Attachment 3 - DWG_ MAHG131002_ 29 July 2020.pdf

PDF 7 MB Posted

Attached to
Maintain Exterior Coatings of Various Facilities Federal contract opportunity
Solicitation number
FA301020R0032
Issued by
Department of the Air Force Air Education and Training Command

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G

F

E

D

C

B

A

1 2 3 4 5 6 7 8

KEESLER AFB, MISSISSIPPI

MAINTAIN EXTERIOR COATING SYSTEMS

I

., __ ...,u ;al ti.� 4 :WATER) ,�, ii ,,11: _:

JACKSON

.G··.·.·.·.·.·.·.·.·.·.·.·-·.·.·.·.·.·.·.·.·.·.·.·.· .

. ·•·• ULFPORT

. . . . . . . . . . . . . . ' ' . . . . . . . . . . . . . . lliil�IIITT\ �I � �

GULFPORT 4 BILOXI /

:t BILOXI, MS

VICINITY MAP

LOCATION PLAN

KEESLER AFB, MS

SCALE: NONE

INDEX OF DRAWINGS

T1 .0 TITLE SHEET

A1.0 4332 -WEATHER BUILDING - KEY PLAN, ELEVATIONS, NOTES, PHOTOS

A1.1 1203-GAUDE LANE-KEYPLAN, ELEVATIONS, NOTES

A1.2 4434- STORAGE BLDG AT TRANSPORTATION- KEYPLAN, ELEVATIONS, NOTES

A 1.3 4330 - WOLFE HALL - ELEVATIONS, NOTES, PHOTOS

A 1.4 4331 - ALLEE HALL - ELEVATIONS, NOTES, PHOTOS

A 1.5 4605 -CONTRACTING

1 2

AFF

BLDG

CONC.

CONT.

E

EIFS

EJT

EL

ENTR

EQ

EXIST

EXT

FBR

FIN

FL

FT

GAL

GEN

GR

ABOVE FINISH FLOOR

BUILDING

CONCRETE

CONTINUOUS

EXISTING

ABBREVIATIONS

EXTERIOR INSULATION & FINISH SYSTEM

EXPANSION JOINT

ELEVATIONS

ENTRANCE

EQUAL

EXISTING

EXTERIOR

FACE BRICK

FINISH

FLOOR

FOOT/FEET

GALLONS

GENERAL

GRADE

__ -e

H

HC

HT

INSUL

JT

LT

LTG

LVR

MATL

MET

MIN.

MO

NA

NIC

oc

PNT

TYP

W/

4332 - WEATHER BUILDING

1203 - GAUDE LANE

4434 - STORAGE BUILDING

4330 - WOLFE HALL

4331 - ALLEE HALL

4605 - CONTRACTING

HEIGHT

HANDICAP

HEIGHT

INSULATION

JOINT

LIGHT

LIGHTING

LOUVER

MATERIAL

METAL

MINIMUM

MASONRY OPENING

NOT APPLICABLE

NOT IN CONTRACT

ON CENTER

PAINTED

TYPICAL

WITH

MATERIAL LEGEND

I ·<i,:· ··"· '� :-d :I : 4.. . 1

11111111111 tAArul

CONCRETE

CONCRETE

MASONRY UNIT

BRICK

EXTERIOR INSULATION

AND FINISH SYSTEM

(EIFS)

ARCHITECTURAL SYMBOLS

'B KEY NOTES

ROOM NUMBERS

9 10

Re'IISION I t:¥irt: PRAWN I - 1.Nrrl:P STATES AIF!. � M<. EP!.t'.ATION ,tt,i;, TRAINlll8 UM.4AW

KEESLER AIR FORCE BASE

ff� tF C.IVIL ENE>ll'l:l:R5

M �� lNlu �� lNl ��u � [Pi1 � (Q) [Pi1

�(Q)� u�lNl� �w�1�U01J

G

F

E

D

C

B

BUILDINGS - 4332, 1203, 4434, 4330, 4331, 4605 A

,a,f.MITTfP: �: r">a..ITY t,I.Ml:IER:

(C,hiet of C.ontrach V"11ign) (C,hief of Engineering) 4332, 1203, 4434, 4434, A.MARASCA G.REED 4331, 4605

DRA'MNl!:IMJ-,CER:

T1 .0 -TITLE SHEET �;.y II �d II �IES �;ley- II 29 JULY 202011 =�=02 """'" 1 .,. 7

9 10

D

C

B

A

I

1 2 3

PROJECT SITE

0;04_J 0 C __.--' , DDD

CJ CJ CJ

J

D oD "'-'-'--1 ���,L_C____ _ ___J

��.rt� 0 ti '11�� 1�

PAINT CAST IRON BOOT

(ONLY) AT DOWNSPOUT

(MEDIUM BRONZE); CLEAN

ALUMINUM GUTTERS AND

DOWNSPOUTS ONLY, NO

PAINT.

CLEAN EXTERIOR

LOUVERS, AND

LIGHTING FIXTURES

(FIXTURE & LENS).

REMOVE FIXTURE

TO CLEAN ONLY

AS NECESS

:¼PAINT ,

BOLLARDS,

SAFETY

YELLOW

PAINT SNACK

AREA SHED,

COLOR TO MATCH

EXISTING, OR EQ.

- SEE PROVIDE &

INSTALL NOTE.

10·-o·

1 KEYPLAN - EXISTING

CLEAN EXTERIOR

BLDG. SURFACE

REMOVE MOLD, DIRT, MILDEW AND/OR

ALGAE FROM BLDG. EXTERIOR SURFACES

- ALL WALLS, RUBBED CONCRETE,

WINDOWS, DOORS, LOUVERS, LIGHTS,

SIGNS/LETTERS, EXITS, SIDEWALKS, STEPS

& ROOF, TO INCLUDE OBSERVATION DECK.

