Text version

8312 W Northview St. #100, Boise, ID, 83704 • 208-323-8287 • www.industrialhygieneresources.com

Report of Asbestos and Lead Inspection MHAFB Gunfighters Club Mountain Home Air Force Base

Mountain Home, Idaho

Prepared for:

Meghann Donley, Project Manager HDR, Inc.

Prepared by:

Rebecca Ellis

AHERA Building Inspector Anthony Bongiovano

EPA Lead Inspector

Assessment Date:

June 28, 2018

Report Date:

July 9, 2018

Project Number:

F:\2018\IHR 2018\6019-HDR-MHAFB-Gun Fighter renovat-Asb & LBP\Narrative.docx

Executive Summary

Industrial Hygiene Resources (IHR: www.industrialhygieneresources.com) of Boise, Idaho was contracted by HDR, Inc. to conduct a hazardous materials inspection of the Gunfighters Club located on the Mountain Home Air Force Base in Mountain Home, Idaho. The inspection was focused on asbestos containing materials (ACM) and lead-based paints (LBP). This evaluation was the first action to support anticipated renovation of the structure.

Rebecca Ellis and Anthony Bongiovano, an EPA/State of IHR conducted the inspection on June 28, 2018. Rebecca is an accredited (AHERA)1 Asbestos Building Inspector and Anthony is an EPA Lead Based Paint Inspector. Matthew Call, CIH, CSP, Vice President of IHR reviewed and approved this survey report. Meghann Donley represented HDR, Inc. during this evaluation.

Conclusions

➢ Asbestos Containing Material (defined as containing greater than 1% asbestos) included:

transite paneling: ~450 ft2 of transite panels located on the exterior of the patio area.

➢ The brown painted metal posts located on the east contained lead.

➢ Any activities impacting the brown painted metal posts are subject to the OSHA Lead in Construction Standard.

Recommendations

✓ Any renovation of asbestos-containing materials must be performed in compliance with EPA and OSHA regulations. See specific recommendations at the end of this report.

✓ The OSHA Lead in Construction standard requires an exposure assessment for employees who disturb materials that contain lead. See specific recommendations at the end of this report.

1 AHERA: Asbestos Hazard Emergency Response Act - 1985 (“Asbestos in Schools”).

http://www.industrialhygieneresources.com/

Contents Executive Summary

Conclusions

Recommendations

Background

Objectives

Methods

Results and Discussion:

Conclusions

Recommendations

Lead-based paint on surface coatings:

Appendix A-Photolog

Appendix B- Laboratory Reports

Appendix C- Consultant’s Certifications

Limitations/Disclaimer

Background

The Gunfighters Club is located on the Mountain Home Air Force Base. The building was constructed in the 1960s and consisted of main floor, restrooms, dining halls, a kitchen, meeting room and a large ballroom. The building is single story with concrete with transite paneling.

The interior walls are drywall and brick, and the interior and exterior doors, door jambs, and wood base boards are either painted or covered with a clear finish. The ceilings are drywall or suspended ceiling tiles. The floor is constructed of wood and the ball room was covered with carpet.

The US Occupational Safety and Health Administration is charged with protecting the health of workers (OSHA: 34TUhttps://www.osha.gov/SLTC/asbestos/index.html U). OSHA considers building materials that contain any amount of asbestos to have the potential to cause excessive asbestos fiber exposures to employees (including contractors), and regulates operations and restoration work via its asbestos general industry and construction standards. The full standard applies when building materials contain greater than 1% asbestos (>1%).

Asbestos is also regulated by the US Environmental Protection Agency (EPA) via three regulations. All regulations apply when building materials contain greater than 1% asbestos (>1%):

1) National Emission Standards for Hazardous Air Pollutants (NESHAP-Asbestos)

2) Asbestos Hazard Emergency Response Act (AHERA-schools-1983). This Act provided officials in schools, K-12, with rules and guidance for the management of asbestos containing materials. The majority of asbestos related procedures and regulations are based on this act. EPA produced regulations (40CFR763) mandating eight topics, with the first one being inspections (as produced here in this report). This section also includes EPA Worker Protection Rule (subpart G of AHERA).

