Attach_2_-_Drawings.pdf

PDF 20 MB Posted

Attached to
307th BW HQ Renovation Federal contract opportunity
Solicitation number
FA4608-17-R-0021
Issued by
Department of the Air Force Global Strike Command

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to 307th BW HQ Renovation, newest first.
File Type Posted
307th_BW_HQ_Reno_Site_Visit_Q_&_A_.pdf PDF
307th_Site_Visit.pdf PDF
Attach_6_-_Special_Contract_Requirements.pdf PDF
Attach_5_-_Insurance_Form.pdf PDF
Attach_8_-_Past_Performance_Questionnaire.pdf PDF
Attach_3_-_Environmental_Req'ts_(Jun_16).pdf PDF
FA4608-17-R-0021_-_307th_BW_HQ.pdf PDF
Attach_1_-_Specifications.pdf PDF
Attach_7_-_PPQ_Cover_Letter.pdf PDF
Attach_9_-_Wage_Determination.pdf PDF
Attach_4_-_AF66.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A1

MATERIAL INDEX

PROJECT LOCATION MAP

DRAWING INDEX

ARCHITECTURAL

A3.1 A3.2 A3.3

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

3.14.17

S

E

C

U

R

IT

Y

FLIGHTLINE

LINDBERGH

T

W

I N

I N

G

L

U

K

E

D

A

V

I

S

C O

N V

O

Y

W

I

L

B

U

R

W

I

G

H

T

C

U

R

T

I S

S

S

P

A

A

T

Z

K

E

N

N

E

Y

L

A

N

G

L

E

Y

S

H

R

E

V

E

P

O

R

T

B

O

S

S

I

E

R

S

E

L

F

R

I

D

G

E

B A

R K

S D

A L E

H

A

P

N

O

L

D

E

A

R

H

A

R

T

B

O

N

G

I C

A R

U S

D

O

U

H

E

T

L

O

G

I S

T

I C

S

I

E

K

E

R

L

O

U

I

S

I

A

N

A

R

E

A

D

I N

E

S

S

C

H

E

N

N

A

U

L

T

FOULOIS

M

O

N

T

G

O

L

F

I

E

R

R

I

C

K

E

N

B

A

C

K

E

R

B

I

L

L

Y

M

I

T

C

H

E

L

L

F A

I R

C H

I L D

D

A

E

D

A

L

U

S

V A

N D

E N

B E

R G

O R

V I L

I G

H T

C H

A P

P

J

M E

S

B

L V

D

N

A

F A

I R

C H

I L D

K E

N N

E Y

V

A

N

D

E

N

B

E

R

G

F

A

I

R

C

H

I

L

D

F

A

I

R

C

H

I

L

D

S H

R E

V E

P O

R T

N

A

R I C

K E

N B

A C

K E

R

K

E

N

N

E

Y

N A

N

A

V

A

N

D

E

N

B

E

R

G

B I L

Y

T

C H

E L L

O

R

V

I

L

I

G

H

T

D

O

U

H

E

T

R

I

C

K

E

N

B

A

C

K

E

R

B

O

S

S

I

E

R

DAVIS

S

E

C

U

R

I T

Y

ENLARGED SITE PLAN

MD1.0

MECHANICAL

MD1.1

ED1.0

ED1.1

ELECTRICAL

A3.4

A8.1 A8.2

A4.1 A5.1

A5.4

M1.0

M2.0 M2.1 M3.0

E1.0 E2.0 E2.1 E3.0 E3.1 E4.0 E4.1 E5.0

M3.1 M4.0

M1.1

ABBREVIATIONS

M6.0 M6.1

A7.1

E5.1 E5.2

SYMBOLS LEGEND

INTERIOR DESIGN

ID1

ID2

ID3

MS1.0

M4.1 M5.0

FIRE PROTECTION

FP1.0

FP1.1

A5.2 A5.3

ADDITIVE ALTERNATE NO. 1

FA4608-17-R-0021

Attachment 2

FIRST FLOOR DEMOLITION PLAN

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

3.14.17

DEMOLITION NOTES

GENERAL NOTES

WALL TYPE LEGEND

FURNITURE DEMOLITION NOTES

FA4608-17-R-0021

SECOND FLOOR DEMOLITION PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

TEXT INFO

TEXT

DETAIL

A-

RKF

WKB

DETAIL ELEVATION

ELEVATIONDETAIL

DEMOLITION NOTES

GENERAL NOTES

WALL TYPE LEGEND

FURNITURE DEMOLITION NOTES

FA4608-17-R-0021

FIRST FLOOR PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

CONSTRUCTION NOTES

WALL TYPES

GENERAL NOTES

WALL TYPE LEGEND

A/C CONCRETE PAD DETAIL

HRCU-1 HRCU-2 OACU-1HRCU-3

FA4608-17-R-0021

SECOND FLOOR PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

CONSTRUCTION NOTES

WALL TYPES

TEXT INFO

TEXT

DETAIL

A-

RKF

WKB

DETAIL ELEVATION

ELEVATIONDETAIL

GENERAL NOTES

WALL TYPE LEGEND

FA4608-17-R-0021

NORTHEAST ELEVATION - (FRONT ELEVATION)

WORK 318-673-9980 FAX 318-673-9982

3.14.17

SOUTHWEST ELEVATION - (REAR ELEVATION)

SOUTHEAST ELEVATION NORTHWEST ELEVATION

WATERPROOFING NOTES

FA4608-17-R-0021

WORK 318-673-9980 FAX 318-673-9982

3.14.17

DOOR REFERENCE SCHEDULE

HEAD

JAMB

ELEVATION

DOOR AND FRAME ELEVATION

HEAD

JAMB

DETAIL

SECOND FLOOR

FIRST FLOOR

ELEVATION ELEVATION

DOOR AND FRAME NOTES:

ELEVATION

ELEVATION

DOOR AND HARDWARE NOTES

HEAD

JAMB

ADDITIVE ALTERNATE NO. 1

FA4608-17-R-0021

FIRST FLOOR EXISTING DOOR LOCATION PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

EXISTING FIRST FLOOR DOOR SCHEDULE

CONSTRUCTION NOTES

ADDITIVE ALTERNATE NO. 1

DOOR AND HARDWARE NOTES

FA4608-17-R-0021

3.14.17

TEXT INFO

TEXT

DETAIL

A-

RKF

WKB

DETAIL ELEVATION

ELEVATIONDETAIL

SECOND FLOOR EXISTING DOOR LOCATION PLAN

EXISTING SECOND FLOOR DOOR SCHEDULE

ADDITIVE ALTERNATE NO. 1

DOOR AND HARDWARE NOTES

FA4608-17-R-0021

3.14.17

FIRST FLOOR SIGN SCHEDULE

TYPICAL SIGN DETAILS

OFFICE

STAIR

CONFERENCE

UNOCC PIED

DOOR SIGN LOCATION

CONFERENCE

RESTROOM

OFFICE

FIRE STAIR

SECOND FLOOR SIGN SCHEDULE

RESTROOM

OFFICE

OFFICE

FA4608-17-R-0021

3.14.17

TYPICAL WALL SECTION

DETAIL

FA4608-17-R-0021

FIRST FLOOR REFLECTED CEILING PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

WALL TYPE LEGEND

REFLECTED CEILING PLAN NOTES:

TYP. WALL TO CEILING

TYP. INSTALLATION DETAILS

HOLD DOWN CLIP DETAIL

FA4608-17-R-0021

SECOND FLOOR REFLECTED CEILING PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

TEXT INFO

TEXT

DETAIL

A-

RKF

WKB

DETAIL ELEVATION

ELEVATIONDETAIL

WALL TYPE LEGEND

REFLECTED CEILING PLAN NOTES:

TYP. WALL TO CEILING

TYP. INSTALLATION DETAILS

HOLD DOWN CLIP DETAIL

CONSTRUCTION NOTES:

FA4608-17-R-0021

FIRST FLOOR FURNITURE PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

FOR REFERENCE ONLY

FA4608-17-R-0021

SECOND FLOOR FURNIURE PLAN

WORK 318-673-9980 FAX 318-673-9982

3.14.17

FOR REFERENCE ONLY

FA4608-17-R-0021

FIRST FLOOR ROOM FINISH SCHEDULE SECOND FLOOR ROOM FINISH SCHEDULE

CODE MFG. PRODUCT COLOR REMARKSFLOOR

BASE

WALLS

MISC.

SID - INTERIOR FINISHES

CH1, WOOD CHAIR RAIL

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

3.14.17

FA4608-17-R-0021

TYP

TYP

SEE ENLARGED MECHANICAL

ROOM PLAN THIS SHEET.

