Attachment 1a-Drawings.pdf
PDF 7 MB Posted
- Attached to
- Replace HVAC Systems, ALB SSC, Latham, NY Federal contract opportunity
- Solicitation number
- DTFAEN-16-R-00133
About this file
Attachment 1a-Drawings (pdf)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0001.pdf | ||
| Attachment 3-Asbestos Report.pdf | ||
| Attachment 5-Supplemental Offer Information.pdf | ||
| Attachment 2-Wage Rate.pdf | ||
| Attachment 1-Specifications.pdf | ||
| SIR DTFAEN-16-R-00133.pdf | ||
| Attachment 4-Business Declaration Form.pdf | ||
| SIR DTFAEN-16-R-00133.pdf | ||
| Attachment 1-Specifications.pdf | ||
| Attachment 4-Business Declaration Form.pdf | ||
| Attachment 5-Supplemental Offer Information.pdf | ||
| Attachment 1a-Drawings.pdf | ||
| Attachment 3-Asbestos Report.pdf | ||
| Attachment 2-Wage Rate.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTFAEN-16-R-00133 Attachment 1a
Linda Hennequant Stamp for Specs
Stamp for Specs
.0 co c' C)
H
G
F
E
D
C
B
A
ABBREVIATIONS
AIR HANDLING UNIT
ACCESS DOOR
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR CONDITIONING UNIT
BOTTOM OF DUCT /DIFFUSER
BTU PER HOUR
CONDENSATE DRAIN
CUBIC FEET PER MINUTE
CONNECTION
CONDENSING UNIT
DIRECT DIGIT AL CONTROL
ENTERING AIR TEMPERATURE
EXHAUST FAN
EXTERNAL STATIC PRESSURE
ELECTRIC UNIT HEATER
EXISTING
AHU
AD
AFF
AFG
ACU
BOD
BTUH
CD
CFM
CONN
cu
DOC
EAT
EF
ESP
EUH
EXIST
F
FOB
FWB
HP
KW
LF
MBH
MCA
MOCP
MD
NPT
NC
NIC
FILTER I CARBON FILTER
FAHRENHEIT DEGREES, DRY BULB
FAHRENHEIT DEGREES, WET BULB
HORSEPOWER
KILOWATT
LINEAR FEET
THOUSAND BTUH
MINIMUM CIRCUIT AMPACITY
MAXIMUM OVER CURRENT PROTECTION
MOTORIZED DAMPER
NATIONAL PIPE THREAD
NOISE CRITERIA I NORMALLY CLOSED
NOT IN CONTRACT
NO NORMALLY OPEN
OBD OPPOSED BLADE DAMPER
OA OUTSIDE AIR
OC ON CENTER
PSIG POUNDS PER SQUARE INCH GAUGE
RF RETURN FAN
RG RETURN REGISTER
SF SUPPLY FAN
SR SUPPLY GRILLE
TAB TESTING, ADJUSTING & BALANCING
UH UNIT HEATER
VD VOLUME DAMPER
WC WATER COLUMN
CONTROL SYMBOLS & ABBREVIATIONS
IM H/\/\I ELECTRIC MOTORIZED DAMPER OPERATOR
@ DIFFERENTIAL PRESSURE SENSOR
@ PRESSURE DIFFERENTIAL INDICATOR
� TEMPERATURE SENSOR
� SMOKE DETECTOR
fl u
FILTER
Al - ANALOG INPUT
AO - ANALOG OUTPUT
DI - DIGIT AL INPUT
DO - DIGIT AL OUTPUT
NC - NORMALLY CLOSED
I f f f f f f l ( l (
HV AC SYMBOLS
GRAPHIC
12X20 + t:=:=:=:1
-+- FS
� AP OR AD
vol --+--+-
M,H--+-
[Z] w 1111 +
I -- I +
IIXI IYJI +
II/I 1711 +
lt><I l?JI +
[2J th
(XXX)
HG .
L '
0<-0--r
CD .
T ' l:, .'
