Attachment_2_-_Drawings.pdf

PDF 2 MB Posted

Attached to
Replace Exterior Street & Parking Lighting Federal contract opportunity
Solicitation number
FA4417-15-R-0018
Issued by
Department of the Air Force Special Operations Command

About this file

Attachment 2 - Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Replace Exterior Street & Parking Lighting, newest first.
File Type Posted
Questions-Clarifications.docx DOCX document
FA4417-15-R-0018_Amendment_01.pdf PDF
FA4417-15-R-0019_Amendment_01.pdf PDF
Drawing_Sheet_E-28.pdf PDF
TAB_-_16_Questions_and_Answers.pdf PDF
East_side.pptx PPTX presentation
Site_Visit_Sign-in.pdf PDF
Pre-Proposal_Site_Visit_Memo_0018.doc DOC document
Attachment_5_-_Financial_Questionnaire.docx DOCX document
Attachment_3_-_Schedule_of_Wage_Rates_Building.pdf PDF
FA4417-15-R-0018.pdf PDF
Attachment_4_-_Past_Performance_Questionnaire.docx DOCX document
Attachment_1_-_Specifications.pdf PDF
Show all 13

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 29

T-1

I N

D E

X

O

F

D

R A

W I N

G S

P

R O

J E

C T

L O

C A

T I O

N

M

A P

REPLACE EXTERIOR

STREET/PARKING LIGHTING

HURLBURT FIELD, FLORIDA

In d e p e n d e n c e

R o a d

US98

C o d y

A v e n u e

I n d e p e n d e n c e o a d

K e r w o o d

R o a d

Lielmanis Avenue

H o w i e

W a l t e r s y

91363

90838

W a l k u p y

AREA OF WORK

PROJECT LOCATION MAP

NO SCALE

INDEX OF DRAWINGS

SHEET NUMBER SHEET TITLE

T-1 INDEX OF DRAWINGS & PROJECT LOCATION MAP

E-1 ELECTRICAL SITE PLAN - BUILDING 91000

E-2 ELECTRICAL SITE PLAN - BUILDING 91009

E-3 ELECTRICAL SITE PLAN - BUILDING 91016

E-4 ELECTRICAL SITE PLAN - BUILDING 91020

E-5 ELECTRICAL SITE PLAN - BUILDING 91021

E-6 ELECTRICAL SITE PLAN - BUILDING 91024

E-7 ELECTRICAL SITE PLAN - BUILDING 91025

E-8 ELECTRICAL SITE PLAN - BUILDING 91029

E-9 ELECTRICAL SITE PLAN - BUILDING 91031

E-10 ELECTRICAL SITE PLAN - BUILDING 91033

E-11 ELECTRICAL SITE PLAN - BUILDING 91036

E-12 ELECTRICAL SITE PLAN - BUILDING 91037

E-13 ELECTRICAL SITE PLAN - BUILDING 91042

E-14 ELECTRICAL SITE PLAN - BUILDING 91045

E-15 ELECTRICAL SITE PLAN - BUILDING 91048

E-16 ELECTRICAL SITE PLAN - BUILDING 91055

E-17 ELECTRICAL SITE PLAN - BUILDING 91101

E-18 ELECTRICAL SITE PLAN - BUILDING 91151

E-19 ELECTRICAL SITE PLAN - BUILDING 91252

E-20 ELECTRICAL SITE PLAN - BUILDING 91255

E-21 ELECTRICAL SITE PLAN - BUILDING 91258

E-22 ELECTRICAL SITE PLAN - BUILDING 91259

E-23 ELECTRICAL SITE PLAN - BUILDING 91266

E-24 ELECTRICAL SITE PLAN - JOGGING PATH - AREA 1

E-25 ELECTRICAL SITE PLAN - JOGGING PATH - AREA 2

E-26 ELECTRICAL SITE PLAN - JOGGING PATH - AREA 3

E-27 ELECTRICAL SITE PLAN - LIFT STATION

E-28 LIGHTING FIXTURE SCHEDULE & DETAILS

MAIN GATE

HAUL ROUTE

CONTRACTOR'S

LAY DOWN YARD

SCALE: 1" = 10'-0"

ELECTRICAL SITE PLAN - BUILDING 91000

91000

EXTERIOR ELECTRICAL LEGEND:

REMOVE EXISTING H.I.D. LUMINAIRE & INSTALL LED LUMINAIRE ON EXISTING ALUMINUM POLE.