EXISTING AIR COOLED

CHILLER AND ASSOCIATED

PIPING TO BE REMOVED

EXISTING CONDENSER AND

ASSOCIATED PIPING TO BE REMOVED

CWS

C W

S

CWS

CWS

CWR

HWS

HWR

CWR

HWR

HWS

9" FLUE

BOILER

P-1

P-2

EXPANSION TANK

F-2

F-3

AIR

SEPARATOR

4" FLUE

WATER HEATER

TO AHU-1

TO AHU-1

EXTG HW, CW, HWR TO/FROM

MECHANICAL ROOM

2 1/2"CW

1 1/4"HW

3/4"HWR

3/4"CW, HW, HWR

3"SS

3"SS

4"SS

4"SS

EXTG 2"V UP

EXTG 2"V ABV CLG

CAP TOILET WASTE BACK TO MAIN;

FINISH FLOOR TO MATCH ADJACENT

FINISH OR AS DIRECTED BY ARCHITECT

3"SS

EXTG 2"V

ABV CLG

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

1. EXISTING FIXTURES TO BE REPLACED (RE: SHEET M2.0).

RETAIN EXISTING WASTE, WATER AND VENT FOR REUSE.

2. ALL EXISTING VAV, LINEAR SLOT DIFFUSERS, RETURN AIR

DIFFUSERS, AND ASSOCIATED PIPING, DUCTWORK, AND

CONTROLS TO BE REMOVED.

3. EXISTING CHILLED WATER & BOILER ACCESSORIES,

EQUIPMENT, PIPING, CONTROLS, ETC. TO BE REMOVED.

4. EXISTING FIXTURES TO REMAIN. PROTECT DURING

DEMOLITION AND CONSTRUCTION.

5. EXISTING PLUMBING FIXTURES TO BE REMOVED. RETAIN

WASTE AND WATER BRANCHES FOR REUSE (RE: SHEET

M4.0) .

SCALE: 1/8"=1'-0"

LEGEND

EXISTING TO REMAIN

EXISTING TO BE REMOVED

SCALE: 1/4"=1'-0"

SCALE: 1/8"=1'-0"

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text

EXIST BUSHES TO REMAIN

AutoCAD SHX Text

EXIST SIDEWALK

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

%%UMECHANICAL NOTES%%U:

AutoCAD SHX Text

FIRST FLOOR HVAC DEMOLITION PLAN

AutoCAD SHX Text

FIRST FLOOR MECHANICAL DEMOLITION PLAN

AutoCAD SHX Text

MD1.0

AutoCAD SHX Text

ENLARGED MECHANICAL ROOM

AutoCAD SHX Text

FIRST FLOOR PLUMBING DEMOLITION PLAN

EXISTING RESTROOM

FIXTURES TO REMAIN.

PROTECT DURING

CONSTRUCTION PHASE.

SEE ENLARGED MECHANICAL

ROOM PLAN THIS SHEET.

TYP

TYP

9" FLUE

4" FLUE

22"Ø DN TO

1ST FLR

O/A PLENUM

COMPRESSOR

AHU-1

AHU-2

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

1. EXISTING FIXTURES TO BE REPLACED (RE: SHEET M2.1).

RETAIN EXISTING WASTE, WATER AND VENT FOR REUSE.

2. ALL EXISTING VAV, LINEAR SLOT DIFFUSERS, RETURN AIR

DIFFUSERS, AND ASSOCIATED PIPING, DUCTWORK, AND

CONTROLS TO BE REMOVED.

3. EXISTING CHILLED WATER PIPING, AIR HANDLERS,

COMPRESSOR, COMPRESSED AIR PIPING, CONTROLS, ETC.

TO BE REMOVED.

SCALE: 1/8"=1'-0"

LEGEND

EXISTING TO REMAIN

EXISTING TO BE REMOVED

SCALE: 1/4"=1'-0"

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

%%UMECHANICAL NOTES%%U:

AutoCAD SHX Text

SECOND FLOOR MECHANICAL DEMOLITION PLAN

AutoCAD SHX Text

SECOND FLOOR MECHANICAL DEMOLITION PLAN

AutoCAD SHX Text

MD1.1

ENLARGED MECHANICAL ROOM

EXISTING WATER MAIN

121-2 FH

121-3 FH

121-1 FH

E X

I S

T I N

G

W

A T

I N

E X

I S

T I N

G

W

A T

I N

F

F

F

F

EXISTING FIRE MAIN

NEW 6" FIRE

F

F

F

SEE SHEET FP1.0

FOR CONTINUATION

6"

6"

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

SCALE: 1"=40'-0"

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

MECHANICAL SITE PLAN

AutoCAD SHX Text

MECHANICAL SITE PLAN

MS1.0

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

MECHANICAL LEGEND

SYMBOL DESCRIPTION

SUPPLY AIR DIFFUSER OR DUCT

RETURN AIR GRILLE, REGISTER OR DUCT

EXHAUST AIR GRILLE, REGISTER OR DUCT

DOUBLE WALL INSULATED DUCT (PERF LINER)

DUCT ELBOW WITH TURNING VANES

MANUAL VOLUME DAMPER

THERMOSTAT/TEMPERATURE SENSOR

DUCT TRANSITION

MECHANICAL GENERAL NOTES

CONTRACTOR SHALL PROVIDE COMPLETE AND WORKABLE HVAC SYSTEMS IN ACCORDANCE WITH BUT

NOT LIMITED TO THE PLANS AND SPECIFICATIONS. COMPLY WITH LATEST EDITIONS OF ALL APPLICABLE

CODES INCLUDING NFPA 101:9.2, 90A AND 90B. OBTAIN ALL PERMITS AND PAY ALL REQUIRED FEES.

REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF GRILLES AND

DIFFUSERS IN CEILINGS AND WALLS.

FIRE DAMPERS WHERE REQUIRED SHALL BE DYNAMIC TYPE. PROVIDE ACCESS DOORS AS REQUIRED.

DUCT SIZES TO DIFFUSERS, GRILLES AND REGISTERS SHALL BE SAME SIZE AS INLET/NECK SIZE.

BRANCH HIGH PERFORMANCE TAKEOFFS SHALL BE SAME SIZE AS DIFFUSER NECKS UNLESS

OTHERWISE NOTED.

PROVIDE ACCESS DOORS AT GYPSUM BOARD CEILINGS AND INACCESSIBLE WALLS FOR DAMPER AND

VALVE ACCESS. COORDINATE LOCATIONS & SUBMIT TO ARCHITECT FOR REVIEW BEFORE

INSTALLATION.

SECURE DIFFUSERS AND GRILLES TO T-BAR OR CEILINGS. SUBMIT SHOP DRAWINGS FOR APPROVAL

PRIOR TO STARTING WORK.

INSULATED PIPING AND FITTINGS EXPOSED TO VIEW, THROUGHOUT THE FACILITY, SHALL BE COVERED

& FINISHED WITH PVC JACKET EQUAL TO MANVILLE CEEL-CO PIPE JACKETING SYSTEM USING 30 MIL

THICK JACKET. FITTINGS, FLANGES, VALVES & ACCESSORIES SHALL BE JACKETED. INSTALL PER

MANUFACTURER'S INSTRUCTIONS WITH SEAM ON TOP OF PIPE SO AS NOT TO BE VISIBLE FROM

OCCUPIED SPACE. FINISH PAINT, VERIFY COLOR WITH ARCHITECT.

DUCTWORK SHALL BE SUPPORTED IN ACCORDANCE WITH APPLICABLE STANDARDS SET FORTH IN THE

INTERNATIONAL MECHANICAL CODE.

DUCTWORK SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH SMACNA GUIDELINES FOR SEISMIC

RESTRAINT.

WHERE MECHANICAL EQUIPMENT IS LOCATED IN ELECTRICAL ROOMS, COORDINATE EXACT LOCATION

WITH ELECTRICAL SHOP DRAWINGS PRIOR TO MOUNTING OR HANGING MECHANICAL EQUIPMENT OR

ROUTING PIPING. NO EQUIPMENT OR PIPING SHALL BE LOCATED OR ROUTED ABOVE ELECTRICAL

GEAR.

DUCT SYSTEMS FABRICATION AND INSTALLATION SHALL CONFORM IN ALL RESPECTS WITH THE

INTERNATIONAL MECHANICAL CODE. DUCT INSULATION (WRAP & LINER, AS INDICATED) MATERIALS AND

INSTALLATION SHALL COMPLY WITH THE INTERNATIONAL MECHANICAL CODE. PROVIDE FLEXIBLE

CONNECTIONS AT ALL SUPPLY AND RETURN CONNECTIONS ON A/C UNITS AND AT ALL EXHAUST FANS.

SUPPLY AIR DUCT FOR A MINIMUM OF FIRST 10 FEET AT AIR HANDLER DISCHARGE, ALL EXPOSED

SUPPLY AIR DUCTS, AND ALL RETURN DUCTS SHALL BE INSULATED DOUBLE WALL CONSTRUCTION

WITH PERFORATED INTERIOR LINING. REMAINDER OF ALL DUCT SYSTEMS (R/A, E/A AND S/A) SHALL BE

EXTERNALLY WRAPPED WITH STANDARD DUCT INSULATION.

