7_Drawings.pdf
PDF 1 MB Posted
- Attached to
- Hangar 3 Earthquake Repair Federal contract opportunity
- Solicitation number
- FA5000-19-Q-A064
About this file
Updated Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation_Amendment_FA500019QA0640002_SF_30.pdf | ||
| Solicitation_Amendment_-_FA500019QA0640002.pdf | ||
| 6_SOW_and_Specifications.pdf | ||
| Solicitation_Amendment_FA500019QA0640001_SF_30.pdf | ||
| Solicitation_Amendment_-_FA500019QA0640001.pdf | ||
| Solicitation_-_FA500019QA064.pdf | ||
| Attachment_3_AF_66.xls | XLS spreadsheet | |
| Attachment_2_DRAWING_SET.pdf | ||
| Attachment_1_SOW_and_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOINT BASE ELMENDORF-RICHARDSON
SCHEDULE OF DRAWINGS
SHEET REFERENCE NUMBER SHEET TITLE
G-001
LOCATION PLAN AND SCHEDULE OF DRAWINGS
E-100
FIRST FLOOR NORTH SOUTH WING ELECTRICAL LIGHTING PLAN
E-101
FIRST FLOOR WEST WING ELECTRICAL LIGHTING PLAN
E-102
SECOND FLOOR NORTH SOUTH WING ELECTRICAL LIGHTING PLAN
673RD CIVIL ENGINEER SQUADRON
PROJECT LOCATION
MAP KEY
LOCATION DESCRIPTION
RICHARDSON VISITORS GATE
ELMENDORF VISITORS GATE
8517 20TH STREET: SECURITY FORCES
730 QUARTERMASTER ROAD: 673D CES CONTRACT MANAGEMENT
10480 SIJAN AVENUE: CONTRACTING
KEY PLAN
(SEE KEY PLAN)
PROJECT NOTES:
1.
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
F I L E
N
O
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
DESIGNER LOGOS
AF CONTRACT NUMBER:
FACILITY:
DATE APPR
DATE:
DATE:
DATE:
DATE:
I
AIR FORCE
HANGAR 3 REPAIR CEILING
10571 HANGAR 3
LOCATION PLAN AND SCHEDULE OF DRAWINGS
NONE
FXSB19
FXSB19G001.dwg
G001
PROJECT
LOCATION
B
M
S
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
F I
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
DESIGNER LOGOS
AF CONTRACT NUMBER:
FACILITY:
DATE APPR
DATE:
DATE:
DATE:
DATE:
I
AIR FORCE
HANGAR 3 REPAIR CEILING
10571 HANGAR 3
1ST FLR NORTH SOUTH WING ELEC LIGHTING PLAN
1/8"=1'-0"
FXSB19-
FXSB19E100.dwg
E100
0 2' 4' 8' 16'1'
SCALE: 1/8" = 1'-0"
24'
NORTH WING FIRST FLOOR
0 2' 4' 8' 16'1'
SCALE: 1/8" = 1'-0"
24'
SOUTH WING FIRST FLOOR
PLAN NORTH
LEGEND:
R
M
B
S
HANGING BLUE STROBE, RE-ATTACH FIXTURE
2' x 4' RECESSED FIXTURE
RECESSED CAN
HANGING MOTION SENSOR, RE-ATTACH
HANGING SMOKE DETECTOR, RE-ATTACH
RE-LAMP AND
RE-BALLAST 3-LAMP T8
HANGING MOTION SENSOR,
RE-ATTACH SENSOR
2' x 2' RECESSED FIXTURE
RE-LAMP AND
RE-BALLAST 3-LAMP T8
105B105A
MENS WOMENS
104104104103
102B
102A
SNACK BAR
KITCHEN
111110
112A 113 114A 115 115B
MENS
116B
116A
HANGING SMOKE DETECTOR
RE-ATTACH
HANGING BLUE STROBE,
RE-ATTACH, TYPICAL
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
F I
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
DESIGNER LOGOS
AF CONTRACT NUMBER:
FACILITY:
DATE APPR
DATE:
DATE:
DATE:
DATE:
I
AIR FORCE
HANGAR 3 REPAIR CEILING
10571 HANGAR 3
1ST FLR WEST WING ELEC LIGHTING PLAN
1/8"=1'-0"
FXSB19-
FXSB19E101.dwg
E101
0 2' 4' 8' 16'1'
SCALE: 1/8" = 1'-0"
24'
WEST WING FIRST FLOOR
PLAN NORTH
LEGEND:
2' x 4' RECESSED FIXTURE
RE-BALLAST AND
RE-LAMP FIXTURE
3-TUBE T8
R R R R
H
H
H
H
A B C D E F G H
SHEET
REFERENCE
NUMBER
ANSI
D
AF PROJECT NUMBER:
AEC FILE NAME:
DRAWING SCALE:
SYMBOL DATE DESCRIPTION
REVISIONS
F I
JOINT BASE ELMENDORF-RICHARDSON, AK
DESIGNED BY:
DRAWN BY:
CHECKED BY:
PROJ. ENG.