REMOVE EXISTING H.I.D. LUMINAIRES & INSTALL LED LUMINAIRES ON EXISTING ALUMINUM POLE.

REMOVE EXISTING H.I.D. FLOODLIGHT & INSTALL LED FLOODLIGHT ON EXISTING ALUMINUM POLE.

REMOVE EXISTING H.I.D. FLOODLIGHTS & INSTALL LED FLOODLIGHTS ON EXISTING ALUMINUM POLE.

REMOVE EXISTING H.I.D. LUMINAIRE & EXISTING ALUMINUM POLE.

LL

LL

NOTE:

ADJUST EXISTING TIME SWITCH CONTROLLER TO TURN

EXTERIOR LIGHTING ON AT DUSK AND OFF AT 8:00 PM. INSTALL

"ALWAYS ON" SHORTING CAP ON LIGHTING FIXTURES.

E-1

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91009

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91009

DD

DD

DD

DD

DD DD

DD

DD

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK AND OFF AT DAWN. REMOVE EXISTING

BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING CAP.

E-2

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

ELECTRICAL SITE PLAN - BUILDING 91016

91016

JJ

JJ

JJ

JJ

JJ

JJ

JJ

KK

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK AND OFF AT 8:00 PM. REMOVE EXISTING

BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING

CAP.

E-3

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91020

SCALE: 1" = 30'-0"

ELECTRICAL SITE PLAN - BUILDING 91020

LIELMANIS AVENUE

91041

I

N

D

E

P

E

N

D

E

N

E

A

D

B

B

B

B

B

B

B

C

C

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND OFF

AT DAWN, UNLESS NOTED OTHERWISE. REMOVE EXISTING

BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING CAP.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO TURN

LIGHT ON AT DUSK AND OFF AT DAWN.

E-4

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91021

ELECTRICAL SITE PLAN - BUILDING 91021

H

O

W

I

A

L

T

E

Y

CC

NOTE:

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN

LIGHT ON AT DUSK AND OFF AT 8:00 PM.

E-5

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91024

ELECTRICAL SITE PLAN - BUILDING 91024

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND

OFF AT DAWN.

E-6

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91025

ELECTRICAL SITE PLAN - BUILDING 91025

OO

OO

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND

OFF AT DAWN. REMOVE EXISTING BUILDING MOUNTED

PHOTO-CELL & INSTALL A SHORTING CAP.

E-7

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91028

91029

91037

91035

SCALE: 1" = 30'-0"

ELECTRICAL SITE PLAN - BUILDING 91029

91030

91039

91027

91260

91265

91254

91263

91264

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

X

X

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK, OFF AT

10:00 PM, ON AT 5:00 AM AND OFF AT DAWN, UNLESS NOTED OTHERWISE. REMOVE

EXISTING BUILDING MOUNTED PHOTO-CELLS & INSTALL SHORTING CAPS ON EACH

BUILDING THAT SERVES EXTERIOR LIGHTING FIXTURES.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO

TURN LIGHT ON AT DUSK AND OFF AT DAWN.

E-8

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91031

91037

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91031

91032

91034

V

V

V

W

W

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:00 AM AND

E-9

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91033

ELECTRICAL SITE PLAN - BUILDING 91033

91032

91034

91038

99013

99015

99017

99019

U

U

U

U

U

U U

U

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

E-10

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91036

ELECTRICAL SITE PLAN - BUILDING 91036

99019

99017

91154

T

T

T

T

T

T

T

T

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:00 AM AND

E-11

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91031

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91037

91034

S

S

S

S

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:00 AM AND

E-12

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

ELECTRICAL SITE PLAN - BUILDING 91042

91049

91050

91042

91041

E

E

E

G

G

G

G

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK,

OFF AT 8:00 PM, ON AT 5:00 AM AND OFF AT DAWN. REMOVE EXISTING

BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING CAP.

E-13

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91045

91047

91048

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91045

91057

99958

91058

91052

K E

R W

O O

D

R

O A

D

AA

AA

AA

AA

AA

BB

BB

MM

MM

MM

MM

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK,

OFF AT 8:00 PM, ON AT 5:00 AM AND OFF AT DAWN, UNLESS NOTED OTHERWISE.

