Attachment 3 - DWG_ MAHG131002_ 29 July 2020.pdf
PDF 7 MB Posted
- Attached to
- Maintain Exterior Coatings of Various Facilities Federal contract opportunity
- Solicitation number
- FA301020R0032
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1 - SOW_ MAHG131002_ 30 July 2020.pdf | ||
| Solicitation Amendment FA301020R00320003 SF 30.pdf | ||
| Attachment 2 - SPECS_ MAHG131002_ 29 July 2020.pdf | ||
| Solicitation Amendment FA301020R00320002 SF 30.pdf | ||
| Sign_in_14 July 2020.pdf | ||
| Solicitation Amendment FA301020R00320001 SF 30.pdf | ||
| Attachment 7 - Past Performance Questionnaire.doc | DOC document | |
| Attachment 8 - Past Performance Reference List (SAP).docx | DOCX document | |
| Solicitation - FA301020R0032.pdf | ||
| Attachment 4 - AF 66_ 22 May 2020.xlsx | XLSX spreadsheet | |
| Attachment 1 - SOW_ MAHG131002_ 22 May 2020.pdf | ||
| Attachment 9 - SF 1444.pdf | ||
| Attachment 5 - Notice of Compliance.pdf | ||
| Attachment 2 - SPECS_ MAHG131002_ 20 May 2020.pdf | ||
| Attachment 6 - WD MS20200050.pdf | ||
| Attachment 3 - DWG_ MAHG131002_ 5 Nov 2019.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8
KEESLER AFB, MISSISSIPPI
MAINTAIN EXTERIOR COATING SYSTEMS
I
., __ ...,u ;al ti.� 4 :WATER) ,�, ii ,,11: _:
JACKSON
.G··.·.·.·.·.·.·.·.·.·.·.·-·.·.·.·.·.·.·.·.·.·.·.·.· .
. ·•·• ULFPORT
. . . . . . . . . . . . . . ' ' . . . . . . . . . . . . . . lliil�IIITT\ �I � �
GULFPORT 4 BILOXI /
:t BILOXI, MS
VICINITY MAP
LOCATION PLAN
KEESLER AFB, MS
SCALE: NONE
INDEX OF DRAWINGS
T1 .0 TITLE SHEET
A1.0 4332 -WEATHER BUILDING - KEY PLAN, ELEVATIONS, NOTES, PHOTOS
A1.1 1203-GAUDE LANE-KEYPLAN, ELEVATIONS, NOTES
A1.2 4434- STORAGE BLDG AT TRANSPORTATION- KEYPLAN, ELEVATIONS, NOTES
A 1.3 4330 - WOLFE HALL - ELEVATIONS, NOTES, PHOTOS
A 1.4 4331 - ALLEE HALL - ELEVATIONS, NOTES, PHOTOS
A 1.5 4605 -CONTRACTING
1 2
AFF
BLDG
CONC.
CONT.
E
EIFS
EJT
EL
ENTR
EQ
EXIST
EXT
FBR
FIN
FL
FT
GAL
GEN
GR
ABOVE FINISH FLOOR
BUILDING
CONCRETE
CONTINUOUS
EXISTING
ABBREVIATIONS
EXTERIOR INSULATION & FINISH SYSTEM
EXPANSION JOINT
ELEVATIONS
ENTRANCE
EQUAL
EXISTING
EXTERIOR
FACE BRICK
FINISH
FLOOR
FOOT/FEET
GALLONS
GENERAL
GRADE
__ -e
H
HC
HT
INSUL
JT
LT
LTG
LVR
MATL
MET
MIN.
MO
NA
NIC
oc
PNT
TYP
W/
4332 - WEATHER BUILDING
1203 - GAUDE LANE
4434 - STORAGE BUILDING
4330 - WOLFE HALL
4331 - ALLEE HALL
4605 - CONTRACTING
HEIGHT
HANDICAP
HEIGHT
INSULATION
JOINT
LIGHT
LIGHTING
LOUVER
MATERIAL
METAL
MINIMUM
MASONRY OPENING
NOT APPLICABLE
NOT IN CONTRACT
ON CENTER
PAINTED
TYPICAL
WITH
MATERIAL LEGEND
I ·<i,:· ··"· '� :-d :I : 4.. . 1
11111111111 tAArul
CONCRETE
CONCRETE
MASONRY UNIT
BRICK
EXTERIOR INSULATION
AND FINISH SYSTEM
(EIFS)
ARCHITECTURAL SYMBOLS
'B KEY NOTES
ROOM NUMBERS
9 10
Re'IISION I t:¥irt: PRAWN I - 1.Nrrl:P STATES AIF!. � M<. EP!.t'.ATION ,tt,i;, TRAINlll8 UM.4AW
KEESLER AIR FORCE BASE
ff� tF C.IVIL ENE>ll'l:l:R5
M �� lNlu �� lNl ��u � [Pi1 � (Q) [Pi1
�(Q)� u�lNl� �w�1�U01J
G
F
E
D
C
B
BUILDINGS - 4332, 1203, 4434, 4330, 4331, 4605 A
,a,f.MITTfP: �: r">a..ITY t,I.Ml:IER:
(C,hiet of C.ontrach V"11ign) (C,hief of Engineering) 4332, 1203, 4434, 4434, A.MARASCA G.REED 4331, 4605
DRA'MNl!:IMJ-,CER:
T1 .0 -TITLE SHEET �;.y II �d II �IES �;ley- II 29 JULY 202011 =�=02 """'" 1 .,. 7
9 10
D
C
B
A
I
1 2 3
PROJECT SITE
0;04_J 0 C __.--' , DDD
CJ CJ CJ
J
D oD "'-'-'--1 ���,L_C____ _ ___J
��.rt� 0 ti '11�� 1�
PAINT CAST IRON BOOT
(ONLY) AT DOWNSPOUT
(MEDIUM BRONZE); CLEAN
ALUMINUM GUTTERS AND
DOWNSPOUTS ONLY, NO
PAINT.