EXISTING�CONCRETE STEPS ,

121'-4"

A1 .0 SCALE: 1/16"=1'-0"

1 2 3

LAJ

[Yl

24'-10"

REMOVE RUST FROM

OVERHANGS AND/OR OTHER

METAL SURFACES - WINDOWS

AND DOOR FRAMES

CLEAN LIGHT

FIXTURES AT

ENTRANCES

83,685 SF -

C

TOTAL

5 6

PRIOR TO PRESSURE

WASHING, REMOVE &

REPAIR CRACKED

I DETERIORATED SEAL AT

� CONCRETE SIDEWALK

�=====�=�5'

WHERE BRICK WALL

Ir MEETS PAVEMENT AT

DOOR OPENING AT EAST

AND WEST ENTRANCES

AND PREP FOR REPAIR.

ESTIMATED BLDG

HEIGHT: 27'-8"

PRIOR TO PRESSURE WASHING,

REMOVE & REPAIR CRACKED

DETERIORATED CONCRETE

PANEL JOINT SEALANT AT

RIGHT CORNER OF SOUTH

ENTRANCE WALL.

121'-4"

*CONTRACTOR TO FIELD VERIFY

ALL DIMENSIONS AND CONDITIONS.*

5 6

1 o·-o·

CLEAN WINDOWS,

DOORS, AND DOOR

FRAMES AFTER RUST

AND GRIME REMOVAL

r-

LO

r<)

A 1.0

55'-211

OBSERVATION DECK - 3RD FL

SCALE: 1/16"=1'-0"

CLEAN EXTERIOR BUILDING

SURFACE (THIRD FL);

STOREFRONT WITH PANELS,

ABOVE & BELOW.

9 1 0

GENBW.NOlES

1. IT IS RECOMMENDED THAT THE CONTRACTOR FIELD VERIFY ALL

EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF G

CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS

THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS

DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION

DEBRIS DURING CONSTRUCTION.

3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND

BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR

SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED

STATE, AS APPROVED BY THE CONTRACTING OFFICER.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,

SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE

CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,

ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR

TO WORK.

CONSTRUC110N N01ES

PROVIDE SERVICES TO CLEAN, REPAINT /REPAIR ALL EXTERIOR

SURFACES FOR BUILDING 4332.

F

REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE E BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS, WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, RAMPS, EXITS, SIDEWALKS, INCLUDING

SCREEN WALLS AT SMOKING AND TRASH COMPARTMENT.

CLEAN EXTERIOR BUILDING SURFACE (THIRD FLOOR); STOREFRONT WITH

PANELS, ABOVE AND BELOW.

CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO

CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.

REMOVE RUST AND GRIME FROM OVERHANGS AND OTHER METAL

SURFACES.

CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME

REMOVAL.

RESTORE/REPAIR PRECAST CONCRETE PANELS, USE COLOR-MATCHED

EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, INCLUDING

CONSTRUCTION AND EXPANSION JOINTS; COLOR TO MATCH EXISTING.

REPAIR SMALL CRACKS AND VOIDS IN CONCRETE (BLDG. SKIRT), AS

NECESSARY. USE ULTRA SPEC MASONRY ELASTOMERIC WATERPROOF

COATING LOW LUSTRE (360), OR EQUAL.

CLEAN EXTERIOR LOUVERS.

PRIOR TO PRESSURE WASHING, REPAIR SEAL AT CONCRETE SIDEWALK

WIHERE BRICK WALL MEETS PAVEMENT AT DOOR OPENING AT THE EAST

AND WEST ENTRANCES.

PRIOR TO PRESSURE WASHING, REPAIR PANEL JOINT SEALANT AT

RIGHT CORNER OF SOUTH ENTRANCE WALL. USE COLOR-MATCHED

EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, AS NEEDED; COLOR

TO MATCH EXISTING (CREAM), OR EQUAL).

PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,

DETERIORATED SEALANT AT WINDOWS, DOORS AND PANEL JOINTS AS

NECESSARY.

PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY, CHEMICALS

D

AND DETERGENTS ARE NOT ALLOWED. USE CARE TO PREVENT DAMAGE,

COR FURTHER DAMAGE FROM OCCURRING.

ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL

SPRAYED/CLEANED, ACCORDING TO INDUSTRY SIDS .

PAINT HM DOOR AND FRAMES, COLOR TO MATCH EXISTING.

PAINT BOLLARDS AT ROLLUP DOOR; PAINT COLOR: SAFETY YELLOW.

PAINT SNACK AREA SHED, COLOR TO MATCH EXISTING, OR EQUAL.

PAINT CAST IRON BOOTS AT DOWNSPOUT (MEDIUM BRONZE); CLEAN

ALUMINUM GUTTERS AND DOWNSPOUTS ONLY, NO PAINT.

Rat15k:iN PAre

AR 1$1X,ATJON ..¥P TRANINE:i at..fMW

KEESLER AIR FORCE BASE

O'FIC.f. OF c;.ML ENE:i11ti:R$ rM® □[l'i)�® □[l'i) �bK�®[f' □@[l' (C:@®�□[l'i]@ �w��®ITilil W@®it[h]@[l' ��@!� ., ����

SllMITTED:

(c.hief of '-ontracts Pesign)

A. MARASCA

DE51E'll\6r. aE!,KED;

L. ASHLEY G. REED

(c.hiel of Engineering)

G.REED"""'

VARIES -

L.ASHLEY

PATE: f'l¼E(.T �:

29 JULY 2020 MAHG 13-1002

Bldg. 4332 - Weather Building [;RAWNE';I N.MrlER::

A1.0

� 2 a- 7

1 0

B

A

1557824398E Text Box

1557824398E Text Box

E

D

C

B

A

1 2

D

PRECAST

ELS;SEAL

PROcE&T SITE

HST

IT TIIT

REMOVE MOLD, DIRT, MILDEW AND/OR ALGAE

FROM BLDG EXT SURFACES AND MORTAR

JOINTS (WITHOUT DAMAGE TO BRICKWORK) -

ALL WALLS, RUBBED CONCRETE, WINDOWS, -

DOORS, LOUVERS, LIGHTS, SIGNS, RAMPS,

EXITS, SIDEWALKS, & ROOF, INCLUDING SCREEN

WALLS, AND TRASH PAD SCREEN WALLS

C.