3) Asbestos School Hazard Abatement Reauthorization Act (ASHARA-1992). This regulation extended AHERA regulations to cover public and commercial buildings.

OSHA also regulates worker exposures to lead. OSHA considers any amount of lead in paint to have the potential to cause excessive lead exposures to workers (and to their children). Where lead is present in building materials, OSHA requires employers to perform exposure assessments that consider the type of work that may disturb the lead.

https://www.osha.gov/SLTC/asbestos/index.html

Table I. Potential hazards evaluated during this assessment, June 28, 2018.

Potential Hazard Source / Product Physical

State Defining

Threshold Source Limit Type

Asbestos Building Materials Solid >1.0 % Asbestos EPA Regulatory Lead-Based Paint Paint Solid Any amount OSHA Regulatory

Objectives

The purpose of this work was to identify Asbestos Containing Material (ACM) and Lead Based Paint (LBP) to support the planned renovation or demolition of this building. Ultimately, the purpose of this work was to protect building occupants and workers from asbestos and lead hazards.

Methods

Asbestos Inspection:

Rebecca Ellis, an accredited (AHERA)2 Asbestos Building Inspector, performed the survey work on June 28, 2018. Rebecca collected 30 bulk samples of building materials suspected of containing asbestos during the inspection. The asbestos sampling scheme was developed to comply with ASHARA and NESHAP requirements

Asbestos containing materials (ACM) are defined as materials with an asbestos content greater than 1% by volume (>1%). If a sample is found to have a trace of asbestos, but less than 10% by PLM, it should be assumed to be asbestos. In order for a material to not be considered ACM, the sample must be re-analyzed by the point-count method, and documented to be 1% or less (≤1%). No samples were point counted for this inspection.

Asbestos bulk samples were analyzed by DCM Science Lab, Inc. (www.dcmsciencelab.com) located at 12421 West 49th Ave, #6, Wheat Ridge, Colorado. DCM is accredited by the NVLAP/NIST3 program for asbestos in bulk materials. DCM Science Laboratory is also accredited by the AIHA4 for the analysis of asbestos air samples (www.aihaaccreditedlabs.org).

The laboratory results are presented in the Appendix.

2 AHERA: Asbestos Hazard Emergency Response Act - 1985 (“Asbestos in Schools”).

3 NVLAP/NIST: National Voluntary Laboratory Accreditation Program/National Institute of Standards and Technology (asbestos in bulk materials).

4 AIHA: American Industrial Hygiene Association.

http://www.dcmsciencelab.com/certQual.htm http://www.aihaaccreditedlabs.org/AccredPrograms/IHLAP/Pages/default.aspx

Lead-Based Paint:

Anthony Bongiovano, an accredited EPA Certified Lead Paint Inspector, performed the survey work on the same day June, 2018. Anthony used a direct reading, Thermo-Scientific, Niton®, XLp 300 Lead Paint Analyzer (Serial Number 23516) to quantify concentrations of lead in paint on surfaces. These included interior walls, doors, and door jambs. Anthony sampled 27 locations for lead and included periodic calibration checks for accuracy verification.

Table III. Sampling and Analytical Methods for Bulk Asbestos and Direct Reading XRF Samples

Air Contaminant Sample Type Analytical Method Detection limit

Asbestos Bulk Material PLM Method 600 0.25%

Lead Direct reading XRF 0.01 mg/cm2

Results and Discussion:

EPA-regulated Asbestos Containing Materials (Figures 1 &2 and Table IV):

The Figures and Table IV document the presence and concentrations of asbestos found in building materials from this inspection. The building materials found to have regulated amounts of asbestos are as follows:

Thermal System Insulation:

➢ None.