FLEXIBLE DUCT SHALL BE R8 MINIMUM AND SHALL EXTEND FROM DIFFUSER NOT MORE THAN 5'-0" OR

AS DIRECTED BY LOCAL BUILDING INSPECTOR, FREE OF KINKS AND SAME SIZE AS DIFFUSER NECK.

ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR.

UNDER NORMAL ANTICIPATED OPERATING CONDITIONS (WITH DOORS CLOSED, AS APPLICABLE), ROOM

RETURN AIRFLOWS SHALL BE EQUAL TO ROOM SUPPLY AIRFLOWS, UNLESS NOTED OTHERWISE.

PROVIDE DUCT-MOUNTED SMOKE DETECTOR IN SUPPLY AND RETURN DUCT OF ALL AIR HANDLING

DEVICES OF FIVE TON NOMINAL SIZE AND ABOVE, OR 2000 CFM AND OVER, OR SERVING A MEANS OF

EGRESS. UPON ACTIVATION OF SMOKE DETECTOR, FAN MOTOR SHALL SHUT DOWN, AUDIO/VISUAL

ALARM SHALL BE INITIATED IN A NORMALLY OCCUPIED SPACE. PROVIDE REMOTE-MOUNTED ALARM

TEST STATION. INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 90A, INTERNATIONAL

MECHANICAL CODE AND THE AUTHORITY HAVING JURISDICTION. AS APPLICABLE, COORDINATE

COMPONENT PROVISIONS AND INSTALLATION WITH FIRE ALARM SUPPLIER AND SUBCONTRACTOR.

PROVIDE FIRE-STAT IN RETURN DUCT OF AIR HANDLING DEVICES UNDER 2000 CFM. UPON ACTIVATION

OF FIRE-STAT, FAN MOTOR SHALL SHUT DOWN. INSTALLATION SHALL BE IN ACCORDANCE WITH

INTERNATIONAL MECHANICAL CODE AND THE AUTHORITY HAVING JURISDICTION.

CONTRACTOR SHALL FIELD VERIFY LOCATION OF ROOF MOUNTED OR ATTIC MOUNTED EQUIPMENT TO

AVOID CUTTING ANY EXISTING STRUCTURAL MEMBERS. JOIST SHALL NOT BE CUT WITHOUT THE

WRITTEN APPROVAL OF THE ENGINEER.

VERIFY FINAL LOCATION OF THERMOSTAT OR OTHER TEMPERATURE CONTROL DEVICE WITH

OWNER/ARCHITECT PRIOR TO INSTALLATION. PROVIDE CLEAR LOCKING COVERS. WHERE UNABLE TO

BE CONCEALED WITHIN OR BY THE BUILDING CONSTRUCTION, ANY ASSOCIATED EXPOSED, LOW

VOLTAGE CONTROL WIRING WITHIN THE BUILDING INTERIOR SHALL BE INSTALLED WITHIN CONDUIT

AND PAINTED TO MATCH INTERIOR FINISHES.

EQUIPMENT DIMENSIONS ARE BASED ON PRODUCTS SCHEDULED. REFER TO SPECIFICATIONS FOR

ACCEPTABLE MANUFACTURERS AND REQUIREMENTS.

FOR INTERIOR, PROVIDE INSULATED FULL SIZE (OR SIZE AS NOTED) COPPER CONDENSATE DRAIN

FROM ALL COOLING COILS TO AS INDICATED. TERMINATE OPEN SITE. FOR EXTERIOR (ROOF), PROVIDE

FULL SIZE (OR SIZE AS NOTED) "PAINTED" SCHEDULE 80 PVC CONDENSATE DRAIN FROM ALL HVAC UNIT

CONDENSATE CONNECTIONS; EXTEND AND TERMINATE AT ROOF DRAIN OR AS NOTED.

COORDINATE INSTALLATION OF EQUIPMENT, DUCTS AND PIPING WITH OTHER TRADES. INFORM

ARCHITECT/ENGINEER OF INTERFERENCES.

VERIFY ALL OUTSIDE AIR INTAKE AND EXHAUST LOCATIONS WITH ARCHITECT. VERIFY STYLE AND

COLOR OF ALL OUTSIDE AIR INTAKE AND EXHAUST LOUVERS WITH ARCHITECT. PAINT TO MATCH FINAL

ADJACENT BUILDING FINISH UNLESS DIRECTED OTHERWISE. OUTSIDE AIR INTAKES SHALL BE LOCATED

A MINIMUM OF 10'-0" FROM ANY EXHAUST OR VTR. INTAKES SHALL REMAIN CLOSED UNTIL AIR

BALANCING PHASE.

EQUIPMENT START-UP SHALL BE BY MANUFACTURER'S AUTHORIZED REPRESENTATIVES.

CONTRACTOR SHALL INSTALL NEW FILTERS (MERV 8, MINIMUM) IN ALL AIR HANDLERS AFTER

COMPLETION OF ALL CONSTRUCTION AND FINAL TEST AND BALANCE AND PRIOR TO OWNER

OCCUPANCY. PROVIDE A MINIMUM OF 2 SETS OF SPARES FOR EACH UNIT.

EQUIPMENT, CONTROLS AND REFRIGERANT LINES SHALL BE INSTALLED IN ACCORDANCE WITH

MANUFACTURER'S RECOMMENDATIONS.

WHERE VISIBLE TO PUBLIC VIEW, PRIME/PAINT ALL ASSOCIATED EXPOSED MECHANICAL SYSTEM COMPONENTS TO MATCH ADJACENT FINISHES, UNLESS DIRECTED OTHERWISE BY ARCHITECT. ALL ASSOCIATED FIELD PAINTING UNLESS DIRECTED OTHERWISE SHALL BE BY A PAINTING CONTRACTOR;

COORDINATE IN ADVANCE AS REQUIRED.

PRIOR TO ORDER, CONTRACTOR SHALL COORDINATE AND VERIFY ALL EXACT EQUIPMENT POWER

PROVISIONS AND REQUIREMENTS WITH CORRESPONDING ELECTRICAL PLANS. CONTRACTOR SHALL BE

RESPONSIBLE FOR ALL ASSOCIATED CONTROL WIRING AND THE COORDINATION OF ALL SUPPLY

POWER.

M MOTORIZED VOLUME DAMPER

CONDENSATE DRAIN PIPINGC

DUCT SMOKE DETECTOR

T

AIR DISTRIBUTION DEVICE SCHEDULE

MARK DESCRIPTION MOUNTING MANUFACTURER'S

CATALOG NO. MATERIAL FINISH ACCESSORIES / REMARKS

D1 CEILING SUPPLY

DIFFUSER SURFACE PRICE ASCD ALUM WHITE BAKED

ENAMEL

24x24 SQUARE 3-CONE DIFFUSER, 4-WAY

THROW, NECK SIZE AS INDICATED

D2 CEILING SUPPLY

DIFFUSER SURFACE PRICE ASCD ALUM WHITE BAKED

ENAMEL

12x12 SQUARE 3-CONE DIFFUSER, 4-WAY

THROW, NECK SIZE AS INDICATED

G1 CEILING RETURN

GRILLE SURFACE PRICE 80FF ALUM WHITE BAKED

ENAMEL

1/2 x 1/2 x 1/2 GRID EGG CRATE CORE, 24/24 PANEL SIZE, FILTER RETURN

G2 CEILING EXHAUST

GRILLE SURFACE PRICE 80D ALUM WHITE BAKED

ENAMEL

1/2 x 1/2 x 1/2 GRID EGG CRATE CORE, 12/12 PANEL SIZE, OBD

G3 CEILING RETURN

GRILLE SURFACE PRICE 80FF ALUM WHITE BAKED

ENAMEL

1/2 x 1/2 x 1/2 GRID EGG CRATE CORE, 24/12 PANEL SIZE, FILTER RETURN

G4

CEILING RETURN

GRILLE SURFACE PRICE 80FF ALUM WHITE BAKED

ENAMEL

1/2 x 1/2 x 1/2 GRID EGG CRATE CORE, 12/12 PANEL SIZE, FILTER RETURN

G5

CEILING RETURN

GRILLE LAY-IN PRICE 80FF ALUM WHITE BAKED

ENAMEL

1/2 x 1/2 x 1/2 GRID EGG CRATE CORE, 24/24 PANEL SIZE, FILTER RETURN

VERIFY EXACT DEVICE TYPE/FINISH WITH ALL CEILING PER ARCHITECTURAL PLANS PRIOR TO ORDER AND INSTALLATION. ALTERNATE ACCEPTABLE MANUFACTURERS: TUTTLE & BAILEY, TITUS, KRUEGER, METALAIRE OR APPROVED EQUAL. OPPOSED BLADE DAMPERS AS

SCHEDULED SHALL BE OMITTED FOR TRANSFER AIR DUCT APPLICATIONS ONLY.

