DRAFT 6.4.1 Design-Construction Drawings_PN89906 CP 21 AREA_BINDING 02_FINAL SET_Sign1.pdf
PDF 45 MB Posted
- Attached to
- ACC Replacement 21 Area Initial Outfitting Project Federal contract opportunity
- Solicitation number
- W9127S21Q6003
About this file
This notice provides information about an upcoming federal contract opportunity. The U.S. Army Corps of Engineers Little Rock District intends to issue a solicitation for an initial outfitting project at Camp Pendleton, California to replace Area 21. The simplified acquisition procedures of FAR Part 13 and commercial items procedures of FAR Part 12 will apply to this requirement, which will be issued as a request for quote. This will be a total set-aside for Service-Disabled Veteran-Owned Small Businesses. The estimated contract value is between $5 million and $10 million. Interested parties can submit questions through July 18, 2021 regarding solicitation number W9127S21Q6003, which is anticipated to be issued on July 23, 2021. The work involves design-construction drawings for the ACC Replacement 21 Area Initial Outfitting Project.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| DRAFT Copy of 6.7 PRICE SCHEDULE_PN89906 CP 21 Area.xlsx | XLSX spreadsheet | |
| DRAFT 6.4.2 Drawings (FFE)_PN89906 CP 21 AREA_BINDING 03_FINAL SET_Sign1.pdf | ||
| DRAFT Program for Design.pdf | ||
| DRAFT 6.7.1 DOR SPECS_PN89906_E2.1_EQ_Cutbook_A1000-L8520.pdf | ||
| DRAFT 6.5.3 Program For Design_PN89906 CP 21 Area.pdf | ||
| DRAFT 6.5.1 Project Room Contents (FFE)_PN89906 CP 21 Area.pdf | ||
| DRAFT SOW V2 PN89906 CP 21 Area IOT Standalone Requirements Document.pdf | ||
| DRAFT GC_Schedule.pdf | ||
| DRAFT 6.7.1 DOR SPECS_PN89906_E2.2_EQ_Cutbook_M0005-X6610 (3).pdf | ||
| DRAFT Room by Room.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
LA
TO
R Y
C A
R E
C E
N
TE
R R
E P
LA
C
E M
E N
T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
W
E S
T
NA
VF
AC
P
AC
IF
IC
H
IG
HW
AY
, S
AN
D
IE
GO
C
A
EE
MC
B
CA
MP
P
EN
DL
ET
ON
A
RE
A
SV/AE
MP PM BEW
AS NOTED
P-9906
FY-20 MCON | P-9906
AMBULATORY CARE CENTER REPLACEMENT
Marine Corps Base - 21 Area Camp Pendleton South, CA
NAVFAC FACILITIES ENGINEERING COMMAND
SOUTHWEST
DALLAS, TX
HKS l WSP JOINT VENTURE
CIVIL
LANDSCAPE
ARCHITECTURAL
MECHANICAL
PLUMBING
ELECTRICAL
TELECOMMUNICATION
FIRE PROTECTION
THE INNOVA GROUP
AUSTIN, TX
MEDICAL EQUIPMENT
focusEGD
DALLAS, TX
WAYFINDING
PROTECTION ENGINEERING CONSULTANTS
SAN ANTONIO, TX
ANTI-TERRORISM / FORCE PROTECTION
FINAL SUBMITTAL
ALLIANCE CONSULTING GROUP
ALEXANDRIA, VA
COST ESTIMATE
YOUNG + CO., INC.
SAN DIEGO, CA
INTERIOR DESIGN
CAGELY & ASSOCIATES, INC.
ROCKVILLE, MD
STRUCTURAL
LAMMERS & ASSOCIATES
RESTON, VA
MATERIALS MANAGEMENT
ACCESS BY DESIGN
DALLAS, TX
ACCESSIBILITY
FIRE ALARM/FIRE PROTECTION/PLUMBING/MECHANICAL/ELECTRICAL/TECHNOLOGY
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
BINDING 02
EW
MG
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
JULY 07, 2020
6/
/2
3:
:1
PM
G-001
CO
VE
R
SH
EE
T
07/07/2020
FI
NA
L
SU
BM
IT
TA
L
18303485 1 393
07/07/2020
BINDING INDEX
BINDING 01
BINDING 02
GENERAL INFORMATION
FIRE ALARM
FIRE PROTECTION
PLUMBING
MECHANICAL
ELECTRICAL
TELECOMM
GENERAL INFORMATION
LIFE SAFETY
CIVIL
LANDSCAPE
STRUCTURAL
ARCHITECTURAL
INTERIOR DESIGN
WAYFINDING
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
LA
TO
R Y
C A
R E
C E
N
TE
R R
E P
LA
C
E M
E N
T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
W
E S
T
NA
VF
AC
P
AC
IF
IC
H
IG
HW
AY
, S
AN
D
IE
GO
C
A
EE
MC
B
CA
MP
P
EN
DL
ET
ON
A
RE
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
UN
CL
AS
SIF
IED
UNCLASSIFIED
EW
MG
6/
/2
3:
:2
PM
G-004
BI
ND
IN
G
IN
DE
X
FI
NA
L
SU
BM
IT
TA
L
BEWPMMP
07/07/2020
18303486 2 393
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
/2
/2
:1
:5
P
M
GI001
IN
D
E X
O F
D R
A W
IN
G
S
F
IN
A L
S U
B M
IT
TA
L
BEWPMMP
07/07/2020
3 393
18303487
FINAL SUBMITTAL - GENERAL INFORMATION - BINDING 01
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
1 G-001 18303485 COVER SHEET X
2 G-004 18303486 BINDING INDEX X
3 GI001 18303487 INDEX OF DRAWINGS X
4 GI002 18303488 INDEX OF DRAWINGS X
5 GI003 18303489 INDEX OF DRAWINGS X
6 GI100 18303490 PROJECT INFORMATION X
7 GI101 18303491 SHEET NAMING SYSTEM DIAGRAM X
FINAL SUBMITTAL - LIFE SAFETY
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
8 GI010 18303492 LIFE SAFETY NOTES AND LEGENDS X
9 GI011 18303493 LIFE SAFETY SITE PLAN X
10 GI012 18303494 LIFE SAFETY PLAN X
FINAL SUBMITTAL - CIVIL
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
11 G-101 18303495 VICINITY/LOCATION MAP X
12 GC101 18303496 CONSTRUCTION PHASING PLAN X
13 V-101 18303497 EXISTING CONDITIONS X
14 CD101 18303498 DEMOLITION PLAN X
15 CS101 18303499 SITE PLAN X
16 CS102 18303500 FIRE ACCESS PLAN X
17 CU101 18303501 UTILITY PLAN X
18 CU102 18303502 UTILITY PLAN X
19 CG101 18303503 GRADING AND DRAINAGE PLAN X
20 CG102 18303504 GRADING AND DRAINAGE PLAN X
21 CG103 18303505 GRADING AND DRAINAGE PLAN X
22 CG104 18303506 GRADING AND DRAINAGE PLAN X