REMOVE EXISTING BUILDING MOUNTED PHOTO-CELLS & INSTALL SHORTING

CAPS ON EACH BUILDING THAT SERVES EXTERIOR LIGHTING FIXTURES.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN THIS

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN THIS

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN THIS

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN THIS

LIGHT ON AT DUSK AND OFF AT DAWN.

E-14

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91048

ELECTRICAL SITE PLAN - BUILDING 91048

J

J

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT

DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND OFF AT DAWN. REMOVE

EXISTING BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING CAP.

E-15

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91055

91054

91053

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91055

91050

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

TT

EE

EE

EE

EE

EE

EE

EE

EE

EE

EE

FF

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK

AND OFF AT DAWN. REMOVE EXISTING BUILDING MOUNTED PHOTO-CELL &

INSTALL A SHORTING CAP. RECONFIGURE EXISTING TIME SWITCH TO ALLOW

LIGHTS TO BURN ALL NIGHT.

E-16

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

ELECTRICAL SITE PLAN - BUILDING 91101

91099

91103

91101

91112

91113

91104

ZZ

ZZ

ZZ

ZZ

ZZ

ZZ

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

E-17

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

ELECTRICAL SITE PLAN - BUILDING 91151

91151

91149

91146

91152

91113

YY

YY

YY

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

E-18

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91252

91255

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91252

91260

91254

91263

91264

91257

Q

Q

R

Q

R

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND

E-19

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91255

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91255

91250

O O

O

O

II

P

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 5:30 AM AND

OFF AT DAWN. REMOVE EXISTING BUILDING MOUNTED

PHOTO-CELL & INSTALL A SHORTING CAP. EXISTING

LIGHTING IS SERVED FROM BUILDING 91252.

E-20

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91258

91266

SCALE: 1" = 20'-0"

ELECTRICAL SITE PLAN - BUILDING 91258

M

M

N

N

N

N

M

M

M

M

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK,

OFF AT 10:00 PM, ON AT 5:00 AM AND OFF AT DAWN, UNLESS NOTED

OTHERWISE. REMOVE EXISTING BUILDING MOUNTED PHOTO-CELL & INSTALL A

SHORTING CAP.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN LIGHT

ON AT DUSK AND OFF AT 1:00 AM.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN LIGHT

ON AT DUSK AND OFF AT 1:00 AM.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN LIGHT

ON AT DUSK AND OFF AT 1:00 AM.

ADJUST PHOTO-CELL ON LIGHTING FIXTURE TO TURN LIGHT

ON AT DUSK AND OFF AT 1:00 AM.

E-21

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91258

91259

91266

SCALE: 1" = 30'-0"

ELECTRICAL SITE PLAN - BUILDING 91259

91157

91153

91144

91268

91262

91261

J

J

J

I

I

J

J

J

J

J

K

II

I

I

I

I

I

I

I

I

I

I

I

HH

HH

HH

HH

HH

HH

HH

GG

K

GG

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN

LIGHTS ON AT DUSK, OFF AT 8:00 PM, ON AT 4:00 AM AND

OFF AT DAWN, UNLESS NOTED OTHERWISE. REMOVE

EXISTING BUILDING MOUNTED PHOTO-CELL & INSTALL A

SHORTING CAP.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO TURN

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO TURN

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE TO TURN

LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

E-22

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91252

91255

91258

91266

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN - BUILDING 91266

91268

91250

91257

D

D

D

D

D

D

D

F

H

H

H

H

H

H

REMOVE EXISTING LIGHTING FIXTURE, POLE

& CONCRETE FOUNDATION. REMOVE

EXISTING WIRING & ABANDON EXISTING

CONDUIT BELOW GRADE.

REMOVE EXISTING LIGHTING FIXTURE, POLE

& CONCRETE FOUNDATION. REMOVE

EXISTING WIRING & ABANDON EXISTING

CONDUIT BELOW GRADE.

REMOVE EXISTING LIGHTING FIXTURE, POLE

& CONCRETE FOUNDATION. REMOVE

EXISTING WIRING & ABANDON EXISTING

CONDUIT BELOW GRADE.