Surfacing:

➢ None.

Miscellaneous:

➢ Transite paneling: ~450 ft2 of transite panels located on the exterior of the patio area.

Non-Regulated Materials (no regulated amounts of asbestos):

➢ The following building material samples scheduled to be impacted for renovation were found to have no regulated amounts of asbestos (<1% asbestos by volume). Any of these types of building materials generated from remodeling or demolition activities can be discarded as general construction debris at the local landfill.

✓ Drywall ceilings and walls

✓ Ceiling tiles

✓ Brick mortar

✓ Textured drywall

Table IV: Asbestos Content in Building Materials: Gunfighters Club-MHAFB

Sample Number Description/Location Results %

Asbestos* Material Condition**

GFC-CT-1A Ceiling tile 2x4 light fissures/S side of ballroom N/A A. White paint ND B. Tan perlitic ceiling tile ND

GFC-CT-1B Ceiling tile 2x4 light fissures/ SE side of ballroom N/A

GFC-CT-1C Ceiling tile 2x4 light fissures/NE side of ballroom N/A

GFC-DW-1A Drywall/NE side of ballroom N/A

B. Tan fibrous ND C. White drywall ND

GFC-DW-1B Drywall/NW side of ballroom N/A

GFC-DW-1C Drywall/SW side of ballroom N/A

*Asbestos containing materials (ACM), under current EPA regulation are defined as material with an asbestos content greater than 1% by volume. OSHA regulation defines ACM as material with any amounts of asbestos content, including trace amounts. Bolded numbers are above the regulatory threshold for regulated asbestos.

** Good condition: no visible damage or deterioration Fair condition: damaged Poor condition: significantly damaged † Sample was point counted

Table IV (continued): Asbestos Content in Building Materials: Gunfighters Club-MHAFB

Sample Number

Description/Location Results %

Asbestos* Material Condition**

GFC-CT-2A Ceiling tile 2x2/E side of ballroom N/A

GFC-CT-2B Ceiling tile 2x2/E side of ballroom N/A

GFC-CT-2C Ceiling tile 2x2/E side of ballroom N/A

GFC-BM-1A Brick mortar/NE corner of ballroom N/A

A. Tan concrete ND

GFC-BM-1B Brick mortar/NW corner of central dining N/A

GFC-BM-1C Brick mortar/NE corner of central dining N/A

GFC-CT-3A Ceiling tile 1x1 suspended/center of central dining N/A

B. Tan ceiling tile ND

GFC-CT-3B Ceiling tile 1x1 suspended/S side of central dining N/A

GFC-CT-3C Ceiling tile 1x1 suspended/S side of central dining N/A

*Asbestos containing materials (ACM), under current EPA regulation are defined as material with an asbestos content greater than 1% by volume. OSHA regulation defines ACM as material with any amounts of asbestos content, including trace amounts. Bolded numbers are above the regulatory threshold for regulated asbestos.

** Good condition: no visible damage or deterioration Fair condition: damaged

Table IV (continued): Asbestos Content in Building Materials: Gunfighters Club-MHAFB

Sample Number Description/Location Results %

Asbestos* Material Condition**

GFC-CT-4A Ceiling tile 2x2 deep texture/East dining N/A

B. White ceiling tile ND

GFC-CT-4B Ceiling tile 2x2 deep texture/East dining N/A

GFC-CT-4C Ceiling tile 2x2 deep texture/East dining N/A

GFC-S-1A Soffit/Exterior patio side Good

A. Tan resin ND B. Tan transite 5.0% Chrysotile

GFC-S-1B Soffit/Exterior patio side Good

GFC-S-1C Soffit/Exterior patio side Good

GFC-F-1A Fascia/Exterior patio side Good

A. Tan transite 5.0% Chrysotile

GFC-F-1B Fascia/Exterior patio side Good A. Tan resin

*Asbestos containing materials (ACM), under current EPA regulation are defined as material with an asbestos content greater than 1% by volume. OSHA regulation defines ACM as material with any amounts of asbestos content, including trace amounts. Bolded numbers are above the regulatory threshold for regulated asbestos.