23 CG105 18303507 GRADING AND DRAINAGE PLAN X
24 CG106 18303508 GRADING AND DRAINAGE PLAN X
25 CE001 18303509 EROSION AND SEDIMENT CONTROL NOTES X
26 CE002 18303510 EROSION AND SEDIMENT CONTROL NOTES X
27 CE101 18303511 EROSION AND SEDIMENT CONTROL PLAN X
28 CE501 18303512 EROSION AND SEDIMENT CONTROL DETAILS X
29 CS501 18303513 DETAILS X
30 CS502 18303514 DETAILS X
31 CS503 18303515 DETAILS X
32 CS504 18303516 DETAILS X
33 CS505 18303517 DETAILS X
34 CS506 18303518 DETAILS X
35 CS507 18303519 DETAILS X
36 CS508 18303520 DETAILS X
37 CS509 18303521 DETAILS X
38 CS510 18303522 DETAILS X
39 CS511 18303523 DETAILS X
40 CS512 18303524 DETAILS X
41 CS513 18303525 DETAILS X
42 BL101 18303526 BORING LOCATIONS X
43 LB001 18303527 BORING RECORD LEGEND X
44 LB101 18303528 BORING LOG X
45 LB102 18303529 BORING LOG X
FINAL SUBMITTAL - LANDSCAPE
SHEET
NUMBER
SHEET
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
46 LP101 18303530 PROPOSED LANDSCAPE PLAN X
47 LP601 18303531 MASTER PLANT SCHEDULE & LANDSCAPE DETAILS X
FINAL SUBMITTAL - IRRIGATION
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
48 IP101 18303532 IRRIGATION PLAN X
49 IP102 18303533 IRRIGATION NOTES AND DETAILS X
FINAL SUBMITTAL - STRUCTURAL
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
50 S-001 18303534 GENERAL NOTES X
51 S-002 18303535 GENERAL NOTES X
52 S-003 18303536 GENERAL NOTES X
53 SB101 18303537 FOUNDATION PLAN X
54 SF101 18303538 LOW ROOF FRAMING PLAN X
55 SF102 18303539 HIGH ROOF FRAMING PLAN X
56 SB501 18303540 FOUNDATION DETAILS X
57 SB502 18303541 FOUNDATION DETAILS X
58 SB503 18303542 FOUNDATION DETAILS X
59 S-501 18303543 STEEL DETAILS X
60 S-502 18303544 STEEL DETAILS X
61 S-503 18303545 STEEL DETAILS X
62 S-504 18303546 STEEL DETAILS X
63 S-505 18303547 STEEL DETAILS X
64 S-506 18303548 STEEL DETAILS X
65 S-507 18303549 TYPICAL MASONRY (CMU) DETAILS X
66 S901 18303550 BUILDING ISOMETRICS X
FINAL SUBMITTAL - ARCHITECTURE
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
118 AE201 18303602 EXTERIOR ELEVATIONS X
119 AE202 18303603 EXTERIOR ELEVATIONS X
120 AE300 18303604 AIR BARRIER DIAGRAMS X
121 AE311 18303605 WALL SECTIONS X
122 AE500 18303606 TYPICAL CMU DETAILS X
123 AE501 18303607 TYPICAL CMU DETAILS X
124 AE502 18303608 WALL SECTIONS DETAILS X
125 AE503 18303609 TYPICAL CMU DETAILS X
126 AE505 18303610 TYPICAL METAL ROOFING DETAILS X
127 AE511 18303611 EXTERIOR SECTION DETAILS X
128 QA101 18303612 PARTIAL EQUIPMENT PLAN - SECTOR 01 X
129 QA102 18303613 PARTIAL EQUIPMENT PLAN - SECTOR 02 X
130 QA103 18303614 PARTIAL EQUIPMENT PLAN - SECTOR 03 X
131 QA104 18303615 PARTIAL EQUIPMENT PLAN - SECTOR 04 X
132 QA105 18303616 PARTIAL EQUIPMENT PLAN - SECTOR 05 X
133 QA106 18303617 PARTIAL EQUIPMENT PLAN - SECTOR 06 X
134 QA107 18303618 PARTIAL EQUIPMENT PLAN - SECTOR 07 X
135 QA108 18303619 PARTIAL EQUIPMENT PLAN - SECTOR 08 X
136 QA109 18303620 PARTIAL EQUIPMENT PLAN - SECTOR 09 X
FINAL SUBMITTAL - ARCHITECTURE
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
67 A-001 18303551 ABBREVIATIONS AND SYMBOL LEGEND X
68 AS101 18303552 ARCHITECTURAL SITE PLAN X
69 AS501 18303553 SITE DETAILS X
70 A-101 18303554 BLOCK PLAN AND ROOF PLAN X
71 A-110 18303555 FUNCTIONAL FLOOR PLAN - SECTOR A X
72 A-120 18303556 FUNCTIONAL FLOOR PLAN - SECTOR B X
73 AE101 18303557 PARTIAL FLOOR PLAN - SECTOR 01 X
74 AE102 18303558 PARTIAL FLOOR PLAN - SECTOR 02 X
75 AE103 18303559 PARTIAL FLOOR PLAN - SECTOR 03 X
76 AE104 18303560 PARTIAL FLOOR PLAN - SECTOR 04 X
77 AE105 18303561 PARTIAL FLOOR PLAN - SECTOR 05 X
78 AE106 18303562 PARTIAL FLOOR PLAN - SECTOR 06 X
79 AE107 18303563 PARTIAL FLOOR PLAN - SECTOR 07 X
80 AE108 18303564 PARTIAL FLOOR PLAN - SECTOR 08 X
81 AE109 18303565 PARTIAL FLOOR PLAN - SECTOR 09 X
82 AE111 18303566 PARTIAL REFLECTED CEILING PLAN - SECTOR 01 X
83 AE112 18303567 PARTIAL REFLECTED CEILING PLAN - SECTOR 02 X
84 AE113 18303568 PARTIAL REFLECTED CEILING PLAN - SECTOR 03 X
85 AE114 18303569 PARTIAL REFLECTED CEILING PLAN - SECTOR 04 X
86 AE115 18303570 PARTIAL REFLECTED CEILING PLAN - SECTOR 05 X
87 AE116 18303571 PARTIAL REFLECTED CEILING PLAN - SECTOR 06 X
88 AE117 18303572 PARTIAL REFLECTED CEILING PLAN - SECTOR 07 X
89 AE118 18303573 PARTIAL REFLECTED CEILING PLAN - SECTOR 08 X
90 AE119 18303574 PARTIAL REFLECTED CEILING PLAN - SECTOR 09 X
91 AE121 18303575 WALLS TO DECK - SECTOR A X
92 AE122 18303576 WALLS TO DECK - SECTOR B X
93 AI401 18303577 EQUIPMENT ELEVATIONS X
94 AI402 18303578 EQUIPMENT ELEVATIONS X
95 AI403 18303579 EQUIPMENT ELEVATIONS X
96 AI404 18303580 ENLARGED PHARMACY X
97 AI407 18303581 TOILET/LOCKERS ELEVATIONS X
98 AI501 18303582 INTERIOR PLAN DETAILS X
99 AI503 18303583 EXTERIOR PLAN DETAILS X
100 AI601 18303584 PARTITION TYPES X
101 AI602 18303585 PARTITION TYPES X
102 AI603 18303586 PARTITION TYPES & HEAD DETAILS X
103 AI604 18303587 PARTITION FRAMING DETAILS X
104 AI605 18303588 GYP BD DETAILS X
105 AI606 18303589 LEAD SHELDING X
106 AI609 18303590 CEILING DETAILS X
107 AI611 18303591 METAL FABRICATIONS X
