Attachment_2_-_Drawings.pdf
PDF 9 MB Posted
- Attached to
- Renovate MRC Office Space - Building 546 Federal contract opportunity
- Solicitation number
- FA4528-R-17-0019
About this file
Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment_6_-_Questions_and_Answers.docx | DOCX document | |
| FA4528-17-R-0019_Amendment_0001.pdf | ||
| Attachment_3_-_Wage_Determination.pdf | ||
| Attachment_4_-_Past_Performance_Information_Form.docx | DOCX document | |
| FA4528-17-R-0019_MRC_Office_Space.pdf | ||
| Attachment_5_-_Financial_Responsibility.docx | DOCX document | |
| Attachment_1-_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C O
V E
R
S
H E
E T
G-001
K H
A
K H
A
K H
A
B
M
R C
G
D
W G
K H
A
NORTH
VICINITY MAP
SITE
PROJECT
NO SCALE SCALE: 1"=500'
MAFB PROJECT NO: QJVF 15-0052
RENOVATE MRC OFFICE SPACE
MINOT AFB, NORTH DAKOTA
LOCATION PLAN
BASE GATE
HAUL ROUTE
HI
GH
W
AY
BOMBER BLVD.
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
T
S
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
N
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
A
I R
F
R
E
B
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
M
F
I C
E
S
P A
C E
B U
I L D
I N
G
U B
M I T
T A
L
A
P
B
M I T
T A
L
Y
B
M I T
T A
L
J U
N
S
U B
M I T
T A
L
NORTH
MINUTE
MAN
DR.
LOCATION
PROJECT
8 JUNE 2016
GENERAL
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS, LEGENDS AND GENERAL NOTES
G-003 ABBREVIATIONS
G-004 FIRE PROTECTION PLAN AND CODE ANALYSIS
ARCHITECTURAL
AD101 REMOVAL PLAN
A-101 FLOOR PLAN
A-102 REFLECTED CEILING PLAN, DOOR AND FRAME
SCHEDULE, ELEVATIONS AND DETAILS
A-201 INTERIOR ELEVATIONS
A-202 CASEWORK SECTIONS
A-601 ROOM FINISH SCHEDULE AND WALL TYPES
FIRE PROTECTION
FD101 FIRE ALARM REMOVAL FLOOR PLAN
FA101 FIRE ALARM FLOOR PLAN
MECHANICAL
MG101 MECHANICAL SYMBOLS LEGEND
MG102 MECHANICAL GENERAL NOTES
MD101 MECHANICAL REMOVAL FLOOR PLAN
MD201 MECHANICAL PIPING DEMOLITION FLOOR PLAN
MH101 MECHANICAL FLOOR PLAN
MP101 MECHANICAL PIPING FLOOR PLAN
M-301 MECHANICAL SECTIONS
M-401 MECHANICAL CONTROLS
M-501 MECHANICAL DETAILS
M-502 MECHANICAL DETAILS
M-601 MECHANICAL FIXTURE AND EQUIPMENT SCHEDULES
ELECTRICAL
EG101 ELECTRICAL SYMBOLS AND GENERAL NOTES
ED101 ELECTRICAL REMOVAL FLOOR PLAN
EL101 LIGHTING FLOOR PLAN
EP101 POWER FLOOR PLAN
EP102 GROUNDING SYSTEM FLOOR PLAN
EY101 SPECIAL SYSTEMS FLOOR PLAN
EY102 SPECIAL SYSTEMS FLOOR PLAN
COMMUNICATIONS CABLING
E-501 ELECTRICAL RISER DIAGRAM AND DETAILS
E-601 ELECTRICAL DETAILS
E-602 LIGHTING CONTROLS DETAILS
E-701 ELECTRICAL SCHEDULES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
EARTH
CONCRETE
GRAVEL
MASONRY VENEER
METAL
PLYWOOD
WOOD (FINISH)
WOOD (ROUGH)
GLASS (ELEVATION)
BLANKET INSULATION
RIGID INSULATION
GYPSUM WALLBOARD OR CEMENT
CONCRETE MASONRY UNITS (PLAN)
CONCRETE MASONRY UNITS (SECTION)
GLASS (LARGE SCALE SECTION)
ROOM NAME / NUMBER
DOOR NUMBER
WINDOW NUMBER
WALL TYPE
SIGN TYPE
KEY NOTE
FIBERBOARD SHEATHING
BOARD PANEL/TRIM AS INDICATED
1. ALL WORK SHALL COMPLY WITH APPLICABLE CODES, REGULATIONS,
AND ORDINANCES.
2. THE CONTRACTOR SHALL PERFORM ALL TESTING AND INSPECTIONS
AS SPECIFIED, OR AS NECESSARY TO DEMONSTRATE A COMPLETE
AND SATISFACTORY INSTALLATION.
3. THE CONTRACTOR SHALL PROTECT EXISTING BUILDING AND SITE
MATERIALS SCHEDULED TO REMAIN, AND SHALL BE RESPONSIBLE
FOR DAMAGE TO THE SAME RESULTING FROM WORK UNDER THIS
CONTRACT. THE CONTRACTOR SHALL RESTORE DAMAGED
EXISTING BUILDING AND SITE MATERIALS TO THEIR ORIGINAL
CONDITION.
4. CONTRACTOR SHALL EXERCISE CAUTION TO AVOID ANY DAMAGE
WHEN PERFORMING EARTHWORK, PAVING, OR ANY CONSTRUCTION
IN THE VICINITY OF EXISTING UTILITIES, BUILDINGS, AND
LANDSCAPING.
5. CONTRACTOR SHALL INSPECT SITE AND FIELD VERIFY ALL
DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING
CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING
OFFICER IMMEDIATELY OF ANY DISCREPANCIES.
6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, AND SHALL BE
RESPONSIBLE FOR PROPER FIT OF ALL ITEMS. CONTRACTOR SHALL
COORDINATE ALL WORK AND SHOP DRAWINGS WITH OTHER
TRADES.
7. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL
WORK. CONTRACTOR SHALL ANTICIPATE AREAS WHERE THE
INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WILL BE
RESTRICTED, CONGESTED, OR DIFFICULT TO INSTALL, AND SHALL
COORDINATE INSTALLATION BETWEEN THE TRADES.
8. CONTRACTOR SHALL COORDINATE LOCATIONS FOR ALL
MECHANICAL AND ELECTRICAL ITEMS WITH THE GENERAL
CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING
OFFICER OF ANY DISCREPANCIES PRIOR TO INSTALLATION AND/OR
FABRICATION.
9. ALL BUILDING DIMENSIONS ARE TO FACE OF GWB, FACE OF
MASONRY, OR OUTSIDE FACE OF HOLLOW METAL DOOR FRAME.
10. ALL ANGLES ON PLANS ARE 45- OR 90-DEGREES, UNLESS NOTED
OTHERWISE.
11. ALL ELEVATIONS INDICATED ON THE DRAWINGS ARE BASED ON A
LOWER FLOOR DATUM OF +100'-0”. WHERE ITEMS ARE LABELED
A.F.F. (ABOVE FINISHED FLOOR), CONTRACTOR SHALL SET THE ITEM
AS MEASURED FROM THE LOCAL FLOOR ELEVATION. COORDINATE
ANY DISCREPANCIES REGARDING THIS SITUATION TO ASSURE THAT
ALL BUILDING COMPONENTS ARE PROPERLY SET TO FUNCTION AS
INTENDED. CONTRACTOR SHALL ERECT ALL PARTITIONS IN A
VERTICAL PLANE, NOT NECESSARILY PERPENDICULAR TO THE
FLOOR.
12. ALL MATERIALS AND EQUIPMENT OF THE SAME TYPE SHALL BE
SUPPLIED BY THE SAME MANUFACTURER, AND SHALL BE NEW, OF
THE BEST QUALITY AND DESIGN, AND FREE FROM DEFECTS.
13. ALL ITEMS ARE NEW UNLESS SPECIFICALLY IDENTIFIED AS
EXISTING.
14. INSTALL WOOD BLOCKING OR 16-GA. SHEET METAL BACKING WITHIN
PARTITIONS AS REQUIRED FOR INSTALLATION OF WALL-MOUNTED
CABINETS, TOILET ACCESSORIES, WALL STOPS, AND
MISCELLANEOUS ITEMS.
15. ALL GYPSUM BOARD IS 5/8” THICK TYPE "X", UNLESS NOTED
OTHERWISE.
16. ALL METAL STUDS ARE 3-5/8” WIDE, UNLESS NOTED OTHERWISE.
17. IN SOME INSTANCES, THERMAL AND SOUND INSULATION HAS BEEN
OMITTED FROM DETAILS FOR CLARITY. SEE SPECIFICATIONS, WALL
TYPES, AND DETAILS FOR LOCATIONS REQUIRING INSULATION.
GENERAL NOTES
INDEX LEGEND
ARCHITECTURAL LEGEND
LEGEND NOTES
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO
THE CONDITIONS ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS SET
OF DRAWINGS TO INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON
THIS SHEET.
NORTH ARROWS
SECTION IDENTIFICATION
SHEET NUMBERS OMITTED IF SECTION IS CUT AND DETAILED ON SAME
DRAWING.
ELEVATION IDENTIFICATION
ARCHITECTURAL SYMBOLS
ROOM
NAME
N
TRUE
NORTH
N
PLAN
NORTH
SHEET NUMBER OF DRAWING WHERE SECTION IS
SHOWN
SECTION NUMBER
A-501
DISCIPLINE DESIGNATOR (ARCH, STRUCT, MECH, ELEC, ETC.)
SHEET REFERENCE NUMBER
1. SHEET NUMBERS:
A -1 0 1
SHEET TYPE DESIGNATOR; FOR EXAMPLE 1 WOULD BE
FLOOR PLANS, 2 ELEVATIONS, 3 SECTIONS, ETC.
(SEE A/E/C CADD STANDARDS)
DIRECTION OF SIGHT OF ELEVATION ON
PLAN
SHEET NUMBER OF DRAWING WHERE
ELEVATION IS SHOWN
DIRECTION OF SIGHT OF ELEVATION
ON PLAN
SHEET NUMBER OF DRAWING WHERE
ELEVATION IS SHOWN
A-401
B
A
D
C
A A-401
ASBESTOS AWARENESS
A SURVEY FOR ASBESTOS CONTAINING MATERIALS (ACM) HAS BEEN PERFORMED AND
ACM WAS IDENTIFIED IN THE BUILDING. THE SURVEY IS ATTACHED TO THE
SPECIFICATIONS. ALL ASBESTOS CONTAINING MATERIALS (ACM) IDENTIFIED IN THE
SURVEY SHALL BE REMOVED AND DISPOSED IN ACCORDANCE WITH ALL REGULATORY
REQUIREMENTS.