REFRIGERANT PIPING (3-PIPE)

REFRIGERANT PIPING (2-PIPE)

DEDICATED OUTDOOR AIR UNIT SCHEDULE

MARK MODEL NO.

(DAIKIN)

O/A

(CFM)

SUPPLY FAN EXHAUST FAN COOLING HEATING

ENERGY RECOVERY

HEAT PUMP

CFM HP ESP

(") CFM HP ESP

TOTAL

CAP

(BTUH)

SENS

CAP

(BTUH)

EAT

(DB/WB)

LAT

(DB/WB) KW

EAT

(DB)

MEDIA

TYPE

ENTERING

AIR

SUMMER WINTER

TOTAL ENERGY

RECOVERED

(BTUH)

NOMINAL CAPACITY

COMPRESSOR

TYPE

IEER

MODEL

(DAIKIN)

EAT

(DB/WB)

LAT

(DB/WB)

EAT

(DB/WB)

LAT

(DB/WB) COOLING HEATING

OAU-1 CAH009 3500 3500 5 2.25 2500 3 1.25 211.30 114.6 83.7/71.6 53.8/52.9 25 53.1

FIXED

PLATE

3500 95.0/78.0 83.7/71.6 25.0/20.0 53.1/44.4 96.4 228.0 256.0 SCR 20.8 RXYQ240TATJU

*CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER AND INSTALLATION.

NOTES:

A. CONNECT TO THE VRV SYSTEM AND BUILDING I-TOUCH MANAGER USING AN AHU INTEGRATION KIT.

EXHAUST FAN

SUPPLY AIR

RETURN AIR

EXHAUST AIR

OUTSIDE AIR

ABOVE FINISHED FLOOR

VARIABLE REFRIGERANT VOLUME UNIT

EF

S/A

R/A

E/A

O/A

AFF

VRV

HEAT RECOVERY CONDENSING UNIT

HRCU

FAN COIL UNIT

FCU

A-AIR DEVICE, B-NECK SIZE, C-AIRFLOW

VRV BRANCH SELECTOR MODULE

BS

OUTSIDE AIR UNIT

OAU

A B

C

SYMBOL DESCRIPTION

VRV SCHEDULE

MARK

OUTDOOR UNIT

(DAIKIN)

COOLING

CAPACITY

HEATING

CAPACITY

BRANCH

SELECTORS

(DAIKIN)

UNIT

TAGS

INDOOR UNITS

(DAIKIN)

INDOOR UNIT

TAGS

AIRFLOW

(CFM)

COOLING

CAPACITY (BTUH) NOTES

TOTAL SENSIBLE

HEAT

RECOVERY

(1) HRCU-1

REYQ432TTJU,

3 MODULES (A -

144, B - 144, C-144)

427.2 386.6

BSQ36TVJ BS-1

FCU-1-8 FXMQ18PBVJU 635 14700 12300

A,B,C,D

FCU-1-9 FXEQ09PVJU 254 6300 5700

A,B,C,D

FCU-1-10 FXEQ07PVJU 212 4700 4100

A,B,C,D

FCU-1-11 FXEQ07PVJU 212 6200 3100

A,B,C,D

BSQ60TVJ BS-2

FCU-1-23 FXEQ07PVJU 212 3700 2900

A,B,C,D

FCU-1-24 FXEQ07PVJU 212 4900 4300

A,B,C,D

FCU-1-25 FXEQ12PVJU 304 7600 6400

A,B,C,D

FCU-1-26 FXEQ07PVJU 212 3300 2700

A,B,C,D

FCU-1-12 FXMQ09PBVJU 317 7800 6000

A,B,C,D

- FCU-1-7 FXFQ12TVJU 436 9000 6850

A,B,C,D

- - FCU-1-6 FXAQ07PVJU 260 3000 2650

A,B,C,D

BSQ60TVJ BS-3

FCU-1-13 FXMQ09PBVJU 317 6400 4800

A,B,C,D

FCU-1-14 FXZQ07MVJU9 320 4600 3400

A,B,C,D

FCU-1-15 FXEQ07PVJU 212 3400 2800

A,B,C,D

FCU-1-22 FXEQ07PVJU 212 3400 2800

A,B,C,D

FCU-1-16 FXZQ07MVJU9 320 4900 2500

A,B,C,D

FCU-1-46 FXAQ07PVJU 260 1900 1400

A,B,C,D

BSQ96TVJ BS-4

FCU-1-39 FXMQ54PBVJU 1624 38100 32100

A,B,C,D

FCU-1-38 FXEQ07PVJU 212 4200 3700

A,B,C,D

FCU-1-37 FXEQ09PVJU 254 5500 5300

A,B,C,D

BSQ60TVJ BS-5

FCU-1-40 FXMQ30PBVJU 1094 18500 16300

A,B,C,D

FCU-1-28 FXMQ15PBVJU 560 10400 9400

A,B,C,D

BSQ96TVJ BS-6

FCU-1-17 FXEQ24PVJU 597 14800 12200

A,B,C,D

FCU-1-18 FXEQ07PVJU 212 1500 800

A,B,C,D

FCU-1-21 FXAQ12PVJU 290 9000 7000

A,B,C,D

FCU-1-20 FXEQ09PVJU 254 7400 5900

A,B,C,D

FCU-1-29 FXEQ07PVJU 212 3200 2600

A,B,C,D

FCU-1-30 FXEQ07PVJU 212 5900 4100

A,B,C,D

FCU-1-35 FXEQ07PVJU 212 3400 2700

A,B,C,D

FCU-1-36 FXEQ07PVJU 212 4700 3400

A,B,C,D

BSQ96TVJ BS-7

FCU-1-1 FXMQ36PBVJU 1130 26200 22700

A,B,C,D

FCU-1-2 FXMQ30PBVJU 1094 21800 18100

A,B,C,D

FCU-1-3 FXEQ18PVJU 494 11600 9600

A,B,C,D

FCU-1-4 FXEQ09PVJU 254 6300 5100

A,B,C,D

BSQ60TVJ BS-8 FCU-1-27 FXMQ48PBVJU 1377 34300 19000

A,B,C,D

BSQ96TVJ BS-9

FCU-1-41 FXEQ24PVJU 597 15300 12400

A,B,C,D

FCU-1-42 FXMQ15PBVJU 560 12300 9800

A,B,C,D

FCU-1-43 FXMQ18PBVJU 635 13800 11500

A,B,C,D

FCU-1-44 FXMQ18PBVJU 635 13700 11500

A,B,C,D

BSQ36TVJ BS-10 FCU-1-5 FXMQ18PBVJU 635 14500 12300

A,B,C,D

BSQ60TVJ BS-23

FCU-1-33 FXEQ07PVJU 212 5600 4600

A,B,C,D

FCU-1-34 FXEQ07PVJU 212 1400 900

A,B,C,D

FCU-1-32 FXEQ07PVJU 212 5500 4500

A,B,C,D

FCU-1-19 FXEQ07PVJU 212 2300 1300

A,B,C,D

FCU-1-31 FXEQ07PVJU 212 4800 4200

A,B,C,D

FCU-1-45 FXEQ07PVJU 212 4700 4200

A,B,C,D

BSQ36TVJ BS-24 FCU-1-47 FXEQ07PVJU 212 4200 3100

A,B,C,D

HEAT

RECOVERY

(1) HRCU-2

REYQ312TTJU,

2 MODULES (A -

168, B - 144)

381.3 331.1

BSQ96TVJ BS-11

FCU-2-1 FXEQ09PVJU 254 6300 5700

A,B,C,D

FCU-2-2 FXEQ09PVJU 254 6200 5500

A,B,C,D

FCU-2-3 FXMQ48PBVJU 1377 30000 25900

A,B,C,D

FCU-2-11 FXZQ07MVJU9 320 2800 2500

A,B,C,D

BSQ60TVJ BS-12

FCU-2-12 FXMQ30PBVJU 1094 21200 17900

A,B,C,D

FCU-2-39 FXEQ07PVJU 212 5100 4600

A,B,C,D

FCU-2-40 FXEQ07PVJU 212 3800 3200

A,B,C,D

BSQ60TVJ BS-13 FCU-2-38 FXMQ48PBVJU 1377 33900 29700

A,B,C,D

BSQ96TVJ BS-14 FCU-2-13 FXMQ72MVJU 2048 61700 33700

A,B,C,D

BSQ60TVJ BS-15

FCU-2-4 FXMQ24PBVJU 688 17400 14900

A,B,C,D

FCU-2-5 FXEQ07PVJU 212 3900 3300

A,B,C,D

FCU-2-6 FXEQ12PVJU 304 7300 6700

A,B,C,D

FCU-2-7 FXEQ09PVJU 254 7100 5900

A,B,C,D

BSQ96TVJ B-16

FCU-2-36 FXEQ07PVJU 212 3800 3200

A,B,C,D

FCU-2-37 FXEQ09PVJU 254 5700 5000

A,B,C,D

FCU-2-35 FXMQ18PBVJU 635 14800 12800

A,B,C,D

FCU-2-33 FXEQ07PVJU 212 3700 3100

A,B,C,D

FCU-2-34 FXEQ18PVJU 494 10800 9700

A,B,C,D

FCU-2-30 FXEQ09PVJU 254 7000 5900

A,B,C,D

FCU-2-31 FXEQ07PVJU 212 3500 2900

A,B,C,D

BSQ36TVJ BS-17 FCU-2-32 FXMQ24PBVJU 688 17900 15400

A,B,C,D

- - FCU-2-14 FXMQ54PBVJU 1624 30400 30000

A,B,C,D

HEAT

RECOVERY

(1) HRCU-3

REYQ312TTJU,

2 MODULES (A -

168, B - 144)