J.I i-

RESTORE

CONCRETE PAN

CRACKS A

INCLUDING C

EXPANSION JOIN

PROVIDE & INST

ND CHIPS!

ONSTR. &

TS - SEE

ALL NOTE

CLEAN EXTERIOR

BLDG SURF ACE

'o I ""'

12·-o"

L/STEEL

FRAME

OLOR TO

PAINT DOOR

(HOLLOW META

ONLY), C

MATCH EXIS

EQUAL - SEE

& INSTA

TING, OR

PROVIDE

LL NOTE

1 KEYPLAN - EXISTING

A 1.1 SCALE: 1 /16"=1 '-0"

REMOVE DIRT FROM LIGHT

FIXTURES (FIXTURES AND

LENS), REMOVE FIXTURE (TO

CLEAN) ONLY AS NECESSARY

l

REMOVE RUST AND GRIME

FROM OVERHANGS AND/OR

OTHER METAL SURFACES -

WINDOWS, DOOR FRAMES,

ETC.

CLEAN EXTERIOR

LOUVERS LIGHT

. :7

FIXTURES & BLDG

EXTERIOR SURFACES

I 0

I

;==I

RESTORE SMALL CRACKS

AND VOIDS IN CONCRETE

(BLDG. SKIRT), AND

ROUGH MASONRY AS

NECESSARY

1 1 1

I l I�

30'-6"

22,004 SF - TOTAL i---:i \ \ \

0 ESTIMATED BUILDING � I

HEIGHT - 19'-0"

I

J LIU I ULJI - ■ ■ ■ ■

Jl ■ r nn g ■

■ _e f- ■ J=

■ - � � [l�

I ■ - F ■ [l f- -

■ [I ■ -

= II ■ -i

• t:I• ! • h I I c:::::r-7 " --

I ]

140'-o" 44'-o"

3 4

CL

*N

I

<I]

I --"'- I

<I]

I

EAN EXTERIOR BLDG SURF ACES;

ON-ADJACENT WALLS INCLUDED

7 8

7 8

9 1 0

GENBW.NOlES

1. IT IS RECOMMENDED 11-IAT TI-IE CONTRACTOR FIELD VERIFY ALL

EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF

G CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS

11-IAT COULD AFFECT TI-IE SUCCESSFUL COMPLETION OF TI-IE WORK AS

DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND 011-IER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION

DEBRIS DURING CONSTRUCTION.

3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND

BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR

SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED

STA TE, AS APPROVED BY TI-IE CONTRACTING OFFICER.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN TI-IE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM TI-IE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF THERE ARE DIFFERING CONDITIONS IN TI-IE FIELD FROM TI-IE SOW,

SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT TI-IE

CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING Will-I ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,

ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR

TO WORK.

CONSTRUC110N M.> i ES

PROVIDE SERVICES TO CLEAN, REPAINT/REPAIR ALL EXTERIOR

SURFACES FOR BUILDING 1203.

REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM TI-IE

BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,

WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM,

SIGNAGE, DOOR LANDINGS, RAMPS, EXITS, SIDEWALKS, INCLUDING

SCREEN WALLS, AND TRASH PAD SCREEN WALLS.

CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO

CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.

REMOVE RUST AND GRIME FROM OVERHANGS AND 011-IER METAL

SURFACES.

PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,

DETERIORATED SEALANT AT WINDOWS, DOORS AND PANEL JOINTS AS

NECESSARY.

PRESSURE WASH Will-I WATER ONLY, CHEMICALS AND DETERGENTS ARE

NOT ALLOWED. USE CARE TO PREVENT DAMAGE, OR FURTI-IER DAMAGE

FROM OCCURRING.

ENSURE TI-IE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL

SPRAYED/CLEANED, ACCORDING TO INDUSTRY SIDS.

CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME

REMOVAL.

PAINT HM DOOR AND FRAMES, COLOR TO MATCH EXISTING.

RESTORE/REPAIR PRECAST CONCRETE PANELS, USE COLOR-MATCHED

EXTERIOR SEALANT TO SEAL CRACKS AND CHIPS, INCLUDING

CONSTRUCTION AND EXPANSION JOINTS; COLOR TO MATCH EXISTING.

REPAIR SMALL CRACKS AND VOIDS IN CONCRETE (BLDG. SKIRT), CMU,

AND ROUGH MASONRY (BRICK), AS NECESSARY. USE ULTRA SPEC

MASONRY ELASTOMERIC WATERPROOF COATING LOW LUSTRE (360), OR

EQUAL.

CLEAN EXTERIOR LOUVERS.