** Good condition: no visible damage or deterioration Fair condition: damaged

Table IV (continued): Asbestos Content in Building Materials: Gunfighters Club-MHAFB

Sample Number Description/Location Results %

Asbestos* Material Condition**

GFC-F-1C Fascia/Exterior patio side Good A. Tan transite 5.0% Chrysotile

GFC-DW-1D Drywall/N side of central dining N/A A. White texture ND B. White fibrous/yellow mastic ND C. Multicolored paint ND D. Tan fibrous ND E. White drywall ND

GFC-DW-1E Drywall/N side of central dining N/A

B. Multicolored paint ND C. Tan fibrous ND D. White drywall ND

GFC-DW-1F Drywall/E side of central dining N/A

B. Multicolored paint ND C. Grey texture ND D. Tan fibrous ND E. White drywall ND

GFC-TW-1A Texture wall/E side of central dining N/A A. Tan paint ND B. Grey concrete plaster ND

GFC-TW-1B Texture wall/E side of central dining N/A A. Tan paint ND B. Grey concrete plaster ND

GFC-TW-1C Texture wall/E side of central dining N/A A. Blue foam ND B. Tan paint ND C. Grey concrete plaster ND

*Asbestos containing materials (ACM), under current EPA regulation are defined as material with an asbestos content greater than 1% by volume. OSHA regulation defines ACM as material with any amounts of asbestos content, including trace amounts. Bolded numbers are above the regulatory threshold for regulated asbestos.

** Good condition: no visible damage or deterioration Fair condition: damaged

Lead-Based Paint (Table V):

Table V documents the concentrations of lead-based paint on the painted surfaces. In Table V, the column labeled Total Pb (PbC) is the concentration of lead in the paint in milligrams of lead per square centimeter of surface area (mg/cm2). Painted surfaces containing lead are marked with bold print.

Materials regulated under the OSHA Lead in Construction Standard:

➢ Brown painted metal posts located on the east patio (6.0 mg/cm2)

Lead in Surface Coatings (Table V):

Table V documents the amount of lead present in paint on building surfaces from this inspection.

Table V. Concentrations of Lead in in Surface Materials: Gunfighters Club-MHAFB

Reading No.

Color Component Substrate Area Side Total

Pb (PbC)

1 Red Calibration 0.9

2 Tan Wood Door Ball rm S < LOD 3 Tan Wood Door Ball rm S < LOD 4 Tan Wood Door Ball rm W < LOD

5 Tan Wood Door Ball rm N < LOD 6 Tan Metal Door Central dining N < LOD 7 Tan Metal Door Central dining N < LOD

8 Tan Metal Door Central dining E < LOD 9 Tan Metal Door Central dining S < LOD

10 Blue Metal Door East dining W < LOD 11 White Drywall Wall Ball rm S < LOD 12 Pink Drywall Ceiling Ball rm S < LOD

13 White Drywall Wall Central dining N < LOD 14 Tan Drywall Wall art Central dining E < LOD

15 Tan Drywall Wall art East dining W < LOD 16 White Styrofoam Wall art East dining W < LOD 17 White Drywall Wall East dining N < LOD

18 White Drywall Pillar East dining N < LOD 19 Green Drywall Wall East dining W < LOD

20 White Metal Fire Extinguisher case Ball rm W < LOD 21 White Metal Fire Extinguisher case Ball rm W < LOD

22 White Drywall Ceiling Ball rm N < LOD 23 Red Tile Floor Ball rm N < LOD 24 Green PVC Riser Central dining E < LOD

25 White Vinyl Post Patio E < LOD 26 Brown Metal Post Patio E 6 27 Brown Metal Door Patio E < LOD 28 Brown Metal Railing Patio E < LOD

29 Red Calibration 0.9

Conclusions

➢ Asbestos Containing Material (defined as containing greater than 1% asbestos) included:

transite paneling: ~450 ft2 of transite panels located on the exterior of the patio area.