IF DURING REMOVAL WORK THE CONTRACTOR DISCOVERS ANY ADDITIONAL MATERIAL
NOT IDENTIFIED IN THE REPORT WHICH HE/SHE SUSPECTS MAY CONTAIN ASBESTOS,
HE/SHE SHALL IMMEDIATELY NOTIFY THE GOVERNMENT AND CEASE WORK IN CLOSE
PROXIMITY TO THE SUSPECTED ASBESTOS-CONTAINING MATERIAL. THE COVERMENT WILL
THEN ARRANGE FOR THE TESTING AND REMOVAL OF THE ADDITIONAL
ASBESTOS-CONTAINING MATERIALS.
LEAD BASED PAINT AWARENESS
A SURVEY FOR LEAD BASED PAINT (LBP) HAS BEEN PERFORMED AND LBP WAS NOT
IDENTIFIED IN THE BUILDING. THE SURVEY IS ATTACHED TO THE SPECIFICATIONS. IF A
MATERIAL IS ENCOUNTERED WHICH IS SUSPECTED OF CONTAINING PAINT WITH LEAD,
WORK MUST BE STOPPED TO ASSESS THE SITUATION. CONSTRUCTION ACTIVITIES
IMPACTING PAINT WITH LEAD (PWL) OR MATERIALS CONTAINING LEAD BASED PAINT WHICH
ARE DISTURBED DURING THE WORK SHALL BE HANDLED IN ACCORDANCE WITH ALL
REGULATORY REQUIREMENTS.
PCB AWARENESS
IT IS NOT ANTICIPATED THAT MATERIAL CONTAINING POLYCHLORINATED BIPHENYLS
(PCBs) WILL BE ENCOUNTERED DURING THE COURSE OF THIS PROJECT. IF A MATERIAL IS ENCOUNTERED WHICH IS SUSPECTED OF CONTAINING PCBs, WORK MUST BE STOPPED TO
ASSESS THE SITUATION. ANY WASTE IDENTIFIED AS RESOURCE CONSERVATION AND
RECOVERY ACT (RCRA) HAZARDOUS WASTE MUST BE MARKED, LABELED, STORED, AND
TRANSPORTED IN ACCORDANCE WITH RCRA, DOT, AND STATE REGULATIONS.
INDEX OF DRAWINGS
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T A
L
I N
D E
X
O
F
D
R A
W I N
G S
L E
G E
D
D
G E
N E
R A
L
N
O T
E S
G-002
K H
A
K H
A
K H
A
B
M
R C
G
D
W G
K H
B R
E V
I A
T I O
G-003
K H
A
K H
A
K H
A
B
M
R C
G
D
W G
K H
A
ABBREVIATIONS
A
AB ANCHOR BOLT
AC ALTERNATING CURRENT
A/C AIR CONDITIONING
ACI AMERICAN CONCRETE INSTITUTE
ACSR ALUMINUM CONDUCTOR STEEL
REINFORCED
ACST ACOUSTIC
AD ACCESS DOOR
A.D. AREA DRAIN ADMIN.
ADMINISTRATION/ADMINISTRATIVE
AECS AUTOMATED ENTRY CONTROL SYSTEM
A.F.F. ABOVE FINISH FLOOR
AFFF AQUEOUS FILM FORMING FOAM
AGG AGGREGATE
AHU AIR HANDLING UNIT
A.I. AREA INLET
AIC AMPS INTERRUPTING CAPACITY (SYM
RMS)
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
AL ALUMINUM
A.L. ACTIVE LEAF
ALT ALTERNATE
AMP AMPERE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
AP ACCESS PANEL
APPD APPROVED
APROX. APPROXIMATE
ARCH ARCHITECTURAL OR ARCHITECT
A.R.I. AMERICAN REFRIGERATION INSTITUTE
ASB ASBESTOS
ASPH ASPHALT
ASSIST. ASSISTANT
ATC ACOUSTICAL TILE CEILING
AUTO AUTOMATIC
AVG AVERAGE
AWC ACOUSTICAL WALL COVERING
AWG AMERICAN WIRE GAUGE
∠ ANGLE
B
BATT INSUL BATT INSULATION
BB BULLETIN BOARD
BC BOOKCASE
BD BOARD
BDY BOUNDARY
BEJ BRICK EXPANSION JOINT
BIT BITUMINOUS
BL BUILDING LINE
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
B.M. BENCH MARK
B.O. BOTTOM OF
BOT BOTTOM
BR BULLET RESISTANT
BRCG BRACING
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRKT BRACKET
BT BENT
BTU BRITISH THERMAL UNIT
BTUH BTU PER HOUR
BUR BUILT-UP ROOFING
C C or CND CONDUIT (FOR RACEWAY- ELECTRICAL
SHEETS)
CAP CAPACITY
CATV CABLE TELEVISION
CC CENTER TO CENTER
CB CATCH BASIN (OR CIRCUIT BREAKER)
CE COVER ELEVATION
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CFT CERAMIC FLOOR TILE
C.F.C.I. CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
C.F.G.I. CONTRACTOR FURNISHED
GOVERNMENT INSTALLED
C.G. CORNER GUARD
CHIM CHIMNEY
C.I. CURB INLET
CI CAST IRON
CIR CIRCULAR
CJ CONTROL JOINT
CKD CHECKED
CKT CIRCUIT
CKTBKR or CB CIRCUIT BREAKER
CL CENTER LINE
CLG CEILING
CLK CLERK
CLKG CAULKING
CLO CLOSET
CLOS CLOSED
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNITS
C (CONT.)
CNTR CONTER
CO CLEANOUT
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION
COMB COMBUSTION
COMP COMPRESSIBLE
COMM COMMUNICATIONS
CONC. CONCRETE
CONF. CONFERENCE
CONN CONNECTION
CONSTR CONSTRUCTION
CONSTR JT. CONSTRUCTION JOINT
CONT CONTINUOUS
COR CORNER
CORR CORRIDOR
COV COVERED
CPL CEMENT PLASTER
CPT CARPET
C.P.S. ~ CYCLES PER SECOND (HERTZ)
CRES CORROSIVE RESISTANT STEEL
CRG CARRIAGE
CRSE COURSE
CS COUNTER SINK
CST CAST STONE TILE
CSMT CASEMENT
CT CERAMIC TILE or CURRENT
TRANSFORMER
CTG CLEAR TEMPERED GLASS
CTIG CLEAR TEMPERED INSULATING GLASS
CTL CARPET TILE
CTR CENTER
CU CONDENSING UNIT
CUH CABINET UNIT HEATER
CU YD CUBIC YARDS
CV CEILING VENT
CW COLD WATER
CWT CERAMIC WALL TILE
CYL CYLINDER
D d PENNY (as in nail - 10d)
D DATUM
DA DOUBLE ACTING
DB DRY BULB
DBL DOUBLE
DC DIRECT CURRENT
D.C.J. DOWELED CONTROL JOINT
DCJT DUMMY CONTOL JOINT
DCL DOOR CLOSER
DEG DEGREE
DEPR DEPRESSION
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DH DUCT HEATER
DIA or ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIR DIRECTOR
DISSEM DISSEMANATION
DISC DISCONNECT
DIST DISTRIBUTION
D & M DRESSED & MATCHED
DN DOWN
DP DAMPPROOFING
DR DOOR
DRN DRAIN
DS DOWN SPOUT
DWG DRAWING
DWLS DOWELS
DX DIRECT EXPANSION
E
E EAST
EA. EACH
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EES EMERGENCY EYEWASH & SHOWER
EIFS EXTERIOR INSULATION & FINISH
SYSTEM
EJ EXPANSION JOINT
EL or ELEV. ELEVATION - GRADE OR BUILDING ELEC. ELECTTRIC or ELECTRICAL
ELEV ELEVATOR
EMD ESTIMATED MAXIMUM DEMAND
ENCL ENCLOSURE
ENT ENTRANCE
E.P. EXPLOSION PROOF
EQ. EQUAL
EQUIP. EQUIPMENT
ES EACH SIDE
EST ESTIMATE
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER TEMPERATURE
EXC EXCAVATE
EXD EXIT DEVICE
EXH EXHAUST
E (CONT.)
