NEW PANEL
VOLTAGE (L-N): ENCLOSURE TYPE: NEMA 1
VOLTAGE (L-L): MOUNTING: RECESSED
PHASES, WIRES: 3PH, 4W AIC RATING (A):
200 A
CKT NO DESCRIPTION WIRE (AWG) TRIP
AMPS POLE
PHASE LOADS (VA)
POLE TRIP
AMPS
WIRE (AWG) DESCRIPTION CKT NO
A B C
43 44 45 400 400 46 47 1 400 400 48 49 400 400 50
51 400 400 1 20 EXIST WIREMOLD C1-76K (SEC1-20) 52
53 400 400 54
CONNECTED LOAD PHASE TOTALS (VA)
23922 22841 21862
CONNECTED LOAD
(VA) DEMAND FACTOR DEMAND LOAD (VA)
UPS EQUIPMENTS 20300
TOTAL: 73424 52275
LOAD (AMPS): 203.8 145.1
FEEDER: 4-3/0+#4G-2"C FROM EXISTING PANEL 'CLB-DD'
2#12+#12G-3/4"C
29000
CL1-D4
22000
MINIMUM BUS CAPACITY (AMPS): NOTES:
MAIN O.C. DEVICE (AMPS): 175 A
400 400
70%
55 400 1000 56 57 1 400 400 1 20 58 59 400 400 60
SPACE 1
SPACE 1
- 400
SPACE 1
- 400
79 - 800 80 81 - 600 82 83 - 300 84
- 400
1 20
1 20 1 20
1 20
EXIST RECEP C1-76J,K (SEC1-22)2#12+#12G-3/4"C
2#12+#12G-3/4"C
61 400 400 62 63 400 400 1 20 64 65 1000 400 66
67 1000 400 68 69 1 1000 400 1 20 70 71 - 400 72
1 20
1 20 1 20
1 20
20 1
2#12+#12G-3/4"C
SPARE - 20
SPARE
SPARE
SPACE
1 1500 1000 2
NEMA L6-30R IN COL A 30 2
1500 1000 4
5 1500 1000 6 7 1500 1000 8 9 1500 1000 10 11 1500 1000 12 13 1000 1000 14 15 1000 1000 16 17 1000 1000 18 19 1000 1000 20 21 22 23 1000 1000 24 25 1000 - 26 27 -
2 20 NEMA L6-20R COL C
29 - - 30 31 - 32 33 34 35 - - 36 37 2918 5404 38
39 AIR COMPRESSOR 40 3 2918 4323 3 100 EXIST PANEL 'CL1-D3A' 40
41 2918 5044 42
2#10+#10G-3/4"C
4#2+#8G-1-1/2"C
2#12+#12G-3/4"C
3#8+#8G-3/4"C
NEMA L6-30R IN COL B 30 22#10+#10G-3/4"C
NEMA L6-30R IN COL D 30 22#10+#10G-3/4"C
NEMA L6-20R IN COL A 20 22#12+#12G-3/4"C
NEMA L6-20R IN COL A 20 22#12+#12G-3/4"C
NEMA L6-20R IN COL A 20 22#12+#12G-3/4"C
NEMA L6-20R IN COL A 20 22#12+#12-3/4"C
SPACE - 2-
SPACE - 2-
2 20 NEMA L6-20R COL C2#12+#12G-3/4"C
2 20 NEMA L6-20R COL C2#12+#12G-3/4"C
2 20 NEMA L6-20R COL D2#12+#12G-3/4"C
2 20 NEMA L6-20R COL D2#12+#12G-3/4"C
2 20 NEMA L6-20R COL E2#12+#12G-3/4"C
2 20 SPARE-
2 20
2 20
SPARE-
SPARE-
DUPLEX RECEP COL C 15 12#12+#12G-3/4"C
DEPLEX RECEP COL A 20 12#12+#12G-3/4"C
DUPLEX RECEP COL C 152#12+#12G-3/4"C
DUPLEX RECEP COL C 152#12+#12G-3/4"C
DUPLEX RECEP COL C 152#12+#12G-3/4"C
DUPLEX RECEP COL C 152#12+#12G-3/4"C
DUPLEX RECEP COL C 152#12+#12G-3/4"C
DUPLEX RECEP COL D 152#12+#12G-3/4"C
DUPLEX RECEP COL D 152#12+#12G-3/4"C
DUPLEX RECEP COL E
REMISOL WORK STATION COL F
EXIST WIREMOLD FREEZER (SEC2-4)
2#12+#12G-3/4"C
EXIST WIREMOLD C1-76J (SEC1-18)2#12+#12G-3/4"C
1 20 EXIST WIREMOLD C1-76E,F,G (SEC1-19)2#12+#12G-3/4"C
1 20
1 20 EXIST RECEP C1-76E,F,G (SEC1-21)2#12+#12G-3/4"C
EXIST WIREMOLD C1-76E,F,G (SEC1-17)2#12+#12G-3/4"C
EXIST WIREMOLD C1-76H,M (SEC1-27)
EXIST WIREMOLD C1-76H,M (SEC1-29)
EXIST RECEP C1-76H,M (SEC1-31)
EXIST WIREMOLD C1-76L (SEC1-23)
EXIST WIREMOLD C1-76L (SEC1-25)
EXIST RECEP C1-76N,O (SEC1-24)
EXIST RECEP C1-76N,O (SEC1-26)
EXIST RECEP C1-76N (SEC1-42)
EXIST GFI RECEP C1-76L (SEC2-17)
EXIST RECEP C1-76N (SEC2-2)
EXIST RECEP C1-76L (SEC2-13)
EXIST RECEP C1-76M (SEC2-15)
EXIST RECEP WAX MACHINE (SEC1-41)
EXIST RECEP HAND WASH (SEC1-34)
EXIST LAB LTS (SEC1-36)
2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C 2#12+#12G-3/4"C
2#12+#12G-3/4"C
EXIST WIREMOLD FREEZER (SEC2-6) 2#12+#12G-3/4"C
EXIST WIREMOLD FREEZER (SEC2-8) 2#12+#12G-3/4"C
AIR COMPRESSOR 87548754 100%
RECEPTACLES LOAD 845016900 50%
PANEL 'CL1-D3A' 1477114770 100%
PIPE BASEMENT
ELECTRICAL RISER DIAGRAM
N.T.S.