➢ The brown painted metal posts located on the east contained lead.

➢ Any activities impacting the brown painted metal posts are subject to the OSHA Lead in Construction Standard.

Recommendations

✓ Any renovation of asbestos-containing materials must be performed in compliance with EPA and OSHA regulations. See specific recommendations at the end of this report.

✓ The OSHA Lead in Construction standard requires an exposure assessment for employees who disturb materials that contain lead. See specific recommendations at the end of this report.

Lead-based paint on surface coatings:

➢ For any demolition work that disturbs painted surfaces that contain any amount of lead, an exposure assessment (for lead) should be performed by a CIH. The exposure assessment will consider the work activities and methods planned, as well as the total amount of paint to be disturbed to determine the need for controls, including hazard communication, safe work practices, PPE, and exposure monitoring.

Report by:

Occupational Safety and Health AHERA Building Inspector Certification #5892-11

Report by:

Anthony S Bongiovano Industrial Hygiene Technician EPA Lead Inspector Certificate: LBP-I-I176053-1

Reviewed By:

Matthew Call, MS, CIH, CSP Vice President Industrial Hygiene Resources (IHR)

Appendix A-Photolog

Photo 1: View of asbestos transite panels located on east patio.

Photo 2: View of lead containing painted metal posts.

Appendix B- Laboratory Reports

12421 W. 49TH AVENUE, UNIT #6

WHEAT RIDGE, CO 80033 (303) 463-8270

BULK ASBESTOS TEST REPORT

CLIENT: ANALYSIS DATE: 7-3-18

INDUSTRIAL HYGIENE RESOURCES REPORTING DATE: 7-5-18

8312 NORTHVIEW, SUITE #100 RECEIPT DATE: 6-29-18

BOISE, ID 83704 CLIENT JOB NO.: 6019

PROJECT TITLE: MHAFB - GUN FIGHTER CLUB - ASB/LEAD INSPECTION

DCMSL PROJECT: IHR5339

PERCENTAGE COMPOSITION BY VISUAL ESTIMATE

TOTAL

DCMSL CLIENT TOTAL PERCENTAGE

SAMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED NUMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS

-1 GFC-CT-1A 6-28-18 A. WHITE PAINT 4.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 96.0% ND ____________ 70.0 30.0 100.0

ND

-2 GFC-CT-1B 6-28-18 A. WHITE PAINT 4.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 96.0% ND ____________ 70.0 30.0 100.0

ND

-3 GFC-CT-1C 6-28-18 A. WHITE PAINT 2.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 98.0% ND ____________ 70.0 30.0 100.0

ND

-4 GFC-DW-1A 6-28-18 A. WHITE PAINT 3.0% ND 0.0 100.0 100.0

B. TAN FIBROUS 12.0% ND 100.0 0.0 100.0

C. WHITE DRYWALL 85.0% ND ____________ 1.0 99.0 100.0

ND

-5 GFC-DW-1B 6-28-18 A. WHITE PAINT 3.0% ND 0.0 100.0 100.0

B. TAN FIBROUS 25.0% ND 100.0 0.0 100.0

C. WHITE DRYWALL 72.0% ND ____________ 1.0 99.0 100.0

ND

-6 GFC-DW-1C 6-28-18 A. WHITE PAINT 2.0% ND 0.0 100.0 100.0

B. TAN FIBROUS 10.0% ND 100.0 0.0 100.0

C. WHITE DRYWALL 88.0% ND ____________ 1.0 99.0 100.0

ND

-7 GFC-CT-2A 6-28-18 A. WHITE PAINT 3.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 97.0% ND ____________ 72.0 28.0 100.0