EXIST. EXISTING
EXP EXPOSED
EXPL EXPLOSION
EXPN EXPANSION
EXT EXTERIOR
F
F FAHRENHEIT
FA FRESH AIR
FC FOOT CANDLE
FCG FACING
FCJ FLOOR CONSTRUCTION JOINT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
F.D. FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
F.E.S FLARED END SECTION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIG. FIGURE
FIN. FINISH
FIX. FIXTURE
FL or FLR FLOOR FLASH FLASHING
FLEX FLEXIBLE
FLG FLOORING
FLUOR FLUORESCENT
FOS FACE OF STUD
F.O. FIBER OPTIC
FP FIRE PROTECTION
FPM FEET PER MINUTE
FPRF FIRE PROOF
FR FRAME
FRG FURRING
F.S. FULL SIZE
FSF FABIC SILT FENCE
FT. FEET
FTG. FOOTING
FW FIRE WATER
FWC FABRIC WALL COVERING
G
G GAS
G GUTTER
GA GAGE or GAUGE
GAL GALLON
GALV GALVANIZED
G.C.O. GROUND CLEANOUT
GEN GENERAL
G.F.C.I. GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
G.F.G.I. GOVERNMENT FUNISHED
GOVERNMENT INSTALLED
GFE GOVERNMENT FURNISHED EQUIPMENT
G.F.I. or GFI GROUND FAULT INTERRRUPTOR
GFRP GLASS FIBER REINFORCED PLASTER
GI GALVANIZED IRON
GL GLASS
GND or GRND GROUND
GOVT. GOVERNMENT
GPM GALLONS PER MINUTE
GR GRADE
GRS GALVANIZED RIGID STEEL CONDUIT
GRTG GRATING
GSU GRAZED STRUCTURAL UNITS
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H
HB HOSE BIBB
HBD HARDBOARD
HC HANDICAPPED
HCD HALON CONTAINMENT DAMPER
HD HEAD
HDR HEADER
HDRL HANDRAIL
HDW HARDWARE
HM HOLLOW METAL
HP HORSE POWER
HPL HIGH PRESSURE LAMINATE FLOORING
HIP HIGH PRESSURE
H.PT. HIGH POINT
HR HOUR
H.S. HIGH STRENGTH
HSGYP HIGH-STRENGTH GYPSUM PLASTER
HT HEIGHT
HTG HEATING
HTR HEATER
H.W. HEADWALL
HW HOT WATER
HWH HOT WATER HEATER
HYD HYDRAULIC
HZ HERTZ
I I or EF IRON
IC INTERCOM
I.D. INSIDE DIAMETER
IDS INTRUSION DETECTION SYSTEM
I.E. INVERT ELEVATION
IES ILLUMINATING ENGINEERING SOCIETY
IN INCH
INSUL. INSULATION
INT. INTERIOR
INV. INVERT or INVERTER
I.P. IRON PIPE
J JB or J-BOX JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
K
K KEY
kcmil or KCM KILO CIRCULAR MIL
KCP KEENE'S CEMENT PLASTER
KIP KILOPOUND (1000 LBS)
KIT KITCHEN
KL KEY LOCK
KP KICK PLATE
kV KILOVOLTS kVA KILOVOLT AMPERES kvar KILOVOLT AMPERES REACTIVE kW KILOWATT
L
L LUMEN
LAB LABORATORY
LAT LEAVING AIR TEMPERATURE
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUNDS
LD LOAD
LDG LOADING
LG LENGTH
LIN LINEAR
LIS LAWN IRRIGATION SYSTEM
LNTL LINTEL LONG LONGITUDINAL
LP LOW POINT
LPS LIGHT PROOF SHADE
LR LIVING ROOM
L.R. LONG RADIUS
LT LIGHT
LTG LIGHTING
LT. WT. LIGHT WEIGHT
LWT LEAVING WATER TEMPERATURE
M
M THOUSAND
MACH MACHINE
MAINT. MAINTENANCE
MAS MASONRY
MAT or MATL MATERIAL
MAX MAXIMUM
M & B MATCHED & BEADED
MC MEDICINE CABINET
MCJ MASONRY CONTROL JOINT
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MER MECHANICAL EQUIPMENT ROOM
MET. METAL
MFG MANUFACTURING
MFR MANUFACTURER
MLDG MOULDING
MO MASONRY OPENING
MONO MONOLITHIC
MOT MOTOR
MS MOTOR STARTER
MSTC MASTIC
MT METAL THRESHOLD
MTD MOUNTED
N
N NORTH
N.C. NORMALLY CLOSED
NCO NON COMMISSIONED OFFICER
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NU or NO. NUMBER
N.O. NORMALLY OPEN
N.R. NOT REQUIRED
O
O.A. OUTSIDE AIR
OBGL OBSCURE GLASS
OBSC OBSCURE
OB WG OBSCURE WIRE GLASS
OC ON CENTER
OCEW ON CENTER EACH WAY
OD OUTSIDE DIAMETER
OFF. OFFICE
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPS OPERATIONS
O.R. OBSERVATION RISER
OS & Y OUTSIDE SCREW & YORK
P
P PAINT
PA PUBLIC ADDRESS
PART PARTICLE
PBS PUSH BUTTON STATION
P.C.C. PORTLAND CEMENT CONCRETE
P.C. PIONT OF CURVATURE
PC PIECE
PERF PERFORATED
P.E. POLYETHYLENE
PH or ø PHASE
PHAR PHARMACY
P.I. POINT OF INTERSECTION
P.I.V. POST INDICATIING VALVE
PL PLATE
PLAS PLASTER
PL PLASTIC LAMINATE
PLATF PLATFORM
PLBG PLUMBING
PLG PILING
PLY. WD. PLYWOOD
PNL PANEL
POL POLISH PORC PORCELAIN
PP PAINTED PANEL
P.P.M. PARTS PER MILLION
PR PAIR
PREFAB PREFABRICATED
PREFIN REFINISHED
PROC PROCESSING
PROJ PROJECT
PRV PRESSURE REGULATING VALVE
P.S. PRESSED STEEL
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
P.T. POINT OF TANGENCY
PT POINT or POTENTIAL (VOLTAGE)
TRANSFORMER
PTD PAINTED
PTN PARTITON
PVC POLYVINYL-CHLORIDE
PVMT PAVEMENT
PW PASS WINDOW
Q
QT QUART
Q.T. QUARRY TILE
QTRS QUARTERS
1/4 RD QUARTER ROUND
R R or RSR RISER
R.A. RETURN AIR
RAD or R RADIUS
RAG RETURN AIR GRILLE
RAR RETURN AIR REGISTER
RB RESILIENT BASE
RC REMOTE CONTROL
R.C.P. REINFORCED CONCRETE PIPE
RCVR RECEIVER
RD ROUND
R.D. ROOF DRAIN
RDGE RIDGE
RECP RECEPTACLE
RECR RECREATION
RECT. RECTIFIER
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCEMENT
REM REMOVABLE
REPRO REPRODUCTION
REQD REQUIRED
RESIL. RESILIENT
REV REVISIONS
RFG ROOFING
RFS RAISED FLOOR SYSTEM
RGE RANGE
RGH ROUGH
RH RELATIVE HUMIDITY
RM ROOM
RPM REVOLUTIONS PER MINUTE
RPRT RAISED PATTERN RUBBER TILE
RT RUBBER TILE
RUB RUBBER
S
S SOUTH
S.A. SUPPLY AIR
SB SPLASH BLOCK
S.B. SECURITY BARS
SC SPECIAL COATING
SCH SCHEDULE
SCIF SENSITIVE COMPARTMENTED
INFORMATION FACILITY
SCR SCREW
SCT STRUCTURAL CLAY TILE
SCUT SCUTTLE
S.D. SUBDRAIN
SDI STEEL DECK INSTITUTE
SJI STEEL JOIST INSTITUTE
SECT SECTION
SECY SECRETARY
SEQ SEQUENCE
S.F. SQUARE FOOTAGE
SFU STRUCTURAL FACING UNIT
SHLD. SHOULDER
SHT. SHEET
SHTG SHEATHING
SIM SIMILAR
SK SINK
SOV SHUT OFF VALVE
SP STATIC PRESSURE
SPEC SPECIFICATIONS
SPF SOUNDPROOF
SPH SPACE HEATER
SPKR SPEAKER
SPL SPECIAL
SQ SQUARE
SQUAD SQUADRON
SS SOLID SURFACE
SSMR STANDING SEAM METAL ROOFING
S. STL. STAINLESS STEEL
ST STAIN
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STGR STRINGER
STL STEEL
STN STONE
STOR STORAGE
STRUCT STRUCTURAL
STWY STAIRWAY
SUB FL SUB FLOOR
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWBD SWITCHBOARD
SYM SYMMETRICAL
T
T TREAD
TAN. TANGENT
TBD TACK BOARD
TC TOP OF CURB
TCA TILE COUNCIL OF AMERICA
T.E. TOP ELEVATION
TECH TECHNICAL
TEL TELEPHONE
TEMP TEMPERATURE
TER TERRAZZO
TERM TERMINAL
TGL TOGGLE
TH THRESHOLD
THK THICK
T.O. TOP OF
TOS TOP OF STEEL
TOIL TOILET
TOPO TOPOGRAPHY
TRANS TRANSVERSE
T'STAT THERMOSTAT
TT TERRAZZO TILE
TV TELEVISION
TYP TYPICAL
U
UC UNIT COOLER
UG UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UPS UNINTERRUPTIBLE POWER SYSTEM
UR URINAL
UT UTILITY
UV UNIT VENTILATOR
V
V VOLT
VB VINYL BASE
VCP VITRIFIED CLAY PIPE
V.C.T. VINYL COMPOSITION TILE
VD VAULT DOOR
VENT VENTILATION
VENT VENTILATOR
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
V.P.C. VERTICAL POINT OF CURVATURE
V.P.I. VERTICAL POINT OF INTERSECTION
V.P.T. VERTICAL POINT OF TANGENCY
V.R. VAPOR RETARDER
VS VENT STACK
VT VINYL-TILE OR VOLTAGE
TRANSFORMER
VTR VENT THRU ROOF
VWC VINYL-WALL COVERING
W
W WEST
W WIRE
W/ WITH
WB WET BULB
WC WATER CLOSET
WC WALLCOVERING
WCO WALL CLEANOUT
WD WOOD
W.D. WASTE DRAIN
WD. BLK. WOOD BLOCKING
WD. DR. WOOD DOOR
WDW WINDOW
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HYDRANT
WHM WATTHOUR METER
WHT WHITE
W.I. WROUGHT IRON
WKSH WORK SHOP
WNSCT WAINSCOT
W/O WITHOUT
WP WALL PANEL
WP WEATHER PROOF
WPF WATER PROOF
WPFG WATER PROOFING
WRB WARDROBE
WS WASTE STACK WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WOVEN WIRE MESH
X
XFMR TRANSFORMER
Y
YD YARD
Y.D. YARD DRAIN
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
L
VESTIBULE
SERVER
SERVER
VEST
CONFERENCE
91 MW
INTEL
MRC
MRC
SUPPORT
CORRIDOR
COMM
VESTIBULE
CORRIDOR
STAIR
OFFICE
CORRIDOR
FEC-1
234 SF / 15 =
16 OCCUPANTS
456 SF / 100 =
5 OCCUPANTS
676 SF / 15 =
45 OCCUPANTS
GENERAL NOTES
APPLICABLE CODES: 2015 NFPA 101 LIFE SAFETY CODE
UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES
APPLICABLE NFPA DOCUMENTS
GROSS BUILDING AREA: 1,935 NSF OF RENOVATED AREA
23,612 GSF ENTIRE LOWER FLOOR
(BUILDING NSF AREA USED FOR CODE ANALYSIS ONLY, AND SHALL
NOT BE USED FOR CONSTRUCTION)
OCCUPANT LOAD: 66 OCCUPANTS TOTAL
BUILDING IS NOT PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM.
LEGEND
QUANTITY OF OCCUPANTS AND DIRECTION OF
EGRESS
FIRE EXTINGUISHER IN SEMI-RECESSED CABINET -
MOUNT WITH TOP OF CABINET AT 52" AFF
1-HOUR RATED PARTITION WITH 45-MINUTE
OPENING PROTECTION
XX
FEC-1
CONTRACTOR'S ACCESS TO BASEMENT FOR MATERIALS
AND PERSONNEL IS THROUGH THIS STAIR TOWER ONLY. THE
STAIR TOWER AND PUBLIC CORRIDORS NEED TO REMAIN
CLEAR AND OPEN AT ALL TIMES DURING CONSTRUCTION
FOR EMERGENCY EXITING. CONTRACTOR STAGING AND
LAY-DOWN AREA ON-SITE WILL BE COORDINATED WITH
CONTRACTING OFFICER AFTER AWARD.
SCALE: 1/16" = 1'-0" 16' 8' 16'0
BASEMENT FIRE PROTECTION PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
F I R
E
P
R O
T E
C T
I O
N
P
L A
N
A N
D
C
O D
E
A
N A
L Y
S I S
G-004
K H
A
K H
A
K H
A
B
M
R C
G
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T A
L
NOTE: THE FOLLOWING ARE DIRECT OR PARAPHRASED SECTIONS FROM THE
AFOREMENTIONED CODE UNLESS INDICATED BY ITALICS AND ARE DIRECTLY RELATED TO
THE PROJECT. STANDARDS NOT QUOTED ARE NOT APPLICABLE TO THIS PROJECT.