108 AI612 18303592 DOOR,AND SAFETY GLAZING INFORMATION X
109 AI613 18303593 DOOR DETAILS, BORROWED LITES AND LOUVERS INFO X
110 AI614 18303594 DOOR SCHEDULE X
111 AI615 18303595 DOOR SCHEDULE X
112 AI619 18303596 LOG CAT C EQUIPMENT MOUNTING DIAGRAMS X
113 AI620 18303597 TOILET TYPES X
114 AI621 18303598 TOILET TYPES X
115 AI622 18303599 LOG CAT A MOUNTING GUIDE SHEET X
116 AI623 18303600 SHOWER DETAILS X
117 AI625 18303601 AUDIO BOOTH DETAILS X
FINAL SUBMITTAL - INTERIOR DESIGN
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
137 I-101 18303621 OVERALL FINISH PLAN - SECTOR A X
138 I-102 18303622 OVERALL FINISH PLAN - SECTOR B X
139 IN101 18303623 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 01 X
140 IN102 18303624 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 02 X
141 IN103 18303625 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 03 X
142 IN104 18303626 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 04 X
143 IN105 18303627 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 05 X
144 IN106 18303628 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 06 X
145 IN107 18303629 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 07 X
146 IN108 18303630 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 08 X
147 IN109 18303631 PARTIAL FINISH PLAN - LEVEL 01 - SECTOR 09 X
148 I-602 18303632 INTERIOR DESIGN FINISH SCHEDULE X
149 I-701 18303633 INTERIOR DESIGN FINISH SPECIFICATIONS X
150 I-702 18303634 INTERIOR FINISH LAYOUT - ELEVATIONS X
151 I-703 18303635 INTERIOR FINISH ELEVATIONS X
152 I-704 18303636 INTERIOR FINISH DETAILS - ELEVATIONS X
153 I-705 18303637 INTERIOR FINISH DETAILS X
154 I-706 18303638 INTERIOR FINISH DETAILS X
155 I-707 18303639 INTERIOR FINISH DETAILS X
156 I-708 18303640 INTERIOR FINISH DETAILS X
FINAL SUBMITTAL - GRAPHICS
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
157 AG001 18303641 GENERAL SIGNAGE INFORMATION X
158 AG101 18303642 SIGNAGE SITE PLAN X
159 AG501 18303643 EXTERIOR SIGNAGE DETAILS X
160 AG502 18303644 EXTERIOR SIGNAGE DETAILS X
161 AG503 18303645 EXTERIOR SIGNAGE DETAILS X
162 AG504 18303646 INTERIOR SIGNAGE DETAILS X
163 AG505 18303647 INTERIOR SIGNAGE DETAILS X
164 AG506 18303648 INTERIOR SIGNAGE DETAILS X
165 AG507 18303649 INTERIOR SIGNAGE DETAILS X
166 AG508 18303650 INTERIOR SIGNAGE DETAILS X
167 AG509 18303651 INTERIOR SIGNAGE DETAILS X
168 AG510 18303652 INTERIOR SIGNAGE DETAILS X
169 AG1011 18303653 SIGNAGE SIGN LOCATION PLAN X
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
S
A N
D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D L E
T O
N
A R
E A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
UNCLASSIFIED
EW
MG
/2
/2
:5
:3
P
M
GI002
IN
D
E X
O F
D R
A W
IN
G
S
F
IN
A L
S U
B M
IT
TA
L
BEWPMMP
07/07/2020
4 393
18303488
FINAL SUBMITTAL - GENERAL INFORMATION - BINDING 02
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
1 G-001 18303485 COVER SHEET X
2 G-004 18303486 BINDING INDEX X
3 GI001 18303487 INDEX OF DRAWINGS X
4 GI002 18303488 INDEX OF DRAWINGS X
5 GI003 18303489 INDEX OF DRAWINGS X
6 GI100 18303490 PROJECT INFORMATION X
7 GI101 18303491 SHEET NAMING SYSTEM DIAGRAM X
FINAL SUBMITTAL - FIRE ALARM
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
170 FA001 18303654 FIRE ALARM LEGENDS AND ABBREVIATIONS X
171 FA002 18303655 FIRE ALARM SPEAKER ZONING PLAN X
172 FA101 18303656 FIRE ALARM OVERALL PLAN X
173 FA111 18303657 FIRE ALARM PLAN - SECTOR 1 X
174 FA112 18303658 FIRE ALARM PLAN - SECTOR 2 X
175 FA113 18303659 FIRE ALARM PLAN - SECTOR 3 X
176 FA114 18303660 FIRE ALARM PLAN - SECTOR 4 X
177 FA115 18303661 FIRE ALARM PLAN - SECTOR 5 X
178 FA116 18303662 FIRE ALARM PLAN - SECTOR 6 X
179 FA117 18303663 FIRE ALARM PLAN - SECTOR 7 X
180 FA118 18303664 FIRE ALARM PLAN - SECTOR 8 X
181 FA119 18303665 FIRE ALARM PLAN - SECTOR 9 X
182 FA401 18303666 FIRE ALARM SECTIONS X
183 FA701 18303667 FIRE ALARM SEQUENCE OF OPERATIONS X
FINAL SUBMITTAL - FIRE PROTECTION
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
184 FX001 18303668 FIRE PROTECTION GENERAL NOTES X
185 FX002 18303669 FIRE PROTECTION SYMBOL LEGENDS AND ABBREVIATIONS X
186 FX101 18303670 FIRE PROTECTION OVERALL PLAN X
187 FX111 18303671 FIRE PROTECTION PLAN - SECTOR 1 X
188 FX112 18303672 FIRE PROTECTION PLAN - SECTOR 2 X
189 FX113 18303673 FIRE PROTECTION PLAN - SECTOR 3 X
190 FX114 18303674 FIRE PROTECTION PLAN - SECTOR 4 X
191 FX115 18303675 FIRE PROTECTION PLAN - SECTOR 5 X
192 FX116 18303676 FIRE PROTECTION PLAN - SECTOR 6 X
193 FX117 18303677 FIRE PROTECTION PLAN - SECTOR 7 X
194 FX118 18303678 FIRE PROTECTION PLAN - SECTOR 8 X
195 FX119 18303679 FIRE PROTECTION PLAN - SECTOR 9 X
196 FX600 18303680 FIRE PROTECTION DETAILS X
FINAL SUBMITTAL - PLUMBING
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
197 P-001 18303681 PLUMBING NOTES, LEGENDS, ABBREVIATIONS X
198 PB101 18303682 LEVEL 1 - PLUMBING UNDERGROUND OVERALL PLAN X
199 PB111 18303683 PLUMBING UNDERGROUND SECTOR 1 PLAN X
200 PB112 18303684 PLUMBING UNDERGROUND SECTOR 2 PLAN X
201 PB113 18303685 PLUMBING UNDERGROUND SECTOR 3 PLAN X