: I f--------(
:5 '\7' I I l!fHD -+Jr -l2:2:}-
I
DESCRIPTION
TEMPERATURE SENSOR
DUCT SIZE, FIRST FIGURE IS SIDE SHOWN
FIGURES INDICATE NET INSIDE DIMENSION
EXISTING DUCTWORK TO REMAIN
FIRE I SMOKE DAMPER (MOTORIZED)
FIRE DAMPER (MOTORIZED)
ACCESS PANEL OR ACCESS DOOR
MANUAL VOLUME DAMPER
MOTORIZED DAMPER
SMOKE DETECTOR
RETURN AIR GRILLE SIDEWALL
SUPPLY AIR REGISTER SIDEWALL
CEILING DIFFUSER W/ AIR FLOW
DIRECTIONAL ARROWS
RETURN AIR REGISTER, GRILLE OR
EXHAUST GRILLE
TURNING VANES IN ELBOW
FLEXIBLE CONNECTION
SLOPE IN DUCTWORK ELEVATION (UP OR DOWN)
RISE OR DROP IN DUCTWORK (SUPPL Yl
RISE OR DROP IN DUCTWORK (RETURN I EXHAUST)
RISE OR DROP IN DUCTWORK (OUTSIDE AIR)
SUPPLY DUCT, FIRST
FIGURE IS TOP SIDE
FIGURE IS TOP SIDE
POINT OF CONNECTION OF NEW TO EXISTING
DESIGN CFM AIR BALANCE
HOT GAS PIPING
LIQUID PIPING
RISE IN PIPING
DROP IN PIPING
CONDENSATE DRAIN
3-WAY MIXING VALVE, DOC
3-WAY CONTROL VALVE
PLUG VALVE
TEST PORT
AIR VENT
UNION
BALL VALVE
BALANCING VAL VE
HORIZONTAL UNIT HEATER
PIPE FLEXIBLE CONNECTION
5 • 4 I
GENERAL NOTES
1. BEFORE THE ST ART OF ANY WORK, CONTRACTOR SHALL VERIFY THE SCOPE OF WORK
LOCATIONS, ELEVATIONS, AND SIZES OF ALL DUCTWORK, EQUIPMENT AND ACCESSORIES
THAT ARE TO BE DEMOLISHED.
2. CONTRACTOR SHALL COORDINATE ALL WORK TO AVOID ANY AND ALL CONFLICTS WITH
SUBCONTRACTORS AND EMPLOYEES WORKING iN THE FACILITY. OFFSETS FOR NEW
DUCTWORK AND PIPING SHALL BE PROVIDED DURING INSTALLATION TO BEST SUIT THE
CONDITIONS. THE DRAWINGS ARE DIAGRAMMATIC AND ARE NOT TO BE SCALED TO
DETERMINE THE EXACT LOCATIONS OF MECHANICAL WORK.
3. ALL NEW EQUIPMENT SUPPORTS, FOUNDATIONS, AND CONCRETE PADS ARE DESIGNED
BASED ON THE EQUIPMENT SELECTED AS THE BASIS OF DESIGN FOR THIS PROJECT.
4. ALL AIR DEVICES AND DUCTWORK SIZES SHOWN REPRESENT NET INSIDE DIMENSIONS
UNLESS OTHERWISE INDICATED.
5. CONTRACTOR SHALL PROVIDE ALL NECESSARY VOLUME DAMPERS (VD) TO BALANCE THE
AIR DISTRIBUTION SYSTEMS TO WITH IN 51. OF THE LISTED AIR QUANTITIES SHOWN IN
THE CONSTRUCTION DOCUMENTS. VOLUME DAMPERS ARE TO BE INSTALLED AS FAR AS
POSSIBLE FROM THE AIR OUTLETS.
6. CONTRACTOR SHALL INST ALL NEW EQUIPMENT WITH MANUFACTURER'S REQUIRED
CLEARANCES FOR ACCESS AROUND ALL NEW EQUIPMENT.
7. CONTRACTOR SHALL MOUNT ALL WALL MOUNTED CONTROLLING DEVICES AT THE MINIMUM
HEIGHTS REQUIRED BY THE APPROVED APPLICABLE CODES AND REGULATIONS.