Rat15k:iN PAre

AR 1$1X,ATJON ..¥P TRANINE:i at..fMW

KEESLER AIR FORCE BASE

O'FIC.f. OF c;.ML ENE:illti:R$

U¥ll@ □ITTlU@□ITTl ��U®IT'□@IT' �@@UDITTl@ �W�U®M

@®lYl©I® IL®ITTl@ "" i �@� SllMITTED:

(c.hief of '-ontracts Pesign)

A. MARASCA

DE51E'll\6r. aE!,KED;

L. ASHLEY G. REED

(c.hiel of Engineering)

G.REED

VARIES -

L.ASHLEY

PATE: f'l¼E(.T �:

29 JULY 2020 MAHG 13-1002

Bldg. 1203 - GAU DE LANE [;RAWNE';I N.MrlER::

A1.1

� 3 a- 7

1 0

F

E

D

C

B

A

1557824398E Text Box

D

C

B

A

1 2

PROJECT SITE ---

I in I")

REPLACE CHIPPED

MISSING

CRACKED

BRICK AT SW END OF BLDG.; BRICK

COLOR TO MATCH EXISTING OR

EQUAL. SEE PROVIDE & INSTALL

NOTE

3,333 SF - TOTAL

ESTIMATED BUILDING

HEIGHT - 13'-3"

DOOR 1

C

' •I

PAINT DOOR

EXT-�1 --1:;;--x RECAULK AROUND EXTERIOR

SIDE) AND WINDOW

TRIM; COLOR TO

MATCH MEDIUM

BRONZE OR EQUAL

DOOR

OFFICE) AND WINDOW;

CLEAN BOTH SIDES OF WINDOW

& DOOR AFTER RUST & GRIME

REMOVAL

w

93' -3"

DOOR 2 DOOR 3

\_CLEAN EXTERIOR

BLDG SURFACE

AREAS, SIDEWALKS

INCLUDED

1 KEYPLAN - EXISTING

S�N NORTH

A 1.2 SCALE: 3/16" =1'-0" E

1 2 3

DOOR 4

\_PAINT CONCRETE)

BOLLARDS, AT

ROLL-UP DOORS;

PAINT COLOR:

SAFETY YELLOW

DOOR 5

DOOR 6

rREMOVE RUST AND

GRIME FROM OVERHANGS

AND

OR OTHER METAL

SURFACES - WINDOW,

DOOR FRAMES, ETC.

PAINT METAL PANEL

ABOVE BRICK; SEE

PROVIDE AND INSTALL

NOTE

rPRIOR TO PRESSURE

WASHING, USE

COLOR-MATCHED

EXTERIOR SEALANT TO

SEAL CRACKS AND CHIPS,

ONLY AS NECESSARY

MATCH EXISTING

CREAM),

OR EQUAL.

rREMOVE DIRT FROM

LIGHT FIXTURES

FIXTURE & LENS).

REMOVE FIXTURE

TO

CLEAN) ONLY AS

NECESSARY.

�REMOVE MOLD, DIRT, MILDEW AND

OR ALGAE

FROM BUILDING EXTERIOR SURFACES AND MORTAR

JOINTS

WITHOUT DAMAGE TO BRICKWORK) -ALL

WALLS

METAL PANEL AND BRICK), WINDOW,

DOOR, ROLL-UP METAL DOORS, AIR CONDITIONER,

LIGHTS, SIGNS, ROOF, CARWASH VACUUM STATION,

AND SIDEWALKS

6 7

9 1 0

GENBW.NOlES

1. IT IS RECOMMENDED lHAT lHE CONTRACTOR FIELD VERIFY ALL

EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF

G CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS

lHAT COULD AFFECT lHE SUCCESSFUL COMPLETION OF lHE WORK AS

DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OlHER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION

DEBRIS DURING CONSTRUCTION.

3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND

BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR

SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED

STATE, AS APPROVED BY lHE CONTRACTING OFFICER.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN lHE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM lHE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF lHERE ARE DIFFERING CONDITIONS IN lHE FIELD FROM lHE SOW, SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT lHE CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING �lH ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,

ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR

TO WORK.

CONS1RUC110l'II NO I ES

PROVIDE SERVICES TO CLEAN, REPAINT /REPAIR ALL EXTERIOR

SURFACES FOR BUILDING 4434.

REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE

BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,

�NDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXTURES, ROOF TRIM,

F

SIGNAGE, DOOR LANDINGS.

E

REMOVE/REPAIR CHIPPED/MISSING/CRACKED BRICK AT SW END OF

BUILDING.

CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO

CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.

REMOVE RUST AND GRIME FROM OVERHANGS AND OlHER METAL

SURFACES.

PRIOR TO PRESSURE WASHING, REMOVE AND REPLACE ALL CRACKED,

DETERIORATED SEALANT AT �NDOWS, DOORS, MISC. WALL EXTERIOR

PENETRATIONS, ETC.

PRESSURE WASH WllH WATER ONLY, CHEMICALS AND DETERGENTS ARE NOT ALLOWED. USE CARE TO PREVENT DAMAGE, OR FURlHER DAMAGE

FOR OCCURRING.

ENSURE lHE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL

SPRAYED/CLEANED, ACCORDING TO INDUSTRY STDS.

CLEAN �NDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME

REMOVAL.

REPAIR SMALL CRACKS AND VOIDS IN BRICK MASONRY, AS NECESSARY

USE ULTRA SPEC MASONRY ELASTOMERIC WATERPROOF COATING LOW

LUSTRE (360), OR EQUAL.

CLEAN OUT ALL GUTTERS AND REPAIR ALL LEAKS IN GUTTER JOINTS.

ADJUST GUTTER AND SPLASH BLOCK TO ENSURE POSITIVE WATER

DRAINAGE AWAY FROM BUILDING.

PAINT EXTERIOR METAL TRIM, DOORS AND FRAMES. USE A RUST

INHIBITOR PRIMER ON METAL DOORS, FRAMES, AND OVERHANGS.

BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.

*DO NOT PAINT ALUMINUM.

SEAL BRICK FOLLO�NG PATCH WORK AND CLEANING:

BENJAMIN MOORE BLOCK SEAL AS PRIMER AND FINISH COAT, OR

EQUAL

PAINT METAL PANEL ABOVE BRICK; COLOR TO MATCH KIRBY PVDF

COOL COLORS (WARM �ITE), OR APPROVED EQUAL.

PAINT CONCRETE CURBS AT ROLL-UP DOORS; PAINT COLOR:SAFETY

YELLOW.