2015 NFPA 101 LIFE SAFETY CODE
CHAPTERS 1 THRU 6 NOT USED. REFER TO THE UFC 3-600-01.
SECT 3.3.190.3 BUSINESS OCCUPANCY. AN OCCUPANCY USED FOR THE TRANSACTION
OF BUSINESS OTHER THAN MERCANTILE.
SECT 6.2.2.3 ORDINARY HAZARD CONTENTS SHALL BE CLASSIFIED AS THOSE THAT
ARE LIKELY TO BURN WITH MODERATE RAPIDITY OR TO GIVE OFF A
CONSIDERABLE VOLUME OF SMOKE.
SECT A.6.2.2.3 ORDINARY HAZARD CLASSIFICATION REPRESENTS THE CONDITIONS
FOUND IN MOST BUILDINGS AND IS THE BASIS OF THE GENERAL
REQUIREMENTS OF THIS CODE.
SECT 7.2.1.2.3.2 DOOR OPENINGS IN MEANS OF EGRESS SHALL BE NOT LESS THAN
32-INCHES IN CLEAR WIDTH.
SECT 7.2.1.4.2 DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL UNDER ANY
OF THE FOLLOWING CONDITIONS:
1. WHERE SERVING A ROOM OR AREA WITH AN OCCUPANT LOAD OF 50
OR MORE.
TABLE 7.3.1.2 BUSINESS USE: 100 GROSS SF PER OCCUPANT.
ASSEMBLY USE, LESS CONCENTRATED USE, WITHOUT FIXED SEATING: 15
NET SF PER OCCUPANT
TABLE 7.3.3.1 0.3-INCH PER OCCUPANT REQUIRED WIDTH OF STAIRWAYS AND 0.2-INCH
PER OCCUPANT REQUIRED WIDTH OF LEVEL COMPONENTS FOR AREAS
OF BUILDING THAT ARE NOT HIGH HAZARD.
SECT 7.4.1.1 THE NUMBER OF MEANS OF EGRESS FROM ANY BALCONY, MEZZANINE,
STORY, OR PORTION THEREOF SHALL BE NOT LESS THAN TWO.
SECT 7.5.1.3.2 WHERE TWO EXITS, EXIT ACCESSES, OR EXIT DISCHARGES ARE
REQUIRED, THEY SHALL BE LOCATED AT A DISTANCE FROM ONE
ANOTHER NOT LESS THAN ONE-HALF THE LENGTH OF THE MAXIMUM
OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE
SERVED.
SECT 7.5.1.6 EXIT ACCESS FROM ROOMS OR SPACES SHALL BE PERMITTED TO BE
THROUGH ADJOINING OR INTERVENING ROOMS OR AREAS, PROVIDED
THAT SUCH ROOMS OR AREAS ARE ACCESSORY TO THE AREA SERVED.
FOYERS, LOBBIES, AND RECEPTION ROOMS CONSTRUCTED AS
REQUIRED FOR CORRIDORS SHALL NOT BE CONSTRUED AS
INTERVENING ROOMS.
SECT 9.9 PORTABLE FIRE EXTINGUISHERS SHALL BE SELECTED, INSTALLED,
INSPECTED, AND MAINTAINED IN ACCORDANCE WITH NFPA 10, STANDARD
FOR PORTABLE FIRE EXTINGUISHERS (2013).
NFPA 10
SECT 5.4.1.3 BUILDING IS CLASSIFIED AS EXTRA HAZARD
OCCUPANCY.
TABLE 6.2.1.1 4-A MINIMUM SIZE
1,000 SQ.FT. COVERAGE PER UNIT OF A
75-FEET MAXIMUM TRAVEL DISTANCE.
TABLE 6.3.1.1 80-B MINIMUM SIZE
50-FEET MAXIMUM TRAVEL DISTANCE
4-A:80-B:C PORTABLE FIRE EXTINGUISHERS PROVIDED, WITH 50-FEET
MAXIMUM TRAVEL DISTANCE.
SECT 39.1.5 THE CONTENTS OF BUSINESS OCCUPANCIES SHALL BE CLASSIFIED AS
ORDINARY HAZARD IN ACCORDANCE WITH SECTION 6.2.
SECT 39.1.7 THE OCCUPANT LOAD, IN NUMBER OF PERSONS FOR WHOM MEANS OF
EGRESS AND OTHER PROVISIONS ARE REQUIRED, SHALL BE
DETERMINED ON THE BASIS OF THE OCCUPANT LOAD FACTORS THAT
ARE CHARACTERISTIC OF THE USE OF THE SPACE OR SHALL BE
DETERMINED AS THE MAXIMUM PROBABLE POPULATION OF THE SPACE
UNDER CONSIDERATION, WHICHEVER IS GREATER.
SECT 39.2.3.1 THE CAPACITY OF MEANS OF EGRESS SHALL BE IN ACCORDANCE WITH
SECTION 7.3.
SECT 39.2.3.2 THE CLEAR WIDTH OF ANY CORRIDOR OR PASSAGEWAY SERVING AN
OCCUPANT LOAD OF 50 OR MORE SHALL BE NOT LESS THAN 44-INCHES.
SECT 39.2.5.2 DEAD-END CORRIDORS SHALL NOT EXCEED 50-FEET.
SECT 39.2.5.3.3 COMMON PATH OF TRAVEL SHALL NOT EXCEED 75-FEET.
SECT 39.2.6.2 TRAVEL DISTANCE SHALL NOT EXCEED 200-FEET.
SECT 39.3.3.2.1 INTERIOR WALL AND CEILING FINISH MATERIAL COMPLYING WITH
SECTION 10.2 SHALL BE CLASS A OR CLASS B IN EXITS AND IN EXIT
ACCESS CORRIDORS.
SECT 39.3.3.2.2 INTERIOR WALL AND CEILING FINISHES SHALL BE CLASS A, CLASS B, OR
CLASS C IN AREAS OTHER THAN THOSE SPECIFIED IN 39.3.3.2.1.
SECT 39.3.5 PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN EVERY
BUSINESS OCCUPANCY IN ACCORDANCE WITH 9.9.
LIMIT OF REMOVAL
R01
R01 R01
R01
R01
R01
R01
R01
R02R03
R03
R03
R03
R04
R04 R04
R04
R04
R04 R04
R04 R04
R04
R04
R05
R05
R05
R06
R06
R06
R06
R07
R07
R08
R10
R10
R12
R11
R12 R13
R14 R15
R14
REMOVAL KEYNOTES
R01 REMOVE DOOR, FRAME AND
HARDWARE COMPLETE
R02 REMOVE 6" CMU WALL COMPLETE
SHOWN HATCHED
R03 REMOVE GYPSUM BOARD AND STUD
PARTITION COMPLETE, INCLUDING
FASTENERS
R04 REMOVE GYPSUM BOARD AND
FURRING COMPLETE FULL HEIGHT OF
WALL, INCLUDING FASTENERS
R05 REMOVE GYPSUM BOARD, FURRING
AND RIGID INSULATION COMPLETE
FULL HEIGHT OF WALL, INCLUDING
FASTENERS
R06 REMOVE CASEWORK
R07 REMOVE RAISED WOODEN PLATFORM
R08 REMOVE WOOD ROLLER SHADE CASE
R09 NOT USED
R10 REMOVE SMART BOARDS AND RETURN
TO GOVERNMENT
R11 REMOVE CLOCKS AND REINSTALL
WHERE INDICATED
R12 REMOVE MARKER BOARD AND RETURN
TO GOVERNMENT
R13 REMOVE CHAIR RAIL
R14 PATCH EXISTING CMU WALL TO REMAIN
AT REMOVED PIPING - SEE MECH. AND
WALL TYPE C1 ON SHEET A-601
R15 TUCKPOINT EXISTING MASONRY INFILL
AND PATCH AS REQUIRED - SEE WALL
TYPE C1 ON SHEET A-601
REMOVAL LEGEND
INDICATES ITEMS TO BE REMOVED
REMOVAL GENERAL NOTES
1. REFER TO SHEET G-002 FOR ASBESTOS AND LEAD BASE PAINT AWARENESS.
2. REMOVE SUSPENDED ACOUSTICAL TILE CEILING AND ASSOCIATED GRID AND HANGARS
THROUGHOUT RENOVATED AREA.
3. REMOVE FLOOR FINISH, RESILIENT BASE, AND MASTIC THROUGHOUT THE RENOVATED
AREA.
4. AT EXISTING WALLS TO REMAIN, REMOVE ALL MISCELLANEOUS AND UNUSED ITEMS AND
PATCH WALLS FOR NEW FINISH AS SPECIFIED.
5. REMOVE AUDIO-VISUAL AND SECURITY EQUIPMENT THROUGHOUT RENOVATED AREA AND
RETURN TO GOVERNMENT.
6. REMOVE ALL FASTENERS, STRAPS, BOXES AND CONDUITS, HANGARS, MASTIC, ETC,
THROUGHOUT PROJECT AREA.