308.6 268.1

BSQ96TVJ BS-25

FCU-2-15 FXEQ07PVJU 212 5100 4000

A,B,C,D

FCU-2-16 FXZQ18MVJU9 494 12700 11000

A,B,C,D

FCU-2-17 FXZQ18MVJU9 494 11400 9700

A,B,C,D

FCU-2-18 FXFQ18TVJU 742 15000 13400

A,B,C,D

BSQ96TVJ BS-26 FCU-2-8 FXMQ96MVJU 2543 58000 49400

A,B,C,D

BSQ96TVJ BS-27 FCU-2-9 FXMQ96MVJU 2543 60100 51900

A,B,C,D

BSQ96TVJ BS-28

FCU-2-19 FXMQ30PBVJU 1094 22000 18700

A,B,C,D

FCU-2-20 FXEQ07PVJU 212 4800 4300

A,B,C,D

FCU-2-21 FXEQ24PVJU 597 15000 13000

A,B,C,D

BSQ36TVJ BS-29

FCU-2-10 FXMQ24PBVJU 688 16000 14200

A,B,C,D

FCU-2-22 FXZQ07MVJU9 320 2700 2400

A,B,C,D

BSQ36TVJ BS-30 FCU-2-23 FXMQ30PBVJU 1094 24100 19500

A,B,C,D

BSQ96TVJ BS-31

FCU-2-24 FXEQ09PVJU 254 7100 6100

A,B,C,D

FCU-2-25 FXEQ18PVJU 494 9900 8700

A,B,C,D

FCU-2-26 FXMQ12PBVJU 450 8300 6900

A,B,C,D

FCU-2-27 FXEQ09PVJU 254 6800 5700

A,B,C,D

FCU-2-28 FXEQ18PVJU 494 10200 9000

A,B,C,D

BSQ36TVJ BS-32 FCU-2-29 FXMQ24PBVJU 688 18000 14700

A,B,C,D

ALTERNATE ACCEPTABLE MANUFACTURERS: TRANE, LG, MITSUBISHI, CARRIER, OR PRIOR APPROVED EQUAL.

*CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER AND INSTALLATION.

NOTES:

A. TWINNING KIT REQUIRED, CRANKCASE HEATER, HIGH-PRESSURE SENSOR, HIGH-PRESSOR SWITCH, OVERHEAT PROTECTION, OVERCURRENT PROTECTION, THERMAL SWITCH, LOW AMBIENT, 10-YEAR MANUFACTURER'S WARRANTY. AS PART OF HVAC SHOP DRAWING SUBMITTAL, FOR EXACT VRF CONFIGURATION TO

BE USED, PROVIDE COMPLETE REFRIGERANT PIPING (WITH LENGTHS AND SIZES) AND CONTROLS LAYOUT FOR EVALUATION BY ENGINEER.

B. PROVIDE EACH FAN COIL UNIT (OR FAN COIL UNIT GROUPING, AS APPLICABLE) WITH INDIVIDUAL THERMOSTAT WITH DIGITAL DISPLAY EQUAL TO DAIKIN

BRC1E71 SERIES CONTROLLER. INTERLOCK ALL CONTROLLERS OF BOTH SYSTEMS TO ONE DAIKIN "I-TOUCH" CENTRAL BUILDING CONTROLLER; FIELD VERIFY

EXACT LOCATION WITH OWNER PRIOR TO ROUGH-IN AND INSTALLATION.

C. FAN COIL UNITS SHALL ALL BE PROVIDED WITH INTEGRAL CONDENSATE PUMP, UNLESS NOTED OR SPECIFIED OTHERWISE. EACH SUSPENDED FCU SHALL BE

PROVIDED WITH INTEGRAL FACTORY-MOUNTED FLOAT SWITCH. OTHERWISE, PROVIDE INDIVIDUAL FLOAT SWITCH IN EMERGENCY DRAIN PAN AND INTERLOCK

FOR UNIT SHUTDOWN.

D. PROVIDE INLINE SERVICE SHUT-OFF VALVES UPSTREAM OF EACH BRANCH SELECTOR AND DOWNSTREAM OF BRANCH SELECTOR IF MULTIPLE UNITS ARE

USED.

E. FOR ALL DUCTED-CONCEALED FAN COIL UNITS ABOVE LAY-IN CEILINGS, DIRECTLY BENEATH FILTER ACCESS SIDE OF FAN COIL UNIT, ON BOTTOM OF METAL

LAY-IN CEILING GRID/TRACK, PROVIDE PERMANENT CLEAR ADHESIVE LABEL. LABEL SHALL BE 2" LONG BY 3/4"WIDE WITH TYPED LETTERING IN BLACK THAT

DENOTES EXACT FAN COIL UNIT TAG IDENTIFIER AS SCHEDULED (I.E. FCU-XYZ) .

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

HVAC GENERAL NOTES & SCHEDULES

M1.0

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

PLUMBING LEGEND

SYMBOL DESCRIPTION

DOMESTIC COLD WATER (CW)

DOMESTIC HOT WATER (HW)

DOMESTIC HOT WATER RETURN (HWR)

SANITARY SEWER OR WASTE (SS OR W)

SANITARY VENT (V)

CLEANOUT (CO)

DOUBLE CLEANOUT (DCO)

WALL CLEANOUT (WCO)

GAS PRESSURE REGULATOR

BALL VALVE

SHUT-OFF VALVE (SOV)

VENT THRU ROOF

UNDER COUNTER

UNDER FLOOR

UNDER GROUND

UNDER SLAB

ABOVE FINISHED FLOOR

CONDENSATE DRAIN PIPING

CONNECT TO EXISTING

C

VALVE IN BOX

VALVE IN VERTICAL

VTR

U/C

U/F

U/G

U/S

AFF

FIRE MAIN

FIRE DEPARTMENT CONNECTION (FDC)

F

PLUMBING GENERAL NOTES

CONTRACTOR TO PROVIDE A COMPLETE AND WORKABLE PLUMBING SYSTEM IN ACCORDANCE

WITH BUT NOT LIMITED TO THE PLANS AND SPECIFICATIONS. COMPLY WITH LATEST EDITIONS

OF ALL APPLICABLE CODES. OBTAIN ALL PERMITS AND PAY ALL REQUIRED FEES.

CONTRACTOR SHALL COORDINATE LOCATION OF UTILITY MAINS WITH CIVIL SITE PLAN FOR

EXACT ROUTING OF BUILDING SERVICE LINES PRIOR TO BIDDING. UTILITY SERVICE REVISIONS

REQUIRED DURING CONSTRUCTION SHALL BE COMPLETED AT NO EXTRA COST TO OWNER.

V.T.R.'S SHALL BE MIN 10'-0" FROM O/A INTAKES. OFFSET VENT AS REQUIRED. COMBINE VENTS

WHERE POSSIBLE TO MINIMIZE ROOF PENETRATIONS. VERIFY LOCATIONS OF ROOF

PENETRATIONS WITH ARCHITECT PRIOR TO ROUGH-IN.

PROVIDE CHROME PLATED ESCUTCHEONS AT PIPE SLEEVES FOR EXPOSED BARE PIPE.

PROVIDE ACCESS OPENINGS IN GYPSUM BOARD CEILINGS AND INACCESSIBLE WALLS FOR

VALVES AND DAMPERS. PROVIDE HINGED, LOCKABLE ACCESS PANEL COVER IN MILL FINISH;

COORDINATE EXACT LOCATION AND FINAL PAINT FIELD-APPLIED PAINT FINISH PRIOR TO

ROUGH-IN AND INSTALLATION.

INSULATE TAILPIECE, TRAP AND WATER SUPPLIES AT HANDICAPPED FIXTURES. USE TRUEBRO

LAV-GUARD FACTORY FABRICATED INSULATING BOOTS OR APPROVED EQUAL.