Rat15k:iN PAre

AR 1$1X,ATJON ..¥P TRANINE:i at..fMW

KEESLER AIR FORCE BASE

O'FIC.f. OF c;.ML ENE:i11ti:R$

G¥ll&i □lnl�©l □lnl ���@IT' □@IT' �@©l�□lnl� �W��@m

�it@lf'@@@ ��cdl@o ca ���� SllMITTED:

(c.hief of '-ontracts Pesign)

A. MARASCA

DE51E'll\6r. aE!,KED;

L. ASHLEY G. REED

(c.hiel of Engineering)

G.REED

VARIES

L.ASHLEY

PATE: f'l¼E(.T �:

29 JULY 2020 MAHG 13-1002

r1t-LlfY �:

Bldg. 4434 - Storage Bldg at Transportation [;RAWNE';I N.MrlER::

A1.2

� 4 a- 7

1 0

D

C

B

A

1557824398E Text Box

1557824398E

14'-0"

E

D

C

B

A

PROJECT SITE

N

I "' N

I

N N

�tr � 0 u ---

�.I'�

.I' .I' p

(2/ fv1_ 2-,u

-n a�

C rj f1 I

2-. ..

w?=\JnJQ (VrvJ a� a� C_

�M 2-,u

·n w

LJ!

�1

,p2IDI fYl w

M w

W

JJ

lJY7

' L w

1 KEYPLAN - EXISTING

A1 .3 SCALE: 1 /16" -1 '-0"

S�N NORTH

E

1 2

[Y7 fYl M ' w rvJ fv1_ -M-LM

I

ESTIMATED BUILDING

HEIGHT - 24'-0"

I cl I

\J \...

u u l)

CLEAN EXTERIOR BLDG

SURFACE AREAS &

SIDEWALKS, INCLUDING J L

PENTHOUSES ON ROOF. SEE

[Y7

PROVIDE & INSTALL NOTE

�r II� fl

PAINT ALL STUCCO/EIFS WALLS.

INCLUDING PENTHOUSES ON ROOF

SEE PROVIDE & INSTALL NOTE FOR

COLOR SELECTION

fl- ---fvl Lfv1 w 1A

C

111 " y fvl-LM LfY1 w w

C n

::"I C

JYl M

-V--riAl iA)

-=11

1111111

-w c w-

318'-3"

4 5

1A

PRIOR TO PRESSURE WASHING,

VERIFY AND REMOVE LOOSE

SPALLING. REPAIR STUCCO SOFFIT

(AROUND ENllRE BUILDING) TO

ADDRESS MOISTURE PENETRATION,

SPLITllNG, RUST CORROSION, CRACKS AND SPALLED CONCRETE.

I\._RE PAIR DAMAGED JOINT

ALANTS, CHIPS, CRACKS,

DS AND/OR DAMAGES

WALL IN ITS ENllRETY, LY AS NECESSARY. USE

LOR-MATCHED SEALANT

SEAL CRACKS.

---fY7

SE

VOi

TO

ON

co

TO

LjYj

� Fil " ' � 3 1A l\__ CLEAN EXTERIOR LIGHTING

(FIXTURE AND LENS).

REMOVE FIXTURE (TO

CLEAN) ONLY AS

NECESSARY.

PAINT EXTERIOR DOORS, FRAMES,

AND LOUVERS (STEEL ONLY):

COLOR TO MATCH MEDIUM BRONZE,

OR EQ. USE A RUST INHIBITOR

PRIMER ON METAL DOORS, FRAMES,

LOUVERS, AND OVERHANGS. - SEE

PROv1DE AND INSTALL NOTE.

---fvl w fv1_

----M vJirJQ

7j=

I\_CL EANING, PAINT AND/OR

PAIRS TO INCLUDE

NTHOUSES ON ROOF.

RE

PE

RE MOVE RUST & GRIME

FR

!L(�T

FR

J

OM OVERHANGS AND/OR

HER METAL SURFACES

WINDOWS, DOOR

AMES, ETC.

(l[rlF; -; AP

-'-._INH

PLY ANTI-RUST

IBITOR PRIMER AND

e s

PAI NT AT EXPOSED STEEL

AMS AT SECOND LEVEL BE

REMOVE MOLD, DIRT, MILDEW

AND/OR ALGAE FROM

BUILDING EXTERIOR SURFACES

- ALL WALLS (BRICK, EIFS,

CMU), WINDOWS, DOORS,

LOUVERS, LIGHTS, SIGNS,

SIDEWALKS, AND PENTHOUSES

ON ROOF, INCLUDING SCREEN

WALLS, TRASH PAD SCREEN

WALLS, BOLLARDS, AND

SURROUNDING SMOKE BREAK

A'wNINGS IN THE AREA.

fv1Jnl.; -/ j □ I\ _:--i u.

"s 1 nAI LAJ

L REMOVE DIRT FROM

LIGHT FIXTURES

(FIXTURE AND LENS).

REMOVE FIXTURE (TO

CLEAN) ONLY AS

NECESSARY.

*CONTRACTOR TO FIELD VERIFY

ALL DIMENSIONS AND CONDITIONS.*

6 7

9 1 0

GENERAL NOlES

1. IT IS RECOMMENDED THAT THE CONTRACTOR FIELD VERIFY ALL

EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF G

CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDITIONS

THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS

DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - AClUAL

DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION

DEBRIS DURING CONSTRUCTION.

3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND

BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR

SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED

STA TE, AS APPROVED BY THE CONTRACTING OFFICER.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONTRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,

SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE

CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNllURE, EQUIPMENT, ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR

TO WORK.

CONSTRUC110N NO I ES

PROVIDE SER'v1CES TO CLEAN, REPAIR, AND REPAINT ALL EXTERIOR

SURFACES FOR BUILDING 4330.

