Questions_and_Answers_2.pdf
PDF 10 KB Posted
- Attached to
- Vertical Carousel Storage Unit Federal contract opportunity
- Solicitation number
- FA4419-16-Q-0015
About this file
Updated questions and answers 2 new questions listed first.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Updated_Questions_and_Answers_2.pdf | ||
| MFR_Amendment_Vertical_Carousel.pdf | ||
| Updated_Questions_and_Answers_29_Jul_16.pdf | ||
| Combo_Vertical_Lift_FBO_Post_v2_7-27-16.pdf | ||
| Questions_and_Answers.pdf | ||
| IBR_Clauses_and_Provisions_Vertical_Carousel.pdf | ||
| 52.212-4_Evaluation.pdf | ||
| Combo_Vertical_Lift_FBO_Post.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions and Answers
---New Questions— Is a hand crank required so that the unit must be able to have access to all items during a power outage?
-Yes, crank is required in case of power outage.
Are rollers required to move the machine instead of having to totally dismantle in case of relocation?
-Rollers are needed in order to move the unit within the chosen location. Moving the unit outside of the desired location may require the unit to be dismantled.
---End new questions---
What is being stored in these units?
-KC46 ground support equipment such as test equipment, small tool boxes, multimeter, powered hand tools, ground cords, headsets, PPE (Personal Protective Equipment), common and peculiar support equipment.
Max height, depth and width of each unit?
-Must not exceed 9'10.6''H 136.8”W x 76.8”D
How many carriers or how much surface space is needed per unit?
-11 carriers
Minimum clear height between carriers?
-2 Levels of 6.28” Clear Height
Capacity needed in lbs/sq ft?
-Cubic Storage per Unit: 230 ft³ (6.52 m³) Storage Area per Unit:) 423.6 ft² (39.38 m²) Unit Weight (Empty) 5166 lb. (2343 kg Unit Weight (Loaded )8823 lb. (4002 kg
Minimum clear depth of each carrier?
-24.7”D
Minimum clear width of each carrier?
-112.2”W
Desired voltage?
-3/PE 220V (50/60 Hz)