PLUMBING FIXTURES SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE AND LOCAL

CONSERVATION STANDARDS.

EQUIPMENT START-UP SHALL BE BY MANUFACTURER'S AUTHORIZED REPRESENTATIVES.

PLUMBING RISER ISOLATION & DRAIN VALVES SHALL BE LOCATED WITHIN EASY REACH OF

CEILING, WHERE CEILINGS OCCUR BELOW OR DROPPED TO WITHIN A MAXIMUM 10'-0" OF

FINISHED FLOOR WHERE NO CEILING OCCURS.

PIPING SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH SMACNA GUIDELINES FOR

SEISMIC RESTRAINT.

INSULATED PIPING AND FITTINGS EXPOSED TO VIEW THROUGHOUT THE FACILITY SHALL BE

COVERED AND FINISHED WITH PVC JACKET EQUAL TO MANVILLE CEEL-CO 550 PIPE JACKETING

SYSTEM USING 30 MIL THICK JACKET AND FITTING COVERS. INSTALL PER MANUFACTURER'S

INSTRUCTIONS WITH SEAM ON TOP OF PIPE SO AS TO BE NOT VISIBLE FROM OCCUPIED

SPACE.

PROVIDE WALL CLEANOUTS AT FIXTURES IN ACCORDANCE WITH APPLICABLE SECTIONS OF

LOUISIANA PLUMBING CODE.

PROVIDE

" SHUTOFF VALVE AHEAD OF EACH TRAP PRIMER. PROVIDE ACCESS OPENING &

DISTRIBUTION DEVICE WHERE NEEDED.

PROVIDE

" SHUTOFF VALVE AHEAD OF EACH WALL FAUCET INSTALLATION. PROVIDE ACCESS

OPENINGS WHERE NEEDED.

COORDINATE EXACT PLUMBING FIXTURE TYPE AND MOUNTING HEIGHT WITH OWNER &

ARCHITECT PRIOR TO ORDER, ROUGH-IN AND INSTALLATION.

COORDINATE EXACT PIPE AND RISER ROUTING WITH STRUCTURAL AND ELECTRICAL TRADES.

NOTIFY ENGINEER OF ANY DISCREPANCIES.

WATER, SPRINKLER AND VENT PIPING SHALL BE RUN AS HIGH AS POSSIBLE (THROUGH JOISTS

AS NECESSARY) TO PROVIDE CLEARANCE FOR OTHER EQUIPMENT AND TRADES. ALL PIPING

TO BE CONCEALED ABOVE CEILING UNLESS OTHERWISE NOTED.

PROVIDE BLOCKING IN WALLS TO SECURE ALL WATER SUPPLY PIPING.

PIPING SHALL NOT BE INSTALLED ABOVE OR WITHIN 3'-0" IN FRONT OF ELECTRICAL SERVICE

PANELS. COORDINATE ROUTING WITH ELECTRICAL CONTRACTOR.

INSTALL WATER CLOSET FLUSH VALVES WITH OPERATING HANDLE ON THE WIDE SIDE OF THE

TOILET STALL, PER ADA REQUIREMENTS.

PROVIDE CONCEALED FIXTURE CARRIERS FOR ALL WALL MOUNTED PLUMBING FIXTURES.

SLOPE FLOORS TO FLOOR DRAINS WHERE INDICATED. REFER TO ARCHITECTURAL AND

FOUNDATION PLANS.

PIPE PENETRATIONS THROUGH FIRE/SMOKE WALLS AND PARTITIONS SHALL BE FIRE-CAULKED.

TEST ENTIRE SYSTEM FOR LEAKS AS REQUIRED BY THE LOCAL AUTHORITY HAVING

JURISDICTION.

STERILIZE WATER SYSTEM WITH CHLORINE SOLUTION AS REQUIRED BY THE LOCAL

AUTHORITY HAVING JURISDICTION.

PROVIDE DOMESTIC WATER SERVICE BACKFLOW PREVENTER AS REQUIRED BY LOCAL

AUTHORITY HAVING JURISDICTION. COORDINATE WITH SITE UTILITIES CONTRACTOR AND CIVIL

SITE UTILITY PLANS.

WHERE VISIBLE TO PUBLIC VIEW, PRIME/PAINT ALL ASSOCIATED EXPOSED PLUMBING SYSTEM

COMPONENTS TO MATCH ADJACENT FINISHES, UNLESS DIRECTED OTHERWISE BY ARCHITECT.

ALL ASSOCIATED FIELD PAINTING UNLESS DIRECTED OTHERWISE SHALL BE BY A PAINTING

CONTRACTOR; COORDINATE IN ADVANCE AS REQUIRED.

FOR INTERIOR, PROVIDE INSULATED FULL SIZE (OR SIZE AS NOTED) COPPER CONDENSATE

DRAIN FROM ALL COOLING COILS AS NOTED. TERMINATE OPEN SITE. FOR EXTERIOR (ROOF),

PROVIDE FULL SIZE (OR SIZE AS NOTED) "PAINTED" SCHEDULE 80 PVC CONDENSATE DRAIN

FROM ALL HVAC UNIT CONDENSATE CONNECTIONS; EXTEND AND TERMINATE AT ROOF DRAIN

OR AS NOTED.

WITH REGARDS TO INSTALLATION, THE EXACT LOCATION OF ALL OTHER BUILDING SYSTEMS,

INCLUDING, BUT NOT LIMITED TO, STRUCTURAL FRAMING, DUCTWORK, CONDUIT, PIPING, ETC., SHALL TAKE PRECEDENCE OVER THE LOCATION AND ROUTING OF AUTOMATIC FIRE

SPRINKLER PIPING SYSTEM; SCHEDULE ACCORDINGLY WITH ALL APPROPRIATE TRADES AND

COORDINATE NECESSARY PROVISIONS WITH ALL BUILDING SYSTEMS TO AVOID ANY

CONFLICTS AND DISCREPANCIES DURING CONSTRUCTION.

FLOOR DRAINFD

R

TRAP PRIMERTP

TRAP GUARD INSERTTG

PLUMBING FIXTURE AND ROUGH-IN SCHEDULE

MARK MANUF MODEL DESCRIPTION ACCESSORIES TRIM OR VALVE DRAIN TRAP SUPPLIES HW CW WASTE VENT

LH INTEGRAL LAVATORY; RE: ARCHITECTURAL KOHLER 15265-4 McGUIRE 155A McGUIRE

McGUIRE

2165LK 1/2 1/2 1 1/2 1 1/4 2

S1 ELKAY EULHAD161655

16"x16"x5.5" DEEP SS SINGLE BOWL

UNDERMOUNT SINK, 18 GA, TYPE 304

(ADA COMPLIANT)

TRUEBRO 102/105-W

PIPE GUARDS

ELKAY LKD208888C,

SINGLE-HOLE, 8"

HIGH GOOSENECK

McGUIRE 151A

McGUIRE

McGUIRE

2165LK 1/2 1/2 1 1/2 1 1/4

SS JUST C-2523 25"x23"x10" DEEP SS MOP SINK, 16 GA, TYPE 304

HOSE & HOSE

HOLDER, STAINLESS

STEEL WALL GUARDS

FIAT 830-AA

FAUCET INTEGRAL CAST IRON

DEEP SEAL - 1/2 1/2 3 2

EWCH ELKAY LZS8WSVRSK

STAINLESS STEEL TOP, SINGLE ELECTRIC

WATER COOLER, PUSH BAR CONTROL,

INTEGRAL FILTERED BOTTLE FILLING

STATION WITH ELECTRONIC SENSOR, 8

GPH OF 50° DRINKING WATER

- - INTEGRAL

GRID

McGUIRE

INTEGRAL

STOPS - 1/2 1 1/2 1 1/4

FD WADE W-MS-SS

TYPE 304 STAINLESS STEEL SQUARE

STAINER WITH SECURED SQUARE HOLE

PATTERN GRATE, VANDAL PROOF

- - - CAST IRON

DEEP SEAL - - 1/2 3 2

FS WADE W-9100-1

STAINLESS STEEL, 12" SQUARE FLOOR

SINK, 6" DEEP ROUND SUMP, SATIN

FINISH NICKEL BRONZE TOP, HINGED

GRATE, BOTTOM OUTLET, VANDAL

PROOF

PERFORATED

STAINLESS STEEL

SEDIMENT BUCKET

- - CAST IRON

DEEP SEAL - - 1/2 AS

NOTED 2

TP PPP, INC. PRIME RITE TRAP PRIMER VALVE

DISTRIBUTION UNIT

AS APPLICABLE FOR

MULTIPLE FLOOR

DRAINS

- - - - - 1/2 - -

TG PROSET

SYSTEMS PROVENT TRAP GUARD - - - - - - - - -

WH

BRADFORD

WHITE

65T-65FB-3N

65 GALLON GAS WATER HEATER, 65 BTUH

INPUT (MINIMUM)

- - - - - 3/4 3/4 - -

HWC GRUNDFOS UP 43-75BF DOMESTIC HOT WATER RECIRCULATING

PUMP, 1/6 HP, BRONZE FLANGED BODY - - - - - 3/4 - - -

IOB OATEY 38689 METAL ICE MAKER WATER SUPPLY BOX - - - - - - 1/2 - -

REFERENCE PLUMBING FIXTURE SPECIFICATION FOR ADDITIONAL ALTERNATE MANUFACTURERS.