PRIOR TO PRESSURE WASHING, VERIFY AND REMOVE LOOSE AND

SPALLING MATERIAL FROM OVERHANG/SOFFIT, AND REPAIR. REMOVE

RUST FROM EXISTING METAL SURFACES AND APPLY RUST INHIBITOR

PRIMER TO METAL SURFACES. PATCH AS STATED IN THE SOW.

REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE

BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,

WINDOWS, LOUVERS, OVERHANGS/SOFFITS, LIGHT FIXlURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, PENTHOUSES ON ROOF, INCLUDING SCREEN

WALLS, TRASH PAD SCREEN WALLS, BOLLARDS, AND SURROUNDING

SMOKE BREAK AWNINGS IN THE AREA.

CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXlURE AS REQUIRED TO

CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.

REMOVE RUST, GRIME AND PEELING PAINT FROM OVERHANGS AND

OTHER METAL SURFACES.

CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME

REMOVAL

REMOVE AND REPLACE JOINT SEALANT AND BACKER ROD.

REPAIR DAMAGE TO EIFS WALL SURFACES. MATCH SURROUNDING

FINISHES AND COLOR.

CLEAN EXTERIOR LOUVERS.

PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE

TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURRING.

ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL

SPRAYED/CLEANED, ACCORDING TO INDUSTRY STDS.

PAINT HM DOOR, FRAMES AND LOUVERS, COLOR TO MATCH EXISTING.

APPLY RUST INHIBITOR PRIMER ALL HOLLOW METAL SURFACES .

BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.

•DO NOT PAINT ALUMINUM.

PAINT ALL SlUCCO/EIFS WALLS. MATCH EXISTING FINISH AND PAINT.

PAINT BOLLARDS; PAINT COLOR: SAFETY YELLOW.

REVISION PATE

I..NITI:PSl"ATe$AIRrORt;e l'F<AWN """"""'

AR e:Dl.t,ATION � TRAINNei UM-.4AW

KEESLER AIR FORCE BASE

IM® □ ITTl�® □ITTl �m®IT'□@[l' (C@®�□ ITTl@ �w��®ITTnl W@�i@ [l=l]@l�� ., ���@

51.l)NIJTEP: �' rn:.urv�= (t,hief of 6-ontr<1ch Design) (t,hiet of Engineering)

A. MARASCA G.REED 4330 - Wolfe Hall �eH:P: "1ea<EI> "'-'E DRAWNei N..t44:R:

L. ASHLEY G.REED VARIES A1.3 """"'' PATE: �T�:

LASHLEY 29 JULY 2020 MAHG 13-1002 ,,__s_,,. 7

9 1 0

F

E

D

C

B

A

E

D

C

B

A

PROJECT SITE

oD f---- --•.4@ 0

,& C 4330 t?�f97b lb��db

� i----:�=' t?

t?

t?

I\

I N N

I I I

(l ,I\ ll b rYl

[z::::l�LJ 01!

i-----,..

1--/ rs_ [A n!,l'I (1 rYl

1 KEYPLAN - EXISTING

A1 .4 SCALE: 1 /16" -1 '-0"

rYl

LAJ

rYl

LAJ LAJ

c" rYl I 5-17

LAJ

w

S�N NORTH

E rYl fl

2,fl

LAJ

4 5

L

I

C

C

(l"".=i

J:J cl r rYl_ [J, rYl<= ==rYl

LAJ ]

"u II

LC

rYl I\

] rYl rYl_ ''.:J 11·-

\J

\J-\J LAJ

69,376 SF - TOTAL Li==

ESTIMATED BUILDING

HEIGHT - 40'-9"

<; II

314'-2"

4 5

CLEAN EXTERIOR BLDG

PAINT ALL STUCCO/EIFS

WALLS, INCLUDING

PENTHOUSES ON ROOF-

PRIOR TO PRESSURE WASHING,

VERIFY AND REMOVE LOOSE

SPALLING REPAIR STUCCO SOFFIT

SID��:[�i.

E

1tic��Nt SEE PROVIDE & INST AL

�\PENTHOUSES ON ROOF SEE

NOTE FOR COLOR

PROVIDE & INSTALL

NOTE

SELECTION

r {AROUND ENTIRE B

ADDRESS MOISTURE

SPLITTING, RUST C

CRACKS ANO SPAL

UILDING) TO

PENETRATION,

ORROSION,

LED CONCRETE.

rYl

�LAJ

1 Ug

(l rYl rYl

= =1i'LJ \Jlr l:::,<::J rYl rYl�rln XI/\

LAJ -w v

- REP

SEA

VOID

AIR DAMAGED JOINT

LANTS, CHIPS, CRACKS,

S AND/OR DAMAGES

WALL IN ITS ENTIRETY,

Y AS NECESSARY. USE

OR-MATCHED SEALANT

SEAL CRACKS.

TO

ONL

COL

TO

CLEAN EXTERIOR LIGHTING

{FIXTURE AND LENS).

REMOVE FIXTURE (TO

CLEAN) ONLY AS

NECESSARY

PAI NT EXTERIOR DOORS, FRAMES,

AND LOUVERS {STEEL ONLY);

COL OR TO MATCH MEDIUM BRONZE,

EQ. USE A RUST INHIBITOROR

PRI

LOU

MER ON METAL DOORS, FRAMES,

VERS, AND OVERHANGS. - SEE

"1DE AND INSTALL NOTE. PRO

\_CL

RE

PE

EANING, PAINT AND/OR

PAIRS TO INCLUDE

NTHOUSES ON ROOF.

REMOVE RUST & GRIME

FROM OVERHANGS AND/OR r OTHER METAL SURFACES

- WINDOWS, DOOR

FRAMES, ETC.

APPLY ANTI-RUST

INHIBITOR PRIMER AND

PAINT AT EXPOSED STEEL

BEAMS AT SECOND LEVEL.

