Attachment_2_DRAWING_SET.pdf

PDF 1 MB Posted

Attached to
Hangar 3 Earthquake Repair Federal contract opportunity
Solicitation number
FA5000-19-Q-A064
Issued by
Department of the Air Force Pacific Air Forces

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Hangar 3 Earthquake Repair, newest first.
File Type Posted
Solicitation_Amendment_FA500019QA0640002_SF_30.pdf PDF
Solicitation_Amendment_-_FA500019QA0640002.pdf PDF
7_Drawings.pdf PDF
6_SOW_and_Specifications.pdf PDF
Solicitation_Amendment_FA500019QA0640001_SF_30.pdf PDF
Solicitation_Amendment_-_FA500019QA0640001.pdf PDF
Solicitation_-_FA500019QA064.pdf PDF
Attachment_3_AF_66.xls XLS spreadsheet
Attachment_1_SOW_and_Specifications.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

JOINT BASE ELMENDORF-RICHARDSON

SCHEDULE OF DRAWINGS

SHEET REFERENCE NUMBER SHEET TITLE

G-001

LOCATION PLAN AND SCHEDULE OF DRAWINGS

E-100

FIRST FLOOR NORTH SOUTH WING ELECTRICAL LIGHTING PLAN

E-101

SECOND FLOOR NORTH SOUTH WING ELECTRICAL LIGHTING PLAN

673RD CIVIL ENGINEER SQUADRON

PROJECT LOCATION

MAP KEY

LOCATION DESCRIPTION

RICHARDSON VISITORS GATE

ELMENDORF VISITORS GATE

8517 20TH STREET: SECURITY FORCES

730 QUARTERMASTER ROAD: 673D CES CONTRACT MANAGEMENT

10480 SIJAN AVENUE: CONTRACTING

KEY PLAN

(SEE KEY PLAN)

PROJECT NOTES:

1.

A B C D E F G H

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

SYMBOL DATE DESCRIPTION

REVISIONS

F I L E

N

O

JOINT BASE ELMENDORF-RICHARDSON, AK

DESIGNED BY:

DRAWN BY:

CHECKED BY:

PROJ. ENG.

DESIGN

DESIGNER LOGOS

AF CONTRACT NUMBER:

FACILITY:

DATE APPR

DATE:

DATE:

DATE:

DATE:

I

AIR FORCE

HANGAR 3 REPAIR CEILING

10571 HANGAR 3

LOCATION PLAN AND SCHEDULE OF DRAWINGS

NONE

FXSB19

FXSB19G001.dwg

G001

PROJECT

LOCATION

B

M

S

A B C D E F G H

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

SYMBOL DATE DESCRIPTION

REVISIONS

F I L

E

N

O

JOINT BASE ELMENDORF-RICHARDSON, AK

DESIGNED BY:

DRAWN BY:

CHECKED BY:

PROJ. ENG.

DESIGN

DESIGNER LOGOS

AF CONTRACT NUMBER:

FACILITY:

DATE APPR

DATE:

DATE:

DATE:

DATE:

I

AIR FORCE

HANGAR 3 REPAIR CEILING

10571 HANGAR 3

1ST FLR NORTH SOUTH WING ELEC LIGHTING PLAN

1/8"=1'-0"

FXSB19-

FXSB19E100.dwg

E100

0 2' 4' 8' 16'1'

SCALE: 1/8" = 1'-0"

24'

NORTH WING FIRST FLOOR

0 2' 4' 8' 16'1'

SCALE: 1/8" = 1'-0"

24'

SOUTH WING FIRST FLOOR

PLAN NORTH

LEGEND:

R

M

B

S

HANGING BLUE STROBE, RE-ATTACH FIXTURE

2' x 4' RECESSED FIXTURE

RECESSED CAN

HANGING MOTION SENSOR, RE-ATTACH

HANGING SMOKE DETECTOR, RE-ATTACH

RE-LAMP AND

RE-BALLAST 3-LAMP T8

HANGING MOTION SENSOR,

RE-ATTACH SENSOR

2' x 2' RECESSED FIXTURE

RE-LAMP AND

RE-BALLAST 3-LAMP T8

105B105A

MENS WOMENS

104104104103

102B

102A

SNACK BAR

KITCHEN

111110

112A 113 114A 115 115B

MENS

116B

116A

HANGING SMOKE DETECTOR

RE-ATTACH

HANGING BLUE STROBE,

RE-ATTACH, TYPICAL

R R R R

H

H

H

H

A B C D E F G H

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

SYMBOL DATE DESCRIPTION

REVISIONS

F I L E

N

O

JOINT BASE ELMENDORF-RICHARDSON, AK

DESIGNED BY:

DRAWN BY:

CHECKED BY:

PROJ. ENG.

DESIGN

DESIGNER LOGOS

AF CONTRACT NUMBER:

FACILITY:

DATE APPR

DATE:

DATE:

DATE:

DATE:

I

AIR FORCE

HANGAR 3 REPAIR CEILING

10571 HANGAR 3

SECOND FLOOR ELECTRICAL LIGHTING PLAN

1/8"=1'-0"

FXSB19

FXSB19E102.dwg

E101

0 2' 4' 8' 16'1'

SCALE: 1/8" = 1'-0"

24'

NORTH WING SECOND FLOOR

0 2' 4' 8' 16'1'

SCALE: 1/8" = 1'-0"

24'

SOUTH WING SECOND FLOOR

PLAN NORTH

LEGEND:

R

B

HANGING BLUE STOBE, RE-ATTACH FIXTURE

2' x 4' RECESSED FIXTURE

RECESSED CAN

1' x 4' SURFACE FIXTURE

HANGING HEAT DETECTOR, RE-ATTACH

EXIT SIGN LIGHT

H

RE-INSTALL AND SECURE

2' X 4' LAY-IN

RE-ATTACH

LOOSE

HEAT

DETECTOR

REPLACE EXIST EXIST SIGN WITH NEW

LED DUAL FACE GREEN LETTER AND SELF

TESTING BATTERY BACKUP

2' x 2' RECESSED FIXTURE

REPLACE EXIST EXIST SIGN WITH NEW LED DUAL FACE

GREEN LETTER AND SELF TESTING BATTERY BACKUP

REPLACE4-EACH EXISTING 6" RECESSED CAN 4PIN CFL FIXTURE WITH NEW

13W LED RECESSED CAN FIXTURE PROVIDE NEW GRID TILES AS REQUIRED.

RE-LAMP AND

RE-BALLAST

2-LAMP T8

RE-LAMP AND

RE-BALLAST

2-LAMP T8

RE-LAMP AND

RE-BALLAST

2-LAMP T8

RE-LAMP AND

RE-BALLAST

2-LAMP T8

RE-ATTACH LOOSE

HEAT DETECTOR

RE-ATTACH

LOOSE

HEAT

DETECTOR

RE-LAMP AND

RE-BALLAST 3-LAMP T8

RE-LAMP AND

RE-BALLAST

3-LAMP T8

RE-LAMP AND

RE-BALLAST

3-LAMP T8

201B

200B

202B

AUDITORIUM

213B

213A

MENS

218B

218A

224A

224B

MENS

WOMEN

231A

RE-ATTACH

LOOSE

HEAT

DETECTOR

RE-ATTACH

RE-ATTACH

PROVIDE NEW FIXTURE

3 LAMP T8

G001-Layout1
Sheets and Views
Layout1
E100-Layout1
Sheets and Views
Layout1
E101-Layout1
Sheets and Views
Layout1

File details come from the government source that posted it.