I was asked for drawings of the building. These drawings were created for previous work. Please note any directions on these drawings DO NOT APPLY to the work currently being done. This drawing is only as a refrence for physical demensions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| thumbnail3.jpg | JPG image | |
| thumbnail4.jpg | JPG image | |
| thumbnail2.jpg | JPG image | |
| thumbnail.jpg | JPG image | |
| WD_Middlesex_county.docx | DOCX document | |
| FA2835-17-R-0032_Solicitation.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1
A-1
A-1
A-1
A-1
NEW VINYL LOUVER
PORTION. PROVIDE
BLANK OFF UNUSED
LOUVER REMAIN
EXIST, ALUMINUM
1" RIGID INSULATION
NEW VINYL SIDING ON
AND GUTTER
INSTALL NEW ALUM FASCIA SOFFIT
GRADE
INSTALL NEW
REMOVE EXIST &
DOWNSPOUTS
NEW ALUM GUTTER
ALUM DOWNSPOUT
EXIST GRADE
TO BE REPAIRED (TYP)
INSULATED ALUM DOORS
SHINGLES
ROOF
COMPOSITE
EACH DOORWAY
CONC PAD @
COMPOSITE ROOF SHINGLES
DRIP EDGE, FELT & SHINGLES
INSTALL NEW ICE & WATER SHIELD,
EACH OPENING
DOOR LEVEL w/INTERIOR SURFACE @
NEW BIT. CONC PAD @ EACH EXT
DOWNSPOUT
NEW
NOTE:
NOTES, TYPICAL FOR ALL ELEVATIONS.
NEW GUTTERS
SCALE: 1/8"=1'-0"
EAST ELEVATION1
SCALE: 1/8"=1'-0"
SOUTH ELEVATION2
SCALE: 1/8"=1'-0"
WEST ELEVATION3
SCALE: 1/8"=1'-0"
NORTH ELEVATION4 TO REMAIN
EXIST CONC STAIR
PEAKS, RAKES & TRANSITIONS
@ ALL EAVE RIDGES,
BITUTHENE PROTECTION MEMBRANE
(TYP)
ALL DOORS & WINDOWS
VINYL"J" TRIM CASING @
FOUNDATION WALL (TYP)
BOARDS (TYP)
VINYL 4" CORNER
(TYP)
FOUNDATION WALL
TO REMAIN (TYP)
INSULATED ALUM WINDOWS
BOARD (TYP)
NEW CORNER
SHEATHING
OVER EXIST/REPAIRED
APPLIED
3/8" RIGID INSULATION
NEW 4" VINYL SIDING ON
FIRST FLOOR
EL 139.3'
FIRST FLOOR
EL 139.3'
FIRST FLOOR
EL 139.3'
A-3
(TYP)
A-3
(TYP)
A-1
A-1
A-1
A-1
ALUM DOOR
NEW INSULATED
JOISTS
w/ NEW WOOD HDR @
2 COURSES 4" CMU
FRAMING AND INSTALL
REMOVE EXIST WOOD
JOISTS
w/ NEW WOOD HDR @
2 COURSES 4" CMU
FRAMING AND INSTALL
REMOVE EXIST WOOD
NEW VINYL LOUVER
PORTION. PROVIDE
BLANK OFF UNUSED
LOUVER REMAIN
EXIST, ALUMINUM
NEW VINYL LOUVER
PORTION. PROVIDE
BLANK OFF UNUSED
LOUVER REMAIN
EXIST, ALUMINUM
HM DOOR
NEW INSUL.
INFILL LOUVER OPENING
INFILL @ NEW DUCT OPENING
INFILL WINDOW OPENING
EXIST WINDOW
EXIST WINDOW
24"x48" DUCT OPENING
FROM NORTH ELEV
CONN. & DRAIN
RELOCATE FIRE DEPT.
(30'-0" OC MAX)
ALL CORNERS
NEW DOWNSPOUTS @
REV DATE
PROJECT NUMBER
SHEET OF
ATTACHMENT 4
SOLICITATION NO.
PROJECT MANAGER
DESIGNED BY
DRAWN BY
DATE
66th SUPPORT GROUP / CECE
DEPARTMENT OF THE AIR FORCE
BASE CIVIL ENGINEER SQUADRON
HANSCOM AFB, MA 01731
E
AI
R
FORCE MAT R
I
ELCOMMAND ELECTRONIC SYSTEMSCE
NT
E R
Property of the United States Air Force - For Official Use Only
SEPTEMBER 22, 2006
SECURITY POLICE
FIRE DEPARTMENT
COMMUNICATIONS
USER
ENVIRONMENTAL
SAFETY
HANSCOM APPROVAL
MXRD 05-0031
BUILDING 1999
AIR FORCE MATERIEL COMMAND
DESCRIPTION DRAWN APPROVED
DM
DM
SMH
EXTERIOR ELEVATIONS AND DETAILS
- A-3
1/8"=1'-0"
20'15'10'5'0
2'1'0 10'9'8'7'6'5'4'3'
1/4"=1'-0"
3'2'1'0
3/4"=1'-0"
AS-BUILT
THIS DRAWING
SECTION 5 & 6
THIS DRAWING
SECTION 5 & 6
HRG
LEVEL
GROUND
DRAIN PIPE
EXCAVATION LEVEL
BLOCK SYSTEM
INTERLOCKING
GRAVEL
GRADED
C-2
A
SCALE: NTS
UNI-LOCK WALL
C-2
SCALE: NTS
BITUMINOUS CONCRETE WALK SECTION
GRADED CRUSHED AGGREGATE BASE COURSE
GRADE
FINISH
SUBGRADE
COMPACTED
8"
3"
VARIES
TYPE I-1
TOP COURSE
BITUMINOUS CONC.
1" CLASS I
TYPE-1
BINDER COURSE
BITUMINOUS CONC.
2" CLASS I
REFERENCE FROM SHT. C2
REFERENCE FROM SHT. C2
(TYP)
1'-0"
(TYP)
1'-0"
1'-0"
1'-0"
FINISH GRADE
SCALE: 3/4"=1'-0"
CONCRETE STAIRS
A-1
1/2" EXP JOINT
REINF CONC STEP
STAIR NOSING
PAVEMENT
FLUSH w/
AT LANDING
CEM CONC
@ 12" OC
#4 REBAR
METAL NOSING & ANCHOR
2" CL @ ENDS
EACH WAY
#4 REBAR @ 12" OC
COURSE
BASE
AGGREGATE
6"
" STEEL HANDRAIL2
1'-1"
1'-1"
5 1/2"
"2
5 1/2"
SCALE: 3/4"=1'-0"
CENTER HANDRAIL @ CONC. STEPS
A-1
CL
CL BOTTOM STEP
NON-SHRINK GROUT
SET POSTS IN
(TYP)
RADIUS
4" OD
JOINTS
HANDRAIL w/ WELDED
1 1/2" STEEL PIPE