202 PB114 18303686 PLUMBING UNDERGROUND SECTOR 4 PLAN X
203 PB115 18303687 PLUMBING UNDERGROUND SECTOR 5 PLAN X
204 PB116 18303688 PLUMBING UNDERGROUND SECTOR 6 PLAN X
205 PB117 18303689 PLUMBING UNDERGROUND SECTOR 7 PLAN X
206 PB118 18303690 PLUMBING UNDERGROUND SECTOR 8 PLAN X
207 PB119 18303691 PLUMBING UNDERGROUND SECTOR 9 PLAN X
208 PP101 18303692 LEVEL 1 - PLUMBING OVERALL PLAN X
209 PP111 18303693 PLUMBING SECTOR 1 PLAN X
210 PP112 18303694 PLUMBING SECTOR 2 PLAN X
211 PP113 18303695 PLUMBING SECTOR 3 PLAN X
212 PP114 18303696 PLUMBING SECTOR 4 PLAN X
213 PP115 18303697 PLUMBING SECTOR 5 PLAN X
214 PP116 18303698 PLUMBING SECTOR 6 PLAN X
215 PP117 18303699 PLUMBING SECTOR 7 PLAN X
216 PP118 18303700 PLUMBING SECTOR 8 PLAN X
217 PP119 18303701 PLUMBING SECTOR 9 PLAN X
218 PP120 18303702 PLUMBING ROOF PLAN X
219 P-401 18303703 PLUMBING ENLARGED PLAN X
220 P-402 18303704 PLUMBING ENLARGED PLAN X
221 P-403 18303705 PLUMBING ENLARGED PLAN X
222 P-404 18303706 PLUMBING ENLARGED PLAN X
223 P-405 18303707 PLUMBING ENLARGED PLAN X
224 P-406 18303708 PLUMBING ENLARGED PLAN X
225 P-501 18303709 PLUMBING DETAILS X
226 P-502 18303710 PLUMBING DETAILS X
227 P-503 18303711 PLUMBING DETAILS X
228 P-504 18303712 PLUMBING DETAILS X
229 P-505 18303713 PLUMBING DETAILS X
230 P-506 18303714 PLUMBING DETAILS X
231 P-507 18303715 PLUMBING DETAILS X
232 P-508 18303716 PLUMBING DETAILS X
233 P-601 18303717 PLUMBING SCHEDULES X
234 P-602 18303718 PLUMBING SCHEDULES X
235 P-603 18303719 PLUMBING SCHEDULES X
236 P-604 18303720 PLUMBING SCHEDULES X
237 P-701 18303721 PLUMBING SANITARY PIPING RISER ISOMETRIC X
238 P-702 18303722 PLUMBING DOMESITC WATER PIPING RISER ISOMETRIC X
FINAL SUBMITTAL - MECHANICAL
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
239 M-001 18303723 MECHANICAL LEGEND AND ABBREVIATIONS X
240 M-002 18303724 MECHANICAL LEGEND AND GENERAL NOTES X
241 M-003 18303725 MECHANICAL DESIGN REQUIREMENTS X
242 M-004 18303726 MECHANICAL DESIGN REQUIREMENTS X
243 M-005 18303727 MECHANICAL DESIGN REQUIREMENTS X
244 M-006 18303728 MECHANICAL DESIGN REQUIREMENTS X
245 MS001 18303729 MECHANICAL SITE PLAN X
246 MH101 18303730 MECHANICAL DUCTWORK OVERALL PLAN X
247 MH102 18303731 ROOF - MECHANICAL PLAN X
248 MH111 18303732 MECHANICAL DUCTWORK PLAN SECTOR 1 X
249 MH112 18303733 MECHANICAL DUCTWORK PLAN SECTOR 2 X
250 MH113 18303734 MECHANICAL DUCTWORK PLAN SECTOR 3 X
251 MH114 18303735 MECHANICAL DUCTWORK PLAN SECTOR 4 X
252 MH115 18303736 MECHANICAL DUCTWORK PLAN SECTOR 5 X
253 MH116 18303737 MECHANICAL DUCTWORK PLAN SECTOR 6 X
254 MH117 18303738 MECHANICAL DUCTWORK PLAN SECTOR 7 X
255 MH118 18303739 MECHANICAL DUCTWORK PLAN SECTOR 8 X
256 MH119 18303740 MECHANICAL DUCTWORK PLAN SECTOR 9 X
257 MP101 18303741 MECHANICAL PIPING OVERALL PLAN X
258 MP111 18303742 MECHANICAL PIPING PLAN SECTOR 1 X
259 MP112 18303743 MECHANICAL PIPING PLAN SECTOR 2 X
260 MP113 18303744 MECHANICAL PIPING PLAN SECTOR 3 X
261 MP114 18303745 MECHANICAL PIPING PLAN SECTOR 4 X
262 MP115 18303746 MECHANICAL PIPING PLAN SECTOR 5 X
263 MP116 18303747 MECHANICAL PIPING PLAN SECTOR 6 X
264 MP117 18303748 MECHANICAL PIPING PLAN SECTOR 7 X
265 MP118 18303749 MECHANICAL PIPING PLAN SECTOR 8 X
266 MP119 18303750 MECHANICAL PIPING PLAN SECTOR 9 X
267 M-301 18303751 MECHANICAL ENLARGED CHILLER SITE PLAN X
268 M-401 18303752 MECHANICAL SECTIONS X
269 M-402 18303753 MECHANICAL SECTIONS X
270 M-403 18303754 MECHANICAL SECTIONS X
271 M-501 18303755 MECHANICAL DETAILS X
272 M-502 18303756 MECHANICAL DETAILS X
273 M-503 18303757 MECHANICAL DETAILS X
274 M-504 18303758 MECHANICAL DETAILS X
275 M-505 18303759 MECHANICAL DETAILS X
276 M-601 18303760 MECHANICAL SCHEDULES X
277 M-602 18303761 MECHANICAL SCHEDULES X
278 M-603 18303762 MECHANICAL SCHEDULES X
279 M-604 18303763 MECHANICAL SCHEDULES X
280 M-605 18303764 MECHANICAL SCHEDULES X
281 M-606 18303765 MECHANICAL SCHEDULES X
282 M-607 18303766 MECHANICAL SCHEDULES X
283 M-608 18303767 MECHANICAL SCHEDULES X
284 M-611 18303768 MECHANICAL HYDRONIC RISER DIAGRAM X
285 M-612 18303769 MECHANICAL AIR RISER DIAGRAM X
286 MH701 18303770 MECHANICAL PRESSURE RELATIONSHIPS PLAN SECTOR 1 X
287 MH702 18303771 MECHANICAL PRESSURE RELATIONSHIPS PLAN SECTOR 2 X
288 MI801 18303772 MECHANICAL CONTROL DIAGRAM X
289 MI802 18303773 MECHANICAL CONTROL DIAGRAM X
290 MI803 18303774 MECHANICAL CONTROL DIAGRAM X
291 MI804 18303775 MECHANICAL CONTROL DIAGRAM X
292 MI805 18303776 MECHANICAL CONTROL DIAGRAM X
293 MI806 18303777 MECHANICAL CONTROL DIAGRAM X
294 MI807 18303778 MECHANICAL CONTROL DIAGRAM X
295 MI808 18303779 MECHANICAL CONTROL DIAGRAM X
296 MI809 18303780 MECHANICAL CONTROL DIAGRAM X
297 MI810 18303781 MECHANICAL CONTROL DIAGRAM X
298 MI811 18303782 MECHANICAL CONTROL DIAGRAM X
299 MI812 18303783 MECHANICAL CONTROL DIAGRAM X
300 MI813 18303784 MECHANICAL CONTROL DIAGRAM X
301 MI814 18303785 MECHANICAL CONTROL DIAGRAM X
302 MI815 18303786 MECHANICAL CONTROL DIAGRAM X
303 MI816 18303787 MECHANICAL CONTROL DIAGRAM X