ND

BULK ASBESTOS TEST REPORT

CLIENT: ANALYSIS DATE: 7-3-18

INDUSTRIAL HYGIENE RESOURCES REPORTING DATE: 7-5-18

8312 NORTHVIEW, SUITE #100 RECEIPT DATE: 6-29-18

BOISE, ID 83704 CLIENT JOB NO.: 6019

PROJECT TITLE: MHAFB - GUN FIGHTER CLUB - ASB/LEAD INSPECTION

DCMSL PROJECT: IHR5339

PERCENTAGE COMPOSITION BY VISUAL ESTIMATE

TOTAL

DCMSL CLIENT TOTAL PERCENTAGE

SAMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED NUMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS

-8 GFC-CT-2B 6-28-18 A. WHITE PAINT 4.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 96.0% ND ____________ 72.0 28.0 100.0

ND

-9 GFC-CT-2C 6-28-18 A. WHITE PAINT 3.0% ND 0.0 100.0 100.0

B. TAN PERLITIC CEILING TILE 97.0% ND ____________ 72.0 28.0 100.0

ND

-10 GFC-BM-1A 6-28-18 A. TAN CONCRETE 100.0% ND ____________ 0.0 100.0 100.0

ND

-11 GFC-BM-1B 6-28-18 A. TAN CONCRETE 100.0% ND ____________ 0.0 100.0 100.0

ND

-12 GFC-BM-1C 6-28-18 A. TAN CONCRETE 47.0% ND 0.0 100.0 100.0

B. RED BRICK 53.0% ND ____________ 0.0 100.0 100.0

ND

-13 GFC-CT-3A 6-28-18 A. WHITE PAINT 5.0% ND 0.0 100.0 100.0

B. TAN CEILING TILE 95.0% ND ____________ 85.0 15.0 100.0

ND

-14 GFC-CT-3B 6-28-18 A. WHITE PAINT 1.0% ND 0.0 100.0 100.0

B. TAN CEILING TILE 99.0% ND ____________ 85.0 15.0 100.0

ND

-15 GFC-CT-3C 6-28-18 A. WHITE PAINT 4.0% ND 0.0 100.0 100.0

B. TAN CEILING TILE 96.0% ND ____________ 85.0 15.0 100.0

BULK ASBESTOS TEST REPORT

CLIENT: ANALYSIS DATE: 7-3-18

INDUSTRIAL HYGIENE RESOURCES REPORTING DATE: 7-5-18

8312 NORTHVIEW, SUITE #100 RECEIPT DATE: 6-29-18

BOISE, ID 83704 CLIENT JOB NO.: 6019

PROJECT TITLE: MHAFB - GUN FIGHTER CLUB - ASB/LEAD INSPECTION

DCMSL PROJECT: IHR5339

PERCENTAGE COMPOSITION BY VISUAL ESTIMATE

TOTAL

DCMSL CLIENT TOTAL PERCENTAGE

SAMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED NUMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS

-16 GFC-CT-4A 6-28-18 A. WHITE PAINT 4.0% ND 0.0 100.0 100.0

B. WHITE CEILING TILE 96.0% ND ____________ 80.0 20.0 100.0

ND

-17 GFC-CT-4B 6-28-18 A. WHITE PAINT 6.0% ND 0.0 100.0 100.0

B. WHITE CEILING TILE 94.0% ND ____________ 80.0 20.0 100.0

ND

-18 GFC-CT-4C 6-28-18 A. WHITE PAINT 5.0% ND 0.0 100.0 100.0

B. WHITE CEILING TILE 95.0% ND ____________ 80.0 20.0 100.0

ND

-19 GFC-S-1A 6-28-18 A. TAN RESIN 5.0% ND 0.0 100.0 100.0

B. TAN TRANSITE 95.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0

4.8

-20 GFC-S-1B 6-28-18 A. TAN RESIN 8.0% ND 0.0 100.0 100.0

B. TAN TRANSITE 92.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0

4.6

-21 GFC-S-1C 6-28-18 A. TAN RESIN 42.0% ND 0.0 100.0 100.0

B. TAN TRANSITE 58.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0

2.9

-22 GFC-F-1A 6-28-18 A. TAN TRANSITE 100.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0 5.0