RE MOVE MOLD, DIRT, MIUDEW

D/OR ALGAE FROMAN

BU ILDING EXTERIOR SURFACES

ALL WALLS (BRICK, EIFS,

LI), \\1NDOWS, DOORS,

LIVERS, LIGHTS, SIGNS,

OEWALKS, AND PENTHOUSES

�M

LO

SI

ON

WA

ROOF, INCLUDING SCREEN

LLS, TRASH PAD SCREEN

LLS, BOLLARDS, AND

RROUNDING SMOKE BREAK

'W'NINGS IN THE AREA.

WA

SU

A

I'--- REMOVE DIRT FROM

LIGHT FIXTURES

{FIXTURE AND LENS).

REMOVE FIXTURE (TO

CLEAN) ONLY AS

NECESSARY

*CONTRACTOR TO FIELD VERIFY

ALL DIMENSIONS AND CONDITIONS.*

6 7

9 1 0

GEIERAL NOTES

1. IT IS RECOMMENDED THAT THE CONTRACTOR FJELD VERIFY ALL

EXISTING CONDITIONS, AND DIMENSIONS, PRIOR TO BID AND START OF

CONSTRUCTION. NOTIFY CONTRACTING OFFICER OF ANY CONDlllONS

THAT COULD AFFECT THE SUCCESSFUL COMPLETION OF THE WORK AS

DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE ONLY - ACTUAL

DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSTRUCTION

DEBRIS DURING CONSTRUCTION.

3. CONTRACTOR SHALL PROTECT BUILDING, AND AREA AROUND

BUILDING, FROM DAMAGE. SHOULD DAMAGE OCCUR, CONTRACTOR

SHALL REPAIR/REPLACE DAMAGED ITEM TO MATCH PRE-DAMAGED

STATE, AS APPROVED BY THE CONTRACTING OFFICER.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL CONTRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF THERE ARE DIFFERING CONDITIONS IN THE FJELD FROM THE SOW,

SPECIFICATIONS, AND OR DRAWINGS CONTRACTOR MUST CONTACT THE

CONTRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT,

ELECTRONICS AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR

TO WORK.

CONSTRUC110N Mui ES

PROVIDE SERVICES TO CLEAN, REPAIR, AND REPAINT All EXTERIOR

SURFACES FOR BUILDING 4330.

PRIOR TO PRESSURE WASHING, VERIFY AND REMOVE LOOSE AND

SPALLING MATERIAL FROM OVERHANG/SOFFIT, AND REPAIR. REMOVE

RUST FROM EXISTING METAL SURFACES AND APPLY RUST INHIBITOR

PRIMER TO METAL SURFACES. PATCH AS STATED IN THE SOW.

REMOVE DIRT, GRIME, MILDEW, MOLD AND/OR ALGAE FROM THE

BUILDING'S EXTERIOR SURFACES. CLEAN WALLS, FASCIA, DOORS,

WINDOWS, LOUVERS, OVERHANGS/SOFFlTS, LIGHT FIXTURES, ROOF TRIM, SIGNAGE, DOOR LANDINGS, PENTHOUSES ON ROOF, INCLUDING SCREEN

WALLS, TRASH PAD SCREEN WALLS, BOLLARDS, AND SURROUNDING

SMOKE BREAK AWNINGS IN THE AREA.

CLEAN LIGHT FIXTURES AND LENS. REMOVE FIXTURE AS REQUIRED TO

CLEAN. VERIFY WORKING AND NON WORKING LIGHTS PRIOR TO WORK.

REMOVE RUST, GRIME AND PEELING PAINT FROM OVERHANGS AND

OTHER METAL SURFACES.

CLEAN WINDOWS, DOORS, AND DOOR FRAMES AFTER RUST AND GRIME

REMOVAL.

REMOVE AND REPLACE JOINT SEALANT AND BACKER ROD.

REPAIR DAMAGE TO EIFS WALL SURFACES. MATCH SURROUNDING

FINISHES AND COLOR.

CLEAN EXTERIOR LOUVERS.

PRESSURE WASH EXTERIOR SURFACE WITH WATER ONLY. USE CARE

TO PREVENT DAMAGE, OR FURTHER DAMAGE FROM OCCURRING.

ENSURE THE PROPER WATER PRESSURE IS USED FOR EACH MATERIAL

SPRAYED/CLEANED, ACCORDING TO INDUSTRY SlOS.

PAINT HM DOOR, FRAMES AND LOUVERS, COLOR TO MATCH EXISTING.

APPLY RUST INHIBITOR PRIMER ALL HOLLOW METAL SURFACES.

BENJAMIN MOORE ULTRA SPEC 500/LATEX/HIGH GLOSS, OR EQ.

*DO NOT PAINT ALUMINUM.

PAINT ALL STUCCO/EIFS WALLS. MATCH EXISTING FINISH AND PAINT.

PAINT BOLLARDS: PAINT COLOR: SAFETY YELLOW.

Rat15k:iN PAre

AR 1$1X,ATJON ..¥P TRANINE:i at..fMW

KEESLER AIR FORCE BASE

O'FIC.f. OF c;.ML ENE:i11ti:R$

M® □ ITTl�® □ ITTl �m®IT' □@[l' CC@®� □ ITTlij �,��®M ���®® [}-0��� C ���1

SllMITTED:

(c.hief of '-ontracts Pesign)

A. MARASCA

DE51E'll\6r. aE!,KED;

L. ASHLEY G. REED

(c.hiel of Engineering)

G.REED"""'

VARIES

- PATE: f'l¼E(.T �:

L. ASHLEY

29 JULY 2020 MAHG 13-1002

Bldg. 4331 -Allee Hall [;RAWNE';I N.MrlER::

A1.4

� 6 a- 7

1 0

G

F

E

D

C

B

A

1557824398E Text Box 24'-0"

D

L

C

B

A

1 2

AC AB AA

I

V

.JI!. �I 11 I

\__ REMOVE LEAD BASED PAINT FlROM RAILING

PER BASE REGULATIONS, SEE SOW. PREPARE

FOR PRIME AND PAINT. PRIME AND PAINT.

