Statement_of_Work_25_Jan_16.pdf

PDF 472 KB Posted

Attached to
Install Closed Cell Spray Foam Insulation Federal contract opportunity
Solicitation number
FA5000-16-R-0021
Issued by
Department of the Air Force Pacific Air Forces

About this file

FA5000-16-R-0021 Statement of Work

View the file

Other files for this federal contract opportunity

Other files attached to Install Closed Cell Spray Foam Insulation, newest first.
File Type Posted
Revised_Statement_of_Work_20_May_16.pdf PDF
FA5000-R-0021-0001.doc DOC document
FA5000-16-R-0021_Q A.docx DOCX document
16-R-0021_Solicitation_(Add_Site_Visit).doc DOC document
Copy_of_Gate_Pass_Request.xlsx XLSX spreadsheet
16-R-0021 _Spray_Foam_Insulation_Solicitation.doc DOC document
Drawings_530__3MAR16.pdf PDF
Wage_Determination.pdf PDF
16-R-0021 _Spray_Foam_Insulation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

773d Civil Engineer Squadron

Joint Base Elmendorf-Richardson, AK

25 January 2016

STATEMENT OF WORK

Install Spray-Foam Insulation at CBRN Training Facility Building 5303

FXSB

SECTION 1: PROJECT INFORMATION

1.1 PROJECT LOCATION: This project shall be completed as a routine requirement at building 5303 on Joint Base Elmendorf-Richardson, AK. Project hours are standard work hours 0700-1600 not to include Federal holidays or weekends..

1.2 UNIQUE REQUIREMENT: None

1.3 PROJECT DESCRIPTION: Install new spray foam insulation onto the interior of the outer walls and roof as necessary to satisfy requirements given in Section 3.

SECTION 2: GENERAL REQUIREMENTS

2.1 WORKMANSHIP: All work shall be accomplished in accordance with all applicable building and fire codes. Contractor shall field verify all measurements, quantities, or value stated by the Government.

2.2 WORKSITE: The contractor shall limit the work to the areas indicated by the government. The contractor shall make every effort not to disturb or obstruct portions of the facilities still occupied by the government. The contractor shall make efforts to minimize interference to Government operations. The contractor shall coordinate and schedule work with the Project Manager (773 CES/CEOER) prior the start of any operation. The contractor shall dispose of all construction debris off base at a disposal facility.

2.3 SITE SECURITY AND PROTECTION: The contractor shall make every effort to secure the work site, allowing only authorized personnel to enter the work site. The contractor shall protect the site from damage from weather, vandalism, and/or theft.

2.4 DAMAGE TO EXISTING SITE CONDITIONS: The contractor shall be responsible to repair any and all damage incurred to existing Real Property/Grounds due to poor workmanship at no cost to the government. Contractor shall not park or drive on sidewalk or grassy/snowy areas. Damage incurred shall be repaired at no cost to the government.

2.5 HEALTH/SAFETY: The contractor shall be responsible for compliance with OSHA and AFOSH standards. The contractor shall maintain a clean and debris free site at all times. The contractor shall keep driveways and entrances into and around the work site clear at all times.

FOR OFFICIAL USE ONLY

FA5000-16-R-0021, Attachment 1

The contractor shall not use driveways or entrances as employee parking or storage of materials unless otherwise stated. The contractor shall minimize storage of materials and equipment on site.

2.6 GREEN PROCURMENT: Contractor must incorporate “green procurement” principles into the design of their projects. Specifically, consult the EPA’s web site at www.epa.gov/cpg/products.htm for a listing of the products that have been mandated as green procurement requirements for purchases.

SECTION 3: DESCRIPTION OF WORK AND SPECIAL INSTRUCTIONS

3.1 General Requirements (Div 1)

3.1.1. Install a minimum of 5.5 inches of Closed-Cell Foam to reach a value of R-38 on the interior of the roof (appx. 6,000 SF).

3.1.2. Install a minimum of 3 inches of Closed-Cell Foam to reach a value of R-21 on the interior of the walls (appx. 8,000 SF).

3.2 Existing Conditions (Div 2)

3.2.1. Lumber wall framing will present along the outer walls during the insulation process. Contractor must work around existing conditions and meet required R-values.

3.3 Finishes (Div 9)

3.3.1. Any exposed insulation must be coated with an approved fire resistant coating.

3.5 Furnishings (Div 12)

3.5.1. Contractor shall provide all materials and tools to complete the work.

SECTION 4: SPECIAL PROVISIONS/NOTES/SPECIFICATIONS

4.1 All installation procedures shall follow the below specification:

4.1.1 Installation of spray-foam insulation and the application of fire resistant coating shall meet manufacturer’s conventional construction standards.

SECTION 5: PROJECT MANAGER