-23 GFC-F-1B 6-28-18 A. TAN RESIN 3.0% ND 0.0 100.0 100.0

B. TAN TRANSITE 97.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0

111.6

BULK ASBESTOS TEST REPORT

CLIENT: ANALYSIS DATE: 7-3-18

INDUSTRIAL HYGIENE RESOURCES REPORTING DATE: 7-5-18

8312 NORTHVIEW, SUITE #100 RECEIPT DATE: 6-29-18

BOISE, ID 83704 CLIENT JOB NO.: 6019

PROJECT TITLE: MHAFB - GUN FIGHTER CLUB - ASB/LEAD INSPECTION

DCMSL PROJECT: IHR5339

PERCENTAGE COMPOSITION BY VISUAL ESTIMATE

TOTAL

DCMSL CLIENT TOTAL PERCENTAGE

SAMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED NUMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS

-24 GFC-F-1C 6-28-18 A. TAN TRANSITE 100.0% CHRYSOTILE [5-10] 5.0 ____________ 0.0 95.0 100.0 5.0

-25 GFC-DW-1D 6-28-18 A. WHITE TEXTURE 0.5% ND 0.0 100.0 100.0

B. WHITE FIBROUS/YELLOW MASTIC (I) 4.0% ND 90.0 10.0 100.0

C. MULTICOLORED PAINT 8.0% ND 0.0 100.0 100.0

D. TAN FIBROUS 10.0% ND 100.0 0.0 100.0

E. WHITE DRYWALL 77.5% ND ____________ 1.0 99.0 100.0

ND

-26 GFC-DW-1E 6-28-18 A. WHITE TEXTURE 0.5% ND 0.0 100.0 100.0

B. MULTICOLORED PAINT 5.0% ND 0.0 100.0 100.0

C. TAN FIBROUS 10.0% ND 100.0 0.0 100.0

D. WHITE DRYWALL 84.5% ND ____________ 1.0 99.0 100.0

ND

-27 GFC-DW-1F 6-28-18 A. WHITE TEXTURE 0.5% ND 0.0 100.0 100.0

B. MULTICOLORED PAINT 15.0% ND 0.0 100.0 100.0

C. GREY TEXTURE 20.0% ND 0.0 100.0 100.0

D. TAN FIBROUS 22.0% ND 100.0 0.0 100.0

E. WHITE DRYWALL 42.5% ND ____________ 1.0 99.0 100.0

ND

-28 GFC-TW-1A 6-28-18 A. TAN PAINT 8.0% ND 0.0 100.0 100.0

B. GREY CONCRETE PLASTER 92.0% ND ____________ 0.0 100.0 100.0

ND

-29 GFC-TW-1B 6-28-18 A. TAN PAINT 6.0% ND 0.0 100.0 100.0

B. GREY CONCRETE PLASTER 94.0% ND ____________ 0.0 100.0 100.0

BULK ASBESTOS TEST REPORT

CLIENT: ANALYSIS DATE: 7-3-18

INDUSTRIAL HYGIENE RESOURCES REPORTING DATE: 7-5-18

8312 NORTHVIEW, SUITE #100 RECEIPT DATE: 6-29-18

BOISE, ID 83704 CLIENT JOB NO.: 6019

PROJECT TITLE: MHAFB - GUN FIGHTER CLUB - ASB/LEAD INSPECTION

DCMSL PROJECT: IHR5339

PERCENTAGE COMPOSITION BY VISUAL ESTIMATE

TOTAL

DCMSL CLIENT TOTAL PERCENTAGE

SAMPLE SAMPLE SAMPLE PERCENT ASBESTOS ASBESTOS OTHER FIBROUS NON-FIBROUS IDENTIFIED NUMBER NUMBER DATE DESCRIPTION OF SAMPLE TYPE RANGE % IN SAMPLE CONSTITUENTS CONSTITUENTS MATERIALS