7. REMOVE ALL ABANDONED HVAC PIPING WITHIN CEILING PLENUM.
8. PATCH ALL HOLES IN FLOOR SLAB ABOVE.
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
REMOVAL PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
R E
M O
V A
L
P
L A
N
AD101
K H
A
K H
A
K H
A
B
M
R C
A
D D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
" M
ON
IT
OR
VESTIBULE
906A
MO
NI
TO
R
" M
ON
IT
OR
" M
ON
IT
OR
SHREDDERREFRIG
" M
ON
IT
OR
CA
ME
RA
CA
ME
RA
MONITOR
SERVER
SERVER
VEST
CONFERENCE
91 MW
INTEL
MRC
MRC
SUPPORT
CORRIDOR
COMM
VESTIBULE
CORRIDOR
STAIR
OFFICE
CORRIDOR
906B
921B
921A
(5) RELOCATED CLOCKS
A2
A2
A2
A2
A1
A1
A1
A1
F1
C1C1
C1C1
C1
C1D1
D1
D1
A1
A1
B1
SAFE
SAFE
A1
A-201
1E 1B
1A 1D
A-201
1F 1D
1C
A-201
1I 1H
1G 1J
A01
A02
A02
A03
A03
A03
A03
A03
A03
A04
A04
A05
A06
A07
A07
A07
A04
PRINTPRINT BADGE
SRP-3
SR
P-
SR
P-
P-
P-2P-2
A08
A08
A-202
4'-0" 3"R
A09
RE
LO
CA
TE
D
CL
OC
K
A-101
A10
A03
6"
'-5 3/
8"
'-7
'-6
6"
A07
6" 6'-
6"
'-5
'-5
5/ 8"
6'- 5 3
/8" 6"
2'-7"
ALIGN
2 5/8"4'-0 5/8"8'-6"32'-9 3/8"5 3/8"
2 5/8"5'-0 5/8"7'-6"8'-2 1/4"24'-7 1/8"5 3/8"
1. REFER TO SHEET G-002 FOR GENERAL NOTES.
2. REFER TO SHEET A-601 FOR WALL TYPES.
FLOOR PLAN KEYNOTES
A01 FIRE EXTINGUISHER IN SURFACE MOUNTED CABINET
A02 6" STEP AT RAISED ACCESS FLOOR
A03 EXISTING 4"+/- DEEP FLOOR TRENCH SHOWN DASHED - INFILL
WITH CONCRETE TO MATCH ADJACENT FLOOR SLAB
A04 4' x 4' MARKER BOARD WITH TOP AT 7'-2" ABOVE RAISED
ACCESS FLOOR
A05 (60) CELL PHONE LOCKER UNIT - MOUNT WITH TOP AT 5'-6"
ABOVE FLOOR SLAB. CELL PHONE LOCKER UNIT SHALL BE
EQUAL TO PART #6150W WITH WALNUT TRIM BY CHARNSTROM,
www.charnstrom.com, 1-800-328-2962
A06 RELOCATED EXISTING SHIELD
A07 3/4-INCH FIRE-RETARDANT PLYWOOD SHOWN DASHED -
INSTALL 8' TALL SHEET ON ALL WALLS FROM 8" ABOVE FINISH
FLOOR
A08 PROVIDE ADDITIONAL RAISED ACCESS FLOOR PEDESTALS AT
12" O.C. BENEATH SAFE
A09 PATCH HOLE IN FLOOR SLAB ABOVE AT REMOVED ANTENNA
CABLE
A10 PAINT ELECTRICAL PANEL AND CONDUIT TO MATCH WALL
A11 WRAP OPENING IN WALL WITH GYPSUM BOARD - SEE INTERIOR
ELEVATIONS FOR OPENING DIMENSIONS
FLOOR PLAN GENERAL NOTES
3 5 /8"
DRAIN BOX - SEE MECHANICAL
METAL STUD FRAMING
5/8" GYPSUM BOARD ON 3-5/8"
TO BOTTOM OF CEILING
FROM TOP OF RESILIENT BASE
ALUMINUM RETAINER - INSTALL
RESILIENT CORNER GUARD ON
FRAMING
2x6 FIRE-RETARDENT WOOD
5/8" GYPSUM BOARD ON
WALL
JAMB
JAMB
SCALE: 1-1/2" = 1'-0"
8"4"0 16"
CASED OPENING
6 3/4"
6 3/4"
FACE OF EXISTING CORRIDOR
3 5 /8"
1'- 3 5
/8"
NEW FINISHES
EXISTING
FINISHES
TO BOTTOM OF CEILING
FROM TOP OF RESILIENT BASE
ALUMINUM RETAINER - INSTALL
RESILIENT CORNER GUARD ON
FRAMING
2x6 FIRE-RETARDENT WOOD
5/8" GYPSUM BOARD ON
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
FLOOR PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
F L
O O
R
P
L A
N
A-101
K H
A
K H
A
K H
A
B
M
R C
A
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
SERVER
SERVER
VEST
CONFERENCE
91 MW
INTEL
MRC
MRC
SUPPORT
CORRIDOR
COMM
VESTIBULE
CORRIDOR
STAIR
OFFICE
CORRIDOR
SAFE
SAFE
ACOUSTICAL TILE CEILING
AT 9'-0" ABOVE RAISED
ACCESS FLOOR
ACOUSTICAL TILE CEILING
AT 8'-0" ABOVE FLOOR SLAB
EXPOSED
STRUCTURE
ACOUSTICAL TILE CEILING
AT 9'-0" ABOVE RAISED
ACCESS FLOOR
ACOUSTICAL TILE CEILING
AT 10'-0" ABOVE RAISED
ACCESS FLOOR
SPLICE NEW CEILING
GRID INTO EXISTING
CEILING GRIDHM HOLLOW METAL
DOOR AND FRAME SCHEDULE LEGEND
1. STC-50 AND RADIO FREQUENCY SHIELDED DOOR
ASSEMBLY.
2. STC-52 DOOR ASSEMBLY.
DOOR AND FRAME SCHEDULE NOTES
DOOR AND FRAME SCHEDULE
NO. SIZE TYPE MAT.
FRAME
TYPE MAT. DEPTH SHEET
DOOR
GLASS
KEY
TYPE
HDWR
SET
FIRE
RATING
DOOR
DETAILS NOTES
906A DA HM F01 HM 7-1/8" A-102 -- -- 3 45-MIN 23'-0" x 7'-0" x 1-3/4"
5905 DA HM F01 HM 7-1/8" A-102 -- -- 2 -- --3'-0" x 7'-0" x 1-3/4"
7, 9906B DA HM F01 HM 7-1/8" A-102 -- -- 4 -- 13'-0" x 7'-0" x 1-3/4"
907 DA HM F01 HM 7-1/8" A-102 -- -- 1 -- 13'-0" x 7'-0" x 1-3/4"
5920 DA HM F01 HM 7-1/8" A-102 -- -- 2 -- --3'-0" x 7'-0" x 1-3/4"
6, 8921A DA HM F01 HM 7-1/8" A-102 -- -- 3 45-MIN 23'-0" x 7'-0" x 1-3/4"
7, 9921B DA HM F01 HM 7-1/8" A-102 -- -- 4 -- 13'-0" x 7'-0" x 1-3/4"
6, 8
7, 9
SEE
SCHED.
SE
E
SC
HE
DU
LE
DA F01
SEE
SCHED.
SE
E
SC
HE
DU
LE
FLOOR LINE
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
FRAME TYPES
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
DOOR TYPES
5/8" TYPE X GYPSUM BOARD
HOLLOW METAL FRAME -
HOLLOW METAL DOOR
SPOT GROUT AT ANCHORS
BOARD
5/8" FIRE RETARDANT PLYWOOD
HOLLOW METAL FRAME -
HOLLOW METAL DOOR
SPOUT GROUT AT ANCHORS
EACH SIDE OF 3-5/8" METAL
OCCURRING SHOWN DASHED
5/8" TYPE X GYPSUM BOARD
LINE OF WALL WHERE
STUD FRAMING
3-1/2" SOUND BATT INSULATION
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB / HEAD
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB / HEAD
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB / HEAD
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB / HEAD
4"
SCALE: 3" = 1'-0"
2"0 8"
SILL
4"
SCALE: 3" = 1'-0"
2"0 8"
JAMB / HEAD
2"
4 7/8"
2"
6 1/8"
(2) LAYERS 5/8" TYPE X GYPSUM
DASHED
RADIANT BARRIER SHOWN
2"
6 1/8"
SOLID WITH SOUND DEADENING
COMPRESSION SOUND SEAL
MATERIAL
GROUT AT ANCHORS AND FILL
DOOR MANUFACTURER - SPOT
NEOPRENE SEAL
HOLLOW METAL FRAME BY
SPOT WELDED BACK-TO-BACK
ACOUSTIC BATT INSULATION
JAMB STUDS FULL HEIGHT - FILL
SOLID WITH SOUND DEADENING
MATERIAL
2"
6 1/8"
WELDED TO FRAME EACH END -
BLOCKING
STAINLESS STEEL THRESHOLD
SET IN ACOUSTIC SEALANT
NEOPRENE SEAL
BARRIER
RF TAPE - SEAL TO RADIANT
RADIANT BARRIER SHOWN DASHED
6" HIGH RAISED ACCESS FLOOR
ACOUSTIC DOOR ASSEMBLY
2x FIRE-TREATED WOOD BLOCKING
ACOUSTIC SEALANT
ALUMINUM THRESHOLD SET IN
ACOUSTIC SEALANT EACH SIDE
BOX
EPT
TAPE
RF
SOLID WITH SOUND DEADENING
COMPRESSION SOUND SEAL
MATERIAL
GROUT AT ANCHORS AND FILL
DOOR MANUFACTURER - SPOT
HOLLOW METAL FRAME BY
SPOT WELDED BACK-TO-BACK
ACOUSTIC BATT INSULATION
JAMB STUDS FULL HEIGHT - FILL
SOLID WITH SOUND DEADENING
MATERIAL
ACOUSTIC SEALANT EACH SIDE
RF TAPE
EACH SIDE
1/2" ACOUSTICAL SEALANT
6 1/8"
5/8" FIRE RETARDANT PLYWOOD
3-1/2" SOUND BATT INSULATION
MATCH RESILIENT
TREAD NOSING TO
RESILIENT STAIR
BASE
6 1/8"
ACOUSTIC DOOR ASSEMBLY
6" HIGH RAISED ACCESS FLOOR
2x FIRE-TREATED WOOD
EACH SIDE
1/2" ACOUSTICAL SEALANT SCALE: 1/4" = 1'-0" 4' 2' 0 4'
REFLECTED CEILING PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
R E
F L
E C
T E
D
C
E I L
I N
G
P
L A
N
D O
A
H
E D
U L
E
E L
E V
A T
I O
T
A I L
S
A-102
K H
A
K H
A
K H
A
B
M
R C
A
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
10'-0 1/2"
2'-6" 1'-3" 2'-6" 1'-3" 2'-6" 1/2"
2'-6" 2'-6" 2'-6" 2'-6" 1/2"
1'- 6"
2'- 2 1
/2" 2'-
6"
4'-6"21'-6"
2'-1 1/2"2'-0"
7'- 2"
32'-3 1/4"
2'-0" 3'-8 1/8" 2'-0" 4 7/8" 24'-2 1/4"
29'-9 1/4"21'-6"
3'-0" 5'-0 1/2" 2'-8 1/2" 2'-8 1/2" 8'-0 1/2"
7'- 2"
3'- 0"
9'- 3"
3'-0"1'-0"10 5/8"
4'- 0"
2'- 6"
3" 2'-
6"
3'- 0"
7'- 2"
16'-8 3/8"14'-0 1/2"
2'-3"
14'-0 1/2"
3'-0 1/2" 3'-7" 2'-0"
2'- 5 1
/2" 2'-
2 1 /2"
2'- 6"
4'- 0"
11'-4 1/2"
1'-4" 3'-4" 1'-4" 2'-8" 2'-8"1/2"
2'- 5 1
/2" 2'-
2 1 /2"
2'- 6"
2'-10" 2'-10" 2'-10" 2'-10"1/2"
18"
MTRSP
EC
SP
EC
SAFE
SHIELD
60" MONITOR
(5) RELOCATED CLOCKS60" MONITOR60" MONITOR
60" MONITOR
VTC
CAMERA
60" MONITOR60" MONITOR
VTC
CAMERA
18"
MTR
18"
MTR
18"
MTR
18"
MTR
18"
MTRNI
PR
SI
PR
JW
IC
S
OPEN
OPEN
4'x4'
MARKERBOARD
4'x4'
MARKERBOARD
7'- 2"
2'- 5 1
/2" 2'-
2 1 /2"
2'- 6"
11'-0 1/2"
1/2" 1'-4" 3'-6" 1'-4" 3'-6" 1'-4"
2'- 5 1
/2" 1'-
4 1 /2"
2'- 0"
7'- 2"
5'-3 7/8"
3'-11 1/2"
2'-1 1/2" 2'-0"
3'-
2'-
0"
2'-8 1/2" 2'-8 1/2"
3 4 2
43 2 1 5
A B C
D E F
JI
18"
MTR
SHIELD SHIELD
6'- 6"
3'-6"3'-6"
HG
1/
2"PRINT
4'x4'
MARKERBOARD
7'- 2"
2x6 WOOD BLOCKING
PROVIDE (2) ROWS OF
WITHIN WALL FOR
MOUNTING MONITOR
AND VTC CAMERA
2x6 WOOD BLOCKING
PROVIDE (4) ROWS OF
WITHIN WALL FOR
MOUNTING MONITOR
AND VTC CAMERA
FINISHES: CABINETS: PL-1
COUNTERTOP: SS-1
FINISHES: CABINETS: PL-1
COUNTERTOP: SS-1
FINISHES: CABINETS: PL-1
COUNTERTOP: SS-1
WRAP OPENING
WITH GWB
WRAP OPENING
WITH GWB
PROVIDE 2x6 WOOD BLOCKING
WITHIN WALL FOR MOUNTING
RELOCATED EXISTING SHIELDS
2'- 6"
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
INTERIOR ELEVATIONS
1 NOTE: ALL DETAILS ARE LOCATED
ON SHEET A-202, U.N.O.