8. CONTRACTOR SHALL INST ALL APPROVED PIPE FITTINGS NECESSARY FOR ALL CONTROL
AND MEASURING DEVICES. ALSO, PROVIDE APPROVED DUCTWORK FITTINGS FOR ALL
CONTROL AND MEASURING DEVICES. ANY HOLES PUT IN THE DUCTWORK THAT ARE NOT
USED.SHALL BE PROPERLY PLUGGED.
9. ALL POWER WIRING, INTERLOCK WIRING, AND CONTROL WIRING SHALL BE INSTALLED
UNDER DIVISION 26.
10. CONTRACTOR SHALL REFERENCE STRUCTURAL DRAWINGS FOR INSTALLATION OF FLOOR
MOUNTED EQUIPMENT.
11. CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER'S REPRESENTATIVE ALL
OBSERVED CONDITIONS THAT MAY PREVENT THE CORRECT INSTALLATION OF THE NEW
MECHANICAL SYSTEM.
12. CONTRACTOR SHALL PROPERLY PATCH/SEAL ALL OPENING/PENETRATIONS IN EXISTING
WALLS RESULTING FROM DEMOLITION AND NEW WORK.
13 CONTRACTOR SHALL RECAPTURE ALL REFRIGERANT BEFORE THE ST ART OF DEMOLITION
WORK.
14. CONTRACTOR SHALL PROPERLY REMOVE ALL DEMOLITION DEBRIS AND MATERIAL FROM
WORK SITE.
15. INSTALLATION SHALL PROVIDE FOR READY ACCESS TO COILS AND OTHER CONTROL
DEVICES.
16. CONDENSATE DRAIN AND REFRIGERANT PIPING SHALL BE RIGID COPPER TUBING SUIT ABLE
FOR THE APPLICATION.
17. REFRIGERANT SUCTION AND LIQUID PIPING SIZE SHALL BE PER THE AC UNIT
MANUFACTURER'S RECOMMENDATION.
18. CONNECT UNIT SMOKE DETECTION TO EXISTING BUILDING FIRE ALARM SYSTEM AS
REQUIRED.
19. GALVANIZED STEEL DUCTWORK SHALL BE INSULATED/LINED PER DRAWINGS AND
SPECIFICATIONS.
20. REFRIGERANT AND CONDENSATE PIPING SHALL BE INSULATED AND JACKETED PER
SPECIFICATIONS.
21. NO MECHANICAL WORK IS TO BE DONE IN THE ENGINE GENERATOR ROOM.
22. CONTRACTOR REMOVE ALL AHU CONCRETE EQUIPMENT PADS AS REQUIRED.
23. CONTRACTOR SHALL USE FLEX COUPLINGS ON ALL REFRIGERANT PIPING CONNECTIONS
TO EACH AHU.
24. CONTRACTOR SHALL USE A PROFESSIONAL RIGGER FOR RIGGING OF ALL EQUIPMENT .
25. ALL EQUIPMENT SHALL BE STORED INSIDE AND NOT EXPOSED TO ANY WEATHER
CONDITIONS UNTIL INSTALLATION.
26. ALL DEMOLITION AND NEW WORK SHALL COMPLY WITH FEDERAL STATE AND LOCAL
REGULATIONS.
27. CONTRACTOR SHALL COORDINATE WITH EQUIPMENT MANUFACTURER AND THE VARIOUS
TRADES FOR PROVIDING EXACT LOCATION AND OPTIMAL ROUTING OF UNDERGROUND
AND ABOVE GROUND UTILITY CONNECTIONS.
28. CONTRACTOR SHALL SUBMIT SHEET MET AL SHOP DRAWINGS FOR COORDINATION WITH
ACTUAL FIELD CONDITIONS SO AS NOT TO CONFLICT WITH OR BLOCK ACCESS TO
EXISTING UTILITIES AND EQUIPMENT.
CLIMATIC ZONE SCHEDULE - DESIGN CONDITION
ROOM
DESIGNATION
WINTER INDOOR
DESIGN TEMPERATURE
& SET POINT ° F
SUMMER INDOOR
DESIGN
TEMPERATURE °F
COOLING
CONTROL
SET POINT
HUMIDIFICATION
SET POINT
DEHUMIDIFICATION
SET POINT
ASR-9
EQUIPMENT ROOM 68 72 74 NONE NONE
I 2 I 1
AIR CONDITIONING REPLACEMENT PHASING PLAN
THE TRANSFER OF AIR CONDITIONING OPERATION TO SUPPORT THE
ASR-9 FACILITY DURING CONSTRUCTION SHALL INCLUDE, BUT IS NOT
LIMITED TO, THE FOLLOWING,
1. NEW CONDENSING UNITS (AHU-CU-2 & AHU-CU-1) CAN BE
CONSTRUCTED OUTSIDE THE BUILDING'S NORTH WALL WITHOUT
AFFECTING THE EXISTING ASR-9 COOLING OPERATION. NEW
REFRIGERANT /CONDENSATE PIPING, POWER WIRING AND CONTROL
WIRING CAN ALSO BE ROUGHED IN WHERE PRACTICABLE WITHOUT
AFFECTING THE EXISTING COOLING OPERATION.
2. WITH THE EXISTING 15-TON SKYMARK ACU FULLY OPERATIONAL,
REMOVE EXISTING 5-TON A/C UNITS <AC-1, 2, 3, 4, 5 & 6) AND
PERMANENTLY CLOSE WALL PENETRATIONS FOR EACH <REFER TO
CIVIL DWGS FOR WALL CLOSURE REQUIREMENTS). REMOVE
ASSOCIATED SUPPORTBRACKETS, T'STATS AND POWER WIRING PER
ELECTRICAL DWGS/SPECS. PATCH REPAIR AND FINISH WALLS AS
NEEDED.
3. COMPLETE INSTALLATION OF AHU-2/ AHU-CU-2 SYSTEM AND
ASSOCIATED DUCTWORK. PROVIDE FACTORY START-UP. TESTING AND
ADJUSTMENT OF AHU-2/AHU-CU-2 SYSTEM.MAKE THE NECESSARY
TEMPERATURE CONTROL PROVISIONS FOR PROPER OPERATION UNTIL
ENTIRE SYSTEM CONTROLS ARE COMPLETED.
4. ONCE THE AHU-2/ AHU-CU-2 SYSTEM IS OPERATIONAL AND CAPABLE
OF MAINTAINING COOLING IN THE ASR EQUIPMENT ROOM, DISCONNECT
AND REMOVE THE EXISTING INDOOR 15-TON SKYMARK A/C UNIT AND
CLOSE UP RELATED EXTERIOR WALL PENETRATIONS.
5. COMPLETE INSTALLATION OF AHU-1/ AHU-CU-1 SYSTEM AND
ASSOCIATED DUCTWORK. PROVIDE FACTORY START-UP, TESTING AND
ADJUSTMENT OF AHU-1/ AHU-CU-1 SYSTEM. MAKE THE NECESSARY
TEMPERATURE CONTROL PROVISIONS FOR PROPER OPERATION UNTIL
ENTIRE SYSTEM CONTROLS ARE COMPLETED.
6. COMPLETE INSTALLATION OF DOC PANEL, ALL CONTROL COMPONENTS
AND WIRING.
7. PROVIDE COMPLETE SYSTEM PROGRAMMING, START-UP AN
COMMISSIONING PER SPECIFICATIONS.D
OPTION 1: TEMPORARY ACU-T
CONTRACTOR SHALL PROVIDE A 1001. RELIABLE SKID MOUNTED PORT ABLE 25 TON
PACKAGED AIR-COOLED AIR CONDITIONER INCLUDING TEMPORARY DUCTWORK, PROPERLY
SIZED ELECTRICAL FEEDER, CIRCUIT BREAKER, SAFETY SWITCH, AND TEMPERATURE
CONTROL TO OPERATE THE SYSTEM.
PROVIDE ALL MEANS NECESSARY TO OPERATE AND MAINTAIN THE TEMPORARY A/C
SYSTEM DURING CONSTRUCTION IN THE EVENT THAT THE EXISTING COOLING SYSTEM
BECOMES INSUFFICIENT TO MAINTAIN THE ASR EQUIPMENT ROOM AT 75 DEGREES F.
