FA301018R0011A0004.pdf

PDF 123 KB Posted

Attached to
Keesler AFB SABER Federal contract opportunity
Solicitation number
FA301018R0011
Issued by
Department of the Air Force Air Education and Training Command

About this file

Amendment 0004

View the file

Other files for this federal contract opportunity

Other files attached to Keesler AFB SABER, newest first.
File Type Posted
MAHG161002_Recycle_Center_Phase_2_SOW_revD.pdf PDF
FA301018R0011A5.pdf PDF
MAHG161002_Addendum_2.pdf PDF
Atch5_MAHG161002_sow_RevC.pdf PDF
MAHG161002_ADDENDUM_1.pdf PDF
FA301018R0011A0003.pdf PDF
FA301018R0011A0002.pdf PDF
FA301018R0011A0001.pdf PDF
18R0011_SV_SignIn.pdf PDF
Atch2_MS180141_Building.pdf PDF
Atch7_MAHG161002_ALT1_Dwgs.pdf PDF
Attachment_1__SGSOW.pdf PDF
Atch6_MAHG161002__Dwgs.pdf PDF
Atch8_MAHG161002_Mechanical_Specs.pdf PDF
Atch5__MAHG161002_SOW.pdf PDF
Atch4_MS180237_Highway.pdf PDF
FA301018R0011.pdf PDF
Attachment_11_PPQ.pdf PDF
Atch3_MS180155_Heavy.pdf PDF
Attachment_10_PP_Reference_List.pdf PDF
Atch_9_AF_Form_66.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

To provide answ ers to offeror questions, add Addendum 1 and replace Attachment 5, Sample Project MAHG16-1002 SOW w ith a revised version.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 4

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 06-Apr-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X FA301018R0011

X 9B. DATED (SEE ITEM 11)

08-Mar-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

06-Apr-2018

CODE

81ST CONTRACTING SQUADRON

DONALD KINSMAN

500 FISHER ST, BLDG 0701, RM 202G

KEESLER AFB MS 39534

FA3010 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

FA301018R0011

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

QUESTIONS AND ANSWERS

MAHG161002 Questions and Answers April 6, 2018

1. From the statement of work it appears the contractors will be installing an additional electrical service on building 4002 for the recycle equipment. NEC article 230.2 typically only permits one electrical service per build or structure unless permitted in articles

230. (A) Through (D). Does service meet NEC Article 230.B? Also if the second service is installed permeant plagues will need to be installed on the new service and existing service to meet NEC article 230. (E). Will this plagues be required? In addition does KAFB fire department have any issue or requirement for building with multiple services?

Add labeling according to the NEC. See Addendum 1.

2. In the statement of work is call for a NEMA 1 disconnects to be installed in the inside the exiting building for the new service. If the building is going two different electrical service to meet the NEC the new disconnect for the new service should be located on the outside of the building as a means of disconnect to remove power from the building in the event of an emergency. Does the disconnect need to be change to a 200amp 240v NEMA 3R “service entrance” rate fusible disconnect switch with a neutral bar and moved to the north outside wall of the building 4002?

See Addendum 1.

3. In the statement of work is calling for 4‐3/0 THHN + 1‐3/0 GD to be installed from the transformer to the new disconnect. Typically you would not pull a full size ground conductor in with your service entrance conductors from the transformer to the disconnect. The ground conductor would start and the service entrance disconnect were the ground rod is driven. Is the 3/0 ground conductor from the transformer required? See Addendum 1.

4. The new service entrance disconnect will require a ¾’’x10’ copper clad ground rod with a #4 ground conductor from the ground rod to the service entrance disconnect 1’’ conduit GRC conduit and to bond neutral to ground at the first means of disconnect which would be the new safety switch. Will this be required as part of this project? See Addendum 1.

5. The statement of work is calling for THHN insulated conductor to be used. THHN is use in dry and damp locations. Underground conduit a typically classified as wet locations. Can XHHW insulated conductor be used there are approved for dry and damp and wet location? See Addendum 1.

6. In the statement of work is calling for 3 phase to be installed from the disconnect switch to the new panelboard in a 2” conduit. Should this be 4‐3/0 THHN +1‐#6 green GD in 2 ½’ conduits? See Addendum 1.

7. Instead of trenching the 500 foot from the existing transform through paved area of building 4004.

Can the contractor road bore in the 2 ½’’ PVC conduit from the existing transformer to building 4002? It would be approximately 460 feet of road bore and 40 feet of trenching required for this project. Also can two (2) 24’’x24’’x24’’ in ground Quazite junction boxes be install for pull point?

One in ground j‐box 10’ to 15’ on the south side of the transformer and the other 10’ off the north side of building 4002 in the grass area. See Addendum 1.

8. Drawing A1.0 Detail 10 for the blue max‐packer horizontal baler is showing a 25kv 3phase 25kva 208v primary and 480v secondary transformer being relocated to provide the 480v power for this equipment. In the SOW is calling for this equipment to be feed from 3 pole 30amp breaker with 4‐ #10 + 1‐#10 GN which is the 208v primary side of side transformer. Is this the correct size breaker and conductors for primary side of this transformer? Also is a neutral conductor required?

In order to get the 27 amp of 480v on the secondary side of the transformer required for this equipment by reveres feeding the 25kva transformer the 208v primary side of the transformer, the over current devices and conductors need to be figured at the at the 208v primary side amperage of the transformer which is 69.4 amp.

The breaker size for this transformer should be 125%of the amperage (69.4x1.25=86.75) a 3pole 90amp breaker and the conductor size would be 3‐#3+1‐#6 GD 1 ¼’’ conduit. The 480v secondary side would be 3‐ #10+1‐#10 GD in a ¾’’ conduit. Typically with this type of transformer is not set up for and 480v neutral connection unless the transformer is set up with a H0 connection point.

9. Drawing A1.0 Detail 10 for the shedder and green vertical baler is showing the equipment drawing

28amp. The SOW is calling for 3 pole 30amp breaker for be installed in the new panelboard. The 30amp breakers being installed are over the 80% rating of the new circuit breaker. Are these the correct size circuit breaker?

Circuit breaker are typically not load more than 80% of their rating in which a 30amp would not be load more than 24 amp. With the in rush current from the motor starting on the equipment could possible cause the 30amp breaker to trip. NEC allows you to go to the next size breaker which would be 35amp.

10. Are there any additional fire alarm requirements for the recycle center relocation area?

No additional Fire Alarm requirements are required

SECTION J - LIST OF DOCUMENTS, EXHIBITS AND OTHER ATTACHMENTS

The following have been modified:

LIST OF ATTACHMENTS

Document Type Description Pages Date Attachment 1 General Statement of Work (SGSOW) 48 12 Feb 18 Attachment 2 Wage Determination MS180141 5 5 Jan 18 Attachment 3 Wage Determination MS180155 4 5 Jan 18 Attachment 4 Wage Determination MS180237 5 5 Jan 18 Attachment 5 Sample Project MAHG16-1002 SOW (RevC) 23 4 Apr 18 Attachment 6 Sample Project MAHG16-1002 Drawings 2 22 Dec 17 Attachment 7 Sample Project MAHG16-1002 Drawings 2 28 Dec 17 (Alt I) Attachment 8 Sample Project MAHG16-1002 129 4 Aug 17 Mechanical Specifications Attachment 9 Sample Project MAHG16-1002 AF Form 1 Undated 66 Schedule of Material Submittals Attachment 10 Past Performance Reference List 1 Undated Attachment 11 Past Performance Questionnaire 2 Undated Attachment 12 Addendum 1 1 6 Apr 18

(End of Summary of Changes)