-30 GFC-TW-1C 6-28-18 A. BLUE FOAM 10.0% ND 0.0 100.0 100.0

B. TAN PAINT 40.0% ND 0.0 100.0 100.0

C. GREY CONCRETE PLASTER 50.0% ND ____________ 0.0 100.0 100.0

ND

FOR CALCULATION PURPOSES, TRACE (TR) IS ASSUMED TO BE 0.5%.

(I) INSEPARABLE LAYERS ND - NONE DETECTED

THE SAMPLES WERE RECEIVED IN ACCEPTABLE CONDITION. THIS TEST REPORT RELATES ONLY TO THE ITEMS TESTED. THIS REPORT MAY NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF THE LABORATORY.

Appendix C- Consultant’s Certifications

Certificate of Completion

Has attended and successfully completed the Asbestos Building Inspector

AHERA 4 Hours Refresher Training Course In accordance with Title II of TSCA

40 CFR Part 763, Appendix C to Subpart E Consistent with Utah Administrative Rule R307-801: Asbestos

Course Date: 4/13/2018 Certificate Number: 5892-11 ________________________________________ Expiration Date: 4/13/2019 Instructor: Harry Beaulieu

Industrial Hygiene Resources – 8312 W. Northview, Suite 100 – Boise, Idaho 83704 Tel: (208) 323-8287 Fax: (208) 323-0783

Limitations/Disclaimer

The scope of the investigation described in this report has been limited by agreement of the parties based upon financial and other considerations. Further, the scope of this report is limited to the matters expressly covered herein. The investigation, testing and analysis of compounds and materials at the site have been limited to those compounds and materials set out in the parties’ agreement. Other compounds or materials not tested for could be present at the site.

The investigation, testing and analysis described in this report has been undertaken and performed in a professional manner in accordance with generally accepted practices, using the degree of skill and care ordinarily exercised by a Diplomat of the American Board of Industrial Hygiene (ABIH); a “Certified Industrial Hygienist (CIH)”.

During the investigation and in preparing this report we have relied upon information provided by third parties, including independent laboratories and testing services (with appropriate accreditations). It is believed that the information obtained from others during the investigation is reasonable. However, it is not warranted or guaranteed that the information provided by others is complete or accurate.

The investigation and this report are limited to the conditions present at the time of the site visits and inspections, and to the information available at the time this report was prepared.

However, there is a distinct possibility that conditions, compounds or materials may exist which could not be identified within the agreed scope of this investigation or which were not apparent during site inspections or testing. Should any additional information become available, or should additional site work be undertaken, consultant should be notified so that we can determine if modification should be made to this report.

Where indicated or implied in this report, or where mandated by the condition of the site including its structure/improvements, the conclusions of this report are based on visual observations of the site. The conclusions of this report do not apply to any areas of the site not available for inspection or testing.

It should be recognized that the investigation and evaluation of environmental conditions is a science and an art. Judgments leading to conclusions and recommendations are at times made with an incomplete knowledge of all conditions applicable to the site. More detailed, focused and/or extensive studies can tend to reduce the inherent uncertainties associated with the evaluation of environmental conditions. No warranty, express or implied, is given.

This report is prepared for and intended for the exclusive use of the company, organization or individual to whom it is addressed. It may not be used or relied upon in any manner or for any purpose whatsoever by any other party without written authorization by IHR.

IHR5339-FINAL.pdf
IHR5339
BULKN

Scanned Document(1)

Rebecca Ellis-Asbestos Inspector-Exp 4-13-19.pdf
Certificate of Completion
Rebecca Ellis

File details come from the government source that posted it.