304 MI817 18303788 MECHANICAL CONTROL DIAGRAM X
305 MI818 18303789 MECHANICAL CONTROL DIAGRAM X
306 MI819 18303790 MECHANICAL CONTROL DIAGRAM X
307 MI820 18303791 MECHANICAL CONTROL DIAGRAM X
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
S
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D L E
T O
N
A R
E A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
UNCLASSIFIED
EW
MG
/2
/2
:5
:3
P
M
GI003
IN
D
E X
O F
D R
A W
IN
G
S
F
IN
A L
S U
B M
IT
TA
L
BEWPMMP
07/07/2020
5 393
18303489
FINAL SUBMITTAL - TECHNOLOGY
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
375 T-001 18303859 GENERAL INFORMATION SHEET - TECHNOLOGY X
376 T-100 18303860 TECHNOLOGY SITE PLAN X
377 T-101 18303861 SECURITY SITE PLAN X
378 T-200 18303862 LEVEL 1 - CABLE TRAY PLAN X
379 TI200 18303863 LEVEL 1 NURSE CALL PLAN X
380 TY200 18303864 LEVEL 1 - SECURITY PLAN X
381 TN200 18303865 LEVEL 1 - TECHNOLOGY PLAN X
382 TN401 18303866 COMM ROOM ENLARGED PLANS X
383 TN402 18303867 SERV/COMM ENALARGED PLANS X
384 TY501 18303868 SECURITY CAMERA SCHEDULE X
385 TI501 18303869 NURSE CALL SCHEDULES X
386 T-601 18303870 TECHNOLOGY ONE LINE DIAGRAMS X
387 T-602 18303871 TECHNOLOGY ONE LINE DIAGRAMS X
388 T-603 18303872 TECHNOLOGY GROUNDING ONE LINE X
389 TY601 18303873 SECURITY CAMERA DETAILS X
390 TN601 18303874 DETAILS - TELECOMMUNICATIONS X
391 TN602 18303875 DETAILS - TELECOMMUNICATIONS X
392 TN603 18303876 DETAILS - TELECOMMUNICATIONS X
393 TN604 18303877 DETAILS - TELECOMMUNICATIONS X
FINAL SUBMITTAL - ELECTRICAL
SHEET
NUMBER
DRAWING
NUMBER
NAVFAC
NUMBER SHEET NAME
JULY 07, 2020
- FINAL
SUBMITTAL
308 E-001 18303792 ELECTRICAL LEGEND AND SYMBOL LIST X
309 E-002 18303793 ELECTRICAL LEGEND AND SYMBOL LIST X
310 E-003 18303794 ELECTRICAL GENERAL NOTES X
311 ES101 18303795 ELECTRICAL SITE PLAN X
312 ES102 18303796 ELECTRICAL SITE LIGHTING PLAN X
313 EP101 18303797 PARTIAL POWER PLAN - SECTOR 1 X
314 EP102 18303798 PARTIAL POWER PLAN - SECTOR 2 X
315 EP103 18303799 PARTIAL POWER PLAN - SECTOR 3 X
316 EP104 18303800 PARTIAL POWER PLAN - SECTOR 4 X
317 EP105 18303801 PARTIAL POWER PLAN - SECTOR 5 X
318 EP106 18303802 PARTIAL POWER PLAN - SECTOR 6 X
319 EP107 18303803 PARTIAL POWER PLAN - SECTOR 7 X
320 EP108 18303804 PARTIAL POWER PLAN - SECTOR 8 X
321 EP109 18303805 PARTIAL POWER PLAN - SECTOR 9 X
322 EP201 18303806 PARTIAL EQUIPMENT POWER PLAN - SECTOR 1 X
323 EP202 18303807 PARTIAL EQUIPMENT POWER PLAN - SECTOR 2 X
324 EP203 18303808 PARTIAL EQUIPMENT POWER PLAN - SECTOR 3 X
325 EP204 18303809 PARTIAL EQUIPMENT POWER PLAN - SECTOR 4 X
326 EP205 18303810 PARTIAL EQUIPMENT POWER PLAN - SECTOR 5 X
327 EP206 18303811 PARTIAL EQUIPMENT POWER PLAN - SECTOR 6 X
328 EP207 18303812 PARTIAL EQUIPMENT POWER PLAN - SECTOR 7 X
329 EP208 18303813 PARTIAL EQUIPMENT POWER PLAN - SECTOR 8 X
330 EP209 18303814 PARTIAL EQUIPMENT POWER PLAN - SECTOR 9 X
331 EP401 18303815 ENLARGED ELECTRICAL ROOM POWER PLAN X
332 EP402 18303816 ENLARGED TELECOM ROOM POWER PLAN X
333 EL101 18303817 PARTIAL LIGHTING PLAN - SECTOR 1 X
334 EL102 18303818 PARTIAL LIGHTING PLAN - SECTOR 2 X
335 EL103 18303819 PARTIAL LIGHTING PLAN - SECTOR 3 X
336 EL104 18303820 PARTIAL LIGHTING PLAN - SECTOR 4 X
337 EL105 18303821 PARTIAL LIGHTING PLAN - SECTOR 5 X
338 EL106 18303822 PARTIAL LIGHTING PLAN - SECTOR 6 X
339 EL107 18303823 PARTIAL LIGHTING PLAN - SECTOR 7 X
340 EL108 18303824 PARTIAL LIGHTING PLAN - SECTOR 8 X
341 EL109 18303825 PARTIAL LIGHTING PLAN - SECTOR 9 X
342 E-501 18303826 ELECTRICAL DETAILS X
343 E-502 18303827 ELECTRICAL DETAILS X
344 E-503 18303828 ELECTRICAL DETAILS X
345 E-504 18303829 ELECTRICAL DETAILS X
346 E-505 18303830 ELECTRICAL DETAILS X
347 E-506 18303831 ELECTRICAL DETAILS X
348 E-507 18303832 ELECTRICAL ELEVATION DETAILS X
349 E-511 18303833 ELECTRICAL LIGHTING DETAILS X
350 E-512 18303834 ELECTRICAL LIGHTING DETAILS X
351 E-513 18303835 ELECTRICAL LIGHTING DETAILS X
352 E-514 18303836 ELECTRICAL LIGHTING DETAILS X
353 E-515 18303837 ELECTRICAL LIGHTING DETAILS X
354 E-521 18303838 ELECTRICAL MV DETAILS X
355 E-522 18303839 ELECTRICAL MAINTENANCE HOLE DETAILS X
356 E-523 18303840 ELECTRICAL DUCTBANKS DETAIL X
357 E-524 18303841 ELECTRICAL POLE LIGHT DETAILS X
358 E-525 18303842 ELECTRICAL POLE MOUNTED CAMERA DETAILS X
359 E-601 18303843 ELECTRICAL ONE-LINE DIAGRAM X
360 E-602 18303844 BUILDING GROUNDING RISER DIAGRAM X
361 E-611 18303845 WIRING SCHEDULES X
362 E-621 18303846 EQUIPMENT SCHEDULE X
363 E-622 18303847 EQUIPMENT SCHEDULE X
364 E-623 18303848 EQUIPMENT SCHEDULE X
365 E-631 18303849 LIGHT FIXTURE SCHEDULE X
366 E-632 18303850 LIGHT FIXTURE SCHEDULE X
367 E-633 18303851 LIGHT FIXTURE SCHEDULE X
368 E-634 18303852 LIGHTING CONTROL SCHEDULE X
369 E-635 18303853 LIGHTING CONTROL SCHEDULE X
370 E-641 18303854 PANEL SCHEDULES X
371 E-642 18303855 PANEL SCHEDULES X
372 E-643 18303856 PANEL SCHEDULES X
373 E-644 18303857 PANEL SCHEDULES X
374 E-645 18303858 PANEL SCHEDULES X
MARINE CORPS BASE CAMP PENDLETON, 21 AREA
1. ONE STORY MEDICAL AND DENTAL CLINIC DOES NOT CONTAIN AMBULATORY
HEALTHCARE.