SCALE: 3/8" = 1'-0" 1' 1'0 3'
INTERIOR ELEVATIONS
SHIELD
N A-201
3D
A-201
3D
A-201
3C
A-201
3A
A-201
3B
3B
REV
NOTE: ALL DETAILS ARE LOCATED
ON SHEET A-202, U.N.O.
14'-2 7/8" 2'-5 1/2"
1" 2"
1'-0" 9" 1'-0" 9" 1'-0" 9" 1'-0" 9" 1'-0" 9" 1'-0" 9" 1'-0" 9" 1'-0" 9"
7 6
2'- 6"
6" 7 3
/8"
2'- 6"
6" 7 3
/8"
2'- 6"
6" 7 3
/8"
14'-1" 6 1/2" 2'-4"
L
8 7 6
2'- 6"
6" 7 3
/8"
7 610
8'-4"
M
16'-11 1/2"
1'-5" 1'-0" 1"
1'-0" 1" 1'-0" 1'-5" 1'-0" 2"2" 1'-0"
2'-4" 6 1/2"
1'-3 1/4" 2'-5 5/8" 1'-3 1/4" 6 1/2"
2'-4"
K
2" 1'-0" 2'-6" 1'-0" 2'-6" 1'-0" 2'-6" 1'-0" 2'-6"
14'-2"
2'-6 1/4"
2'-6 1/4"
14'-2"2" 1'-0" 2'-6" 1'-0" 2'-6" 1'-0" 2'-6" 1'-0" 2'-6"
8'- 4"
2" 1'-
0" 2'-
6" 1'-
0" 2'-
6" 1'-
0" 2"
6 1/2" 2'-4"
6 1 /2"
2'- 4" 1"
1"
14'-1 3/4"
14'-1 3/4" 2'- 5 1
/2"
5'- 0 1
/8"
REV
SCALE: 3/8" = 1'-0" 1' 1'0 3'
LARGE SCALE PLAN
N2
FINISHES: CABINETS: PL-3
COUNTERTOP: QT-1
FINISHES: CABINETS: PL-3
COUNTERTOP: QT-1
FINISHES: CABINETS: PL-3
COUNTERTOP: QT-1
FINISHES: CABINETS: PL-3
COUNTERTOP: QT-1
14" x 36" TRANSLUCENT
RESIN PANEL (TYP.)
14" x 36" TRANSLUCENT
RESIN PANEL (TYP.)
14" x 36" TRANSLUCENT
RESIN PANEL (TYP.)
14" x 36" TRANSLUCENT
RESIN PANEL (TYP.)
SHIELD PROVIDED AND
INSTALLED BY GOVERNMENT
I N
T E
R I O
R
E
L E
V A
T I O
N S
A-201
K H
A
K H
A
K H
A
B
M
R C
A
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
FRONT - OPEN KNEE
SPACE WHERE OCCURING
3/4" DRAWER OR DOOR
COUNTERTOP WITH
SOLID SURFACE
1x4 WOOD BLOCKING
5-MM HOLES AT 1" O.C.
SEE ELEV. FOR QUANTITY
3/4" ADJUSTABLE SHELF -
3/4" FINISHED CABINET
BOTTOM AND VALANCE
ELECTRICAL
LIGHT FIXTURE - SEE
2 1/2"
1" 1/2
1 1 /4"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
1'-1 1/2"
ON PARTICLE BOARD
SUBSTRATE
EASED FRONT EDGE
SCALE: 3/4" = 1'-0" 2'1'0 4'
DOOR WALL CABINET
4"SCALE: 3" = 1'-0" 2"0 8"
COUNTERTOP DETAIL
FINISH BASE AS SCHEDULED
2x WOOD BASE FRAME WITH
DRAWER BOX
AT ALL EDGE JOINTS
1/4" BACKING - ROUT IN
1x4 WOOD BLOCKING
3/4" DRAWER FRONT
2'-1"
2'-0"
4"
3/ 4"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
3"
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
DRAWER BASE CABINET
6" 6"
1 3 /4"
2'- 5 1
/2"
FINISH BASE AS SCHEDULED
2x WOOD BASE FRAME WITH
DRAWER BOX
AT ALL EDGE JOINTS
1/4" BACKING - ROUT IN
1x4 WOOD BLOCKING
3/4" DRAWER FRONT
2'-1"
2'-0"
4"
3/ 4"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
3"
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
DRAWER BASE CABINET
1'- 0"
1 3 /4"
2'- 5 1
/2"
FILE
FILE
FILE
FINISH BASE AS SCHEDULED
2x WOOD BASE FRAME WITH
5 MM HOLES AT 1" O.C.
AT ALL EDGE JOINTS
1/4" BACKING - ROUT IN
1x4 WOOD BLOCKING
1" ADJUSTABLE SHELF
2'-1"
2'-0"
4" 1'-
3/
4"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
3"
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
DOOR BASE CABINET
1 3 /4"
2'- 5 1
/2"
4" 4"
PENCIL DRAWER
1x4 WOOD BLOCKING
2'-1"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
KNEE SPACE
2'- 5 1
/2"
FINISH BASE AS SCHEDULED
2x WOOD BASE FRAME WITH
AT ALL EDGE JOINTS
1/4" BACKING - ROUT IN
1x4 WOOD BLOCKING
2'-1"
2'-0"
4" 1'-
0 1 /4"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
3"
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
DOOR BASE CABINET
1 3 /4"
1'- 6"
2'- 6"
6"
2 1 /2"
1'- 1 1
/2" 6"
6" 2"
2'-4" 6 1/2"
3/4"
1" 2'-3"
2'- 6"
PLASTIC LAMINATE PL-3 BASE
TAPED EDGES EACH SIDE
FRONT WITH PLASTIC LAMINATE
3/4" WALNUT PLYWOOD WITH
3/4" PLYWOOD CABINET BOX,
FIXED SHELF, AND DRAWER
ON PARTICLE BOARD SUBSTRATE
QUARTZ QT-1 COUNTERTOP
2x6 WOOD FRAMING
1/8" x 1/8" SAWCUT EACH SIDE
EDGES AND KERFED BACK
SCALE: 3/4" = 1'-0" 2'1'0 4'
DRAWER BASE CABINET
3/4" WALNUT WITH EASED
PL-3 ON ALL EXPOSED SURFACES
FLUSH INSET
DRAWER
EDGE
EASED
6"
2'- 4"
2"
2'-4" 6 1/2"
2'- 6"
PLASTIC LAMINATE PL-3 BASE
TAPED EDGES EACH SIDE
3/4" WALNUT PLYWOOD WITH
3/4" HARDWOOD PLYWOOD FLUSH
INSET DOOR WITH TAPED EDGES
ON PARTICLE BOARD SUBSTRATE
QUARTZ QT-1 COUNTERTOP
2x6 WOOD FRAMING
1/8" x 1/8" SAWCUT EACH SIDE
EDGES AND KERFED BACK
SCALE: 3/4" = 1'-0" 2'1'0 4'
KNEE SPACE
3/4" WALNUT WITH EASED
EDGE
EASED
2 1 /2"
2'- 0"
3 1 /2"
2" 4"
WIRE MANAGEMENT SLOT
6"
2'- 4"
2"
2'-4"
2'- 6"
PLASTIC LAMINATE PL-3 BASE
TAPED EDGES EACH SIDE
3/4" WALNUT PLYWOOD WITH
ON PARTICLE BOARD SUBSTRATE
QUARTZ QT-1 COUNTERTOP
2x6 WOOD FRAMING
1/8" x 1/8" SAWCUT EACH SIDE
EDGES AND KERFED BACK
SCALE: 3/4" = 1'-0" 2'1'0 4'
KNEE SPACE
3/4" WALNUT WITH EASED
EDGE
EASED
2 1 /2"
2 1 /2"
1'- 1 1
/2" 6"
6" 2"
1" 2"
2'- 6"
SCALE: 3/4" = 1'-0" 2'1'0 4'
FINISHED END PANEL
1'-0"
PLASTIC LAMINATE PL-3 BASE
FRONT WITH PLASTIC LAMINATE
3/4" PLYWOOD CABINET BOX,
FIXED SHELF, AND DRAWER
AND FINISHED END PANEL ON
QUARTZ QT-1 COUNTERTOP
PL-3 ON ALL EXPOSED SURFACES
3/4"
6"
PARTICLE BOARD SUBSTRATE
DRAWER BOX
2'- 4"
2"
2'- 6"
EACH SIDE
ON PARTICLE BOARD SUBSTRATE
QUARTZ QT-1 COUNTERTOP
SCALE: 3/4" = 1'-0" 2'1'0 4'
KNEE SPACE
EDGE
EASED
2 1 /2"
PLYWOOD SUBSTRATE2'-4" 2 1/4"
PLASTIC LAMINATE PL-3 BASE
TAPED EDGES EACH SIDE OF 3/4"
3/4" WALNUT PLYWOOD WITH
2x6 x 48" WOOD BLOCKING
1x4 WOOD CLEAT
1'-6"
16-GA. SHEET METAL PLATE
OR WOOD BLOCKING
TOP WITH INTEGRAL BACK
SPLASH
SOLID SURFACE COUNTER-
2 1 /2"
SCALE: 3/4" = 1'-0" 2'1'0 4'
WRITING COUNTER
3'- 6"
AT BRACKET SHOWN DASHED
1-1/2" THICK BRACKET CLAD
PLASTIC LAMINATE PL-1
1'- 9"
3" 1 1
/4" 1'-
4 3 /4" 1'-1" 2"
BRACKETS - CUT PANEL TO ACCOMMODATE
PANEL WITH TWO (2) MOUNTING
3/8" x 14" x 36" TRANSLUCENT RESIN
WIRE MANAGEMENT SLOT
6 1/2"
BRACKETS - CUT PANEL TO ACCOMMODATE
PANEL WITH TWO (2) MOUNTING
3/8" x 14" x 36" TRANSLUCENT RESIN
WIRE MANAGEMENT SLOT
BRACKETS - CUT PANEL TO ACCOMMODATE
PANEL WITH TWO (2) MOUNTING
3/8" x 14" x 36" TRANSLUCENT RESIN
WIRE MANAGEMENT SLOT
C A
S E
W O
K
C
T I O
N S
A-202
K H
A
K H
A
K H
A
B
M
R C
A
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
NOTES
ROOM FINISH SCHEDULE
NO. DESCRIPTION FLOOR BASE
NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
MAT. FIN. MAT. FIN. HEIGHTMAT. FIN. MAT. FIN. MAT. FIN.
