DRAWING.pdf

PDF 11 MB Posted

Attached to
HOSE TEST BENCH Federal contract opportunity
Solicitation number
SPMYM221Q1117
Issued by
Defense Logistics Agency Land and Maritime

About this file

This document summarizes a federal solicitation for the procurement of a hose test bench. The Defense Logistics Agency Land and Maritime is seeking offers for a hose test bench to support maintenance operations at the Puget Sound Naval Shipyard & IMF in Bremerton, Washington. The requirement is set aside only for small businesses and will use low price technically acceptable evaluation factors. Offerors must register in the System for Award Management and review the solicitation, which will be posted at SAM.gov. Questions regarding the solicitation must be sent by email to the named contracting specialist by the response deadline. The contract to be awarded will be a firm fixed price commercial purchase order for product delivery to the stated location.

View the file

Other files for this federal contract opportunity

Other files attached to HOSE TEST BENCH, newest first.
File Type Posted
21-Q-1117U0003.pdf PDF
21-Q-1117U0002.pdf PDF
21-Q-1117U0001.pdf PDF
CDRLS.pdf PDF
STATEMENT OF WORK.pdf PDF
21-Q-1117.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT B

Technical Drawing

ATTACHMENT B:

PSNS and IMF Drawing X-99482 “HYDROSTATIC TEST BENCH FOR OIL AND SEAWATER HOSES”

Drawing is contained on following pages.

CONCEPTUAL DRAWING

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

B

CODE

A

B

C

D D

C

B

A

PRODUCTION ENGINEERING AND FACILITIES DIVISION, CODE 980

DATE

DEPARTMENT OF THE NAVY PUG ET SOUND NAVAL SHIPYARD

APPROVAL

GENERAL TOLERANCES

REVISION

BREMERTON, WASHINGTON

12 TO 72

OVER 72

DIM

UNDER 12

1 PL 3 PL 2 PL

FRACTIONS

DECIMALS

ANGULAR +

TITLE

SIGNATURE

BY APPROVEDDESCRIPTIONZONEREV DATE

CONCURRENCE

82522

1v

1/32 1/2

THIS DRAWING DOES NOT REQUIRE A DISTRIBUTION STATEMENT. IN ACCORDANCE WITH DOD 5200.1-R THIS DOCUMENT IS UNCLASSIFIED AND DOES NOT WARRANT A FOUO STATEMENT (5200.1-R AP3.2.1).

THIS DRAWING DOES NOT CONTAIN CRITICAL TECHNOLOGY AS DEFINED BY NAVSEAINST 5230.12.

NO DEVIATIONS SHALL BE MADE WITHOUT AUTHORIZATION UNLESS NOTED OTHERWISE.

SOLIDEDGE FILE:

X-99482 HYDRO TEST BENCH OIL SEAWATER HOSES.DFT

N.A. N.A. N.A.

N.A.

FSR 0099-9122

N.A.N.A.

N.A.N.A.

N.A.

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

B

CODE

A

B

C

D D

C

B

A

DATE

APPROVAL

DIM

1 PL 3 PL 2 PL

FRACTIONS

DECIMALS

TITLE

SIGNATURE

82522 X-99482

1v

1/32 1/2

1 OF 41SOLIDEDGE FILE:

X-99482 HYDRO TEST BENCH OIL SEAWATER HOSES.DFT

N.A. N.A. N.A.

N.A.

N.A.N.A.

N.A.N.A.

N.A.

ORIG

HYDROSTATIC TEST BENCH FOR OIL AND

SEAWATER HOSES, S99GM, B-1195

SHEET TITLE SHEET TITLE

1 COVER SHEET, TOLERANCES, AND INDEX 22 STRUCTURAL PART DETAILS

2 GENERAL NOTES AND REFERENCES 23 ISOMETRIC VIEWS, ROLLING MANIFOLD

3 GENERAL NOTES, CONTINUED 24 ORTHOGRAPHIC VIEWS, ROLLING MANIFOLD STRUCTURE

4 GENERAL NOTES, CONTINUED 25 DETAIL, DRAIN SUMP AND INLET MANIFOLD

5 GENERAL NOTES, CONTINUED 26 STRUCTURAL PART DETAILS

6 PARTS LIST PAGE 1 27 STRUCTURAL PART DETAILS

7 PARTS LIST PAGE 2 28 NOTIONAL SHEET METAL PATTERNS

8 PARTS LIST PAGE 3 29 CONTROL STAND STRUCTURAL DETAILS

9 PARTS LIST PAGE 4 30 CONTROL STAND STRUCTURAL DETAILS

10 PARTS LIST PAGE 5 31 PIPING & INSTRUMENTATION DIAGRAM

11 PARTS LIST PAGE 6 32 PIPING & INSTRUMENTATION DIAGRAM - AIR CONTROLS

12 PARTS LIST PAGE 7 33 ISOMETRIC VIEW PIPING ASSY

13 GENERAL ARRANGEMENT ISOMETRIC VIEW 1 34 PIPING DETAILS

14 GENERAL ARRANGEMENT ISOMETRIC VIEW 2 35 PIPING DETAILS

15 GENERAL ARRANGEMENT ORTHOGRAPHIC VIEWS 36 PIPING: FIXED MANIFOLD

16 ASSEMBLY DETAIL VIEWS 37 PIPING: ROLLING MANIFOLD

17 CORNER PAN ASSY DETAIL VIEWS 38 BENCH PIPING DETAILS

18 CORNER PAN STRUCTURAL DETAILS 39 CONTROL PANEL DETAILS

19 STRUCTURAL PART DETAILS 40 CONTROL PANEL DETAILS

20 STRUCTURAL PART DETAILS 41 SAFETY SHIELDS

21 STRUCTURAL PART DETAILS --- ---

INDEX

NONE

HYDROSTATIC TEST BENCH

FOR OIL AND SEAWATER HOSES

( S/99 GEN MAINT AREA, BLDG 1195 )

/s/ D. BROWN

7/17/19DESIGN/DRAWN: G. HENZEL

C/106

S/99

REVIEWED:

980M.1 SUPV

7/26/19

/s/ T. HEINO 10/10/19

/email/ W. MEIGS 10/30/19

/email/ R. ACEVEDO 12-18-19

D

C

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

2 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

REFERENCES

A. PSNS INDUSTRIAL PROCESS INSTRUCTION 0505-904 – “HOSES, TEMPORARY SERVICES, NON-NUCLEAR” B. PSNS INDUSTRIAL PROCESS INSTRUCTION 5300-901 – “WATER SUPPLY, SHORE TO SHIP OR SUPPORT EQUIPMENT, INSTALLATION OF” C. PSNS DRAWING X-90001 "RACK; HYDROSTATIC HOSE TESTING AT NASNI (P-702) (REFERENCE ITEM #2281)” D. PSNS DRAWING x99185 "HOSE TEST STAND (Shop - 99) “

E. PSNS DRAWING X-99417 “HYDROSTATIC TEST BENCH FOR POTABLE WATER HOSES”

F. AMERICAN WELDING SOCIETY (AWS) D 1.1 (“STRUCTURAL WELDING CODE – STEEL”) AND D 9.1 (“SHEET METAL WELDING CODE”), G. AWS D 10, “RECOMMENDED PRACTICES FOR WELDING AUSTENITIC CHROMIUM NICKEL STAINLESS STEEL PIPE AND TUBING”

H. AM. SOC. OF MECHANICAL ENGINEERS (ASME) B31.1 POWER PIPING

I. ASME B31.,3 PROCESS PIPING

GENERAL NOTES

1. This drawing was developed to support Facility/Service Request (FSR) number 0099-9122, to design a replacement hydrostatic hose test bench (referred to as “test bench” hereafter) for Shop 99 (General Maintenance), to be located in

Bldg 1195 of Puget Sound Naval Shipyard (PSNS) in Bremerton WA.

2. The test bench shall hydrostatically test oily-water and saltwater hoses. It will replace a similar, existing test bench. Hose test requirements are established by REF A and REF B.

3. The test bench has been designed conceptually, however the contractor shall be responsible for the complete design, supply and delivery of the test bench, per the requirements herein.

4. Description:

A. This test bench is similar in design and function to previous designs (REF C, D, E). The bench consists of a trough, piping and controls. It shall be suitable to accommodate, with use of Shipyard (SY)-provided adapters, up to four, 50-foot long, 4-inch hoses simultaneously on the bench.

B. After filling hoses with water from shop water supply, hydrostatic pressure shall be applied with a SY-provided air operated diaphragm type pump set to stop pumping at specified test pressure.

C. The return manifold shall be mounted on a rolling base, to allow for variation in hose length and expansion of pressurized hoses. Connections to rolling manifold shall be flexible and of suitable length or retractable to allow movement of rolling manifold. The trough shall be sloped to ensure drainage to a sump connected to existing collection tank. During draining of the hoses, the operator shall have the option of applying pressurized air at fixed manifold to assist in draining the hoses. Bench piping shall drain into existing hoses that route test water to existing collection tank outside Bldg 1195.

D. The test bench shall be controlled by a pneumatic control panel similar to that shown on SHEET 39-40.

E. Valves shall be pneumatically actuated.

F. System allowable working pressure shall be no less than 300 psig.

G. Pressure settings (set prior to first use):

i. ITEM # 61 - Pneumatic control system air pressure regulator 90 psig

ii. ITEM #142 - Pneumatic hydrostatic pump air supply pressure regulator PER MFR SPECS TO ACHIEVE REQD TEST PRESSURE

iii. ITEM #143 - Air blowdown pressure regulator 40 psig

iv. ITEM #159 - Pressure relief valve setting 330 psig

5. Drawing Notes:

A. Reference dimensions are denoted by parenthesis, e.g. “ ( 60’-0”) ”. These dimensions are approximate and are included for informational purposes.

B. For clarity, in some cases multiple occurrences of the same part have been designated by use of split part bubbles where the upper numeral indicates the part number, and the lower numeral indicates the number of occurrences of the part in the assembly.

6. The types of components must be as shown and may not be substituted without permission. However, where a particular make or manufacturer of equipment is specified it is not the intent of this document to exclude other products if they are of equal merit (e.g. pressure, temperature, flow rating, strength, physical size, function).

7. Supplied equipment shall be provided with energy isolating devices (e.g., valves, etc.) which protect personnel from the release of hazardous energy. The devices shall be designed and manufactured such that they can be padlocked in the user-selected position (on or off, open or closed) to prevent inadvertent or unauthorized change.

8. Supplied equipment shall be designed to operate safely and continuously indoors in a damp industrial environment. All components shall be “wash-down” rated and compatible with petroleum product residue and salt water.

Notes are continued on next page

NONE

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

3 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

General Notes continued:

9. Welding and Structural:

A. Welding of structural and sheet steel shall be in accordance with (IAW) REF F and other AWS codes as appropriate. Do not overweld structure such that distortion of base material beyond tolerances occurs. Quality assurance of welds shall require visual inspection for completeness, size and cracking at minimum.

B. Welding of piping shall be IAW applicable section of REF G and other AWS codes as appropriate. Quality assurance of welds shall require visual inspection for completeness, size and cracking at minimum.

C. Remove all burrs and weld splatters and break or grind all sharp edges and corners smooth. Exclude sharp screw points or other items that might snag or cut hoses or injure or impair operators.

D. Pipe hangers, structural framing (e.g. “Unistrut” or t-slot style metal structural systems.) and associated hardware shall be used as required to support piping runs and components. Install IAW MSS SP-58 and SP-69. Note that most required structural framing material is not shown in drawings for clarity but is required.

E. Stainless Steel angle brackets shall be installed on each leg to attach the bench to the floor. Brackets shall be vertically adjustable by up to 6 inches to compensate for rough floor surface at installation site.

F. Surface Preparation (Do not prep or paint galvanized or stainless steel parts):

i. Clean other ferrous metals by solvent cleaning per SSPC-SP1, followed by near white metal blast cleaning to bare metal per SSPC-SP10. Localized surface preps can be accomplished utilizing power tools per SSPC- SP11, or hand tools per SSPC-SP2.

G. Painting or Powder Coating options (Do not prep or paint galvanized or stainless steel parts):

i. MIL-PRF-23236 (2-part epoxy): Apply two coats. Each coat 4-8 mils Dry Film Thickness (DFT). Total 8-16 mils DFT. Topcoat shall be different color than the prime coat. Final coat color shall be gray.

ii. MIL-DTL-24441 Type IV (2-part epoxy): Apply two coats. Each coat 4-6 mils Dry Film Thickness (DFT). Total 8-12 mils DFT. Topcoat shall be different color than the prime coat. Final coat color shall be gray.

iii. Epoxy or Polyester powder coatings are acceptable alternatives. Use polyester powder coating for items/components exposed to ultraviolet light for extended periods. Use epoxy powder coating for items/components not exposed to ultraviolet light for extended periods, such as those normally located inside buildings or structures. Final color shall be gray.

10. Piping and Valves:

A. SHEET 31 and 32 show piping, instrumentation and pneumatic control system diagrams.

B. Minor component relocation and piping system rerouting is acceptable if the modifications do not affect intended function of system. For example, the use of alternative, equivalent fittings such as pipe to tube connectors, tees, elbows, etc. is allowable. The use of more or less fittings is allowable. The number and location of fittings shown in this package is for general guidance. Refer to schematics and notes in this package to ensure that pressure, chemical compatibility, functional and other requirements are met when making allowable modifications.

C. Piping shall be seamless and sized and specified/sourced for use at pressures in excess of 150% of maximum pressures listed herein. Valves shall be leak-tight to pressure in excess of maximum system pressure of their section, including during leak testing. Air supply piping and pneumatic control components shall be capable of operating at minimum 90 psi shop air supply pressure.

D. Threaded connections are used in this drawing; however, welded connections are also acceptable and may be beneficial for some piping sections. Contractor may substitute welded, seal-welded, or brazed connections as appropriate, but ensure threaded, union or flanged connections are used where required for disassembly, maintenance or replacement of all valves, sensors and similar components.

E. Teflon tape or pipe thread sealant shall be used to seal all pipe thread joints. Materials shall be compatible with oil and seawater.

F. Pipe unions and/or flange connections shall be added as required to allow for ease of manufacture and partial disassembly of piping for maintenance and repair. These items are not included in the part list. Some possible locations are shown in this drawing. The valves specified herein are three-piece design to allow maintenance of valve body without disassembly of piping.

G. Pneumatically operated valves shall actuate in such a manner as to prevent water hammer or explosive release of hydrostatic or pneumatic pressure ( slow actuating speeds, for example ). Adjustable flow mufflers are included in the parts list as one possible method to control actuating speeds.

H. Isolation valves shall be included to allow complete or partial isolation of the piping system.

I. Piping shall be located under test bench control stand such that trip, injury and damage hazards shall not be present. Piping shall be protected by easily removable panels. Utilize thumbscrews or similar method for removal.

J. A sight glass or other method shall be installed to allow operators to ensure water has filled the hoses prior to hydrostatic testing.

K. Piping shall be IAW REF H and I.

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

4 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

General Notes continued:

11. Pneumatic and Compressed Air Systems:

A. Components shall be heavy duty or industrial type, and designed to operate safely in a wet industrial environment.

B. The equipment delivered and all accessory parts shall operate from a single source of dry compressed air that is 80 to 120 psig.

C. Include Lock-Out provisions on all air isolation valves. System as designed includes valve and exhaust muffler to allow mechanics to depressurize system pneumatic energy after isolation.

D. Ensure control system components are properly rated for air pressure and flow requirements herein.

E. Air tubing, pipe and components shall be rigidly mounted with “Unistrut™” style hardware, or similar structure as necessary. Use metallic tubing for any exposed runs, and for the connection from the control panel to the vicinity of the rolling manifold and from air supply to the control panel.

F. Design and installation of pneumatic system shall be performed by or under direct supervision of persons having experience in pneumatic systems.

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

5 OF 41CONCEPTUAL DRAWING

General notes continued

12 Control System Requirements:

A. Review piping schematic and notional control panel design.

B. Control system shall be pneumatic.

C. Operating controls shall be safely accessible outside of enclosure without opening enclosure (e.g. mounted on exterior of enclosure or through front door of panel).

D. Control system shall be capable of being maintained by Puget Sound Naval Shipyard (PSNS) without contractor assistance.

E. Design of control system shall be performed by, or under direct supervision of, a qualified engineer or technician with pneumatic controls experience.

F. Piping and control system shall be designed to prevent air entrapment in hoses during operation of the test bench. Air entrapment would create a hazardous condition by allowing a volume of air to be pressurized to the system test pressure during hydrostatic testing.

G. Operational parameters. Final design of control system shall be determined by contract awardee. The following items shall be included::

i. Valve and pressure status shall be provided using air operated indicators at control panel.

ii. Control system allows operator to open/close valves and run pump using control panel, however safety interlocks are required to prevent user from creating unsafe condition, such as pressurizing the hoses with compressed air.

iii. “Safe” lineup: when air pressure is secured or lost, the system shall return to a “safe” valve lineup, provided by “Fail-Open”/”Normally-Open” or “Fail-Closed”/”Normally-Closed” spring-actuated valves.

iv. Example Safe Lineup:

1. Pump Air Valve: Closed

2. Vent valve:: Open

3. Blowdown Valve:: Closed

4. Air Interlock Valve Closed.

v. Isolation valves shall be lockable.

vi. Hydrostatic pump will be set by shop to ensure correct outlet pressure is set.

H. Include basic schematic of piping system on or adjacent to the control panel showing location of corresponding valves for operator reference.

13 Pressurized Leak Tests (refer to piping schematic for valve locations. These tests shall occur at both point of origin and after delivery and installation at point of destination):

A. Remove or adjust pressure relief valve to allow testing to 450 psig. (150% of maximum working pressure) B. Connect four separate 2-inch ID hoses between the supply and drain manifolds, with pressure rating in excess of 450 psig.

i. As an alternative to connecting and testing four hoses simultaneously, one or more 1-1/2” hoses may be tested at a time provided all connections are tested.

C. Open ball valves for each end of hose, and open vent valve.

D. Align Pump Inlet Select Valve to draw water from water supply.

E. Align Pump Outlet Select Valve to supply water to the test bench supply manifold.

F. Open Pump Air Supply Valve and fill hoses with clean water until water exits from vent pipe. Allow water to exit for a minimum of one minute or as necessary to completely flush all components and purge air. Observe liquid level sight window to verify air has been purged and the hoses are completely filled with water.

G. Close Vent Valve.

H. Close Pump Air Supply Valve or water supply valve to secure water supply.

I. When ready, pressurize the system to 450 +5/-0 psig. Maintain this pressure for minimum of 10 minutes. No leaks or physical deformation of test bench piping or components is allowed during test. Minor pressure drop is possible from stretching of hose, for example, therefore the pressure pump may run less than 5 seconds per minute during hydrostatic test to maintain pressure, once the pressure has stabilized.

J. After successful test, re-install any removed components and return settings to values for normal operation, and as listed in Note 4.

K. Repeat testing procedure at maximum allowable operating pressure of 300 psi. Hold pressure for 30 minutes. No leaks or physical deformation of test bench piping or components is allowed during test. Minor pressure drop is possible from stretching of hose, for example, therefore the pressure pump may run less than 5 seconds per minute during hydrostatic test to maintain pressure, once the pressure has stabilized L. Prepare and provide signed test summary documents for all tests on corporate letterhead, including descriptions, dates and photos of tests and names of test personnel.

14 Preparation prior to first use after assembly or re-assembly of the piping during construction or installation: all hoses and pipes shall be flushed with clean shop water. All strainers and filters shall be cleaned after flushing. Internal pressure relief bypass in the pressure pump, if so equipped, shall be adjusted per Note 4, per manufacturer procedures. The overpressure relief valve shall open at setting listed in Note 4, and adjustment levers or screws (if any) shall be wire-tied to prevent alteration of bypass pressures.

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

6 OF 41CONCEPTUAL DRAWING

X-99482 ORIGPARTS LISTASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

SOME PARTS APPEAR ON MORE THAN ONE ITEM# DUE TO DRAWING REVISIONS. ADD ALL FOR

TOTAL REQD QTY.

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

1 2 ANGLE, 1-1/2", 0.125 THK, APPROX 2 FT LENGTH STRUCTURAL STAINLESS STEEL 304 ASTM A276

2 2 ANGLE, 1-1/2", 0.125 THK, APPROX 3 FT LENGTH STRUCTURAL STAINLESS STEEL 304 ASTM A276

3 6 ANGLE, 2" X 2" X 1/4" THICK, 42" LENGTH APPROX STRUCTURAL STEEL, GALVANIZED ASTM A36 CUT TO SUIT

4 3 ANGLE, 2" X 2" X 1/4" THICK, 42" LENGTH APPROX STRUCTURAL STEEL, GALVANIZED ASTM A36 CUT TO SUIT

5 2 ANGLE, 2" X 2" X 1/4" THICK, 56" LENGTH APPROX STRUCTURAL STEEL, GALVANIZED ASTM A36 CUT TO SUIT

6 1 ANGLE, 2" X 2" X 1/4" THICK, 80" LENGTH APPROX STRUCTURAL STEEL, GALVANIZED ASTM A36 CUT TO SUIT

7 2 ANGLE, 3" X 3" X 1/4", 42" LENGTH APPROX STRUCTURAL STEEL, GALVANIZED ASTM A36 CUT TO SUIT

8 1 BUMPER WITH 5/16"-18 UNC X 7/8 IN LONG MOUNTING STUD STRUCTURAL RUBBER, OIL RESISTANT - MCMASTER CARR PN 9541K15 OR EQV

9 2 CHANNEL, 12 GA, 1" X 2" X APPROX 40", CUT-OUT COAMING STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 FABRICATED FRM 1 X 2 CHANNEL OR SHEET METAL, 10 18 CHANNEL, C3x4.1, 3" X 1-3/8" X 3/16", 39-1/2 LENGTH STRUCTURAL STEEL ASTM A36

11 10 CHANNEL, C3x4.1, 3" X 1-3/8" X 3/16", 39-1/2" LENGTH, MODIFY TOP STRUCTURAL STEEL ASTM A36 CUT BACK TOP TO CLEAR ROLLNG MNFLD

12 1 CHANNEL, C3x4.1, 3" X 1-3/8" X 3/16", 76" LENGTH STRUCTURAL STEEL ASTM A36

13 2 CHANNEL, C3x4.1, 3" X 1-3/8" X 3/16", 84" LENGTH STRUCTURAL STEEL ASTM A36

14 56 DISC, PLASTIC 3 IN DIA X 3/4 IN THK STRUCTURAL UHMW DRILL AND COUNTERBORE HOLE IN CENTER TO FIT GRATE CLIP

15 28 FLOOR CLIPS, 2 IN X 2 IN X 1/8 IN THICK ANGLE, 1/2 IN HOLES STRUCTURAL STAINLESS STEEL 304 ASTM A240 FABRICATE

16 1 GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 2 FT X 3 FT STRUCTURAL FRP CHEM RESISTNT, SIZE TO FIT, INSTALL WITH MENISCUS OR SMOOTH SURFACE UP, SEAL CUT

EDGES PER MFR INST

17 5 GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 3 FT X 10 FT STRUCTURAL FRP - CUT IN HALF PER DWG. CHEM RESISTNT, SIZE TO FIT, INSTALL WITH MENISCUS OR SMOOTH

SURFACE UP, SEAL CUT EDGES PER MFR INST

18 1 GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 3 FT X 3 FT STRUCTURAL FRP CHEM RESISTNT, SIZE TO FIT, INSTALL WITH MENISCUS OR SMOOTH SURFACE UP, SEAL CUT

EDGES PER MFR INST

19 1 GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 3 FT X 5 FT STRUCTURAL FRP CHEM RESISTNT, SIZE TO FIT, INSTALL WITH MENISCUS OR SMOOTH SURFACE UP, SEAL CUT

EDGES PER MFR INST

20 1 GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 6 FT X 3 FT, TRIANGULAR AREA STRUCTURAL FRP CHEM RESISTNT, SIZE TO FIT, INSTALL WITH MENISCUS OR SMOOTH SURFACE UP, SEAL CUT

EDGES PER MFR INST

21* 1 HANGER, PIPE, RIGID, 1-1/4" DIA, W/ NUTS AND BOLTS STRUCTURAL STEEL ASTM F708 CUT TO SUIT, WELD IN PLACE

22 3 HANGER, PIPE, RIGID, 2" DIA, W/ NUTS AND BOLTS STRUCTURAL STEEL ASTM F708 CUT TO SUIT, WELD IN PLACE

23 5 HANGER, PIPE, RIGID, 2" DIA, W/NUTS AND BOLTS STRUCTURAL STEEL ASTM F708 CUT TO SUIT, WELD IN PLACE

24 5 HANGER, PIPE, RIGID, 3" DIA, W/ NUTS AND BOLTS STRUCTURAL STEEL ASTM F708 CUT TO SUIT, WELD IN PLACE

25 2 HANGER, PIPE, RIGID, 3" DIA, W/NUTS AND BOLTS STRUCTURAL STEEL ASTM F708 CUT TO SUIT, WELD IN PLACE

26 1 HINGED DOOR ASSY, EXTRUSION FRAME, AS REQD APPROX 29" X 29" CUSTOM SIZE STRUCTURAL POLYCARBONATE, ALUMINUM - ADD HINGES AND MAGNETIC CATCH AND OTHER HARDWARE AS NEEDED

27 1 HINGED SHIELD ASSY, EXTRUSION FRAME, AS REQD APPROX 39" X 39" CUSTOM SIZE STRUCTURAL POLYCARBONATE, ALUMINUM - ADD HINGES AND MAGNETIC CATCH AND OTHER HARDWARE AS NEEDED

28 1 PLATE, 1/4 IN THK, ROLLING MANIFOLD BASE, APPROX ROUGH SIZE 51" X 53" STRUCTURAL STEEL ASTM A36 FABRICATED PART, REF PATTERN SHT 28

29 1 PLATE, 1/4 IN THK, STATIONARY MANIFOLD PLATE, APPROX 24" X 30" STRUCTURAL STEEL ASTM A36 FABRICATED PART, REF PATTERN SHT 25

30 4 PLATE, 1/4", RETAINING CLIP STRUCTURAL STEEL ASTM A36 FABRICATED PART, REF SHT 26

31 56 SADDLE CLIP ASSY, FOR 1-1/2 INCH SPACED GRATING, INCLUDING BOLT, NUT, WASHER TO FIT. STRUCTURAL STAINLESS STEEL 304 MC MASTER CARR 7010T23 OR EQUIV, B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

7 OF 41CONCEPTUAL DRAWING

X-99482 ORIGPARTS LIST (CONT)

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

32 1 SAFETY SHIELD ASSY, 19 IN X 36 IN STRUCTURAL COML - MC MASTER CARR PN 5748T56 OR EQV

33 7 SHEET, 12 GA, 20"X40", LEG SUPPORT STRUCTURAL STEEL, GALVANIZED ASTM A36

34 2 SHEET, 12 GA, 20"X40", LEG SUPPORT STRUCTURAL STEEL, GALVANIZED ASTM A36

35 1 SHEET, 12 GA, 9" X APPROX 10 FT LENGTH STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 CORNER ASSY INNER SIDE PLATE

36 1 SHEET, 12 GA, 9" X APPROX 20 FT LENGTH STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 CORNER ASSY OUTER SIDE PLATE

37 8 SHEET, 12 GA., 9 IN X 12 FT LENGTH, SIDE PLATE STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

38 1 SHEET, 12 GA., 9 IN X 12 FT LENGTH, SIDE PLATE WITH CUTOUT, "LEFT" SIDE OF BENCH STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

39 1 SHEET, 12 GA., 9 IN X 12 FT LENGTH, SIDE PLATE WITH CUTOUT, "RIGHT" SIDE OF BENCH STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

40 1 SHEET, 12 GA., BUMPER POST, APPROX 8"X10" STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 FABRICATED PART

41 1 SHEET, 12 GA., INLET END PLATE, BRUSHED FINISH (#4), APPROX 3 SQ FT STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 FABRICATED PART, SEE PATTERN

42 1 SHEET, 12 GA., SMALL END PLATE, BRUSHED FINISH (#4), APPROX 3 SQ FT STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 FABRICATED PART, SEE PATTERN

43 1 SHEET, 16 GA, BOTTOM PAN, CORNER, BRUSHED FINISH (#4), APPRX 60 SQ FT STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 MFR FROM MULTIPLE SHEETS AS NEEDED

44* 1 SHEET, 16 GA., 4FT X 12 FT, BOTTOM PAN, BRUSHED FINISH (#4) STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

45 3 SHEET, 16 GA., 4FT X 12 FT, BOTTOM PAN, BRUSHED FINISH (#4) STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

46 1 SHEET, 16 GA., 4FT X 12 FT, BOTTOM PAN, DRAIN SUMP END, BRUSHED FINISH (#4) STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10

47 1 SHEET, MIN 16 GA, APPROX 24"X 33", 6 SQ FT, BRUSHED FINISH (#4) STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 OPERATOR STAND TOP, MFR TO SUIT

48 2 SHEET, MIN 16 GA, CONTROL STAND SIDE PANELS, APPROX 22" X 27", 4 SQ FT, BRUSHED FINISH (#4)

STRUCTURAL STAINLESS STEEL 304 ASTM A240/A666-10 OPERATOR STAND SIDES, MFR TO SUIT

49 1 SKIRT, NEOPRENE 6" WIDE, APPROX 6 FT LENGTH STRUCTURAL NEOPRENE - OIL RESISTANT

50 2 STRUT, 1-5/8", SLOTTED HOLES APPROX 24" LENGTH STRUCTURAL STEEL, GALVANIZED "UNISTRUT" OR EQV, (CUT TO SUIT)

51 7 STRUT, 1-5/8", SLOTTED HOLES APPROX 32" LENGTH STRUCTURAL STEEL, GALVANIZED "UNISTRUT" OR EQV, (CUT TO SUIT)

52 4 STRUT, 1-5/8", SLOTTED HOLES APPROX 40" LENGTH STRUCTURAL STEEL, GALVANIZED "UNISTRUT" OR EQV, (CUT TO SUIT)

53 4 WHEEL, 3" DIA, 1/2" SPINDLE, SOLID STRUCTURAL POLYURETHANE - 1/2" BORE

54 1 MANIFOLD, CONTROL AIR LINE, 8-PORT 1/4" NPTF OUTLETS. 3/8" NPTF INLETS PNUEMATIC CNTRL STAINLESS STEEL - PNEUMADYNE M20-250-8 OR EQV

55 1 ADAPTER, 1/4" TUBE COMPRESSION TO NPTM PNEUMATIC CNTRL STAINLESS STEEL 316 - PARKER 4-4 FBZ-SS OR EQV

56 1 CONTRL PNL ENCLOSURE, HINGED, SLANTED-TOP, NOM 11 IN HIGH X 20 IN WIDE X 14 IN DEPTH PNEUMATIC CNTRL STEEL, PAINTED COML - MCMASTER CARR PN 70015K21 OR EQUIV

57 1 CONTRL PNL LID (PART OF CONTRL PNL ENCLOSURE), NOM 20" X 16" FACE PNEUMATIC CNTRL STEEL, PAINTED COML - PART OF MCMASTER CARR PN 70015K21 OR EQUIV

58 1 ELBOW, 1/4" NPTF TO COMPRESSION, SWIVEL PNEUMATIC CNTRL STAINLESS STEEL 316 - FOR STAINLESS TUBE

59 13 ELBOW, PUSH-QUICK, 1/4" TUBE TO 3/8" NPTM PNEUMATIC CNTRL STAINLESS STEEL 316 - CLIPPARD PQS-ME08W OR EQV

60 8 EXHAUST MUFFLER W/ FLOW CONTROL, MALE, 3/8"NPT PNEUMATIC CNTRL BRASS - PARKER 04506-0060 OR EQV. ADJUST TO PREVENT WATER HAMMER.

61 1 FILTER-REGULATOR, 1/2" NPT, NOM 0-125 PSI RANGE, WITH GAUGE, MIN 40 MICRON, METAL BOWL PNEUMATIC CNTRL COML - TO REGULATE AND FILTER AIR SUPPLY TO PNEUMATIC CNTRL SYS, PARKER 07E34B18AC OR

EQV

62 5 INDICATOR, AIR, RED 7-PIN TYPE, 1/4" TUBING SIZE, MIN 125 PSIG PNEUMATIC CNTRL COML - CLIPPARD IND-3-RD OR EQV

63 1 MUFFLER, 1/2" NPTM, MIN 125 PSIG PNEUMATIC CNTRL COML - MC MASTER CARR 4450K4 OR EQV

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

SOME PARTS APPEAR ON MORE THAN ONE ITEM# DUE TO DRAWING REVISIONS. ADD ALL FOR

TOTAL REQD QTY.

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

8 OF 41CONCEPTUAL DRAWING

X-99482 ORIGPARTS LIST (CONT)

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

64 2 PLUG, MALE 1/4 IN NPTM PNEUMATIC CNTRL STAINLESS STEEL 316 - PNEUMADYNE SPG-1/4 OR EQV

65 1 PLUG, MALE, 3/8 IN NPTM PNEUMATIC CNTRL STAINLESS STEEL 316 - PNEUMADYNE SPG-3/8 OR EQV

66 9 PUSH QUICK CONNECTOR, BULKHEAD UNION, 1/4"TUBE TO 1/4"TUBE PNEUMATIC CNTRL STAINLESS STEEL - CLIPPARD PQS-BU08 OR EQV

67 6 PUSH QUICK CONNECTOR, MALE, 1/4"TUBE TO #10-32 PNEUMATIC CNTRL STAINLESS STEEL - CLIPPARD PQS-MC08N OR EQV

68 6 PUSH QUICK CONNECTOR, MALE, 1/4"TUBE TO 1/4"NPT PNEUMATIC CNTRL STAINLESS STEEL - CLIPPARD PQS-MC08Q OR EQV

69 11 PUSH QUICK CONNECTOR, MALE, 1/4"TUBE TO 3/8"NPT PNEUMATIC CNTRL STAINLESS STEEL - CLIPPARD PQS-MC08W OR EQV

70 4 TEE, BRANCH, PUSH-QUICK, 1/4" TUBE TO MALE, 3/8"NPT PNEUMATIC CNTRL STAINLESS STEEL - CLIPPARD PQS-BT08W OR EQV

71 1 TUBE, COIL FLEX, 1/4" ID/ W/NPT SWIVEL ENDS, APPRX 25' MIN EXTENDED LNGTH PNEUMATIC CNTRL POLYURETHANE - ROLLING MNFLD VLV CNTRL, W/ STRAIN RELIEF. COIL NOT SHOWN IN DWG, FLEXCOIL PR14 OR

EQV, RED COLOR

72* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 1 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - DRAIN VLV IND TUBING

73 1 TUBING, 1/4 IN OD, 105 PSIG MWP, 0.02 WALL, APPROX 3 FT LENGTH PNEUMATIC CNTRL STAINLESS STEEL 304 ASTM 269 VENT VLV TUBING ON ROLLING MANIFOLD, MCMASTER CARR 8989K191 OR EQV

74 1 TUBING, 1/4 IN OD, 105 PSIG MWP, 0.02 WALL, APPROX 5 FT LENGTH PNEUMATIC CNTRL STAINLESS STEEL 304 ASTM 269 CONTROL AIR SUPPLY TUBING, MC MASTER CARR 8989K191 OR EQV

75* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, 125 PSIG MIN, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A01 - PUMP INLET DIVERT VLV TUBING

76* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, 125 PSIG MIN, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A03 - PUMP OUTLET DIVERT VLV TUBING

77* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, 125 PSIG MIN, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A04 - PUMP OUTLET DIVERT VLV TUBING

78* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - PUMP CONTRL SUPPLY TUBE

79* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - PUMP INLET VLV CONTRL TUBIN G

80* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - PUMP OUTLET VLV CONTRL TUBING

81* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - AIR ON IND TUBING

82* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - DRAIN VLV CONTROL TUBING

83* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - BLOWDOWN CNTRL VLV TUBING

84* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - INTERLOCK VLV TUBING TUBING

85* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - DRAIN VALVE INDICATOR TUBING

86* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - PUMP INDICATOR TUBING

87* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - AIR PILOT CONNECTION TUBING

88* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A02 - PUMP INLET DIVERT VLV TUBING

89* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A05 - PUMP AIR VLV TUBING

90* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A06 - BLOWDOWN AIR VLV TUBING

91* 1 TUBING, 1/4 IN OD, 105 PSIG MWP, APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - A07 - DRAIN VLV TUBING TUBING

92* 1 TUBING, 1/4 IN OD, 105 PSIG MWP," APPROX 2 FT LENGTH PNEUMATIC CNTRL POLYURETHANE - AIR VLV IND TUBING

93 1 TUBING, 3/8 IN OD, 0.028 WALL, 105 PSIG MWP, APPROX 50 FT LENGTH PNEUMATIC CNTRL STAINLESS STEEL 316 ASTM 269 A09 - VENT VALVE AIR SIGNAL LINE, ADD FITTINGS AS REQD. MAY BE ROUTED AS NEEDED, MCMASTER CARR 89995K86 OR EQV

94 1 VALVE, AIR PILOTED, 3-WAY 2-POS, SPRING RETURN, 3/8 NPTF, 115 PSIG MWP PNEUMATIC CNTRL COML - CLIPPARD MMA-33WAS OR EQV

95 3 VALVE, PUSH/PULL, 3-WAY 2-POS, 3/8 NPTF, MIN 115 PSIG PNEUMATIC CNTRL COML - CLIPPARD MMV-P3QD OR EQV

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

9 OF 41CONCEPTUAL DRAWING

X-99482 ORIGPARTS LIST (CONT)

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

96 1 VALVE, PUSH/PULL, 4-WAY 2-POS, 3/8 IN NPTF, MIN 115 PSIG PNEUMATIC CNTRL COML - CLIPPARD MMV-P4QD OR EQV

97 2 VALVE, ROTARY, AIR 4-WAY, 2 POS, 4 PORT, 3/8" NPTF, 140 PSIG MWP PNEUMATIC CNTRL COML - ARO M113LR OR EQV

98 1 ADAPTER, BUSHING, 2 IN NPT X 3/4IN NPT, CLASS 3000 PIPING STAINLESS STEEL 316 ASTM A351 MC MASTER CARR PN 4443K425 OR EQV, 3000 PSI

99 1 BUSHING, ADAPTER 1-1/4" TO 1/4" NPT, CLASS 1000 PIPING STAINLESS STEEL 316 MSS-SP-114

100 7 COUPLER, PIPE, 1-1/4" NPT, MIN CLASS 150 PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114 COMPRESSED AIR PIPING

101 1 COUPLER, PIPE, 1/2" NPT, CLASS 1000 PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114

102 3 COUPLER, PIPE, 2" NPT, CLASS 1000 PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114

103 3 ELBOW, 1-1/4" NPT , CLASS 150 PIPING STAINLESS STEEL 304 ASTM A351, MSS-SP-114 COMPRESSED AIR PIPING

104 5 ELBOW, 1-1/4" NPT, CLASS 3000 PIPING STAINLESS STEEL 316 ASTM A182, ASME B16.11

105 1 ELBOW, 1/2" NPT, CLASS 150 PIPING STAINLESS STEEL 316 ASTM A351, MSS-SP-114

106 2 ELBOW, 2" NPT, CLASS 3000 PIPING STAINLESS STEEL 316 ASTM A182, ASME B16.11

107 2 ELBOW, 2" NPT, MIN CLASS 150 PIPING STAINLESS STEEL 316 ASTM A351, MSS-SP-114 VENT PIPING

108 1 ELBOW, SWIVEL, 1-1/4 NPTF TO NPSF AIR HOSE, MWP 150 PSI COMPRESSED AIR SVC PIPING COML - MCMASTER-CARR 53845K56, PARKER 2207 SERIES OR EQV. ADAPT AS NEEDED.

109 1 ELBOW, SWIVEL, 2" NPT, 150 PSIG MWP PIPING BRONZE, COML - MCMASTER CARR 53845k58 OR EQV

110 1 GAUGE, PRESSURE 0-400 PSI SCALE, 10 PSI GRADUATION MARKS PIPING COML - TO BE REPLACED WITH GOVT FURNISHED EQUIP, METCAL PROGRAM AFTER ACCEPTANCE

111 1 HOSE, AIR, 1-1/4" NOMINAL,MIN 150 PSI RATING, APPROX 15 FT LONG PIPING RUBBER, OIL RESISTANT - ADD ENDS OR ADAPTERS AS REQD FOR USE WITH SWIVEL ELBOWS (E.G. PARKER)

112 1 HOSE, WATER, 2", APPROX 15 FT LONG, NPT ENDS PIPING RUBBER, OIL RESISTANT - W/STRAIN RELIEF

113 1 LIQUID LEVEL SIGHT PLUG, 2 IN NPTM, 500 PSI PIPING STAINLESS STEEL - LDI IND LSP51-09 OR EQV

114 3 NIPPLE, 1-1/4" NPT, 2 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

115 6 NIPPLE, 1-1/4" NPT, 4 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

116 3 NIPPLE, 1/2 IN NPT, 1/2 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

117 2 NIPPLE, 1/2 IN NPT, 6 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

118 2 NIPPLE, 1/2 IN NPT, APPROX 8 IN LENGTH,SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

119 6 NIPPLE, 2" NPT, 2 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

120 1 NIPPLE, 2" NPT, 4 IN LENGTH, MWP 150 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733 BENCH VENT PIPING

121 4 NIPPLE, 2" NPT, 4 IN LENGTH, SEAMLESS, MWP 300 PSI PIPING STAINLESS STEEL 316 ASTM A312, A733

122 2 PIPE, 1-1/4 NPT, SCH 40, 2 FT LENGTH, SEAMLESS, MWP 150 PSIG PIPING STAINLESS STEEL 304 ASTM A312 BENCH AIR PIPING

123 7 PIPE, 1-1/4 NPT, SCH 40, 6 FT LENGTH, SEAMLESS, MWP 150 PSIG PIPING STAINLESS STEEL 304 ASTM A312 BENCH AIR PIPING

124 1 PIPE, 1-1/4" NPS COPED TO SUIT, NPT THREAD, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312

125 1 PIPE, 1-1/4" NPT, SCH 40, APPROX 11"LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

126 1 PIPE, 1-1/4" NPT, SCH 40, APPROX 14"LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

127 1 PIPE, 1-1/4" NPT, SCH 40, APPROX 20"LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

128 3 PIPE, 1-1/4" NPT, SCH 40, APPROX 8"LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

10 OF 41CONCEPTUAL DRAWING

X-99482 ORIGPARTS LIST (CONT)

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

129 2 PIPE, 2" NPS, SCH 40, 12" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

130 2 PIPE, 2" NPS, SCH 40, 16" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

131 2 PIPE, 2" NPS, SCH 40, 4" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

132 2 PIPE, 2" NPS, SCH 40, 8" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

133 2 PIPE, 2" NPS, SCH 40, 8" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

134 1 PIPE, 2" NPS, SCH 40, 8" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 COPE AND WELD ONE END, NPT OTHER END

135 4 PIPE, 2" NPT, SCH 40, 6 FT LENGTH, MWP 150 PSIG PIPING STAINLESS STEEL 304 ASTM A312 BENCH VENT PIPING

136 3 PIPE, 2" NPT, SCH 40, APPROX 14"LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

137 2 PIPE, 2" NPT, SCH 40, APPROX 18" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

138 1 PIPE, 2" NPT, SCH 40, APPROX 8" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 CUT AND THREAD TO SUIT

139 1 PIPE, 3" NPS, SCH 40, 34" LENGTH, FIXED MANIFOLD, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 WELDED CONNECTIONS, CUT HOLES TO SUIT

140 1 PIPE, 3" NPS, SCH 40, 37" LENGTH, SEAMLESS PIPING STAINLESS STEEL 316 ASTM A312 WELDED CONNECTIONS

141 4 PLATE, 1/4" THK, 3" DIA DISK, END CAP PIPING STAINLESS STEEL 316 ASTM A240/A666-10

142 1 REGULATOR, ADJUSTABLE, AIR PRESSURE, MIN 1" NPT WITH GAUGE PIPING COML - PARKER 09R, P3NR, OR EQV, AIR PRESSURE CAPY 150 PSI OR GREATER. 1" MIN PORT, ADAPT

PIPE AS REQD

143 1 REGULATOR, AIR PRESSURE, 1-1/4" NPT WITH GAUGE PIPING COML - COILHOSE 8808G OR EQV, AIR PRESSURE CAPY 150 PSI OR GREATER

144 1 SNUBBER/GAUGE VIBRATION DAMPER, 1/2 NPTMxF, 0.015 IN ORIFICE, MWP 300 PSIG PIPING BRASS - MC MASTER CARR PN 3820K33, OR EQV

145 2 TEE, 1-1/4" NPT, CLASS 1000 PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114

146 1 TEE, 1/2" NPT, MWP 150 PSIG PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114 COMPRESSED AIR SERVICE

147 2 TEE, 2" NPT, CLASS 1000 PIPING STAINLESS STEEL 316 ASTM A182, MSS-SP-114

148 1 TEE, REDUCING, 2" X 1/2" NPTF THREADED, CLASS 3000 PIPING STAINLESS STEEL 316 ASTM A182, ASME B16.11 SHAW TW2.00X.50-TH3000#316 OR EQV

149 1 UNION, 1-1/4" NPT, 1000 PSI MIN, LEAKPROOF DESIGN PIPING STAINLESS STEEL 316 - FERGUSON IS6BSTU1MSP114 OR EQV

150 2 UNION, 2" NPT, 1000 PSI MIN, LEAKPROOF DESIGN PIPING STAINLESS STEEL 316 - FERGUSON IS6BSTU1MSP114 OR EQV

151 2 VALVE, 3-WAY "T-PORT" DIVERTER, AIR ACTUATED, 2" NPT PIPING STAINLESS STEEL - VALWORX 5239 OR EQUIV

152 2 VALVE, BALL, 1-1/4 IN NPTF, 3-PC, AIR ACTUATED, SPRING RTN, N.C./F.C. PIPING STAINLESS STEEL - VALWORX 5225 SERIES OR EQUIV, SPRING RETURN, NORMALLY CLOSED (FAIL CLOSED)

153 1 VALVE, BALL, 1-1/4 IN NPTF, MWP 500 PSIG, LOCKABLE PIPING STAINLESS STEEL - MC MASTER CARR 46325K32 OR EQV

154 2 VALVE, BALL, 2 IN NPTF, 3-PC, AIR ACTUATED, SPRING RTN, N.O/F.O., MWP 500 PSIG PIPING STAINLESS STEEL - VALWORX 5225 SERIES OR EQUIV, SPRING RETURN, NORMALLY OPEN (FAIL OPEN)

155 8 VALVE, BALL, 2 IN NPTF, STANDARD PORT, MWP 500 PSIG PIPING STAINLESS STEEL - MC MASTER CARR PN 46325K34 OR EQV

156 1 VALVE, CHECK 1-1/4" NPT, SPRING LOADED PIPING BRASS ASTM A351 CIRCLE SEAL BRASS OR EQV, ZERO LEAKAGE

157 2 VALVE, CHECK, 2 IN NPT, SPRING LOADED, ZERO LEAKAGE. MWP 500 PSIG, VITON SEAL PIPING BRASS - CIRCLE SEAL 200 SERIES BRASS OR EQV, STD CRACK PRESS

158 1 VALVE, GLOBE, 1/2" NPT, MWP 300 PSIG PIPING BRASS MSS-SP-80

159 1 VALVE, RELIEF, ADJUSTABLE, 1/2" NPT PIPING BRASS SET PRESSURE PER NOTES HEREIN, INLET/OUTLET CONNECTIONS TO SUIT, FUEL OIL COMPAT, MCMASTER-CARR 4703K54 OR EQV

160 120 BOLT, 1/4"-20 UNC 2A X 1" LENGTH FASTENER STAINLESS STEEL 316 ASTM F593, ASME B18.2.1 QTY AS REQD

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

11 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

ITEM # QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

161 15 BOLT, 1/4"-20 UNC 2A, 3/4" LENGTH FASTENER STAINLESS STEEL 316 ASTM F593, ASME B18.2.1 QTY AS REQD

162 8 NUT, LOCK, 1/2" -13 UNC 2B, W/ NYLON INS FASTENER STAINLESS STEEL 316 ASTM F594, ASME B18.2.1 QTY AS REQD

163 135 NUT, 1/4"-20 UNC 2B FASTENER STAINLESS STEEL 316 ASTM F594, ASME B18.2.1 QTY AS REQD

164 4 SCREW, HEX CAP, 1/2-13 UNC 2A X 3" LENGTH FASTENER STAINLESS STEEL 316 ASTM F594, ASME B18.2.1 QTY AS REQD

165 251 SCREW, SELF TAPPING, #10, 1/2" LENGTH FASTENER STAINLESS STEEL 316 ASTM F594, ASME B18.2.1 OK TO SUB SEALED RIVET, QTY AS REQD

166 8 WASHER, NOM 1/2" ID FASTENER STAINLESS STEEL 316 USS STANDARD QTY AS REQD

167 232 WASHER, NOM 1/4" ID, 3/4" OD FASTENER STAINLESS STEEL 316 USS STANDARD QTY AS REQD

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

12 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

PARTS LIST (CONT)

ADDITIONAL PARTS NOT CAPTURED IN PREVIOUS PARTS LISTINGS:

ITEM QTY TITLE CATEGORY MATERIAL SPECS COMMENTS

--- AS REQD ROOM TEMP VULCANIZING (RTV) SEALER STRUCTURAL COML CHLORINE/SALTWATER/OIL RESIST, FOR PAN JOINTS, FASTENER HOLES, AND OTHER PENETRATIONS --- AS REQD SCREWS, NUTS, BOLTS STRUCTURAL STAINLESS STEEL 316 ASTM F593, 594 NOT ALL FASTENERS ARE SHOWN --- AS REQD STRUT HARDWARE STRUCTURAL STEEL "UNISTRUT" OR EQUAL JOINERS, BRACKETS, ETC

--- AS REQD STRUT MATL STRUCTURAL STEEL "UNISTRUT" OR EQUAL

--- AS REQD GASKET MATL STRUCTURAL COML CHLORINE/SALTWATER/OIL RESIST, FOR PAN JOINTS, AND OTHER OPEN SEAMS

--- AS REQD EXTRA TUBING, PIPE, HOSE PIPING AS REQD AS REQD BY INSTALLATION

NONE

ASTERISK (*) INDICATES PART IS NOT CALLED-OUT OR IS NOT SHOWN IN DRAWINGS

ISO VIEW, ASSEMBLY

C

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

13 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

-- GRATE HIDDEN FOR CLARITY --

CONTINUED ON FOLLOWING SHEET

FIXED (INLET) MANIFOLD ASSY

(NOT VISIBLE)

SEE SHT 23

INLET END OF BENCH

WELD OR FASTEN COAMING TO TROUGH

FASTEN EVERY 3 INCHES OR AS REQD

SEAL WITH RTV

(TYP)

-- G

RATE HIDDEN FO

R CLARITY --

WATER INLET

AIR INLET AND SHUT-OFF

CONTROL STAND

CONTROL PANEL

CUT TO SUIT20

SUMP TANK (EXISTING)

PUMP (EXISTING)

ISO VIEW, ASSEMBLY

C

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

14 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

ROLLING MANIFOLD ASSEMBLY

SEE SHEETS 23-24

CONTINUED FROM PREV SHEET

GRATE, 1 IN DEEP, 1.5 IN GRID, APPROX 3 FT X 10 FT17

EXTRA STRAIGHT PAN SECTION

FOR FUTURE USE

WITHOUT CORNER ASSEMBLY

OR AS SPARE

(INCLUDED IN MATL LIST TOTALS)

GRATING HIDDEN

FOR CLARITY144"

TYP GRATE ASSY

Q

Q

SECTION Q-Q

TYP GRATE STANDOFF

56HOLE/CBORE TO SUIT

STANDOFFS FOR DRAINAGE

LOCATE AND QTY STANDOFF ASSEMBLIES AS NEEDED

APPROX AS SHOWN

NONE

OUTLET END OF BENCH

ADJUST AS REQD FOR ROUGH FLOOR SURFACE

CUT GRATING PIECES IN HALF

TO FACILITATE INSTALLATION AND REMOVAL

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

15 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

PLAN VIEW

SCALE 1:40

ELEVATION VIEW SCALE 1:40 D

D

SECTION D-D

CONTROL STAND

ASSEMBLY

PROTECTIVE

CLEAR

SHIELD,

HINGED

PROTECTIVE POLYCARBONATE

SHIELD

434" SLOPE APPROX 1 IN PER 10 FT

G

DETAIL G

BUMPER ASSY

SCALE 1:20

18"

408GRATING NOT SHOWN

ROLLING MANFLD ASSY

FLOOR

(MAY BE ROUGH AND NON LEVEL)

FLOOR

36" TYP 39 3/4" TYP

'-2

26" TANK TOP (ACTUAL)

27 1/4" TO SKIRT RETAINER

'-1

"20 '-6

ENSURE AREA UNDER BENCH

IS CLEAR OF PIPE/TUBE

TO ALLOW MOVEMENT OF

COLLECTION TANK.

AS NOTED

NO PAN SLOPE

39"TOP EDGE HEIGHT

27 1/2" 28 1/2"

32 1/4"

FIXED MANFLD

ASSY

(INSIDE)

HINGED TO SUIT

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

16 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

BOLT, RIVET OR SPOT WELD

LEG SUPPORT TO LEGS

AS APPR.

165 11 PL, TYP

MODIFIED LEG SHOWN, BASIC LEG SIMILAR

(ROLLING MANIFOLD, GRATING, ETC HIDDEN

FOR CLARITY)

45 UPPER EDGE

AS NOTED

ADD GASKET MATL

SEAL WITH RTV

AS REQD

1622X

1662X

SEAL WITH RTV

(TYP)

ELEVATION VIEW

SCALE 1:40

B

B

SECTION B-B

TYP LEG STATION ASSY

SCALE 1:8

A

A

SECTION A-A

TYP 4 PLCS

SCALE 1:4

E

DETAIL E TYP LEG ASSY

SCALE 1:2

11 10 10 10

160 4 PLCS

163 4 PLCS

167 2X 4 PLCS

VA

RI

ES

D

U E

TO

P

AN

S

LO

PE

11 11

44'-7"

90°

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

17 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

6 3/4"

6"

24"

96"

96"

36 1/8"

36 1/8" 6"

64 5/8"

1.2°

146°

124°

43PLAN VIEW PC

43ISOMETRIC VIEW PC

SLOPE DOWNWARD

TOWARD SUMP

ALL SEAMS1/16 MIN

36DETAIL PC

35DETAIL PC

97 5/8"

97 5/8"

6"

24 1/8"

64 5/8"

146°

124°

TYP 1/16 MIN

TYP 1/16 MIN

WELD SEAMS OR BEND

AS REQD TO MFR THIS

SHAPE

37PROFILE SAME AS PC

1/2" = 1'

90°

THIS SECTION MAY BE LEVEL

OR SLOPED TOWARD SUMP BUT

WATER SHALL NOT POOL IN THIS AREA

37PROFILE SAME AS PC

43SIDE VIEW PC

SEE NEXT SHEET FOR ASSEMBLY DETAILS

PLAN VIEW

CORNER STRUCTURE ISOMETRIC VIEW

CORNER ASSEMBLY

SUPPORT STRUCTURE

D

C

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

18 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

4 4

5 4

32"

35"

36 HIDDENPC

43 HIDDENPC

35 HIDDENPC

TRIM TO FIT

TYP ALL JOINTS 1/8 MIN

HIDDEN35PC

HIDDEN43PC

HIDDEN36PC

EXTRA LEG/BRACE ASSY

TO ALLOW TRANSFORMING

BENCH TO STRAIGHT CONFIGURATION

3/4"= 1'

25 1/2"

SLOPE STRUCTURE IN THIS SECTION

TO SUIT

SEE SHEET 20

FOR TYP LEG SUPPORT ASSY

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

19 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

ORTHOGRAPHIC VIEWS, STRUCTURE AT INLET END OF TEST BENCH

ALL VIEWS: PIPING SUPPORT

PLACEMENT AND LENGTHS SHOWN ARE

REPRESENTATIVE AND MAY BE CHANGED

AS NECESSARY DURING ASSEMBLY

MOUNT AND JOIN PIPING SUPPORT WITH

APPROPRIATE HARDWARE, AS REQD.

O EVEN SPC, 7 PLCS, TYP

1" = 1'

TYP 1/8 MIN

36 1/4"

28 7/8"

15"

60"

6" 2"

3 TRIM AS REQD

TYP1/8 MIN

87"

FLOOR

3 TRIM AS REQD

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

20 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

MATL TO BE REMOVED

FROM MODIFIED LEGS

TO CLEAR ROLLING MANFLD ASSY

1-1/2" = 1'

HOLE LOCS

SAME AS

OTHER LEGS

DETAIL, TYP LEG SUPPORT

33 SHEET, 12 GA, 20"X40", LEG SUPPORT7

BEND 90 DEG TYP

3" INSIDE

8"

39 1/2"

36 3/8"

DETAIL TYP LEG DETAIL TYP MODIFIED LEG

R 1/2"

2 1/2"

1"

BEND 90v TYP

TYP 12' BOTTOM PAN SECTION

SCALE 1:8

36 3/8" OUTER

90° TYP5 3/4"

37DETAIL PC

1 7/8"

6"

1"

5 1/2"

3/4"

2 1/4"

39 1/2"

MFR PC AND

USING SAME PROFILE MATL

1 1/2"

5/8"

3"

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

21 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

DRAIN SUMP OPENING

DRILL HOLES FOR SKIRT

RETAINERS TO SUIT

NOTE OTHER DRAIN PAN PIECES

( PART ) ARE SIMILAR: DELETE

MITERED END, OPENING FOR

DRAIN SUMP, AND RELATED

SCREW HOLES,

1" = 1 '

DRILL HOLES FOR

SCREWS/RIVETS AS REQD (TYP)

46PLAN VIEW, BOTTOM PAN, PC DRAIN END

36 1/4"

144"