DESIGN
DESIGNER LOGOS
AF CONTRACT NUMBER:
FACILITY:
DATE APPR
DATE:
DATE:
DATE:
DATE:
I
AIR FORCE
HANGAR 3 REPAIR CEILING
10571 HANGAR 3
SECOND FLOOR ELECTRICAL LIGHTING PLAN
1/8"=1'-0"
FXSB19
FXSB19E102.dwg
E102
0 2' 4' 8' 16'1'
SCALE: 1/8" = 1'-0"
24'
NORTH WING SECOND FLOOR
0 2' 4' 8' 16'1'
SCALE: 1/8" = 1'-0"
24'
SOUTH WING SECOND FLOOR
PLAN NORTH
LEGEND:
R
B
HANGING BLUE STOBE, RE-ATTACH FIXTURE
2' x 4' RECESSED FIXTURE
RECESSED CAN
1' x 4' SURFACE FIXTURE
HANGING HEAT DETECTOR, RE-ATTACH
EXIT SIGN LIGHT
H
RE-INSTALL AND SECURE
2' X 4' LAY-IN
RE-ATTACH
LOOSE
HEAT
DETECTOR
REPLACE EXIST EXIST SIGN WITH NEW
LED DUAL FACE GREEN LETTER AND SELF
TESTING BATTERY BACKUP
2' x 2' RECESSED FIXTURE
REPLACE EXIST EXIST SIGN WITH NEW LED DUAL FACE
GREEN LETTER AND SELF TESTING BATTERY BACKUP
REPLACE4-EACH EXISTING 6" RECESSED CAN 4PIN CFL FIXTURE WITH NEW
13W LED RECESSED CAN FIXTURE PROVIDE NEW GRID TILES AS REQUIRED.
RE-LAMP AND
RE-BALLAST
2-LAMP T8
RE-LAMP AND
RE-BALLAST
2-LAMP T8
RE-LAMP AND
RE-BALLAST
2-LAMP T8
RE-LAMP AND
RE-BALLAST
2-LAMP T8
RE-ATTACH LOOSE
HEAT DETECTOR
RE-ATTACH
LOOSE
HEAT
DETECTOR
RE-LAMP AND
RE-BALLAST 3-LAMP T8
RE-LAMP AND
RE-BALLAST
3-LAMP T8
RE-LAMP AND
RE-BALLAST
3-LAMP T8
201B
200B
202B
AUDITORIUM
213B
213A
MENS
218B
218A
224A
224B
MENS
WOMEN
231A
RE-ATTACH
LOOSE
HEAT
DETECTOR
RE-ATTACH
RE-ATTACH
PROVIDE NEW FIXTURE
3 LAMP T8
| G001-Layout1 |
| Sheets and Views |
| Layout1 |
| E100-Layout1 |
| Sheets and Views |
| Layout1 |
| E101-Layout1 |
| Sheets and Views |
| Layout1 |
| E102-Layout1 |
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it.