2. BUILDING AREA IS BASED ON FLOOR PLAN TAKE-OFF. BUILDING AREA DOES NOT
INCLUDE SOFFIT.
3. REFER TO GI010 FOR LIFE SAFETY CODE INFORMATION
AMBULATORY CARE CENTER DENTAL CLINIC REPLACEMENT
PROJECT DESCRIPTION
NUMBERING SYSTEM:
P-9906 - A E 1 X X X
JOB NUMBER
DISCIPLINE DESIGNATOR
SHEET TYPE DESIGNATOR
USER DEFINABLE
QUADRANT (PLANS ONLY)
SECTOR (PLANS ONLY)
LEVEL (PLANS ONLY)
SCALE:
EPROJECT NO:
CONSTR. CONTR. NO:
NAVFAC
DRAWING NO:
SHEET OF
A-110
AS NOTED
P-9906
SHEET SCALE
PROJECT NUMBER
SEQUENCE NUMBER
SHEET NUMBER
SHEET NAMING SYSTEM
LOCATION MAP
N
NTS
LEVEL BUILDING GROSS SF
1 24,642
0 = GENERAL ( SYMBOLS LEGEND, NOTES, ETC.)
1 = PLANS (HORIZONTAL VIEWS AND COMBINATION PLAN AND PROFILE)
2 = ELEVATIONS (VERTICAL VIEWS)
3 = SECTIONS (SECTIONAL VIEWS , CROSS SECTIONS, ETC.)
4 = LARGE SCALE VIEWS ( PLANS, ELEVATIONS, OR SECTIONS THAT ARE NOT DETAILS )
5 = DETAILS
6 = SCHEDULES AND DIAGRAMS
7 = USER DEFINED
8 = USER DEFINED
9 = 3D REPRESENTATIONS (ISOMETRICS, PERSPECTIVES, PHOTOGRAPHS)
SHEET TYPE DESIGNATOR:
G - ALL GENERAL
GI GENERAL INFORMATION
GC GENERAL CONTRACT
V - SURVEY/MAPPING
B - GEOTECHNICAL
BB BORING LOGS
CD CIVIL DEMOLITION
CS CIVIL SITE
CG CIVIL GRADING
CU CIVIL UTILITIES
LP LANDSCAPE PLANTING
S - ALL STRUCTURAL
SB STRUCTURAL SUBSTRUCTURE
SF STRUCTURAL FRAMING
A - ALL ARCHITECTURAL
AS ARCHITECTURAL SITE
AE ARCHITECTURAL ELEMENTS
AI ARCHITECTURAL INTERIORS
AG ARCHITECTURAL GRAPHICS
QA LOG CAT A EQUIPMENT PLANS
I - ALL INTERIORS
IN INTERIOR DESIGN
IF INTERIOR FURNISHINGS
FA FIRE PROTECTION DETECTION ALARM
FX FIRE PROTECTION SUPPRESSION
P - ALL PLUMBING
PP PLUMBING PIPING
M - ALL MECHANICAL
MH MECHANICAL HVAC
MI MECHANICAL INSTRUMENTATION
MP MECHANICAL PIPING
MS MECHANICAL SITE
E - ALL ELECTRICAL
ES ELECTRICAL SITE
EL ELECTRICAL INTERIOR LIGHTING
EP ELECTRICAL INTERIOR POWER
T - ALL TELECOMMUNICATIONS
TI INTERCOM
TN DATA NETWORKS
TY SECURITY
DISCIPLINE DESIGNATOR :
PLAN LEVELS:
B UNDER FLOOR ( LEVEL ONE )
1 LEVEL ONE
21 Area Branch Health Clinic
Naval Hospital Camp Pendleton
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
LA
TO
R Y
C A
R E
C E
N
TE
R R
E P
LA
C
E M
E N
T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
W
E S
T
NA
VF
AC
P
AC
IF
IC
H
IG
HW
AY
, S
AN
D
IE
GO
C
A
EE
MC
B
CA
MP
P
EN
DL
ET
ON
A
RE
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
UN
CL
AS
SIF
IED
UNCLASSIFIED
EW
MG
6/
/2
3:
:0
PM
GI100
PR
OJ
EC
T
IN
FO
RM
AT
IO
N
FI
NA
L
SU
BM
IT
TA
L
BEWPMMP
07/07/2020
18303490 6 393
OVERALL
*SECTORS
A B
SECTOR 01
SHEET XX101
SECTOR 02
SHEET XX102
SECTOR 03
SHEET X103
SECTOR 05
SHEET XX105
SECTOR 06
SHEET XX106
SECTOR 07
SHEET XX107
SECTOR 08
SHEET XX108
SECTOR 09
SHEET XX109
SECTOR 04
SHEET XX104
*XX INDICATED SHEET SERIES
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G C
O M
M
AN
D
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
LA
TO
R Y
C A
R E
C E
N
TE
R R
E P
LA
C
E M
E N
T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
C O
M M
A N
D S
O U
TH
W
E S
T
NA
VF
AC
P
AC
IF
IC
H
IG
HW
AY
, S
AN
D
IE
GO
C
A
EE
MC
B
CA
MP
P
EN
DL
ET
ON
A
RE
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
UN
CL
AS
SIF
IED
UNCLASSIFIED
EW
MG
6/
/2
3:
:1
PM
GI101
SH
EE
T
NA
MI
NG
S
YS
TE
M
DI
AG
RA
MS
FI
NA
L
SU
BM
IT
TA
L
BEWPMMP
07/07/2020
PLAN
NORTH
SCALE: 16'8'4'
SHEET NAMING SYSTEM DIAGRAMS
1/16" = 1'-0"
18303491 7 393
S
F S
D
S
A H
U
I
O
CO
AFF ABOVE FINISHED FLOOR
AIM ADDRESSABLE INPUT MODULE
AOM ADDRESSABLE OUTPUT MODULE
BFC BELOW FINISH CEILING
C CONDUIT
CB CIRCUIT BREAKER
EC EMPTY CONDUIT
EOLR END OF LINE RESISTOR
NC (N.C.) NORMALLY CLOSED
NO (N.O.) NORMALLY OPEN
NIC NOT IN CONTRACT
PNL PANEL
PTR PRINTER
SP SPARE
TS TAMPER SWITCH
WF WATERFLOW
UF UNDERFLOOR
UG UNDERGROUND
WG WIRE GUARD
WP WEATHERPROOF
ABBREVIATIONS
FIRE ALARM AND MASS NOTIFICATION
GENERAL NOTES
1. PROVIDE EQUIPMENT, MATERIALS, LABOR, SUPERVISION, AND
SERVICE NECESSARY TO PROVIDE A COMPLETE FUNCTIONING FIRE
ALARM SYSTEM IN A SAFE WORKING ORDER.