PROFILE VIEW BOTTOM PAN

89.5° MITER TO SUIT

5 3/4"

22"

11"

6 1/8"

R 1"

ISO VIEW (BOTTOM)

DETAIL OF DRAIN SKIRT ASSY

22 1/2" 14"

2 1

DRILL HOLES TO SUIT

APPROX 2 IN APART

7 1/4"

36"

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

22 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

LOCATE AND SIZE

HOLE TO SUIT PIPING

CONNECTIONS

1-1/2" = 1'

SEE SHEET 28 FOR NOMINAL

SHEET METAL PATTERNS

DRILL FOR 1/4" SCREW

11 PL, EVEN SPC

DRILL FOR 1/4-10 BOLT

10 PL, EVEN SPC

FRONT VIEW SIDE VIEW

SIDE VIEWFRONT VIEW

ISO VIEW

ISO VIEW

DRILL FOR 1/4" SCREW

4 PL, EVEN SPC,

TYP

36 1/8" INSIDE

39 3/4"

1 5/8"

11 3/8" 10 3/4"

39 3/4"

5/8"

36 3/8"

1 3/4"

7"6 3/4"

1 3/4"

11"

1 3/4"

3 5/8"

1 5/8"

42 PC

41PC

1/16 TYP

1/16 TYP

5/8"

1 3/4"

10 1/4"

DRILL FOR 1/4" SCREW

4 PL, EVEN SPC,

TYP

DRILL FOR 1/4" SCREW

11 PL, EVEN SPC

42 PC 42 PC

41PC

41PC

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

23 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

4 SEE DETAIL SHT 24

LEFT ISO VIEW

RIGHT ISO VIEW

(PIPING NOT SHOWN)

PLACEMENT OF PIPE HANGERS

SHALL BE ADJUSTED AS REQUIRED

SUCH THAT MANIFOLD IS CENTERED

ON ROLLING BASE AND ADEQUATELY

SUPPORTED23

SIGHT GLASS TO

VERIFY WHEN HOSES ARE FULL

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

24 OF 41CONCEPTUAL DRAWING

X-99482 ORIGORTHOGRAPHIC VIEWS, ROLLING MANIFOLD STRUCTURE

SEE SHEET 28 FOR

NOTIONAL SHEET METAL PATTERNS

ALL VIEWS: PIPING NOT

SHOWN FOR CLARITY

TYP1/8 MIN

TYP 1/8 MIN

TYP1/8 MIN

1-1/2" = 1'

R 1/4"BEND 90v TYP

DRILL FOR 1/4"-20 BOLT TYP

23 3 PLCS

PLAN VIEW

SIDE VIEW

FRONT VIEW

SCALE 1:2

30DETAIL PC

2 1/4"

4"

1 1/4"1 3/8"

8 1/2"

3 3/8"

6 7/8"

18 3/8"

9" 9"

41 7/8"

8 1/4" 12" 6" 9"

5"

3/4" TYP

9 1/4" TYP 9" TYP

3 1/4"

5" 38 1/2"

50"

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

25 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

FIXED (SUPPLY) MANIFOLD

PIPING NOT SHOWN FOR CLARITY

SEE SHEET 36 FOR PIPING

DETAIL

C

C

1" = 1'

END PLATE AND HANGERS

BOTTOM ISO VIEW

TYP 1/8 MIN

SEAL SKIRT REATIANER/PAN JOINT

WITH RTV AND RUBBER GASKET

AS REQD

PLAN VIEW

22 3 PL 25 2 PL

BENCH EMPTIES INTO EXISTING

COLLECTION TANK

AIR AND WATER PIPING NOT SHOWN FOR CLARITY

17"

13"

9"

6"

PLACEMENT OF PIPE HANGERS

SHALL BE ADJUSTED AS REQUIRED

SUCH THAT MANIFOLD IS CENTERED ON

BASE PLATE AND ADEQUATELY SUPPORTED,

AND HANDLES ARE FREE TO OPERATE.

6 3/8" 10"

15 3/8"

24 3/8"

31"

9 TYP

161 15 PLCS

SAFETY SHIELD, GRATING AND PIPING NOT SHOWN

FOR CLARITY

SIDE VIEW DETAIL, DRAIN SUMP AND SUPPLY MANIFOLD

161 BOLT, 1/4"-20 UNC 2A, 3/4" LENGTHTYP

163 NUT, 1/4"-20 UNC 2B

SAFETY SHIELD, GRATING AND PIPING NOT SHOWN

FOR CLARITY

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

26 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

DETAIL,

SUPPLY MANIFOLD PLATE

SCALE 1:8

M M

SECTION M-M39 3/4"

21 5/8"

5 7/8"

2 1/4"

C-C (SHEET 25)

SCALE 1:12

C

COAMING, DETAIL C

SCALE 1:2

DETAIL, SIDE SHEET CUTOUT COAMING

SCALE 1:8

45° TYP

28"

5 1/2" TYP

FABRICATE FROM 1X2 CHANNEL

CUT AND MITER TO SUIT

REMOVE SHARP EDGES/BURRS

WELD OR RIVET IN PLACE

TYP1/8 MIN

TYP 1/8 MIN

DRILL FOR 1/4-20 UNC 2A BOLT

15 PL EVEN SPC

AS NOTED

165 QTY AS REQD

2 TYP 2 PLC

1 TYP 2 PLC

R 1/4"

BEND DOWN 90v

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

27 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

O1/4" 3PL

BOLT IN PLACE

1/4"-20 BOLT/NUT

EXAMPLE SHEET METAL PATTERN

BUMPER POST

5 3/4"2"

2"

2"

2"

4 7/8" 3" 1"

1 1/4"

2"

6 7/8" 7/8"

SHEET METAL PATTERNS ARE FOR REFERENCE ONLY. ENSURE

DIMENSIONS OF FINAL FABRICATED PARTS MATCH THOSE CALLED OUT

ON PART DRAWINGS IN THIS DOCUMENT.

R 1/2" TYP

O1/4"

TYP1/8 MIN

1"

3" = 1 '

TYP 1/8 MIN

TOP VIEW

BUMPER ASSY

SIDE VIEW

BUMPER ASSY

FRONT VIEW

BUMPER ASSY

ISO VIEW

BUMPER ASSY

3"

6"

5"

2 1/8"

1 1/4"

R 1/2" TYP

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

28 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

FAR ENDPLATE SHEET METAL PATTERN

36 3/8"

6"

39 9/16"

1/2"

1/2" TYP

7/32"

1 9/16"

INLET ENDPLATE SHEET METAL PATTERN

ALL BENDS

DOWN 90 DEG,

1/4" RAD

39 9/16"

36 3/8"

11"

1/

2"

1/4"

1-1/2" = 1'

LOCATE HOLES TO SUIT PIPING

1 3/4"

1 3/4" 1 7/8"

1/2"

ALL BENDS

DOWN 90 DEG,

1/4" RAD

ALL BENDS

DOWN 90 DEG,

1/4" RAD

SHEET METAL PATTERN

ROLLING MANIFOLD BASE

49 3/4"

33 3/8"33 3/8"

8 3/8"

25 3/8"

R 1" TYP CORNERS

4" TYP

3/4" TYP2 1/2" TYP

2 1/2" TYP

8" TYP

O 1/4" TYP 8 PLCS

O 1/2" TYP 4 PLCS

SHEET METAL PATTERNS ON THIS SHEET ARE FOR REFERENCE ONLY. ENSURE DIMENSIONS OF FINAL PARTS MATCH THOSE CALLED OUT ON PART DRAWINGS IN THIS DOCUMENT OR AS REQD TO FIT.

3" TYP

4 3/4"

4 3/4" TYP

4" TYP

R 1" TYP

52 3/4"

50 7/8"

16"

1/2"

1 7/8"

B

A

B

SHEETSCALE:

SIZE CAGE CODE DRAWING NO. REV

A

B

C

D

82522

29 OF 41CONCEPTUAL DRAWING

X-99482 ORIG

1"=1'

PLAN VIEW

CONTROL STAND ASSY

PIPING AND DOOR NOT SHOWN FOR CLARITY

STRUT AND STRUCTURE MAY BE ADJUSTED TO SUIT

ASSEMBLE WITH MFR RECOMMDNED HARDWARE AS REQD

SIDE VIEW

CONTROL STAND ASSY

ELEVATION VIEW

CONTROL STAND ASSY

40" 18 3/8"

12"

29"

18"

29" 32 1/4"

43 1/8"

35"

4"

B

A

B

SHEETSCALE:

SIZE CAGE…