803 CORRIDOR -- -- 1----------------------
887 STAIR -- -- 1----------------------
901 CORRIDOR CPT-1 RB-1 2, 48'-0"--ATC-2SRP-1GWBSRP-1GWBSRP-1GWBSRP-1GWB
904 OFFICE -- -- 1----------------------
905 SERVER PL-2 RB-1 3, 7----EXPGWBGWBGWBP-1GWB
906 VESTIBULE CPT-1 RB-1 5, 79'-0"--ATC-1GWBGWBGWBGWB
907 CONFERENCE CPT-2 RB-1 5, 79'-0"--ATC-1GWBGWBGWBGWB
911 CORRIDOR -- -- 1--------------
918 MRC CPT-2 WB-1 5, 6, 710'-0"--ATC-1P-1GWBP-1GWBP-1GWBSRP-3GWB
919 MRC SUPPORT CPT-2 WB-1 5, 6, 710'-0"--ATC-1SRP-3GWBSRP-3GWBP-1GWBP-1GWB
921 VESTIBULE CPT-2 WB-1 6, 79'-0"--ATC-1GWBGWBGWBP-1GWB
929 COMM -- -- 1----------------------
931 VESTIBULE CPT-1 EX WB --8'-0"--EXP-1GWBP-1GWBP-1GWBP-1GWB
920 SERVER PL-2 RB-1 3, 7----EXPP-1GWBP-1GWBP-1GWBP-1GWB
908 91 MW INTEL CPT-1 RB-1 5, 79'-0"--ATC-1GWBGWBGWBGWB
REFER TO COLOR SCHEDULE FOR ALL INTERIOR
FINISHES
ATC ACOUSTICAL TILE CEILING
EX EXISTING
EXP EXPOSED STRUCTURE
GWB GYPSUM WALLBOARD
P PAINT
PL PLASTIC LAMINATE
PLYWD PLYWOOD
RAF RAISED ACCESS FLOOR
RB RESILIENT BASE
SRP SCUFF-RESISTANT PAINT
SS SOLID SURFACE
WB WOOD BASE
ROOM FINISH SCHEDULE LEGEND
1. NO INTERIOR FINISH WORK REQUIRED IN THIS
ROOM.
2. SALVAGED AND REINSTALLED ATC-2 WITH NEW
GRID.
3. INSTALL 8' TALL SHEET OF 3/4-INCH FIRE-
RETARDANT PLYWOOD ON ALL WALLS FROM 8"
ABOVE FINISH FLOOR.
4. INSTALL IMPACT-RESISTANT GYPSUM BOARD
ON THE LOWER 48" OF WALLS WITHIN THIS
ROOM.
5. SEE FLOOR PLAN FOR PAINT LOCATIONS.
6. SEE DETAIL 3/A-601 FOR WOOD BASE AND
CHAIR RAIL.
7. INSTALL 6" HIGH RAISED ACCESS FLOOR
THROUGHOUT THIS ROOM. CEILING HEIGHTS
ARE FROM TOP OF RAISED ACCESS FLOOR.
ROOM FINISH SCHEDULE NOTES
P-1P-1 P-1
P-1
SRP-3
P-2
P-1 P-1
P-1
P-1
P-1
P-2 P-1 P-1
P-1/P-2
P-1 P-1 P-1
A1
SCALE: 3/4" = 1'-0" 2'1'0 4'
WALL TYPES
6 1/8"
6" HIGH RAISED ACCESS FLOOR
ONE LAYER 5/8" TYPE X GWB
TWO LAYERS 5/8" TYPE X GWB
FRAMING AT 16" O.C.
3-5/8" 16 GA METAL STUD
FILL VOID WITH INSULATION
16 GA DEFLECTION TRACK -
AT WALL TYPE A2)
EACH SIDE (FIRESTOPPING
3/4" ACOUSTICAL SEALANT
EACH SIDE (FIRESTOPPING
1/2" ACOUSTICAL SEALANT
METAL STUD FRAMING
3-1/2" SOUND BATTS - FASTEN TO
GLUED AND SCREWED AT 12" O.C.
5/8" FIRE-RETARDANT PLYWOOD
BEADS OF SEALANT
RADIANT BARRIER SHOWN DASHED
AT 32" O.C. - BED IN 2 CONT.
16 GA CONT. TRACK ANCHORED
AR
EA
CO
NT
RO
LL
ED
AR
EA
UN
CO
NT
RO
LL
ED
C1
EXISTING 6" CMU - GROUT FULL
DASHED
FRAMING AT 16" O.C.
3-5/8" 16 GA METAL STUD
BOTTOM OF STRUCTURE
BEADS OF SEALANT
AT 32" O.C. - BED IN 2 CONT.
16 GA CONT. TRACK ANCHORED
ALL HOLES AND VOIDS AND
6"
AR
EA
CO
NT
RO
LL
ED
AR
EA
UN
CO
NT
RO
LL
ED
1/2" ACOUSTICAL SEALANT
INSTALL ACOUSTIC SEALANT
AT PERIMETER AND ALL
PENETRATIONS
TWO LAYERS 5/8" TYPE X GWB
BOTTOM OF STRUCTURE
FILL VOID WITH INSULATION
16 GA DEFLECTION TRACK -
EACH SIDE
3/4" ACOUSTICAL SEALANT
D1
EXISTING CONCRETE
2" R-12 RIGID INSULATION -
BOTTOM OF STRUCTURE
16 GA CONT. TRACK
BASEMENT WALL
5 3/8"
ONE LAYERS 5/8" TYPE X GWB
RADIANT BARRIER / VAPOR
SEAL PERIMETER AND JOINTS
FRAMING AT 16" O.C.
1-5/8" 16 GA METAL STUD
E1
4 7/8"
AT 32" O.C. - BED IN 2 CONT.
16 GA CONT. TRACK ANCHORED
BEADS OF SEALANT
FRAMING AT 16" O.C.
3-5/8" 16 GA METAL STUD
ONE LAYER 5/8" TYPE X
GWB EACH SIDE
F1
ELEV. = 107'-8"
TOP OF WALL
NOTE: PAINT BOTH SIDE OF WALLS
FULL HEIGHT FROM FLOOR SLAB TO
UNDERSIDE OF STRUCTURE ABOVE
ELEV. = 100'-0"
T.O. FLOOR SLAB
AT WALL TYPE A2)
ICD/ICS 705 WALL C
A2
ELEV. = 100'-0"
T.O. FLOOR SLAB
TO METAL STUD FRAMING
3-1/2" SOUND BATTS - FASTEN
RADIANT BARRIER SHOWN
ELEV. = 100'-0"
T.O. FLOOR SLAB
B1
EXISTING CONCRETE
2" R-13 RIGID INSULATION
BOTTOM OF STRUCTURE
OVER VAPOR RETARDER
BASEMENT WALL
2 5/8"
ONE LAYERS 5/8" TYPE X GWB
ACOUSTICAL TILE CEILING
INSTALLED ON 2" METAL Z
FURRING AT 24" O.C.
ELEV. = 100'-0"
T.O. FLOOR SLAB
BARRIER SHOWN DASHED
ELEV. = 100'-0"
T.O. FLOOR SLAB
STC 50 MINIMUM PER GA FILE NO. WP 1052
NON-RATED
ICD/ICS 705 WALL C
STC 50 MINIMUM PER GA FILE NO. WP 1052
1-HOUR FIRE RATED PER ULC DESIGN W415
NON-RATED
NON-RATED
ICD/ICS 705 WALL C (MODIFIED)
STC 40 FOR 6" HOLLOW CMU PARTITION
STC 42 (ASSUMED) FOR GYPSUM BOARD PARTITION
STC 50 MINIMUM
NON-RATED
NOT USEDSTC 58 FOR 8" CONCRETE WALL
NON-RATED
PIPE OR CONDUIT - SIZE
VARIES
CONDUITS UP TO 4"Ø -
AND CONDUITS LARGER
24" x 24" PANELS FOR PIPES
THAN 4"Ø
GYPSUM BOARD - 16" x 16"
TWO LAYERS 5/8" TYPE X
PANELS FOR PIPES AND
ELECTRICAL DRAWINGS FOR
AND INSPECTION PORTS
NON-CONDUCTIVE BREAKS
DUCT OR BEAM ALL SIDES
DUCT OR BEAM - SIZE
VARIES
METAL BRIDGING TIGHT TO
MINIMUM 8" LARGER THAN
SIDES
DUCT OR BEAM SIZE ALL
TWO LAYERS 5/8" TYPE X
GYPSUM BOARD PANELS
1/2" x 1-1/2" FIRESTOPPING
SEALANT ALL SIDES
SCALE: 1-1/2" = 1'-0" 8"4"0 16"
PENETRATION DETAILS
1/2" x 1-1/2" FIRESTOPPING
SEALANT ALL SIDES
NOTE: SEE MECHANICAL AND
4"
SCALE: 3" = 1'-0"
2"0 8"
WOOD TRIM
2x WOOD BLOCKING
3/4" WALNUT CHAIR RAIL WITH
4" 4"
3/8
5/8
3/8
5/8
3/8
5/8
KERFED BACK - STAIN ST-1
KERFED BACK - STAIN ST-1
3/4" WALNUT BASE WITH
1/8" x 1/8" SAWCUT
1/8" x 1/8" SAWCUT
3'-0" A.F.F.