CLEAN EXTERIOR
LOUVERS, AND
LIGHTING FIXTURES
(FIXTURE & LENS).
REMOVE FIXTURE
TO CLEAN ONLY
AS NECESS
:¼PAINT ,
BOLLARDS,
SAFETY
YELLOW
PAINT SNACK
AREA SHED,
COLOR TO MATCH
EXISTING, OR EQ.
- SEE PROVIDE &
INSTALL NOTE.
10·-o·
1 KEYPLAN - EXISTING
CLEAN EXTERIOR
BLDG. SURFACE
REMOVE MOLD, DIRT, MILDEW AND/OR
ALGAE FROM BLDG. EXTERIOR SURFACES
- ALL WALLS, RUBBED CONCRETE,
WINDOWS, DOORS, LOUVERS, LIGHTS,
SIGNS/LETTERS, EXITS, SIDEWALKS, STEPS
& ROOF, TO INCLUDE OBSERVATION DECK.
EXISTING�CONCRETE STEPS ,
121'-4"
A1 .0 SCALE: 1/16"=1'-0"
1 2 3
LAJ
[Yl
24'-10"
REMOVE RUST FROM
OVERHANGS AND/OR OTHER
METAL SURFACES - WINDOWS
AND DOOR FRAMES
CLEAN LIGHT
FIXTURES AT
ENTRANCES
83,685 SF -
C
TOTAL
5 6
PRIOR TO PRESSURE
WASHING, REMOVE &
REPAIR CRACKED
I DETERIORATED SEAL AT
� CONCRETE SIDEWALK
�=====�=�5'
WHERE BRICK WALL
Ir MEETS PAVEMENT AT
DOOR OPENING AT EAST
AND WEST ENTRANCES
AND PREP FOR REPAIR.
ESTIMATED BLDG
HEIGHT: 27'-8"
PRIOR TO PRESSURE WASHING,
REMOVE & REPAIR CRACKED
DETERIORATED CONCRETE
PANEL JOINT SEALANT AT
RIGHT CORNER OF SOUTH
ENTRANCE WALL.
121'-4"
*CONTRACTOR TO FIELD VERIFY
ALL DIMENSIONS AND CONDITIONS.*
5 6
1 o·-o·
CLEAN WINDOWS,
DOORS, AND DOOR
FRAMES AFTER RUST
AND GRIME REMOVAL
r-
LO
r<)
A 1.0
55'-211
OBSERVATION DECK - 3RD FL
SCALE: 1/16"=1'-0"
CLEAN EXTERIOR BUILDING
SURFACE (THIRD FL);
STOREFRONT WITH PANELS,
ABOVE & BELOW.
9 1 0
GENBW.NOlES
1. IT IS RECOMMENDED THAT THE CONTRACTOR FIELD VERIFY ALL
EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF G
CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS
THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS
DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION
DEBRIS DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND
BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR
SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED
STATE, AS APPROVED BY THE CONTRACTING OFFICER.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,
SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE
CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,
ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR
TO WORK.
CONSTRUC110N N01ES
PROVIDE SERVICES TO CLEAN, REPAINT /REPAIR ALL EXTERIOR
SURFACES FOR BUILDING 4332.
F
REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE E BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS, WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, RAMPS, EXITS, SIDEWALKS, INCLUDING
SCREEN WALLS AT SMOKING AND TRASH COMPARTMENT.
CLEAN EXTERIOR BUILDING SURFACE (THIRD FLOOR); STOREFRONT WITH
PANELS, ABOVE AND BELOW.
CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO
CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.
REMOVE RUST AND GRIME FROM OVERHANGS AND OTHER METAL
SURFACES.
CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME
REMOVAL.
RESTORE/REPAIR PRECAST CONCRETE PANELS, USE COLOR-MATCHED
EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, INCLUDING
CONSTRUCTION AND EXPANSION JOINTS; COLOR TO MATCH EXISTING.
REPAIR SMALL CRACKS AND VOIDS IN CONCRETE (BLDG. SKIRT), AS
NECESSARY. USE ULTRA SPEC MASONRY ELASTOMERIC WATERPROOF
COATING LOW LUSTRE (360), OR EQUAL.
CLEAN EXTERIOR LOUVERS.
PRIOR TO PRESSURE WASHING, REPAIR SEAL AT CONCRETE SIDEWALK
WIHERE BRICK WALL MEETS PAVEMENT AT DOOR OPENING AT THE EAST
AND WEST ENTRANCES.
PRIOR TO PRESSURE WASHING, REPAIR PANEL JOINT SEALANT AT
RIGHT CORNER OF SOUTH ENTRANCE WALL. USE COLOR-MATCHED
EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, AS NEEDED; COLOR
TO MATCH EXISTING (CREAM), OR EQUAL).
PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,
DETERIORATED SEALANT AT WINDOWS, DOORS AND PANEL JOINTS AS
NECESSARY.
PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY, CHEMICALS
D
AND DETERGENTS ARE NOT ALLOWED. USE CARE TO PREVENT DAMAGE,
COR FURTHER DAMAGE FROM OCCURRING.
ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL
SPRAYED/CLEANED, ACCORDING TO INDUSTRY SIDS .