*VERIFY EXACT FIXTURE TYPE, FINISH, MOUNTING HEIGHT, ETC. WITH ARCHITECT PRIOR TO ORDER AND INSTALLATION.

**CONTRACTOR SHALL VERIFY ALL POWER REQUIREMENTS WITH ELECTRICAL PLANS PRIOR TO ORDER AND INSTALLATION.

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

PLUMBING GENERAL NOTES & SCHEDULES

M1.1

T

T

TT

T

T

T

T

T

T

T

T T T

T

T

T

T

T

T

G1

G3

D2 8

D1 10

D1 10

TYP 2

D1 10

TYP 2

D1 10

TYP 2

D1 10

D2 8

D2 8

D2 8

D2 8

D1 10

TYP 2

G3 G3 G3

G3

G3

G3

G3

G3

G4

D2 6

D1 8

D1 8

D1 10

TYP 2

D2 6

D1 12

TYP 2

D1 8

D1 8

G1

D1 8

D1 8

SEE SHEET M2.1 FOR

STAIRWELL HVAC

SEE SHEET M2.1 FOR

STAIRWELL HVAC

G3

FCU1-1

D1 12

TYP 2

T

G3

TT

D1 8

TYP 2

FCU1-2

FCU1-3

FCU1-4

FCU-1-5

FCU1-6

FCU1-7

FCU1-8

FCU1-9

FCU1-10

FCU1-11

FCU1-12

FCU1-13

FCU1-16

FCU1-17

FCU1-18

FCU1-19

FCU1-20

FCU1-21

FCU1-23

FCU1-24

FCU1-25

FCU1-26

FCU1-28

FCU1-29FCU1-30

FCU1-32

FCU1-34

FCU1-35 FCU1-36

FCU1-37

FCU1-38

FCU1-39

FCU1-40

FCU1-41

FCU1-42 FCU1-43 FCU1-44

HRCU-1

A B

HRCU-2

A B

T

T

T

T

T

T

TT

T

T

T

T

T

T

T

T

T

D1 8

D1 8

D1 10

10/6

18/8

8/4

14/12

FCU1-33

FCU1-31

FCU1-45

FCU1-14

T

FCU1-46

14/14

14/14

12/10

D1 10

D1 10

D1 10

10/12

10"Ø

10/10

10"Ø

10/12

18/12

10/12

16/1212/12

12"Ø 12"Ø 12"Ø

16/12

10"Ø10/1210"Ø

18"

D2 6

70 6

18"

D2 6

18"

T

D1 10

TYP 2

D1 10

18"

18"

18"

18"

18"

18"

18"

18"

18"

T

T

4"Ø

6"Ø

SEE PLAN THIS

SHEET FOR WORK

IN THIS AREA

G2

G2

G2

14/10

FCU1-22

FCU1-15

TYP

OACU-1

D2 8

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

6"Ø

4"Ø

D2 6

D2 6

D2 6

4"Ø

4"Ø

4"Ø

4"Ø

4"Ø

D2 4

D2 4

4"Ø

4"Ø

C

4"Ø

4"Ø

16/12 16/12

8"Ø

14/10

6"Ø

10/10

10"Ø

6"Ø

6"Ø

6"Ø

6"Ø

6"Ø

16/10

12/10

10"Ø

8"Ø

20"Ø

FCU1-47

T

4"Ø

FCU1-27

18/12

18/12

12/10 14/10 14/10

12/10

12/8

14/10

18/1018/10

14/10

20/12

6/4

12/10

14/10

HRCU-3

A B

D2 4

D2 4

4"Ø

20/18 UP TO OAU-1 ON SECOND

FLOOR (RE: SHEET M2.1)

20/18

16/10

14/1218"Ø

18"Ø FROM OAU-1 ON SECOND

FLOOR (RE: SHEET M2.1)

712 TEXAS ST. SHREVEPORT, LOUISIANA 71101

WORK 318-673-9980 FAX 318-673-9982

CHARLES M. HAZEL, P.E.

29889

NOT TO BE USED FOR

CONSTRUCTION,

BIDDING,

RECORDATION,

CONVEYANCE, SALES,

OR AS THE BASIS FOR

THE ISSUANCE OF A

PERMIT

THESE DRAWINGS DO NOT INCLUDE NECESSARY

COMPONENTS FOR CONSTRUCTION SAFETY.

PRELIMINARY

15-206

ENGINEER:

LICENSE NO.

CONSULTING ENGINEERS

3003 KNIGHT STREET, SUITE 120

SHREVEPORT, LOUISIANA 71105

phone: 318-425-7452 fax: 318-425-4622 www.AFJMc.com

1. BALANCE OUTSIDE AIR DUCT BRANCH TO NOTED

AIRFLOW VALUE. BRANCH DUCT SIZE AS INDICATED.

2. PROVIDE MINIMUM 12" CLEARANCE FOR ALL MECHANICAL

EQUIPMENT LOCATED IN CEILING SPACE UNLESS NOTED

OTHERWISE. 12" CLEARANCE SHALL INCLUDE ALL FOUR

SIDES AND VERTICALLY.

3. IN ALL FULLY INACCESSIBLE CEILING LOCATIONS FOR

EACH INLINE DUCT MANUAL BALANCING DAMPER, PROVIDE

SELF LOCKING, WORM GEAR DRIVEN HANDLE WITH

FLEXIBLE SHAFT, CONNECTOR AND PAINT-GRIP, MILL FINISH

COVER PLATE (PRIME/PAINT TO MATCH ADJACENT FINISH).

COORDINATE WITH EXACT FINAL CEILING PLAN PRIOR TO

ROUGH-IN AND INSTALLATION.

SCALE: 1/8"=1'-0"

SCALE: 1/8"=1'-0"

SEE SHEET M4.0 FOR CONDENSATE DRAIN PIPING.

SEE SHEET M3.0 FOR BRANCH SELECTOR

LOCATIONS AND REFRIGERANT PIPING LAYOUT.

SEQUENCE OF OPERATIONS

OAU-1 IS A 100% OUTSIDE AIR CONSTANT VOLUME UNIT THAT WILL PROVIDE NEUTRAL

AIR TO THE BUILDING AND SUPPLEMENT COOLING WHEN POSSIBLE. THE OUTSIDE

AIR AND THE EXHAUST AIR WILL TRAVEL THROUGH A FIXED ENERGY RECOVERY

SECTION THUS TEMPERING THE OUTSIDE AIR. IN COOLING MODE THE SAT SHALL BE

55°F (ADJUSTABLE). WHEN THE ZONE SENSOR FALLS BELOW 70°F (ADJUSTABLE) THE

UNIT WILL ENERGIZE THE ELECTRIC HEAT TO BRING THE LAT TO 72°F (ADJUSTABLE).

BELOW 50°F (ADJUSTABLE) THE UNIT WILL BE IN HEATING MODE AND USE THE

ELECTRIC HEAT TO DELIVER A LAT OF 72°F (ADJUSTABLE).

FA4608-17-R-0021

Attachment 2

AutoCAD SHX Text P.A.

AutoCAD SHX Text

%%USTORAGE

AutoCAD SHX Text 125C

AutoCAD SHX Text

%%UPUBLIC AFFAIRS

AutoCAD SHX Text

AutoCAD SHX Text P.A.

AutoCAD SHX Text

%%USTOR.

AutoCAD SHX Text 125A

AutoCAD SHX Text

SERVER

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text

AutoCAD SHX Text

SUPPLIES

AutoCAD SHX Text

%%USTOR.

AutoCAD SHX Text

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text 127A

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

%%UEQUIP.

AutoCAD SHX Text

AutoCAD SHX Text

%%UWOMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UMEN

AutoCAD SHX Text

AutoCAD SHX Text

%%UELEV.

AutoCAD SHX Text

AutoCAD SHX Text

%%USTAIR 2

AutoCAD SHX Text

%%UCONFERENCE ROOM 1

AutoCAD SHX Text

AutoCAD SHX Text

%%UBW/CC

AutoCAD SHX Text 103A

AutoCAD SHX Text

%%UCCE/CCS

AutoCAD SHX Text

AutoCAD SHX Text

%%UCV

AutoCAD SHX Text 103B

AutoCAD SHX Text

%%UJAG

AutoCAD SHX Text

AutoCAD SHX Text

CST

AutoCAD SHX Text

%%UOFF. 1

AutoCAD SHX Text 118A

AutoCAD SHX Text

CST

AutoCAD SHX Text

%%UOFF. 2

AutoCAD SHX Text 118B

AutoCAD SHX Text

%%UK.M.C.

