Questions building 450.docx

DOCX document 11 KB Posted

Attached to
Altus AFB, Bldg 450 Roof Replacement Federal contract opportunity
Solicitation number
FA4419-11-Q-0102
Issued by
Department of the Air Force Air Education and Training Command

About this file

Questions and answers.

View the file

Other files for this federal contract opportunity

Other files attached to Altus AFB, Bldg 450 Roof Replacement, newest first.
File Type Posted
Atch 6 3052.xlsx XLSX spreadsheet
Amended Solicitation.pdf PDF
SOW-Revised date 1 Aug. 11.docx DOCX document
Bldg 450 Drawings.pdf PDF
Atch 4 Specs.pdf PDF
Bldg 450 Solicitation.pdf PDF
Atch 5 ECERT.pdf PDF
Atch 3 Drawings MFR.docx DOCX document
Atch 2 WD.docx DOCX document
Atch 1 SOW- 17 June 11.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 450 Roof Replacement: Questions The existing fascia, scuppers and gravel stop are galvanized steel, the plans call for aluminum at these locations, do you want the new material to be aluminum? NO The plans call to relocate (2) light fixtures below the fascia, these fixtures are already below the fascia; what do you want us to do with these fixtures? Nothing The SOW calls for ¼” / 12” tapered insulation on the entire roof, the existing roof has a ¾” / 12” slope built into the structure; do you want the additional tapered insulation on this roof? The tapered insulation is needed to form the crickets to divert the water flow toward the scuppers. No additional taper.

Is it your intent that all wood blocking anchored to CMU, wood blocking attached to CMU blocking and all fascia boards are to be replaced? If so, do you want pressure treated wood at these locations? If it needs to be replaced, Replace with pressure treated wood The existing parapet flashing is a surface mounted flashing attached with masonry anchors; your detail shows this flashing cut into the mortar joint, do you want the new flashing cut into the mortar joint? Go back with surface mounted.