PAINT HM DOOR AND FRAMES, COLOR TO MATCH EXISTING.
PAINT BOLLARDS AT ROLLUP DOOR; PAINT COLOR: SAFETY YELLOW.
PAINT SNACK AREA SHED, COLOR TO MATCH EXISTING, OR EQUAL.
PAINT CAST IRON BOOTS AT DOWNSPOUT (MEDIUM BRONZE); CLEAN
ALUMINUM GUTTERS AND DOWNSPOUTS ONLY, NO PAINT.
Rat15k:iN PAre
AR 1$1X,ATJON ..¥P TRANINE:i at..fMW
KEESLER AIR FORCE BASE
O'FIC.f. OF c;.ML ENE:i11ti:R$ rM® □[l'i)�® □[l'i) �bK�®[f' □@[l' (C:@®�□[l'i]@ �w��®ITilil W@®it[h]@[l' ��@!� ., ����
SllMITTED:
(c.hief of '-ontracts Pesign)
A. MARASCA
DE51E'll\6r. aE!,KED;
L. ASHLEY G. REED
(c.hiel of Engineering)
G.REED"""'
VARIES -
L.ASHLEY
PATE: f'l¼E(.T �:
29 JULY 2020 MAHG 13-1002
Bldg. 4332 - Weather Building [;RAWNE';I N.MrlER::
A1.0
� 2 a- 7
1 0
B
A
1557824398E Text Box
1557824398E Text Box
E
D
C
B
A
1 2
D
PRECAST
ELS;SEAL
PROcE&T SITE
HST
IT TIIT
REMOVE MOLD, DIRT, MILDEW AND/OR ALGAE
FROM BLDG EXT SURFACES AND MORTAR
JOINTS (WITHOUT DAMAGE TO BRICKWORK) -
ALL WALLS, RUBBED CONCRETE, WINDOWS, -
DOORS, LOUVERS, LIGHTS, SIGNS, RAMPS,
EXITS, SIDEWALKS, & ROOF, INCLUDING SCREEN
WALLS, AND TRASH PAD SCREEN WALLS
C.
J.I i-
RESTORE
CONCRETE PAN
CRACKS A
INCLUDING C
EXPANSION JOIN
PROVIDE & INST
ND CHIPS!
ONSTR. &
TS - SEE
ALL NOTE
CLEAN EXTERIOR
BLDG SURF ACE
'o I ""'
12·-o"
L/STEEL
FRAME
OLOR TO
PAINT DOOR
(HOLLOW META
ONLY), C
MATCH EXIS
EQUAL - SEE
& INSTA
TING, OR
PROVIDE
LL NOTE
1 KEYPLAN - EXISTING
A 1.1 SCALE: 1 /16"=1 '-0"
REMOVE DIRT FROM LIGHT
FIXTURES (FIXTURES AND
LENS), REMOVE FIXTURE (TO
CLEAN) ONLY AS NECESSARY
l
REMOVE RUST AND GRIME
FROM OVERHANGS AND/OR
OTHER METAL SURFACES -
WINDOWS, DOOR FRAMES,
ETC.
CLEAN EXTERIOR
LOUVERS LIGHT
. :7
FIXTURES & BLDG
EXTERIOR SURFACES
I 0
I
;==I
RESTORE SMALL CRACKS
AND VOIDS IN CONCRETE
(BLDG. SKIRT), AND
ROUGH MASONRY AS
NECESSARY
1 1 1
I l I�
30'-6"
22,004 SF - TOTAL i---:i \ \ \
0 ESTIMATED BUILDING � I
HEIGHT - 19'-0"
I
J LIU I ULJI - ■ ■ ■ ■
Jl ■ r nn g ■
■ _e f- ■ J=
■ - � � [l�
I ■ - F ■ [l f- -
■ [I ■ -
= II ■ -i
• t:I• ! • h I I c:::::r-7 " --
I ]
140'-o" 44'-o"
3 4
CL
*N
I
<I]
I --"'- I
<I]
I
EAN EXTERIOR BLDG SURF ACES;
ON-ADJACENT WALLS INCLUDED
7 8
7 8
9 1 0
GENBW.NOlES
1. IT IS RECOMMENDED 11-IAT TI-IE CONTRACTOR FIELD VERIFY ALL
EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF
G CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS
11-IAT COULD AFFECT TI-IE SUCCESSFUL COMPLETION OF TI-IE WORK AS
DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND 011-IER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION
DEBRIS DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND
BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR
SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED
STA TE, AS APPROVED BY TI-IE CONTRACTING OFFICER.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN TI-IE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM TI-IE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF THERE ARE DIFFERING CONDITIONS IN TI-IE FIELD FROM TI-IE SOW,
SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT TI-IE
CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING Will-I ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,
ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR
TO WORK.
CONSTRUC110N M.> i ES
PROVIDE SERVICES TO CLEAN, REPAINT/REPAIR ALL EXTERIOR
SURFACES FOR BUILDING 1203.
REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM TI-IE
BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,
WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM,
SIGNAGE, DOOR LANDINGS, RAMPS, EXITS, SIDEWALKS, INCLUDING
SCREEN WALLS, AND TRASH PAD SCREEN WALLS.
CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO
CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.
REMOVE RUST AND GRIME FROM OVERHANGS AND 011-IER METAL
SURFACES.
PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,
DETERIORATED SEALANT AT WINDOWS, DOORS AND PANEL JOINTS AS
NECESSARY.
PRESSURE WASH Will-I WATER ONLY, CHEMICALS AND DETERGENTS ARE
NOT ALLOWED. USE CARE TO PREVENT DAMAGE, OR FURTI-IER DAMAGE
FROM OCCURRING.
ENSURE TI-IE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL
SPRAYED/CLEANED, ACCORDING TO INDUSTRY SIDS.
CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME
REMOVAL.
PAINT HM DOOR AND FRAMES, COLOR TO MATCH EXISTING.
RESTORE/REPAIR PRECAST CONCRETE PANELS, USE COLOR-MATCHED
EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, INCLUDING
CONSTRUCTION AND EXPANSION JOINTS; COLOR TO MATCH EXISTING.
REPAIR SMALL CRACKS AND VOIDS IN CONCRETE (BLDG. SKIRT), CMU,
AND ROUGH MASONRY (BRICK), AS NECESSARY. USE ULTRA SPEC
MASONRY ELASTOMERIC WATERPROOF COATING LOW LUSTRE (360), OR
EQUAL.
CLEAN EXTERIOR LOUVERS.
Rat15k:iN PAre
AR 1$1X,ATJON ..¥P TRANINE:i at..fMW
KEESLER AIR FORCE BASE
O'FIC.f. OF c;.ML ENE:illti:R$
U¥ll@ □ITTlU@□ITTl ��U®IT'□@IT' �@@UDITTl@ �W�U®M
@®lYl©I® IL®ITTl@ "" i �@� SllMITTED:
(c.hief of '-ontracts Pesign)
A. MARASCA
DE51E'll\6r. aE!,KED;
L. ASHLEY G. REED
(c.hiel of Engineering)
G.REED
VARIES -
L.ASHLEY
PATE: f'l¼E(.T �:
29 JULY 2020 MAHG 13-1002
Bldg. 1203 - GAU DE LANE [;RAWNE';I N.MrlER::
A1.1
� 3 a- 7
1 0
F
E
D
C
B
A
1557824398E Text Box
D
C
B
A
1 2
PROJECT SITE ---
I in I")
REPLACE CHIPPED
MISSING
CRACKED
BRICK AT SW END OF BLDG.; BRICK
COLOR TO MATCH EXISTING OR
EQUAL. SEE PROVIDE & INSTALL
NOTE
3,333 SF - TOTAL
ESTIMATED BUILDING
HEIGHT - 13'-3"
DOOR 1
C
' •I
PAINT DOOR
EXT-�1 --1:;;--x RECAULK AROUND EXTERIOR
SIDE) AND WINDOW
TRIM; COLOR TO
MATCH MEDIUM
BRONZE OR EQUAL
DOOR
OFFICE) AND WINDOW;
CLEAN BOTH SIDES OF WINDOW
& DOOR AFTER RUST & GRIME
REMOVAL
w
93' -3"
DOOR 2 DOOR 3
\_CLEAN EXTERIOR
BLDG SURFACE
AREAS, SIDEWALKS
INCLUDED
1 KEYPLAN - EXISTING
S�N NORTH
A 1.2 SCALE: 3/16" =1'-0" E
1 2 3
DOOR 4
\_PAINT CONCRETE)
BOLLARDS, AT
ROLL-UP DOORS;
PAINT COLOR:
SAFETY YELLOW
DOOR 5
DOOR 6
rREMOVE RUST AND
GRIME FROM OVERHANGS
AND
OR OTHER METAL
SURFACES - WINDOW,
DOOR FRAMES, ETC.
PAINT METAL PANEL
ABOVE BRICK; SEE
PROVIDE AND INSTALL
NOTE
rPRIOR TO PRESSURE
WASHING, USE
COLOR-MATCHED
EXTERIOR SEALANT TO
SEAL CRACKS AND CHIPS,
ONLY AS NECESSARY
MATCH EXISTING
CREAM),
OR EQUAL.
rREMOVE DIRT FROM
LIGHT FIXTURES
FIXTURE & LENS).
REMOVE FIXTURE
TO
CLEAN) ONLY AS
NECESSARY.
�REMOVE MOLD, DIRT, MILDEW AND
OR ALGAE
FROM BUILDING EXTERIOR SURFACES AND MORTAR
JOINTS
WITHOUT DAMAGE TO BRICKWORK) -ALL
WALLS
METAL PANEL AND BRICK), WINDOW,
DOOR, ROLL-UP METAL DOORS, AIR CONDITIONER,
LIGHTS, SIGNS, ROOF, CARWASH VACUUM STATION,
AND SIDEWALKS
6 7
9 1 0
GENBW.NOlES
1. IT IS RECOMMENDED lHAT lHE CONTRACTOR FIELD VERIFY ALL
EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF
G CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS
lHAT COULD AFFECT lHE SUCCESSFUL COMPLETION OF lHE WORK AS
DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OlHER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION
DEBRIS DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND
BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR
SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED
STATE, AS APPROVED BY lHE CONTRACTING OFFICER.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN lHE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM lHE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF lHERE ARE DIFFERING CONDITIONS IN lHE FIELD FROM lHE SOW, SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT lHE CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING �lH ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,
ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR
TO WORK.
CONS1RUC110l'II NO I ES
PROVIDE SERVICES TO CLEAN, REPAINT /REPAIR ALL EXTERIOR
SURFACES FOR BUILDING 4434.
REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE
BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,
�NDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM,
F
SIGNAGE, DOOR LANDINGS.
E
REMOVE/REPAIR CHIPPED/MISSING/CRACKED BRICK AT SW END OF
BUILDING.
CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO
CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.
REMOVE RUST AND GRIME FROM OVERHANGS AND OlHER METAL
SURFACES.
PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,
DETERIORATED SEALANT AT �NDOWS, DOORS, MISC. WALL EXTERIOR
PENETRATIONS, ETC.