2. SYMBOLS FOR VARIOUS ELEMENTS AND SYSTEMS ARE SHOWN ON
THE DRAWINGS. SHOULD THERE BE DOUBT REGARDING THE
MEANING OR INTENT OF THE SYMBOLS USED, AN INTERPRETATION
MUST BE OBTAINED FROM THE CONTRACTING OFFICER IN WRITING.
THE DECISION OF THE CONTRACTING OFFICER IS FINAL.
3. EXAMINE THE CONTRACT DOCUMENTS CAREFULLY BEFORE
SUBMITTING A BID, WITH PARTICULAR ATTENTION TO ERRORS,
OMISSIONS, CONFLICTS WITH PROVISIONS OF LAWS AND CODES
HAVING JURISDICTION, CONFLICTS BETWEEN DRAWINGS AND
SPECIFICATIONS, AND AMBIGUOUS DEFINITION OF THE EXTENT OF
COVERAGE BETWEEN CONTRACTS. ANY SUCH DISCREPANCY MUST
BE BROUGHT IMMEDIATELY TO THE ATTENTION OF THE
CONTRACTING OFFICER FOR CORRECTION. SHOULD ERRORS,
OMISSIONS, CONFLICTS, OR AMBIGUITIES EXIST, THE CONTRACTOR
MUST HAVE THEM EXPLAINED AND ADJUSTED IN WRITING BEFORE
SIGNING THE CONTRACT OR PROCEEDING WITH THE WORK;
OTHERWISE HE SHALL AT HIS OWN EXPENSE SUPPLY THE MATERIALS
AND LABOR TO MAKE GOOD DAMAGE OR DEFECTS IN HIS WORK OR
THE RESULTS OBTAINED FROM SUCH DISCREPANCY.
4. WHEREVER CONFLICTS OCCUR BETWEEN DIFFERENT PARTS OF THE
CONTRACT DOCUMENTS, THE GREATER QUANTITY, THE BETTER
QUALITY, OR LARGER SIZE MUST PREVAIL UNLESS THE CONTRACTING
OFFICER INFORMS THE CONTRACTOR OTHERWISE IN WRITING.
5. THE SCALE OF EACH DRAWING IS RELATIVELY ACCURATE;
DIMENSIONS SHOWN ARE TO CENTERLINE FROM ASSUMED BUILDING
PERIMETER. OBTAIN THE NECESSARY DIMENSIONS FOR TAKEOFFS
FROM THE CONTRACTING OFFICER. NO ADDITIONAL COST TO THE
OWNER WILL BE CONSIDERED FOR FAILURE TO OBTAIN DIMENSIONS
WHERE NOT CLEAR OR IN ERROR ON THE DRAWINGS.
6. DEVICES OR FIXTURES ROUGHED IN IMPROPERLY AND NOT
POSITIONED ON IMPLIED CENTER LINES MUST BE REPOSITIONED AT
NO COST.
7. GUARANTEE WORK AND MATERIALS FREE FROM DEFECTS FOR A
MINIMUM PERIOD OF ONE YEAR UNLESS OTHERWISE NOTED.
8. ASSUME RESPONSIBILITY FOR FILING AND PAYING FEES AND
OBTAINING NECESSARY PERMITS AND CERTIFICATES OF INSPECTION.
DELIVER CERTIFICATES OF INSPECTION TO THE CONTRACTING
OFFICER INCLUDING COPIES WITH MAINTENANCE MANUALS.
9. ONLY EXPERIENCED CRAFTSMEN KNOWLEDGEABLE IN THEIR
RESPECTIVE TRADE MUST PERFORM THE WORK DESCRIBED IN THE
CONSTRUCTION DOCUMENTS.
10. WORK MUST BE DONE IN ACCORDANCE WITH THE LATEST ADOPTED
ADDITION OF NFPA 72. CONFORM TO APPLICABLE LOCAL CODES AND
AMENDMENTS.
11. FIRE ALARM PANELS, DEVICES, CONDUIT, WIRE, BOXES, AND FITTINGS
MUST MEET THE STANDARDS OF NFPA 72 AND MUST BE INSTALLED
AS PART OF A LISTED SYSTEM.
12. SUBMIT SHOP DRAWINGS FOR REVIEW OF EQUIPMENT, DEVICES, AND
MATERIALS. DEVIATIONS FROM ITEMS SPECIFIED MUST BE CLEARLY
IDENTIFIED AND SEPARATELY SUBMITTED WITH A FORMAL
SUBSTITUTION REQUEST. DRAWINGS MUST BE SUBMITTED AND
APPROVED BY THE CONTRACTING OFFICER.
FIRE ALARM AND MASS NOTIFICATION SYMBOLS LEGEND
MNTG. HT. UNODESCRIPTION
FIRE ALARM SPRINKLER FLOW SWITCH
FIRE ALARM SPRINKLER TAMPER SWITCH
FIRE ALARM SPRINKLER PRESSURE SWITCH
SMOKE DETECTOR WALL MOUNTED 9" BFC
SMOKE DETECTOR CEILING MOUNTED --
HIGH/LOW PRESSURE SUPERVISORY
DUCT SMOKE DETECTOR FOR AIR HANDLING UNIT
--FIRE ALARM TERMINAL CABINET
ELECTRO-MAGNETIC DOOR HOLDER
FIRE ALARM BELL 108" AFF
FIRE ALARM CONTROL PANEL
__" AFF
FIRE ALARM ANNUNCIATOR PANEL
__" AFF
LOCAL OPERATING CONSOLE
FIRE ALARM POWER SUPPLY FOUR CIRCUIT FIRE ALARM NOTIFICATION
APPLIANCE POWER EXTENDER
DUCT SMOKE DETECTOR FOR FIRE SMOKE DAMPER
FIRE ALARM PULL STATION WALL MOUNTED 48" AFF
FIRE ALARM AUDIBLE/VISUAL SIGNAL TYPICAL CEILING MOUNT, WM = WALL MOUNT
C = CANDELLA RATING, W = SPEAKER WATTAGE
WALL MOUNT
80" - 96" AFF
FIRE ALARM AUDIBLE SIGNAL TYPICAL CEILING MOUNT, WM = WALL MOUNT
W = SPEAKER WATTAGE
FIRE ALARM VISUAL SIGNAL TYPICAL CEILING MOUNT, WM = WALL MOUNT
C = CANDELLA RATING
WALL MOUNT
80" - 96" AFF
WALL MOUNT
80" - 96" AFF
__" AFF
EMERGENCY VOICE/ALARM COMMUNICATION PANEL
DIGITAL ALARM COMMUNICATOR TRANSMITTER
__" AFF
__" AFF
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE --
SYMBOL
WF
TS
PS
FACP
DH
FAAP
LOC
FAPS
H/L
F
WM
WM
EVAC
WM
C W
C
W
FATC
DACT
CARBON MONOXIDE DETECTOR --
--ET EMERGENCY TEXTUAL VISIBLE APPLIANCE
MASS NOTIFICATION SYSTEM RADIO TRANSCEIVERMNSR --
FIRE ALARM AND MASS NOTIFICATION SYSTEM
1. PROVIDE COMBINED FIRE ALARM AND MASS NOTIFICATION IN AREAS INDICATED ON THE DRAWINGS.
2. AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES ARE SHOWN TO INDICATE WHICH ROOMS/AREAS REQUIRE
COVERAGE. ACTUAL NUMBER OF DEVICES AND RATINGS MUST BE THE CONTRACTOR'S RESPONSIBILITY.
