Text version
FA2550-15-T-2013
Section SF 1449 - CONTINUATION SHEET
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 4 |
| Each |
Keysight Technologies N9010A-503 Spectru
FFP
1.
Keysight Technologies N9010A-503 Spectrum Analyzer, or equal a.
Quantity: Four (4) b.
RF Input:
i.
Frequency Range: 10 MHz to 3 GHz ii.
Input Attenuator: 0 dB to 60 dB range, 10-dB steps iii.
Interface: 50-ohm Coax Connector (SMA or N-Type) c.
Measurement Bandwidths:
i.
Resolution Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps) ii.
Video Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps) d.
Measurement Functions:
i.
Analysis Bandwidth Up to 10 MHz ii.
Integrated Channel Power Measurements iii.
Occupied Bandwidth e.
Display Functions:
i.
Log magnitude scale in at least 1/2/5/10 dB/division steps ii.
Multiple independent traces (write, max hold, min hold, view, blank) iii.
Multiple independent markers (absolute, relative, trace selective) f.
Hard Drive Storage:
i.
Removable Solid-State Hard Drive (80 GB) ii.
Option N9010A-SSD on Keysight N9010A-503 g.
Data Interface:
i.
Ethernet Interface (1000 Base-T), RJ-45 Connector ii.
SNMP Control Supported h.
Electrical & Mechanical:
i.
4U Rack-Mount (max) ii.
Rack-Mount Kit Included (Option N9010A-1CP on Keysight N9010A-503) iii.
120-V AC Prime Power
FOB: Destination
PURCHASE REQUEST NUMBER: F3RTCL5148A002
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Keysight Technologies N9064A-1TP, or equ
2.
Keysight Technologies N9064A-1TP, or equal a.
Quantity: One (1) b.
Vector Signal Analysis Measurement License:
i.
Supported by Rack-Mount Spectrum Analyzer listed in Item #2 ii.
FFT-based spectrum analysis and time-domain analysis iii.
Spectrum analysis: center frequency, span, occupied BW, band power, markers iv.
Time-domain analysis: amplitude, markers, CCDF, Error Vector Magnitude v.
Digital modulation analysis for BPSK, QPSK, 16QAM vi.
Perpetual license, single license transportable between spectrum analyzers
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 3 |
| Each |
Keysight Technologies N5172B-503 Signal
3.
Keysight Technologies N5172B-503 Signal Generator, or equal a.
Quantity: Two (2) b.
RF Output:
i.
Frequency Range: 9 kHz to 3 GHz (min), 1-Hz resolution (max) ii.
Output Power: -100 dBm to +13 dBm (min), 0.1-dB resolution (max) c.
Interface: 50-ohm Coax Connector (SMA or N-Type) d.
Sweep Function:
i.
Stepped or list sweep function ii.
Dwell times: 0.1 ms to 100 s e.
Analog Modulation Options (Option N5172B-UNT on Keysight N5172B):
i.
Amplitude Modulation (AM) – up to 1 MHz modulation BW ii.
Frequency Modulation (FM) – up to 1 MHz modulation BW iii.
Phase Modulation (PM) – up to 1 MHz modulation BW iv.
Multiple simultaneous modulation options possible f.
Internal Multi-Function Modulation Options (Option N5172B-303 on Keysight N5172B):
i.
Waveforms: sine, square, ramp, triangle, pulse, noise ii.
Modulation rates: 1 Hz to 1 MHz g.
Pulse Modulation Option (Option N5172B-UNW on Keysight N5172B):
i.
Pulse width down to 2 ?s ii.
Pulse period down to 20 ?s (Repetition rate up to 500 kHz) h.
Multi-Tone Function Option (Option N5172B-430 on Keysight N5172B):
i.
Number of tones: Up to 64 ii.
120 MHz total bandwidth (all carriers with +/-60 MHz) iii.
Carriers / tones can be independently turned on or off i.
Custom Digital Modulation Option (Option N5172B-431 on Keysight N5172B):
i.
Modulation Schemes: BPSK, QPSK, OQPSK, 8-PSK, 16-PSK, 16-QAM ii.
Modulation Rate: 1 ksps to 75 Msps iii.
Internal Random Data Source: PN9, PN11, PN15, PN20, PN23 iv.
Multi-Carrier up to 100 carriers j.
Arbitrary Waveform Generator (Option N5172B-653 on Keysight N5172B):
i.
Modulation Bandwidth: Up to 60 MHz ii.
Sample Rate: Up to 75 MSa/s iii.
Playback Memory: 32 MSamples (min) k.
Real-Time Baseband Generator (Option N5172B-660 on Keysight N5172B):
i.
Real-Time I/Q Baseband Generation ii.
Support DVB-S/S2 Video Signals l.
Upgrade Baseband Memory (Option N5172B-022 on Keysight N5172B):
i.
Playback Memory: 512 MSamples m.
DVB-S/S2 Option (Option N7623B-GFP on Keysight N5172B):
i.
Create fully-coded DVB-S (Viterbi+R/S) and DVB-S2 (LDPC+BCH) signals ii.
Data: Random data, Color Bars, MPEG-2 TS file n.
Perpetual Fixed License Electrical & Mechanical:
i.
2U Rack-Mount (max) ii.
Rack-Mount Kit Included (Option 1CP004A for Keysight N5172B) iii.