PRESSURE WASH WllH WATER ONLY, CHEMICALS AND DETERGENTS ARE NOT ALLOWED. USE CARE TO PREVENT DAMAGE, OR FURlHER DAMAGE
FOR OCCURRING.
ENSURE lHE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL
SPRAYED/CLEANED, ACCORDING TO INDUSTRY STDS.
CLEAN �NDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME
REMOVAL.
REPAIR SMALL CRACKS AND VOIDS IN BRICK MASONRY, AS NECESSARY
USE ULTRA SPEC MASONRY ELASTOMERIC WATERPROOF COATING LOW
LUSTRE (360), OR EQUAL.
CLEAN OUT ALL GUTTERS AND REPAIR ALL LEAKS IN GUTTER JOINTS.
ADJUST GUTTER AND SPLASH BLOCK TO ENSURE POSITIVE WATER
DRAINAGE AWAY FROM BUILDING.
PAINT EXTERIOR METAL TRIM, DOORS AND FRAMES. USE A RUST
INHIBITOR PRIMER ON METAL DOORS, FRAMES, AND OVERHANGS.
BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.
*DO NOT PAINT ALUMINUM.
SEAL BRICK FOLLO�NG PATCH WORK AND CLEANING:
BENJAMIN MOORE BLOCK SEAL AS PRIMER AND FINISH COAT, OR
EQUAL
PAINT METAL PANEL ABOVE BRICK; COLOR TO MATCH KIRBY PVDF
COOL COLORS (WARM �ITE), OR APPROVED EQUAL.
PAINT CONCRETE CURBS AT ROLL-UP DOORS; PAINT COLOR:SAFETY
YELLOW.
Rat15k:iN PAre
AR 1$1X,ATJON ..¥P TRANINE:i at..fMW
KEESLER AIR FORCE BASE
O'FIC.f. OF c;.ML ENE:i11ti:R$
G¥ll&i □lnl�©l □lnl ���@IT' □@IT' �@©l�□lnl� �W��@m
�it@lf'@@@ ��cdl@o ca ���� SllMITTED:
(c.hief of '-ontracts Pesign)
A. MARASCA
DE51E'll\6r. aE!,KED;
L. ASHLEY G. REED
(c.hiel of Engineering)
G.REED
VARIES
L.ASHLEY
PATE: f'l¼E(.T �:
29 JULY 2020 MAHG 13-1002
r1t-LlfY �:
Bldg. 4434 - Storage Bldg at Transportation [;RAWNE';I N.MrlER::
A1.2
� 4 a- 7
1 0
D
C
B
A
1557824398E Text Box
1557824398E
14'-0"
E
D
C
B
A
PROJECT SITE
N
I "' N
I
N N
�tr � 0 u ---
�.I'�
.I' .I' p
(2/ fv1_ 2-,u
-n a�
C rj f1 I
2-. ..
w?=\JnJQ (VrvJ a� a� C_
�M 2-,u
·n w
LJ!
�1
,p2IDI fYl w
M w
W
JJ
lJY7
' L w
1 KEYPLAN - EXISTING
A1 .3 SCALE: 1 /16" -1 '-0"
S�N NORTH
E
1 2
[Y7 fYl M ' w rvJ fv1_ -M-LM
I
ESTIMATED BUILDING
HEIGHT - 24'-0"
I cl I
\J \...
u u l)
CLEAN EXTERIOR BLDG
SURFACE AREAS &
SIDEWALKS, INCLUDING J L
PENTHOUSES ON ROOF. SEE
[Y7
PROVIDE & INSTALL NOTE
�r II� fl
PAINT ALL STUCCO/EIFS WALLS.
INCLUDING PENTHOUSES ON ROOF
SEE PROVIDE & INSTALL NOTE FOR
COLOR SELECTION
fl- ---fvl Lfv1 w 1A
C
111 " y fvl-LM LfY1 w w
C n
::"I C
JYl M
-V--riAl iA)
-=11
1111111
-w c w-
318'-3"
4 5
1A
PRIOR TO PRESSURE WASHING,
VERIFY AND REMOVE LOOSE
SPALLING. REPAIR STUCCO SOFFIT
(AROUND ENllRE BUILDING) TO
ADDRESS MOISTURE PENETRATION,
SPLITllNG, RUST CORROSION, CRACKS AND SPALLED CONCRETE.
I\._RE PAIR DAMAGED JOINT
ALANTS, CHIPS, CRACKS,
DS AND/OR DAMAGES
WALL IN ITS ENllRETY, LY AS NECESSARY. USE
LOR-MATCHED SEALANT
SEAL CRACKS.
---fY7
SE
VOi
TO
ON
co
TO
LjYj
� Fil " ' � 3 1A l\__ CLEAN EXTERIOR LIGHTING
(FIXTURE AND LENS).
REMOVE FIXTURE (TO
CLEAN) ONLY AS
NECESSARY.
PAINT EXTERIOR DOORS, FRAMES,
AND LOUVERS (STEEL ONLY):
COLOR TO MATCH MEDIUM BRONZE,
OR EQ. USE A RUST INHIBITOR
PRIMER ON METAL DOORS, FRAMES,
LOUVERS, AND OVERHANGS. - SEE
PROv1DE AND INSTALL NOTE.
---fvl w fv1_
----M vJirJQ
7j=
I\_CL EANING, PAINT AND/OR
PAIRS TO INCLUDE
NTHOUSES ON ROOF.
RE
PE
RE MOVE RUST & GRIME
FR
!L(�T
FR
J
OM OVERHANGS AND/OR
HER METAL SURFACES
WINDOWS, DOOR
AMES, ETC.
(l[rlF; -; AP
-'-._INH
PLY ANTI-RUST
IBITOR PRIMER AND
e s
PAI NT AT EXPOSED STEEL
AMS AT SECOND LEVEL BE
REMOVE MOLD, DIRT, MILDEW
AND/OR ALGAE FROM
BUILDING EXTERIOR SURFACES
- ALL WALLS (BRICK, EIFS,
CMU), WINDOWS, DOORS,
LOUVERS, LIGHTS, SIGNS,
SIDEWALKS, AND PENTHOUSES
ON ROOF, INCLUDING SCREEN
WALLS, TRASH PAD SCREEN
WALLS, BOLLARDS, AND
SURROUNDING SMOKE BREAK
A'wNINGS IN THE AREA.
fv1Jnl.; -/ j □ I\ _:--i u.
"s 1 nAI LAJ
L REMOVE DIRT FROM
LIGHT FIXTURES
(FIXTURE AND LENS).
REMOVE FIXTURE (TO
CLEAN) ONLY AS
NECESSARY.
*CONTRACTOR TO FIELD VERIFY
ALL DIMENSIONS AND CONDITIONS.*
6 7
9 1 0
GENERAL NOlES
1. IT IS RECOMMENDED THAT THE CONTRACTOR FIELD VERIFY ALL
EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF G
CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS
THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS
DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - AClUAL
DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION
DEBRIS DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND
BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR
SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED
STA TE, AS APPROVED BY THE CONTRACTING OFFICER.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,
SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE
CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNllURE, EQUIPMENT, ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR
TO WORK.
CONSTRUC110N NO I ES
PROVIDE SER'v1CES TO CLEAN, REPAIR, AND REPAINT ALL EXTERIOR
SURFACES FOR BUILDING 4330.
PRIOR TO PRESSURE WASHING, VERIFY AND REMOVE LOOSE AND
SPALLING MATERIAL FROM OVERHANG/SOFFIT, AND REPAIR. REMOVE
RUST FROM EXISTING METAL SURFACES AND APPLY RUST INHIBITOR
PRIMER TO METAL SURFACES. PATCH AS STATED IN THE SOW.
REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE
BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,
WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXlURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, PENTHOUSES ON ROOF, INCLUDING SCREEN
WALLS, TRASH PAD SCREEN WALLS, BOLLARDS, AND SURROUNDING
SMOKE BREAK AWNINGS IN THE AREA.
CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXlURE AS REQUIRED TO
CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.
REMOVE RUST, GRIME AND PEELING PAINT FROM OVERHANGS AND
OTHER METAL SURFACES.
CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME
REMOVAL
REMOVE AND REPLACE JOINT SEALANT AND BACKER ROD.
REPAIR DAMAGE TO EIFS WALL SURFACES. MATCH SURROUNDING
FINISHES AND COLOR.
CLEAN EXTERIOR LOUVERS.
PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE
TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURRING.
ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL
SPRAYED/CLEANED, ACCORDING TO INDUSTRY STDS.
PAINT HM DOOR, FRAMES AND LOUVERS, COLOR TO MATCH EXISTING.
APPLY RUST INHIBITOR PRIMER ALL HOLLOW METAL SURFACES .
BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.
•DO NOT PAINT ALUMINUM.
PAINT ALL SlUCCO/EIFS WALLS. MATCH EXISTING FINISH AND PAINT.
PAINT BOLLARDS; PAINT COLOR: SAFETY YELLOW.
REVISION PATE
I..NITI:PSl"ATe$AIRrORt;e l'F<AWN """"""'
AR e:Dl.t,ATION � TRAINNei UM-.4AW
KEESLER AIR FORCE BASE
IM® □ ITTl�® □ITTl �m®IT'□@[l' (C@®�□ ITTl@ �w��®ITTnl W@�i@ [l=l]@l�� ., ���@
51.l)NIJTEP: �' rn:.urv�= (t,hief of 6-ontr<1ch Design) (t,hiet of Engineering)
A. MARASCA G.REED 4330 - Wolfe Hall �eH:P: "1ea<EI> "'-'E DRAWNei N..t44:R:
L. ASHLEY G.REED VARIES A1.3 """"'' PATE: �T�:
LASHLEY 29 JULY 2020 MAHG 13-1002 ,,__s_,,. 7
9 1 0
F
E
D
C
B
A
E
D
C
B
A
PROJECT SITE
oD f---- --•.4@ 0
,& C 4330 t?�f97b lb��db
� i----:�=' t?
t?
t?
I\
I N N
I I I
(l ,I\ ll b rYl
[z::::l�LJ 01!
i-----,..
1--/ rs_ [A n!,l'I (1 rYl
1 KEYPLAN - EXISTING
A1 .4 SCALE: 1 /16" -1 '-0"
rYl
LAJ
rYl
LAJ LAJ
c" rYl I 5-17
LAJ
w
S�N NORTH
E rYl fl
2,fl
LAJ
4 5
L
I
C
C
(l"".=i
J:J cl r rYl_ [J, rYl<= ==rYl
LAJ ]
"u II
LC
rYl I\
] rYl rYl_ ''.:J 11·-
\J
\J-\J LAJ
69,376 SF - TOTAL Li==
ESTIMATED BUILDING
HEIGHT - 40'-9"
<; II
314'-2"
4 5
CLEAN EXTERIOR BLDG
PAINT ALL STUCCO/EIFS
WALLS, INCLUDING
PENTHOUSES ON ROOF-
PRIOR TO PRESSURE WASHING,
VERIFY AND REMOVE LOOSE
SPALLING REPAIR STUCCO SOFFIT
SID��:[�i.
E
1tic��Nt SEE PROVIDE & INST AL
�\PENTHOUSES ON ROOF SEE
NOTE FOR COLOR
PROVIDE & INSTALL
NOTE
SELECTION
r {AROUND ENTIRE B
ADDRESS MOISTURE
SPLITTING, RUST C
CRACKS ANO SPAL
UILDING) TO
PENETRATION,
ORROSION,
LED CONCRETE.
rYl
�LAJ
1 Ug
(l rYl rYl
= =1i'LJ \Jlr l:::,<::J rYl rYl�rln XI/\
LAJ -w v
- REP
SEA
VOID
AIR DAMAGED JOINT
LANTS, CHIPS, CRACKS,
S AND/OR DAMAGES
WALL IN ITS ENTIRETY,
Y AS NECESSARY. USE
OR-MATCHED SEALANT
SEAL CRACKS.
TO
ONL
COL
TO
CLEAN EXTERIOR LIGHTING
{FIXTURE AND LENS).
REMOVE FIXTURE (TO
CLEAN) ONLY AS
NECESSARY
PAI NT EXTERIOR DOORS, FRAMES,
AND LOUVERS {STEEL ONLY);
COL OR TO MATCH MEDIUM BRONZE,
EQ. USE A RUST INHIBITOROR
PRI
LOU
MER ON METAL DOORS, FRAMES,
VERS, AND OVERHANGS. - SEE
"1DE AND INSTALL NOTE. PRO
\_CL
RE
PE
EANING, PAINT AND/OR
PAIRS TO INCLUDE
NTHOUSES ON ROOF.
REMOVE RUST & GRIME
FROM OVERHANGS AND/OR r OTHER METAL SURFACES
- WINDOWS, DOOR
FRAMES, ETC.
APPLY ANTI-RUST
INHIBITOR PRIMER AND
PAINT AT EXPOSED STEEL
BEAMS AT SECOND LEVEL.
RE MOVE MOLD, DIRT, MIUDEW
D/OR ALGAE FROMAN
BU ILDING EXTERIOR SURFACES
ALL WALLS (BRICK, EIFS,
LI), \\1NDOWS, DOORS,
LIVERS, LIGHTS, SIGNS,
OEWALKS, AND PENTHOUSES
�M
LO
SI
ON
WA
ROOF, INCLUDING SCREEN
LLS, TRASH PAD SCREEN
LLS, BOLLARDS, AND
RROUNDING SMOKE BREAK
'W'NINGS IN THE AREA.
WA
SU
A
I'--- REMOVE DIRT FROM
LIGHT FIXTURES
{FIXTURE AND LENS).
REMOVE FIXTURE (TO
CLEAN) ONLY AS
NECESSARY
*CONTRACTOR TO FIELD VERIFY
ALL DIMENSIONS AND CONDITIONS.*
6 7
9 1 0
GEIERAL NOTES
1. IT IS RECOMMENDED THAT THE CONTRACTOR FJELD VERIFY ALL
EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF
CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDlllONS
THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS
DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL
DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION
DEBRIS DURING CONSTRUCTION.
3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND
BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR
SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED
STATE, AS APPROVED BY THE CONTRACTING OFFICER.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL CONTRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF THERE ARE DIFFERING CONDITIONS IN THE FJELD FROM THE SOW,
SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE
CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,
ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR
TO WORK.
CONSTRUC110N Mui ES
PROVIDE SERVICES TO CLEAN, REPAIR, AND REPAINT All EXTERIOR
SURFACES FOR BUILDING 4330.
PRIOR TO PRESSURE WASHING, VERIFY AND REMOVE LOOSE AND
SPALLING MATERIAL FROM OVERHANG/SOFFIT, AND REPAIR. REMOVE
RUST FROM EXISTING METAL SURFACES AND APPLY RUST INHIBITOR
PRIMER TO METAL SURFACES. PATCH AS STATED IN THE SOW.
REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE
BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,
WINDOWS, LOUVERS, OVERHANGS/SOFFlTS, LIGHT FIXTURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, PENTHOUSES ON ROOF, INCLUDING SCREEN
WALLS, TRASH PAD SCREEN WALLS, BOLLARDS, AND SURROUNDING
SMOKE BREAK AWNINGS IN THE AREA.
CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO
CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.
REMOVE RUST, GRIME AND PEELING PAINT FROM OVERHANGS AND
OTHER METAL SURFACES.
CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME
REMOVAL.
REMOVE AND REPLACE JOINT SEALANT AND BACKER ROD.
REPAIR DAMAGE TO EIFS WALL SURFACES. MATCH SURROUNDING
FINISHES AND COLOR.
CLEAN EXTERIOR LOUVERS.
PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE
TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURRING.
ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL
SPRAYED/CLEANED, ACCORDING TO INDUSTRY SlOS.
PAINT HM DOOR, FRAMES AND LOUVERS, COLOR TO MATCH EXISTING.
APPLY RUST INHIBITOR PRIMER ALL HOLLOW METAL SURFACES.
BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.
*DO NOT PAINT ALUMINUM.
PAINT ALL STUCCO/EIFS WALLS. MATCH EXISTING FINISH AND PAINT.
PAINT BOLLARDS: PAINT COLOR: SAFETY YELLOW.