2A A 1.5

A

1A A1 .0

NORTH ELEVATION

SCALE: 1 /8" = 1'-0"

B C cd�;�RACTI�

I

□�PRI Al : ND

PAI OOR.

I

I I

L REMOVE LEAD BASED PAINT FROM RAILING

AND DOOR FRAME PER BASE REGULATIONS,

SEE SOW. PREPARE FOR PRIME AND PAINT. PRIME ,

PRIME AND PAINT.

SOUTH ELEVATION

SCALE: 1 /8" = 1 '-0"

r, � 5

A1 .5

R

KEYPLAN - EXISTING

SCALE: 1 "=30' -0"

Q p

J

REMOVE LEAD BASED PAINT FROM RAILING

PER BASE REGULATIONS, SEE SOW.

PRIME AND PAINT.

2B NORTH ELEVATION

A1 .5 SCALE: 1 /8"=1'-0"

J

[jl\

• Ci2

REMOVE LEAD BASED PAINT FROM RAILING --"'..,.

PER BASE REGULATIONS, SEE SOW. PREPARE

FOR, AND PRIME AND PAINT.

1B SOUTH ELEVATION

A1.0 SCALE: 1/8"=1'-0"

2C

1.5 w5

K

� 5

L

MOVE LEAD BASE Al

OM DOOR FRAM ·· -

K J

,Si��I I

L

REMOVE LEAD BASED PAINT FlROM RAILING

PER BASE REGULATIONS, SEE SOW.

PRIME AND PAINT.

2C

A 1.5

M

, •• 'II :

NORTH ELEVATION

SCALE: 1 /8"=1'-0"

:[j n:1::r w

':I

I n o[j[j[j[jt

II L

0 L

II L

p I I

1C p

I

A1.0

6 7

4it 5

H

Ci2

CONTRACTING

Q R lluuuull I

I I

I I

I I

I I

I I

I I

I I

I I

I I '

IOI

' I

-11I

SOUTH ELEVATION

SCALE: 1/8"=1'-0"

6 7

C B

I I

IL REMOVE LEAD BASED PAINT FROM RAILING

AND DOOR FRAMES PER BASE REGULATIONS,

SEE SOW. PRIME AND PAINT.

2D A 1.5

AA

NORTH ELEVATION

SCALE: 1/8"=1'-0"

AB

PRI�:: D----,i,-

PAIN ICOR.

A

I

AC

I

I -....� Fr----i==='='=='========'=='='====='==="='i,==�!,,,._

"91!

..._ -....1,.1

I I II \ / 7-

REMOVE LEAD BASED PAINT FROM RAILING �

AND DOOR FRAME PER BASE REGULATIONS,

SEE SOW. PRIME AND PAINT.

1D SOUTH ELEVATION

A1.0 SCALE: 1/8"=1'-0"

9 1 0

GENBW.NOlES

1. CONlRACTOR TO FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BID AND START OF CONSlRUCTION. NOTIFY CONlRACTING OFFICER OF ANY CONDITIONS DElRIMENTAL TO THE COMPLETION OF

THE WORK AS DESIGNED. DRAWINGS/DETAILS ARE FOR REFERENCE

ONLY - ACTUAL DETAILS MAY VARY.

2. PROTECT ALL FIRE ALARM COMPONENTS, HVAC GRILLS, AND OTHER

EQUIPMENT OR FINISHES FROM DUST, PAINT, AND CONSlRUCTION DEBRIS DURING CONSlRUCTION.

3. CONlRACTOR WILL REPLACE OR CLEAN IN PLACE ANY DAMAGED OR

CONTAMINATED ITEMS.

4. CONFINE ALL WORK TO SPECIFIC AREAS AS DESIGNATED IN THE

SCOPE OF WORK AND SCHEDULE.

5. ALL MATERIALS TO BE DEMOLISHED SHALL BE REMOVED FROM THE

SITE AND DISPOSED OF OFF-SITE IN A LEGAL LANDFILL. CONlRACTOR

IS NOT ALLOWED TO STOCKPILE DEMOLITION MATERIALS ON SITE; ALL

MATERIALS TO BE REMOVED IN A TIMELY FASHION.

6. ALL REMAINING/EXISTING AREAS SHALL BE CLEANED.

7. IF THERE ARE DIFFERING CONDITIONS IN THE FIELD FROM THE SOW,

SPECIFICATIONS, AND OR DRAWINGS CONlRACTOR MUST CONTACT THE CONlRACTING OFFICER IMMEDIATELY PRIOR TO PROCEEDING WITH ANY

WORK.

8. GOVERNMENT TO REMOVE ALL FURNITURE, EQUIPMENT, ELEClRONICS

AND PERSONAL ITEMS FROM WALLS AND SPACES PRIOR TO WORK.

Rat15k:iN PAre

AR 1$1X,ATJON ..¥P TRANINE:i at..fMW

KEESLER AIR FORCE BASE

O'FIC.f. OF c;.ML ENE:i11ti:R$ rM® □[l'i)�® □[l'i) �bK�®[f' □@[l' (C:@®� □[l'i]@ �w��®ITilil

(C:@lli)1t[l'@l©1t□llilij C �(S)(Q)/5) SllMITTED:

(c.hief of '-ontracts Pesign)

A. MARASCA

DE51E'll\6r. aE!,KED;

L. ASHLEY G. REED

(c.hiel of Engineering)

G.REED

VARIES

L.ASHLEY

PATE: f'l¼E(.T �:

29 JULY 2020 MAHG 13-1002

Bldg. 4605 - Contracting [;RAWNE';I N.MrlER::

A1.5

� 7 a- 7

1 0

G

F

E

D

C

B

A

File details come from the government source that posted it. Updated .