120-V AC Prime Power
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Keysight Technologies N9917A Handheld Fi
4.
Keysight Technologies N9917A Handheld FieldFox Microwave Analyzer, or equal a.
Quantity: One (1) b.
RF Input:
i.
Frequency Range: 10 MHz to 18 GHz ii.
Interface: 50-ohm Coax Connector (SMA or N-Type) c.
Display Functions:
i.
Log magnitude scale in at least 1/2/5/10 dB/division steps ii.
Multiple independent traces (write, max hold, min hold, view, blank) iii.
Multiple independent markers (absolute, relative, trace selective) d.
Spectrum Analyzer (Option N9917A-233 for Keysight N9917A):
i.
Support Spectrum Analyzer Measurements up to 18 GHz ii.
Resolution Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps) iii.
Video Bandwidth: 1 Hz to 3 MHz (with at least 1/3/10 steps) iv.
Internal Input Attenuator: 0 to 30 dB, 5-dB or 10-dB steps v.
Multiple independent traces (write, max hold, min hold, view, blank) vi.
Multiple independent markers (absolute, relative, trace selective) e.
Tracking Generator (Option N9917A-210 for Keysight N9917A):
i.
Tracking Generator up to 18 GHz ii.
Output Power adjustable up to -10 dBm, 1-dB steps iii.
Functions: CW, CW Tracking f.
Two-Port S-Parameter Measurement (Option N9917A-211 for Keysight N9917A):
i.
Calibrated Two-Port S-Parameter Measurements up to 18 GHz ii.
Time-domain gating supported g.
Built-In Power Meter (Option N9917A-310 for Keysight N9917A):
i.
Built-In Power Meter for aggregate power measurements up to 18 GHz ii.
Channel Power Measurements supported up to 18 GHz (user-defined BW) h.
Pre-Amplifier (Option N9917A-235 for Keysight N9917A):
i.
Pre-Amplifier across entire measurement range, up to 18 GHz i.
External Power Sensor Support (Option N9917A-302 for Keysight N9917A):
i.
Support for an external USB average power sensor up to at least 18 GHz, such as Keysight U2000A or equivalent j.
Electrical & Mechanical:
i.
Handheld Unit (less than ten pounds) ii.
120-V AC Power or Internal Battery
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
Keysight Technologies N9344C Handheld Sp
5.
Keysight Technologies N9344C Handheld Spectrum Analyzer, or equal a.
Quantity: One (1) b.
RF Input:
i.
Frequency Range: 10 MHz to 20 GHz ii.
Input Attenuator: 0 dB to 50 dB range, 5-dB or 10-dB steps iii.
Interface: 50-ohm Coax Connector (SMA or N-Type) c.
Measurement Bandwidths:
i.
Resolution Bandwidth: 10 Hz to 3 MHz (with at least 1/3/10 steps) ii.
Video Bandwidth: 10 Hz to 3 MHz (with at least 1/3/10 steps) d.
Display Functions:
i.
Log magnitude scale in at least 1/2/5/10 dB/division steps ii.
Multiple independent traces (write, max hold, min hold, view, blank) iii.
Multiple independent markers (absolute, relative) e.
Pre-Amplifier (Option N9344C-P20 for Keysight N9344C):
i.
Pre-Amplifier across entire measurement range, up to 20 GHz f.
External Power Sensor Support (Option N9344C-PWM for Keysight N9344C):
i.
Support for an external USB average power sensor up to at least 20 GHz, such as Keysight U2000A or equivalent g.
Security Features (Option N9344C-SEC for Keysight N9344C):
i.
Erase user data memory partition ii.
Disable/enable LAN & USB ports with password h.
Electrical & Mechanical:
i.
Handheld Unit (less than ten pounds) ii.
Hard-Sided Carrying Case (Option N9344C-1TC for Keysight N9344C) iii.
120-V AC Power or Internal Battery
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 2 |
| Each |
Keysight Technologies U2000A USB Average
6.
Keysight Technologies U2000A USB Average Power Sensor, or equal a.
Quantity: Two (2) b.
RF Input:
i.
Frequency Range: 10 MHz to 18 GHz ii.
Power Range: -60 dBm to +20 dBm iii.
Interface: 50-ohm Coax Connector (SMA or N-Type) c.
Measurements:
i.
Average Power Measurements d.
Interface:
i.
USB Instrument Interface, Compatible with both Handheld Microwave Analyzer and Handheld Spectrum Analyzer instruments listed above in (3) and (4) ii.
Include 3m/10’ USB power sensor cable (Keysight U2031B or equivalent), compatible with power sensor
NET AMT
| ITEM NO |
| SUPPLIES/SERVICES |
| QUANTITY |
| UNIT |
| UNIT PRICE |
| AMOUNT |
| 1 |
| Each |
7.
Keysight Technologies 85518A N-Type C
FFP
7.
Keysight Technologies 85518A N-Type Calibration Kit, 0-18 GHz, or equal a.
Quantity: One (1) b.
RF Input:
i.
Frequency Range: 0 MHz to 18 GHz ii.
Interface: 50-ohm Coax Connector (N-Type) c.
Calibration Standards:
i.
Short ii.
Open iii.
Load (50-ohm) iv.
Through d.
Calibration Data:
i.
Specifications for each calibration standard for entry into Keysight Technologies N9917A Microwave Analyzer
NET AMT