AutoCAD SHX Text 121A

AutoCAD SHX Text

%%UK.M.C.

AutoCAD SHX Text 121B

AutoCAD SHX Text

%%UN.C.O.

AutoCAD SHX Text 123B

AutoCAD SHX Text

%%UN.C.O.

AutoCAD SHX Text

AutoCAD SHX Text

RECR.

AutoCAD SHX Text

%%UOFF. 1

AutoCAD SHX Text 113B

AutoCAD SHX Text

RECR.

AutoCAD SHX Text

%%UOFF. 2

AutoCAD SHX Text 113C

AutoCAD SHX Text

RECR.

AutoCAD SHX Text

%%UWAITING

AutoCAD SHX Text

AutoCAD SHX Text

JAG

AutoCAD SHX Text

%%UOFF. 1

AutoCAD SHX Text 107A

AutoCAD SHX Text

JAG

AutoCAD SHX Text

%%UOFF. 2

AutoCAD SHX Text 107B

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100A

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100B

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100C

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100D

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100E

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100G

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100J

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100K

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100L

AutoCAD SHX Text

BREAK

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text

AutoCAD SHX Text

%%UJAN.

AutoCAD SHX Text

AutoCAD SHX Text

%%USTAIR 1

AutoCAD SHX Text

RECR.

AutoCAD SHX Text

%%USTOR.

AutoCAD SHX Text 113A

AutoCAD SHX Text

%%UCST LAB

AutoCAD SHX Text 118C

AutoCAD SHX Text

%%UART. CST

AutoCAD SHX Text

AutoCAD SHX Text

COMM

AutoCAD SHX Text

%%UEXEC OFFICER

AutoCAD SHX Text 122A

AutoCAD SHX Text

%%UNETWORK OPS.

AutoCAD SHX Text

AutoCAD SHX Text

%%UNETWORK OPS.

AutoCAD SHX Text

AutoCAD SHX Text

SIPR

AutoCAD SHX Text

%%USERVER

AutoCAD SHX Text 114A

AutoCAD SHX Text

%%UCST STORAGE

AutoCAD SHX Text

AutoCAD SHX Text F.S.S.

AutoCAD SHX Text

PERSCO

AutoCAD SHX Text

%%UOFFICE

AutoCAD SHX Text

AutoCAD SHX Text

YELLOW RIBBON

AutoCAD SHX Text

AutoCAD SHX Text

PA PORTRAIT

AutoCAD SHX Text

%%USTUDIO

AutoCAD SHX Text

AutoCAD SHX Text

%%UMAIL

AutoCAD SHX Text

AutoCAD SHX Text

COMM.

AutoCAD SHX Text

CHIEF

AutoCAD SHX Text

%%UEXEC.

AutoCAD SHX Text

AutoCAD SHX Text

WING STAFF

AutoCAD SHX Text

%%USUPPLY

AutoCAD SHX Text 125B

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100H

AutoCAD SHX Text

COMM

AutoCAD SHX Text

%%USUPERINTENDENT

AutoCAD SHX Text 122B

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100K

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100K

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100G

AutoCAD SHX Text

%%UCORR.

AutoCAD SHX Text 100H

AutoCAD SHX Text

%%UFOYER

AutoCAD SHX Text 100F

AutoCAD SHX Text

COMMAND

AutoCAD SHX Text

%%UCHIEF

AutoCAD SHX Text 105A

AutoCAD SHX Text

%%UN.C.O.

AutoCAD SHX Text 123A

AutoCAD SHX Text

%%UK.M.C.

AutoCAD SHX Text

AutoCAD SHX Text

%%UMINI CONF. ROOM

AutoCAD SHX Text

AutoCAD SHX Text

FACILITY

AutoCAD SHX Text

%%UMGR.

AutoCAD SHX Text 105B

AutoCAD SHX Text A.V.

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text 102A

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

HISTORIANS

AutoCAD SHX Text

AutoCAD SHX Text

EXIST BUSHES TO REMAIN

AutoCAD SHX Text

EXIST SIDEWALK

AutoCAD SHX Text

SUPPLIES

AutoCAD SHX Text

%%USTOR.

AutoCAD SHX Text

AutoCAD SHX Text

ELEC.

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text 127A

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

%%UROOM

AutoCAD SHX Text

AutoCAD SHX Text

ELEV.

AutoCAD SHX Text

%%UEQUIP.

AutoCAD SHX Text

AutoCAD SHX Text 113C

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Facility Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text

PROJECT TITLE

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

SHEET TITLE

AutoCAD SHX Text

OF

AutoCAD SHX Text

REVISION

AutoCAD SHX Text

BY/DATE

AutoCAD SHX Text Designer

AutoCAD SHX Text Drafter

AutoCAD SHX Text Project Manager

AutoCAD SHX Text Date

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text Engineer

AutoCAD SHX Text Pavements

AutoCAD SHX Text Engineer

AutoCAD SHX Text Corrosion

AutoCAD SHX Text Protective

AutoCAD SHX Text Engineer

AutoCAD SHX Text Coating Engr.

AutoCAD SHX Text Fire Chief

AutoCAD SHX Text Operations

AutoCAD SHX Text Chief of

AutoCAD SHX Text Construction

AutoCAD SHX Text Roofing

AutoCAD SHX Text Management

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text Computers

AutoCAD SHX Text Engineer

AutoCAD SHX Text Systems

AutoCAD SHX Text Security

AutoCAD SHX Text Police

AutoCAD SHX Text Security

AutoCAD SHX Text Bioenvironmental

AutoCAD SHX Text Airfield

AutoCAD SHX Text Safety

AutoCAD SHX Text Ground

AutoCAD SHX Text Manager

AutoCAD SHX Text Communication

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SIGNATURE

AutoCAD SHX Text Chief of

AutoCAD SHX Text Engineering

AutoCAD SHX Text Design

AutoCAD SHX Text Chief of

AutoCAD SHX Text Contracting

AutoCAD SHX Text User

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text Engineer

AutoCAD SHX Text Civil

AutoCAD SHX Text Air Force Base

AutoCAD SHX Text Barksdale

AutoCAD SHX Text Louisiana

AutoCAD SHX Text

DESIGN FIRM

AutoCAD SHX Text

OCTOBER 2015

AutoCAD SHX Text B6803

AutoCAD SHX Text 14M

AutoCAD SHX Text

CMH

AutoCAD SHX Text

CMH

AutoCAD SHX Text

KDR

AutoCAD SHX Text

27 OCT 2015

AutoCAD SHX Text

BARKSDALE AIR FORCE

AutoCAD SHX Text

BASE, LOUISIANA 71110

AutoCAD SHX Text

REPAIR WING HEADQUARTERS

AutoCAD SHX Text

AWUB 08-9014

AutoCAD SHX Text

24 FEB 2016

AutoCAD SHX Text

25 APR 2016

AutoCAD SHX Text

TITLE 1-A

AutoCAD SHX Text

TITLE 1-B 35%%%

AutoCAD SHX Text

TITLE 1-B 65%%%

AutoCAD SHX Text

19 DEC 2016

AutoCAD SHX Text

TITLE 1-B 95%%%

AutoCAD SHX Text

14 MAR 2017

AutoCAD SHX Text

TITLE 1-B 100%%%

AutoCAD SHX Text

%%UMECHANICAL NOTES%%U:

AutoCAD SHX Text

FIRST FLOOR MECHANICAL PLAN

AutoCAD SHX Text

FIRST FLOOR MECHANICAL PLAN

AutoCAD SHX Text M2.0

FIRST FLOOR MECHANICAL ROOM

T

T

T

T

T

T

T

T

T

T

TT

T T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

D1 10

TYP 2

D1 10

TYP 2

D1 10

D1 10

D1 10

TYP 3

D1 8

D1 10

TYP 8

D1 8

D1 8

D1 8

G3

G3 G3

G4

G3

G3

G3

G1

G4 G4

G3 G3

G5

G3

D2 6

D2 6

D2 8

D1 8

T

G3

T

D1 8

D1 8

D1 8

D1 8

D1 8

D1 8

FCU2-1

FCU2-2

FCU2-39

FCU2-5

FCU2-7

FCU2-11

FCU2-12

FCU2-13

FCU2-14

FCU2-15

FCU2-16

FCU2-17

FCU2-18

FCU2-19

FCU2-20

FCU2-22

FCU2-24

FCU2-25

FCU2-28

FCU2-31

FCU2-32

FCU2-34

FCU2-35

FCU2-36

FCU2-37

FCU…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .