Requirements for Signal Generators and Spectrum Analyzers

1. Keysight Technologies N9010A-526 Spectrum Analyzer, or equivalent

a. Quantity: Four (4)

b. RF Input:

i. Frequency Range: 10 MHz to 26.5 GHz

ii. Input Attenuator: 0 dB to 60 dB range, 10-dB steps

iii. Interface: 50-ohm Coax Connector (SMA or N-Type)

c. Measurement Bandwidths:

i. Resolution Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps)

ii. Video Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps)

d. Measurement Functions:

i. Analysis Bandwidth Up to 10 MHz

ii. Integrated Channel Power Measurements

iii. Occupied Bandwidth

e. Display Functions:

i. Log magnitude scale in at least 1/2/5/10 dB/division steps

ii. Multiple independent traces (write, max hold, min hold, view, blank)

iii. Multiple independent markers (absolute, relative, trace selective)

f. Hard Drive Storage:

i. Removable Solid-State Hard Drive (80 GB)

ii. Option N9010A-SSD on Keysight N9010A-526

g. Data Interface:

i. Ethernet Interface (1000 Base-T), RJ-45 Connector

ii. SNMP Control Supported

h. Electrical & Mechanical:

i. 4U Rack-Mount (max)

ii. Rack-Mount Kit Included (Option N9010A-1CP on Keysight N9010A-526)

iii. 120-V AC Prime Power

2. Keysight Technologies N9064A-1TP, or equivalent

a. Quantity: One (1)

b. Vector Signal Analysis Measurement License:

i. Supported by Rack-Mount Spectrum Analyzer listed in Item #2

ii. FFT-based spectrum analysis and time-domain analysis

iii. Spectrum analysis: center frequency, span, occupied BW, band power, markers

iv. Time-domain analysis: amplitude, markers, CCDF, Error Vector Magnitude

v. Digital modulation analysis for BPSK, QPSK, 16QAM

vi. Perpetual license, single license transportable between spectrum analyzers

3. Keysight Technologies N5172B-503 Signal Generator, or equivalent

a. Quantity: Three (3)

b. RF Output:

i. Frequency Range: 9 kHz to 3 GHz (min), 1-Hz resolution (max)

ii. Output Power: -100 dBm to +13 dBm (min), 0.1-dB resolution (max)

c. Interface: 50-ohm Coax Connector (SMA or N-Type)

d. Sweep Function:

i. Stepped or list sweep function

ii. Dwell times: 0.1 ms to 100 s

e. Analog Modulation Options (Option N5172B-UNT on Keysight N5172B):

i. Amplitude Modulation (AM) – up to 1 MHz modulation BW

ii. Frequency Modulation (FM) – up to 1 MHz modulation BW

iii. Phase Modulation (PM) – up to 1 MHz modulation BW

iv. Multiple simultaneous modulation options possible

f. Multi-Function Modulation Options (Option N5172B-303 on Keysight N5172B):

i. Waveforms: sine, square, ramp, triangle, pulse, noise

ii. Modulation rates: 1 Hz to 1 MHz

g. Pulse Modulation Option (Option N5172B-UNW on Keysight N5172B):

i. Pulse width down to 2 s

ii. Pulse period down to 20 s (Repetition rate up to 500 kHz)

h. Multi-Tone Function Option (Option N5172B-430 on Keysight N5172B):

i. Number of tones: Up to 64

ii. 120 MHz total bandwidth (all carriers with +/-60 MHz)

iii. Carriers / tones can be independently turned on or off

i. Custom Digital Modulation Option (Option N5172B-431 on Keysight N5172B):

i. Modulation Schemes: BPSK, QPSK, OQPSK, 8-PSK, 16-PSK, 16-QAM

ii. Modulation Rate: 1 ksps to 75 Msps

iii. Internal Random Data Source: PN9, PN11, PN15, PN20, PN23

iv. Multi-Carrier up to 100 carriers

j. Electrical & Mechanical:

i. 2U Rack-Mount (max)

ii. Rack-Mount Kit Included (Option 1CP004A for Keysight N5172B)

iii. 120-V AC Prime Power

4. Keysight Technologies N9917A Handheld FieldFox Microwave Analyzer, or equivalent

a. Quantity: One (1)

b. RF Input:

i. Frequency Range: 10 MHz to 18 GHz

ii. Interface: 50-ohm Coax Connector (SMA or N-Type)

c. Display Functions:

i. Log magnitude scale in at least 1/2/5/10 dB/division steps

ii. Multiple independent traces (write, max hold, min hold, view, blank)

iii. Multiple independent markers (absolute, relative, trace selective)

d. Spectrum Analyzer (Option N9917A-233 for Keysight N9917A):

i. Support Spectrum Analyzer Measurements up to 18 GHz

ii. Resolution Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps)

iii. Video Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps)

iv. Internal Input Attenuator: 0 to 30 dB, 5-dB or 10-dB steps

v. Multiple independent traces (write, max hold, min hold, view, blank)

vi. Multiple independent markers (absolute, relative, trace selective)

e. Tracking Generator (Option N9917A-210 for Keysight N9917A):

i. Tracking Generator up to 18 GHz

ii. Output Power adjustable up to -10 dBm, 1-dB steps

iii. Functions: CW, CW Tracking

f. Two-Port S-Parameter Measurement (Option N9917A-211 for Keysight N9917A):

i. Calibrated Two-Port S-Parameter Measurements up to 18 GHz

ii. Time-domain gating supported

g. Built-In Power Meter (Option N9917A-310 for Keysight N9917A):

i. Built-In Power Meter for aggregate power measurements up to 18 GHz

ii. Channel Power Measurements supported up to 18 GHz (user-defined BW)

h. Pre-Amplifier (Option N9917A-235 for Keysight N9917A):

i. Pre-Amplifier across entire measurement range, up to 18 GHz

i. External Power Sensor Support (Option N9917A-302 for Keysight N9917A):

i. Support for an external USB average power sensor up to at least 18 GHz, such as Keysight U2000A or equivalent

j. Electrical & Mechanical:

i. Handheld Unit (less than ten pounds)

ii. Hard-Sided Carrying Case (Option N9910X-881 for Keysight N9917A)

iii. Spare Battery (Option N9910X-870 for Keysight N9917A)

iv. 120-V AC Power or Internal Battery

5. Keysight Technologies N9344C Handheld Spectrum Analyzer, or equivalent

a. Quantity: One (1)

b. RF Input:

i. Frequency Range: 10 MHz to 20 GHz

ii. Input Attenuator: 0 dB to 50 dB range, 5-dB or 10-dB steps

iii. Interface: 50-ohm Coax Connector (SMA or N-Type)

c. Measurement Bandwidths:

i. Resolution Bandwidth: 10 Hz to 3 MHz (with at least 1/3/10 steps)

ii. Video Bandwidth: 10 Hz to 3 MHz (with at least 1/3/10 steps)

d. Display Functions:

i. Log magnitude scale in at least 1/2/5/10 dB/division steps

ii. Multiple independent traces (write, max hold, min hold, view, blank)

iii. Multiple independent markers (absolute, relative)

e. Pre-Amplifier (Option N9344C-P20 for Keysight N9344C):

i. Pre-Amplifier across entire measurement range, up to 20 GHz

f. External Power Sensor Support (Option N9344C-PWM for Keysight N9344C):

i. Support for an external USB average power sensor up to at least 20 GHz, such as Keysight U2000A or equivalent

g. Security Features (Option N9344C-SEC for Keysight N9344C):

i. Erase user data memory partition

ii. Disable/enable LAN & USB ports with password

h. Electrical & Mechanical:

i. Handheld Unit (less than ten pounds)

ii. Hard-Sided Carrying Case (Option N9344C-1TC for Keysight N9344C)

iii. 120-V AC Power or Internal Battery

6. Keysight Technologies U2000A USB Average Power Sensor, or equivalent

a. Quantity: Two (2)

b. RF Input:

i. Frequency Range: 10 MHz to 18 GHz

ii. Power Range: -60 dBm to +20 dBm

iii. Interface: 50-ohm Coax Connector (SMA or N-Type)

c. Measurements:

i. Average Power Measurements

d. Interface:

i. USB Instrument Interface, Compatible with both Handheld Microwave Analyzer and Handheld Spectrum Analyzer instruments listed above in (3) and (4)

ii. Include 3m/10’ USB power sensor cable (Keysight U2031B or equivalent), compatible with power sensor

7. Keysight Technologies 85518A N-Type Calibration Kit, 0-18 GHz, or equivalent

a. Quantity: One (1)

b. RF Input:

i. Frequency Range: 0 MHz to 18 GHz

ii. Interface: 50-ohm Coax Connector (N-Type)

c. Calibration Standards:

i. Short

ii. Open

iii. Load (50-ohm)

iv. Through

d. Calibration Data:

i. Specifications for each calibration standard for entry into Keysight Technologies N9917A Microwave Analyzer