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURES TO TURN LIGHTS ON AT DUSK, OFF AT

8:00 PM, ON AT 4:00 AM AND OFF AT DAWN, UNLESS NOTED OTHERWISE. REMOVE

EXISTING BUILDING MOUNTED PHOTO-CELL & INSTALL A SHORTING CAP.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

ADJUST PHOTO-CELL ON THIS LIGHTING FIXTURE

TO TURN LIGHT ON AT DUSK AND OFF AT DAWN.

E-23

E L E

C T

R I C

A L

S

I T

E

P

L A

N

B

U I L D

I N

G

91363

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN - JOGGING PATH - AREA 1

91105

91107

91364

91350

W

A

L

K

U

P

Y

E-24

E L E

C T

R I C

A L

S

I T

E

P

L A

N

J O

G G

I N

G

P

A T

H

A

R E

91033

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN - JOGGING PATH - AREA 2

91032

91034

91099

I

N

D

E

P

E

N

D

E

N

A

D

91103

91105

91107

91114

91101

91112

91104

91113

91140

INSTALL NEW SENSUS METER ON

ALUMINUM PEDESTAL ADJACENT TO PAD

MOUNTED TRANSFORMER AS REQUIRED

TO METER EXISTING FEEDER SERVING

JOGGING PATH LIGHTS.

DETAIL - METER PEDESTAL

GRADE LEVEL MARKER.

9" X 4" X 1/8" # 5052 MARINE GRADE ALUMINUM PEDESTAL POST W/ PROTECTIVE COATING &

ALUMINUM CAP W/ (TWO) 2 TAMPER PROOF SET SCREWS (NON-CORROSIVE.)

ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL METER BASE.

METER WIRING AS REQUIRED BY METER. # 10 AWG THWN MINIMUM.

B

1" CHASE NIPPLE W/ BUSHING THROUGH BACK OF METER.

METER.

E

F

G

D

C

N.T.S.

A

BASE

CONCRETE

2'-0"

E

2'-0"

6"

A

F

G

A

6'-0"

SECTION

N.T.S.

A

F

G

A

E

D

C

B

B

1" PVC, SCH. 40 CONDUIT TO PAD MOUNT TRANSFORMER.

EXISTING PAD MOUNTED TRANSFORMER

MATCH LINE B

SINGLE LINE DIAGRAM

NO SCALE

EUS

M

EXISTING UNDERGROUND PRIMARY

KWH DEMAND METER & PEDESTAL.

EXISTING PAD MOUNTED TRANSFORMER

EUS

KWH DEMAND METER NOTE:

PROVIDE A COMBINATION KW-HR AND KW DEMAND METER. METER SHALL

INCLUDE WIRELESS TRANSCEIVER HARDWARE. THE METER & WIRELESS

TRANSCEIVER HARDWARE SHALL BE COMPATIBLE WITH SENSUS SYSTEM

CURRENTLY BEING UTILIZED BY HURLBURT FIELD.

METER WIRING IN 1" PVC, SCH. 40 CONDUIT

EXISTING UNDERGROUND SECONDARY

SERVING JOGGING PATH LIGHTING PANELBOARD

3 - 200:5

C.T.'S

EXISTING UNDERGROUND SECONDARY

SERVING BUILDING 91099

REMOVE EXISTING PHOTO-CELL & INSTALL

A SHORTING CAP AT EXISTING CONTACTOR.

E-25

E L E

C T

R I C

A L

S

I T

E

P

L A

N

J O

G G

I N

G

P

A T

H

A

R E

91020

91028

91029

91054

91053

91035

SCALE: 1" = 50'-0"

ELECTRICAL SITE PLAN - JOGGING PATH - AREA 3

91016

LIELMANIS AVENUE

91049

91050

91042

91041

99045

91041

91043

91027

91039

91030

MATCH LINE B

REMOVE EXISTING PHOTO-CELL & INSTALL A SHORTING CAP ON

EXISTING OUTDOOR ENCLOSURE.

E-26

E L E

C T

R I C

A L

S

I T

E

P

L A

N

J O

G G

I N

G

P

A T

H

A

R E

ELECTRICAL SITE PLAN - LIFT STATION

PP

NOTE:

ADJUST PHOTO-CELLS ON LIGHTING FIXTURE TO TURN LIGHT ON AT DUSK

AND OFF AT 8:00 PM.