Rat15k:iN PAre
AR 1$1X,ATJON ..¥P TRANINE:i at..fMW
KEESLER AIR FORCE BASE
O'FIC.f. OF c;.ML ENE:i11ti:R$
M® □ ITTl�® □ ITTl �m®IT' □@[l' CC@®� □ ITTlij �,��®M ���®® [}-0��� C ���1
SllMITTED:
(c.hief of '-ontracts Pesign)
A. MARASCA
DE51E'll\6r. aE!,KED;
L. ASHLEY G. REED
(c.hiel of Engineering)
G.REED"""'
VARIES
- PATE: f'l¼E(.T �:
L. ASHLEY
29 JULY 2020 MAHG 13-1002
Bldg. 4331 -Allee Hall [;RAWNE';I N.MrlER::
A1.4
� 6 a- 7
1 0
G
F
E
D
C
B
A
1557824398E Text Box 24'-0"
D
L
C
B
A
1 2
AC AB AA
I
V
.JI!. �I 11 I
\__ REMOVE LEAD BASED PAINT FlROM RAILING
PER BASE REGULATIONS, SEE SOW. PREPARE
FOR PRIME AND PAINT. PRIME AND PAINT.
2A A 1.5
A
1A A1 .0
NORTH ELEVATION
SCALE: 1 /8" = 1'-0"
B C cd�;�RACTI�
I
□�PRI Al : ND
PAI OOR.
I
I I
L REMOVE LEAD BASED PAINT FROM RAILING
AND DOOR FRAME PER BASE REGULATIONS,
SEE SOW. PREPARE FOR PRIME AND PAINT. PRIME ,
PRIME AND PAINT.
SOUTH ELEVATION
SCALE: 1 /8" = 1 '-0"
r, � 5
A1 .5
R
KEYPLAN - EXISTING
SCALE: 1 "=30' -0"
Q p
J
REMOVE LEAD BASED PAINT FROM RAILING
PER BASE REGULATIONS, SEE SOW.
PRIME AND PAINT.
2B NORTH ELEVATION
A1 .5 SCALE: 1 /8"=1'-0"
J
[jl\
• Ci2
REMOVE LEAD BASED PAINT FROM RAILING --"'..,.
PER BASE REGULATIONS, SEE SOW. PREPARE
FOR, AND PRIME AND PAINT.
1B SOUTH ELEVATION
A1.0 SCALE: 1/8"=1'-0"
2C
1.5 w5
K
� 5
L
MOVE LEAD BASE Al
OM DOOR FRAM ·· -
K J
,Si��I I
L
REMOVE LEAD BASED PAINT FlROM RAILING
PER BASE REGULATIONS, SEE SOW.
PRIME AND PAINT.
2C
A 1.5
M
, •• 'II :
NORTH ELEVATION
SCALE: 1 /8"=1'-0"
:[j n:1::r w
':I
I n o[j[j[j[jt
II L
0 L
II L
p I I
1C p
I
A1.0
6 7
4it 5
H
Ci2
CONTRACTING
Q R lluuuull I
I I
I I
I I
I I
I I
I I
I I
I I
I I '
IOI
' I
-11I
SOUTH ELEVATION
SCALE: 1/8"=1'-0"
6 7
C B
I I
IL REMOVE LEAD BASED PAINT FROM RAILING
AND DOOR FRAMES PER BASE REGULATIONS,
SEE SOW. PRIME AND PAINT.
2D A 1.5
AA
NORTH ELEVATION
SCALE: 1/8"=1'-0"
AB
PRI�:: D----,i,-
PAIN ICOR.
A
I
AC
I
I -....� Fr----i==='='=='========'=='='====='==="='i,==�!,,,._
"91!
..._ -....1,.1
I I II \ / 7-
REMOVE LEAD BASED PAINT FROM RAILING �
AND DOOR FRAME PER BASE REGULATIONS,
SEE SOW. PRIME AND PAINT.
1D SOUTH ELEVATION
A1.0 SCALE: 1/8"=1'-0"
9 1 0
GENBW.NOlES
1. CONlRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSlRUCTION. NOTIFY CONlRACTING OFFICER OF ANY CONDITIONS DElRIMENTAL TO THE COMPLETION OF
THE WORK AS DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE
ONLY - ACTUAL DETAILS MAY VARY.
2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER
EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSlRUCTION DEBRIS DURING CONSlRUCTION.
3. CONlRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR
CONTAMINATED ITEMS.
4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE
SCOPE OF WORK AND SCHEDULE.
5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE
SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONlRACTOR
IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL
MATERIALS TO BE REMOVED IN A TIMELY FASHION.
6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.
7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,
SPECIFICATIONS, AND OR DRAWINGS CONlRACTOR MUST CONTACT THE CONlRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY
WORK.
8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT, ELEClRONICS
AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR TO WORK.
Rat15k:iN PAre
AR 1$1X,ATJON ..¥P TRANINE:i at..fMW
KEESLER AIR FORCE BASE
O'FIC.f. OF c;.ML ENE:i11ti:R$ rM® □[l'i)�® □[l'i) �bK�®[f' □@[l' (C:@®� □[l'i]@ �w��®ITilil
(C:@lli)1t[l'@l©1t□llilij C �(S)(Q)/5) SllMITTED:
(c.hief of '-ontracts Pesign)
A. MARASCA
DE51E'll\6r. aE!,KED;
L. ASHLEY G. REED
(c.hiel of Engineering)
G.REED
VARIES
L.ASHLEY
PATE: f'l¼E(.T �:
29 JULY 2020 MAHG 13-1002
Bldg. 4605 - Contracting [;RAWNE';I N.MrlER::
A1.5
� 7 a- 7
1 0
G
F
E
D
C
B
A
File details come from the government source that posted it. Updated .