T.O. CHAIR RAIL
R O
N
I S
H
S
C H
E D
U L
E
A N
D
W
A L
L
T
Y P
E S
A-601
K H
A
K H
A
K H
A
B
M
R C
A
D
W G
K H
A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
A
B
M I T
T A
L
B
M I T
T A
L
J U
N
S
U B
M I T
T
HD
HD
F
SD
SD
SD
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
S
U B
M I T
T A
S
U B
M I T
T A
L
M
B
M I T
T A
J
N
F I R
E
A
L A
M
O V
A L
F L
O O
R
P
L A
N
FD101
M D
W
S C
T
F E
I
B
M
R C
F
D d w g
M D
W
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
FIRE ALARM REMOVAL FLOOR PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
( )FIRE ALARM KEYNOTES:
EXISTING DEVICE TO REMAIN.
EXISTING DEVICE TO REMAIN. REINSTALL IN NEW CEILING
AT THIS APPROXIMATE LOCATION.
REMOVE FOR REUSE ON NEW WALL. SEE SHEET FA101.
NOTE: SEE SHEET EG101 FOR FIRE ALARM
SYMBOLS AND GENERAL ELECTRICAL NOTES.
SERVER
SERVER
VESTIBULE
CONFERENCE
91 MW
INTEL
MRC
MRC
SUPPORT
CORRIDOR
COMM
VESTIBULE
CORRIDOR
STAIR
OFFICE
CORRIDOR
T
T
5 8
SD
SD
SD
SD SD
HD
F
SD
EXISTING
MM
CM
MM
PS
MM
CMMMPS
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
A M
E
D W
N
B
Y
C K
D
B
Y
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K A
P P
R
D A
T E
F I L
E
N
U M
B E
R
S I Z
E
S U
B M
I T
T E
D
B
Y
P L
A
L E
I S
S U
E
D
A T
E
D A
T E
M A
R K
D E
S C
R I P
T I O
N
C O
N T
R A
SHEET
IDENTIFICATION
D A
T E
A P
P R
SHEET OF
M I N
R
S
E
N O
R T
H
D
A K
O T
A
XX8
J U
J U
A N
S I
D
X
R E
N O
V A
F
I C
E
S
P A
C E
B U
I L D
I N
G
B
M I T
T A
L
S
U B
M I T
T A
S
U B
M I T
T A
L
M
B
M I T
T A
N
F I R
E
A
L A
O
A
N
FA101
M D
W
S C
T
F E
I
B
M
R C
F
A d w g
M D
W
SCALE: 1/4" = 1'-0" 4' 2' 0 4'
FIRE ALARM FLOOR PLAN
N1
N
PLAN
NORTH
TRUE
NORTH
( )FIRE ALARM KEYNOTES:
PROVIDE A SIGNAL ISOLATION MODULE FOR ALL NOTIFICATION APPLIANCE CIRCUITS ENTERING OR
LEAVING THE SECURE PERIMETER BOUNDARY. SIMPLEX 4090 9007 OR SIMILAR.
CONNECT TO EXISTING CORRIDOR FIRE ALARM SYSTEM CABLING.
LOCATE PIPING ABOVE THE EQUIPMENT RACKS AND ABOVE GENERAL ROOM SPACES.
LOCATE PIPING BELOW RAISED FLOOR SYSTEM.
PROVIDE REMOTE POWER SUPPLY FOR FIRE ALARM SYSTEM. COORDINATE WITH THE ELECTRICAL CONTRACTOR TO PROVIDE DEDICATED 120V CIRCUIT. SHARE CONNECTION WITH ASPIRATING SMOKE
DETECTOR DEVICE.
ASPIRATING SMOKE DETECTORS - PROVIDE FOUR ZONE AIR SAMPLING DETECTOR AND CONTROL
PANEL (VESDA VLS-700 OR APPROVED EQUAL). COORDINATE POWER CONNECTION WITH ELECTRICAL
CONTRACTOR.
WITHIN EACH SECURE PERIMETER, PROVIDE RELAY FUNCTIONALITY TO DE-ENERGIZE ALL EQUIPMENT UPON FIRE (ALARM) DETECTION. AN AUDIBLE ALARM WILL BE GENERATED BY THE ASPIRATING SMOKE DETECTOR AT LOW DETECTION (TROUBLE). AT ELEVATED DETECTION (ALARM) THE SYSTEM IS TO
OPERATE THE MONITOR AND RELAY MODULES TO DEACTIVATE THE MAIN BREAKER OF THE
PANELBOARD. PROVIDE WIRING AND RELAY EQUIPMENT TO ACCOMMODATE THIS CONTROL LOGIC.
PROVIDE TWO DUAL INPUT MONITOR MODULES FOR THE ALARM AND TROUBLE CONTACTS OF THE
ASPIRATING SMOKE DETECTOR DEVICE.
PROVIDE DIELECTRIC BREAKS AT RACEWAY PENETRATING THE PERIMETER WALL. LOCATE RACEWAY
ADJACENT TO OTHER SERVICES, POSITION SHOWN ARE DIAGRAMMATIC ONLY.
GENERAL NOTES:
1. PROVIDE ALL NECESSARY PROGRAMMING, HARDWARE AND SOFTWARE CHANGES REQUIRED TO
INTEGRATE THE NEW DEVICES/MODIFICATIONS INTO THE BASE HEAD END SYSTEM. THE EXISTING FACP HEAD END UNIT IS SIMPLEX 4100 U INSTALLED IN 1997. THE CONTRACTOR SHALL PERFORM
ALL FIRE ALARM SYSTEM PROGRAMMING, INCLUDING PROGRAMMING THE MONACO CENTRAL
RECEIVING STATION.
2. ALL WIRING FOR FIRE ALARM/MASS NOTIFICATION SYSTEM SHALL BE INSTALLED IN CONDUIT.
NOTIFICATION APPLIANCE CIRCUITS (NAC) AND SIGNAL LINE CIRCUITS (SLC) SHALL BE INSTALLED IN SEPARATE CONDUITS. SLC CIRCUITS SHALL BE CLASS A, STYLE Z AND NAC CIRCUITS SHALL BE
CLASS A, STYLE 6.
NOTE: SEE SHEET EG101 FOR FIRE ALARM
SYMBOLS AND GENERAL ELECTRICAL NOTES.
C H
A N
I C
M
B O
G
E N
D
MG101
B J K
H D
S
B J K
B J K
HPC
MPC
REFRIGERANT DISCHARGE
LPS (XX)
RD
CD
HCR
HCS
MPS (XX)
HPS (XX)
HWR
HWS
CWR
CWS
PC
LPC
RS REFRIGERANT SUCTION
COIL CONDENSATE DRAIN
LOW PRESSURE STEAM (PRESSURE)
MEDIUM PRESSURE STEAM (PRESSURE)
HIGH PRESSURE STEAM (PRESSURE)
LOW PRESSURE CONDENSATE
MEDIUM PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATE
PUMPED CONDENSATE
HOT/CHILLED WATER RETURN
HOT/CHILLED WATER SUPPLY
HEATING WATER RETURN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
HEATING WATER SUPPLY
DESCRIPTIONSYMBOLDESCRIPTIONSYMBOL
RL REFRIGERANT LIQUID
EGS
EGR
FOR
FOS
FOV
CR
CS
HPWR
HPWS
A
AS-
CONDENSER WATER RETURN
FUEL OIL VENT
FUEL OIL SUPPLY
FUEL OIL RETURN
ETHYLENE GLYCOL SUPPLY
ETHYLENE GLYCOL RETURN
CONDENSER WATER SUPPLY
HEAT PUMP WATER RETURN
HEAT PUMP WATER SUPPLY
INLINE PUMP
AIR VENT - MANUAL
AIR VENT - AUTOMATIC
AIR SEPARATOR
FLEX CONNECTOR
PROPYLENE GLYCOL RETURN
PROPYLENE GLYCOL SUPPLY
PGR
PGS
MV
DESCRIPTIONSYMBOL
MU
MAKE-UP WATER
TW
EXPANSION - JOINT
PIPE ANCHOR - MAIN
THERMOMETER
THERMOMETER WELL
PIPE ANCHOR - INTERMEDIATE
BALL JOINT
ALIGNMENT GUIDE
EXPANSION - LOOP
FLOWMETER - ORIFICE
PITCH OF PIPE, RISE (R) OR DROP (D)
R
D
FLOWMETER - VENTURI
FS
FLOW SWITCH
PS
PRESSURE SWITCH
HANGER - ROD
H
HANGER - SPRINGH
PUMP SUCTION DIFFUSER
PSD
DUPLEX STRAINER
FLOAT THERMOSTATIC TRAP
PIPING AND SPECIALTIES
TURNING VANES
ROUND DUCT (SECTION)
ROUND DUCT (DIAMETER)
RECTANGLE DUCT (WIDTH/HEIGHT)
RELIEF OR EXHAUST AIR DUCT (UP)
SUPPLY, OUTSIDE OR MIXED AIR DUCT (UP)
VOLUME CONTROL DAMPER
OPPOSED BLADE DAMPER
FIRE/SMOKE DAMPER (IN VERTICAL DUCT)
FIRE/SMOKE DAMPER (IN HORIZONTAL DUCT)
SMOKE DAMPER (IN VERTICAL DUCT)
FIRE DAMPER (IN VERTICAL DUCT)
SMOKE DAMPER (IN HORIZONTAL DUCT)
FIRE DAMPER (IN HORIZONTAL DUCT)
PARALLEL BLADE DAMPER
FD
SD
FD
SD
FSD
FSD
RETURN AIR DUCT (UP)
R
FLAT OVAL DUCT (WIDTH/HEIGHT)
BACKDRAFT DAMPER
ELEVATION CHANGE (RISE OR DROP)
HIGH EFF. TAKE OFF FITTING WITH VOLUME DAMPER
INSULATED FLEXIBLE DUCTWORK
RETURN AIR DUCT (SECTION)
SUPPLY, OUTSIDE OR MIXED AIR DUCT (DOWN)
RELIEF OR EXHAUST AIR DUCT (SECTION)
ROUND DUCT (UP)
FLEXIBLE DUCTWORK TO EQUIPMENT
VD
BD
DU…