E-27

E L E

C T

R I C

A L

S

I T

E

P

L A

N

L I F

T

S

T A

T I

N

LIGHTING FIXTURE SCHEDULE

LED QUANTITYMARK

A 40

WATTS POLE TENON

ROUND

BALLAST RATING

31 7/8" ±

22" ±

10 5/8" ±

4 3/4" ±

DETAIL - 40 & 60 LED AREA LIGHTS

36 5/8" ±

26 7/8" ±

10 5/8" ±

4 3/4" ±

DETAIL - 80 LED AREA LIGHT

42 7/8" ±

33 1/8" ±

10 5/8" ±

4 3/4" ±

DETAIL - 100 & 120 LED AREA LIGHTS

B 80 ROUND

C 40 ROUND

D 60 SQUARE

E 80 ROUND

F 80 SQUARE

G 80 ROUND

H 80 SQUARE

I 60

J 80 SQUARE

K 80 SQUARE

ROUND

ROUND

M 80

N 80

O 60

P 80

Q 100

R 100

S 80

T 80

U 60

525 mA

700 mA

525 mA

700 mA

VOLTAGE

V 60

W 60

X 60

Y 60

Z 80

AA 60

BB 60

CC 120

DD 80

EE 80

FF 80

GG 80

HH 80

II 60

JJ 80

KK 80

LL 80

MM 80

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

ROUND

ROUND

80 700 mA 188 ???

60 139 277

OO

PP

ROUND

SQUARE

SS 40

TT 80

ROUND80 188 208YY

DESCRIPTION

ROUND

ROUND

SQUARE

700 mA

700 mA

525 mA

525 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

700 mA

525 mA

700 mA

ROUND

ROUND

SQUARE

SQUARE

SQUARE

SQUARE

SQUARE

EXISTING

ROUND

ROUND

ROUND

ROUND

ROUND

SQUARE

SQUARE

ROUND

ROUND

EXISTING

TENON

ROUND

1 HOUSING SHALL BE ALL ALUMINUM CONSTRUCTION. DIE CAST ALUMINUM

MOUNTING ARM MOUNTS TO A 2" TENON. FIXTURE SHALL INCLUDE A LEVELING

BUBBLE. FIXTURE SHALL INCLUDE A PHOTO-CELL RECEPTACLE WITH A

PHOTO-CELL, UNLESS NOTED OTHERWISE IN LIGHTING FIXTURE SCHEDULE.

SEE "PHOTO-CELL NOTE," THIS SHEET. FIXTURE FINISHED WITH AN EPOXY

PRIMER AND A LIGHT BRONZE POWDER TOPCOAT, LIGHT ENGINE SHALL HAVE

A NATURAL ALUMINUM FINISH. FIXTURE SHALL BE UL LISTED FOR WET

LOCATIONS. FIXTURE SHALL HAVE AN EXTERIOR WATTAGE LABEL THAT

REFLECTS WATTS FOR THE DRIVE CURRENT SELECTED.

2 POWER DRIVER SHALL HAVE DRIVE CURRENT RATING AND VOLTAGE INPUT

CHARACTERISTICS AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE.

DRIVERS SHALL BE CLASS 1 WITH A POWER FACTOR GREATER THAN 90% AND

THD LESS THAN 20% AT FULL LOAD. DRIVER SHALL BE FURNISHED WITH A

QUICK DISCONNECT HARNESS, AND AN INTEGRAL 10 KV SURGE PROTECTIVE

DEVICE. SURGE PROTECTIVE DEVICE SHALL MEET THE REQUIREMENTS OF

IEEE/ANSI C62.41.2.

3 LIGHT ENGINE WITH NATURAL ALUMINUM FINISH. PROVIDE LIGHT ENGINE WITH

THE NUMBER OF LED LAMPS AS INDICATED IN THE LIGHTING FIXTURE

SCHEDULE. COLOR TEMPERATURE OF LED LAMPS SHALL BE 4300 K.

1 2

DETAIL - LED AREA LIGHT

N.T.S.

N.T.S.

N.T.S.

N.T.S.

PHOTO-CELL NOTE:

PHOTO-CELLS SHALL HAVE INTEGRAL TIMERS WHICH TURN THE LIGHTS OFF

AND ON AT A PREDETERMINED TIME. PHOTO-CELLS SHALL BRING THE

FIXTURES ON AT DUSK, TURN FIXTURES OFF UP TO 4 HOURS BEFORE

MIDNIGHT, TURN THE FIXTURES BACK ON FROM 2 TO 10 HOURS AFTER

MIDNIGHT, AND TURN THE FIXTURES OFF AT DAWN.