LEGEND:
EXISTING CONDUIT & WIRING OR EQUIPMENT TO REMAIN
EXISTING CONDUIT & WIRING OR EQUIPMENT TO BE REMOVED
NEW CONDUIT & WIRING OR EQUIPMENT
EXISTING
PANEL
NLB-DD
120/208V
DISCONNECT AND REMOVE ALL EXISTING
PANELBOARDS, FEEDERS AND BRANCH CIRCUIT
WIRING AFTER NEW INSTALLATION COMPLETE AND
OPERATIONAL. (TYPICAL)
BASEMENT
1ST FLOOR
SWICHGEAR ROOM
EXISTING
CRITICAL
POWER
SWITCHBOARD
EXISTING
NORMAL
POWER
SWITCHBOARD
EXISTING
PANEL
CLB-DD
120/208V
EXISTING
PANEL
CHB-DD
277/480V
EXISTING
225KV
XFMR
EXISTING FEEDERS TO REMAIN
PROVIDE NEW FEEDER
4#2+#8G IN 1-1/2" CONDUIT
EXISTING
PANEL
CL1-D3A
TO
REMAIN
120/208V
EXISTING
PANEL
CL1-D3B
TO BE
REMOVED
120/208V
EXISTING
PANEL
CL1-D3
TO BE
REMOVED
120/208V
2ND FLOOR
EXISTING
225KV
XFMR
EXISTING
PANEL
NL1-D
120/208V
EXISTING
PANEL
NL1-D5
TO
REMAIN
120/208V
EXISTING
PANEL
CHB-D
277/480V
EXISTING
PANEL
CHB-DD1
277/480V
NEW
PANEL
CL1-D4
SEE
SCHED.
120/208V
PATHOLOGY LAB
EXISTING
PANEL
CH1-DA
TO
REMAIN
277/480V
PROVIDE NEW FEEDER
4#3/0+#4G IN 2" CONDUIT
DISCONNECT AND REMOVE EXISTING
FEEDER TO PANEL 'CL1-D3' AND PROVIDE
NEW FEEDER FROM EXISTING 175A
BRANCH CIRCUIT AS SHOWN
DRAWING TITLE
APPROVED PROJECT DIRECTOR
PROJECT TITLE
LOCATION
DATE CHECKED DRAWN
DRAWING NUMBER
BUILDING NUMBER
PROJECT NUMBER
REVISIONS DATE
NORTHPORT VA
MEDICAL CENTER
ENGINEERING
DEPARTMENT
ISSUED DATE
79 MIDDLEVILLE RD, NORTHPORT, NY 11768
DWG.
ELECTRICAL
ONE LINE DIAGRAM
AND PANEL SCHEDULE
ELECTRICAL POWER
UPGRADE FOR NEW
LABORATORY EQUIPMENT
01-07-22 KC KC
632-21-122
EP-102
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. FOR EXISTING EQUIPMENT, SUCH AS WIRING DEVICES, CONDUITS, ETC., SHOWN ON FOR EXISTING EQUIPMENT, SUCH AS WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRING COMPLETELY FROM THE ABANDONED CONDUITS. B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELY REMOVE ALL ABANDONED WIRING. C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTURBED AREAS. D. PROVIDE NEW SUPPORTS FOR ANY ELECTRICAL UTILITIES TO REMAIN THAT ARE PROVIDE NEW SUPPORTS FOR ANY ELECTRICAL UTILITIES TO REMAIN THAT ARE CURRENTLY SUPPORTED FROM THE EXISTING CEILING SUPPORT CHANNELS THAT WILL BE REMOVED. E. NO LIVE ELECTRICAL WORK SHALL BE PERMITTED. NO LIVE ELECTRICAL WORK SHALL BE PERMITTED.
AutoCAD SHX Text %%uGENERAL NOTES - DEMOLITION
AutoCAD SHX Text
2 REVISED PER FIELD CONDITION 3-12-21
AutoCAD SHX Text A. THE FEEDER FOR THIS PANELBOARD SHALL BE PROVIDED FROM BASEMENT THE FEEDER FOR THIS PANELBOARD SHALL BE PROVIDED FROM BASEMENT ELECTRICAL CLOSET AND FED FROM BOTTOM OF PANELBOARD. B. PROVIDE EMPTY CONDUITS AND JUNCTION BOXES ON THE CEILING FOR ALL SPARE PROVIDE EMPTY CONDUITS AND JUNCTION BOXES ON THE CEILING FOR ALL SPARE CIRCUIT BREAKERS FOR FUTURE USE.