THE TEMPORARY EQUIPMENT SHALL BE SET IN PLACE AS CLOSE AS POSSIBLE OUTSIDE
THE BUILDING'S WEST WALL AND TEMPORARILY DUCTED THROUGH THE EXISTING SINGLE
DOORWAY WHILE MAINTAINING THE INTEGRITY OF THE BUILDING ENVELOPE (SEE DWG.
M007 BID ALTERNATE - TEMPORARY ACU & DUCTWORK LAYOUTl.
PROPERLY SIZED FLEXIBLE DUCTS SHALL BE SUPPORTED OVERHEAD TO TRAVERSE THE
EQUIPMENT ROOM AND DISTRIBUTE COOLING TO THE CRITICAL HOT SPOTS AS WELL AS
THE GENERAL AREA.
CONTRACTOR SHALL MAKE THE NECESSARY PROVISIONS TO ENSURE CONTINUOUS AND
ADEQUATE COOLING FOR THE ASR-9 EQUIPMENT IN THE EVENT THAT THE EXISTING A/C
SYSTEM BECOMES INEFFECTIVE OR UNRELIABLE.
TEMPORARY SITE PROVIDED POWER SOURCE SHALL BE COORDINATED WITH THE FACILITY
AND MAINTAINED BY THE CONTRACTOR.
CONTRACTOR SHALL PROVIDE DUCTWORK, INSULATION, HANGERS, SUPPORTS, PLYWOOD AND
LABOR TO INST ALL AND RESTORE CONDITIONS ASSOCIATED WITH THE TEMPORARY A/C
INSTALLATION. THE STANDBY SYSTEM SHALL BE TESTED IN ACCORDANCE WITH
SPECIFICATIONS.
UPON ACCEPTANCE OF THE NEW COOLING SYSTEM OPERATION, REMOVE TEMPORARY A/C
UNIT, ASSOCiATED DUCTWORK AND ELECTRICAL CONNECTIONS. THE BUILDING'S DOOR SHALL
BE REINSTALLED AND RESTORED TO ITS PRE -EXISTING CONDITION.
1---1-----+- - - - - -- -- -·--··-
H
G
F
E
D
C
REV
AF PROVED
DATE
- --·-·--- - - - - - --------+-- ---l-------1----1
A?VD BDESCRIPTION JCS
REDLINE
DATE
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
AREA ATO - TECHNICAL OPERATIONS EASTERN SERVICE
__ c___....c___;_::.i
ALBANY
ASR
HVAC SYSTEM REPLACEMENT
HVAC SYMBOLS. ABBREVIATIONS
& GENERAL NOTES
NY
!!,1 0 0 0 "
DTFAEN-16-R-00133 Attachment 1a 6 I 5 + 4 I 3
PROJECT
DE:S!GNEO
DRAW-\!
ENGINEER
RC
ON
MGR, ENGINEERING - CENTER B
ISSLEO BY JATE
0510512016 iJCN 1004182
RE\/
A� E
�0
DT•14 773 CHi:.CKED
ENGINEERING SERVICES )RAWING NO
INFRASTRUCTURE ]ALB-1004182-M001 •
w
I 2 1 I
ORAl'/ING PRODUCED ON AEA RO MICROST ATION SYSTEM
Text Box
OPTION 1:
| PrintRoom 0281 |
| PrintRoom 0282 |
| PrintRoom 0283 |
| PrintRoom 0284 |
| PrintRoom 0285 |
| PrintRoom 0286 |
| PrintRoom 0287 |
| PrintRoom 0288 |
| PrintRoom 0289 |
| PrintRoom 0290 |
| PrintRoom 0291 |
| PrintRoom 0292 |
| PrintRoom 0293 |
| PrintRoom 0294 |
| PrintRoom 0295 |
| PrintRoom 0296 |
| PrintRoom 0297 |
| PrintRoom 0298 |
| PrintRoom 0299 |
File details come from the government source that posted it. Updated .