TENON

EXISTING

TENON

EXISTING

TENON

EXISTING

TENON

LIGHTING FIXTURE SCHEDULE

LED QUANTITYMARK WATTS POLE TENONBALLAST RATING VOLTAGE DESCRIPTION

SQUARE60 139 120ZZ 700 mA

ROUND80 188 277700 mAQQ

EXISTING

TENON

DETAIL - POLE MOUNTING ADAPTERS

N.T.S.

DETAIL - ROUND POLE ADAPTER

N.T.S.

DETAIL - SQUARE POLE ADAPTER

N.T.S.

ADJUSTABLE ARM FOR MOUNTING TO 2 3/8" O.D. TENON

ADJUSTABLE ARM FOR MOUNTING TO 2 3/8" O.D. TENON

ADJUSTABLE ARM FOR MOUNTING TO 2 3/8" O.D. TENON

MOUNT ADAPTER OVER EXISTING ROUND POLE OR

EXISTING TENON. VERIFY EXACT DIAMETER OF

EXISTING POLE PRIOR TO ORDERING ADAPTER.

MOUNT ADAPTER INSIDE EXISTING SQUARE

POLE. VERIFY EXACT DIMENSIONS OF EXISTING

POLE PRIOR TO ORDERING ADAPTER.

2 3/8" O.D. TENON

ROUND POLE ADAPTER (TYP.)

SQUARE POLE ADAPTER (TYP.)

FIXTURE MOUNTING TENON (TYP.)

2 3/8" O.D. TENON

FIXTURE MOUNTING TENON (TYP.)

INSTALL ONE STAINLESS STEEL BOLT THRU

EXISTING POLE TO ELIMINATE ROTATION OF

ADAPTER. FASTEN WITH STAINLESS STEEL NUT

& WASHERS. INSTALL ADDITIONAL BOLTS AS

REQUIRED BY TENON MOUNTING

CONFIGURATION.

INSTALL ONE STAINLESS STEEL BOLT THRU

EXISTING POLE TO ELIMINATE ROTATION OF

ADAPTER. FASTEN WITH STAINLESS STEEL NUT

& WASHERS. INSTALL ADDITIONAL BOLTS AS

REQUIRED BY TENON MOUNTING

CONFIGURATION.

AREA LIGHT W/ TYPE II DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION. AIM FIXTURE AT 45°

ABOVE HORIZONTAL.

2 AREA LIGHTS W/ TYPE IV DISTRIBUTION. AIM FIXTURES AT

30° ABOVE HORIZONTAL.

AREA LIGHT W/ TYPE IV DISTRIBUTION. AIM FIXTURE AT 30°

ABOVE HORIZONTAL.

AREA LIGHT W/ TYPE III DISTRIBUTION. AIM FIXTURE AT 30°

ABOVE HORIZONTAL.

2 AREA LIGHTS AT 180° W/ TYPE III DISTRIBUTION. AIM

FIXTURE AT 30° ABOVE HORIZONTAL.

2 AREA LIGHTS AT 90° W/ TYPE III DISTRIBUTION. AIM ONE

FIXTURE AT 30° ABOVE HORIZONTAL.

BASIS OF DESIGN:

AREA LIGHT W/ TYPE II DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE II DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE II DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE III DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

2 AREA LIGHTS AT 180° W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION. INSTALL "ALWAYS ON"

SHORTING CAP ON FIXTURE IN LIEU OF PHOTOCELL.

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

AREA LIGHT W/ TYPE IV DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTION

POST TOP LUMINAIRE W/ TYPE V DISTRIBUTION

AREA LIGHT W/ TYPE III DISTRIBUTIONAREA LIGHT W/ TYPE IV DISTRIBUTION

LIGHTING FIXTURES ON THIS PROJECT HAVE BEEN DESIGNED

AROUND BETALED (CREE) LIGHTING, "LEDWAY" FIXTURES.

PHOTO-CELLS ARE DESIGNED AROUND INTERMATIC OR RIPLEY

LIGHTING CONTROL PRODUCTS.

E-28

L I G

H T

I N

G

F

I X

T U

H

E D

U

D