blue
Carestream XL Blue
Processing Cassette (if applicable) manufacturer GE n/a n/a n/a n/a type hard n/a n/a n/a n/a model very high resolution n/a n/a n/a n/a
Viewing Monitor display size (inches, diagonal)
21 21 21 15 21 resolution (megapixels, MP)
3 3 3 or 5 5 3
NOTE
CR systems shall pass USAF CR Process Controlsfor crack detection systems per TO 33B-1-2WP 106 01 with two exceptions:
1) Spatialresolution shall be 8 Ip/mm in bothorientations (TO 33B-1-2 WP 106 01 para 4.6) when viewed at 2Xabsolute magnification
2) Table 3B shall be used in lieuof TO 33B-1-2 WP 106 01 Table 4. "Technique and PV Range for EPS Test" o o
ISJ
OI
w n n
TO 00-25-252J
Table 3B. Technique and PV Range for TO 33B-I-2 EPS Test (welder certification systems)
CR scanner IP kV mA
Time (sec)
Allowable Pixel Value Range
Min Max
GE CR Tower GElPUor
Carestream XL Blue 70 5 180 12000 62000
GE CR Flex GEIPU 75 5 180 10000 62000
Carestream HPX-l Carestream XL Blue 70 5 180 2500 3900
Durr HD CR-35 Carestream XL Blue 75 5 180 10000 62000
VMI5100MS Carestream XL Blue 65 5 180 13000 62000
29. WP 005 04, Page 12,Table 4 ofthe basic manual has been amended to read as follows:
Table 4. Recommended Inspection Setting
MATERIAL MATERIAL
THICKNESS
KV MA TIME IQI FILM
Steel Tube 1.070.050" thick tube 120 4 4m, 14 sec
FE.25 5x7 M-8Pb
Stainless Steel
Tube
1.070.050" thick tube 120 4 4m, 14 sec
SS.25 5x7M-8Pb
Inconel Tube 1.070.050" thick tube 130 4 4m, 14 sec
IN .25 5x7 M-8Pb
Aluminum
Tube
1.070.050" thick tube 50 4 4m, 14 sec
AL.25 5 x 7 M-8
Magnesium Tube
1.070.050" thick tube 40 4 5m, 38 sec
MG.25 5 x 7 M-8
Titanium Tube 1.070.050" thick tube 90 4 4m, 14 sec
TI.25 5 x 7 M-8
Cobalt Tube 1.070.050" thick tube 140 4 8m, 27 sec
IN .25 5x7M-8Pb
Steel Sheet 0.250" thick sheet 150 4 12m, 39 sec
FE.43 5x7 M-8Pb
Steel Sheet 0.032" thick sheet 120 4 2m, 5 sec
FE.25 5 x 7 M Pb
Steel Sheet 0.125" thick sheet 120 4 5 min FE.25 5 x 7 M Pb
Stainless Steel
Sheet
0.020" thick sheet 120 4 lm,27 sec
SS.25 5 x 7 M Pb
File details come from the government source that posted it. Updated .