3. SPEAKERS MUST BE PLACED TO MEET INTELLIGIBILITY REQUIREMENTS. ADDITIONAL DEVICES MAY BE NEEDED
THROUGHOUT SPACES DUE TO GEOMETRY AND BUILDING FINISHES.
4. PROVIDE SYNCHRONIZATION OF VISIBLE NOTIFICATION APPLIANCES.
5. VISUAL STROBE DEVICES MUST MEET THE REQUIREMENTS OF ADA, UL, AND NFPA.
6. PROVIDE DUCT SMOKE DETECTORS TO COORDINATE WITH THE MECHANICAL SYSTEM PER REFERENCED CODES
AND STANDARDS, AND THE AUTHORITIES HAVING JURISDICTION. THIS INCLUDES BUT IS NOT LIMITED TO
COORDINATION WITH AIR HANDLING UNITS OVER 2,000 CFM.
7. PROVIDE MODULES, POWER SUPPLIES, HARDWARE, SOFTWARE, ETC. TO THE FIRE ALARM SYSTEM IN ORDER TO ACCOMMODATE THE ADDITIONAL FIRE ALARM DEVICES. PROVIDE SPARE CAPACITY FOR SYSTEMS, CIRCUITS, AND EQUIPMENT.
8. PROVIDE SURGE PROTECTION AT CONTROL PANELS, SUBPANELS, TRANSMITTERS, AMPLIFIERS, AND POWER
SUPPLY PANELS.
9. PROVIDE A COMPLETE SENSITIVITY REPORT FOR SMOKE, DUCT, AND HEAT DETECTORS. REPLACE DETECTORS
THAT DO NOT MEET THE SENSITIVITY VALUES.
10. SUBMIT SIGNED AND SEALED PLANS INDICATING DEVICE LOCATION, TYPE, CABLING, AND BATTERY CALCULATION
TO THE CONTRACTING OFFICER FOR APPROVAL.
11. PROVIDE CONDUIT AND WIRING FOR FIRE ALARM DEVICES. CONNECT AND PROGRAM DEVICES TO FIRE CONTROL PANEL. PROVIDE POWER SUPPLIES INCLUDING EXPANSION MODULES OR SOFTWARE OR HARDWARE ACCESSORIES REQUIRED FOR A COMPLETE AND FUNCTIONAL INSTALLATION. DEVICES MUST MEET ADA
REQUIREMENTS.
12. WIRING MUST BE COPPER AND IN CONDUIT. WIRING MAY BE SOLID COPPER OR STRANDED AS PERMITTED BY NFPA 70. ALL SIGNALING LINE CIRCUITS MUST BE MINIMUM 18 AWG. INITIATING DEVICE AND NOTIFICATION
APPLIANCE CIRCUITS MUST BE MINIMUM 16 AWG. PROVIDE RED WIRING.
13. CONDUIT MUST BE A MINIMUM 3/4-INCH.
14. UPON ACTIVATION OF THE FIRE ALARM SYSTEM, IN ACCORDANCE WITH THE FIRE ALARM SEQUENCE OF
OPERATIONS, THE AHU MUST SHUT DOWN WHEN IN MANUAL OR AUTOMATIC POSITION. THE EXHAUST FAN MUST BE INTERLOCKED WITH THE AHU STARTER. PROVIDE THE FIRE ALARM RELAY WITHIN 3 FEET OF THE STARTER.
15. PROVIDE SEPARATE SPEAKER ZONE WIRING TO ALLOW PUBLIC ADDRESS PAGING BY ZONE AS SHOWN.
16. FIRE ALARM AND MASS NOTIFICATION EVENTS WILL ACTIVATE ALL SPEAKERS.
17. ALL DEVICES MUST BE KEYED ALIKE WITH A CAT 60 KEY.
18. THWN/THHN IS NOT ACCEPTABLE FOR UNDERGROUND WIRING OF FIRE ALARM AND MASS NOTIFICATION CIRCUITS.
PROVIDE TYPE THW OR XHHW IN WET LOCATIONS.
19. THE DACR AT JOINT EMERGENCY COMMUNICATION CENTER IS A RADIONIC/BOSCH D6600. THE RECEIVING STATION
DISPATCH SOFTWARE IS GE MASTERMIND MONITORING SOFTWARE. THE PREFERRED MODE OF FIRE ALARM
SIGNAL TRANSMISSION IS CONTACT ID.
20. INSTALL PHONE LINES IN CONDUIT FROM THE DACT LOCATION TO THE TELEPHONE BACKBOARD LOCATION.
21. FIRE ALARM AND MASS NOTIFICATION SYSTEMS MUST BE COMPATIBLE WITH THE EXISTING WAVES BASE-WIDE
MASS NOTIFICATION SYSTEM MANUFACTURED BY MADAHCOM/COOPER INDUSTRIES.
22. PROVIDE ALL REQUIRED LABOR, PROGRAMMING AND MATERIALS, EXCEPT FOR THE GOVERNMENT PROVIDED AND
INSTALLED TRANSCEIVER, TO INTEGRATE THE NEWLY INSTALLED FIRE ALARM AND MASS NOTIFICATION SYSTEM WITH THE BASE-WIDE MASS NOTIFICATION SYSTEM. THIS INCLUDES PROGRAMMING PRIORITIES APPROVED BY THE
GOVERNMENT.
23. PROVIDE A SUPERVISORY SIGNAL IF THE MNS IS USED TO OVERRIDE FIRE ALARM AUDIBLE MESSAGES AND VISIBLE SIGNALS DURING SIMULTANEOUS FIRE AND TERRORIST EVENTS. THE SUPERVISORY SIGNAL MUST BE ANNUNCIATED AT THE FACP AND ANY REMOTE FIRE ALARM ANNUNCIATORS AND BE TRANSMITTED TO THE FIRE DEPARTMENT. THE VISUAL ANNUNCIATION OF THE SEPARATE SUPERVISORY SIGNAL MUST BE DISTINCTLY
LABELED OR OTHERWISE CLEARLY IDENTIFIED.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:4
P
M
FA001
18303654
F
IR
E A
LA
R
M L
E G
E N
D S
A N
D A
B B
R E
V
IA
T
IO
N S
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
F
G
H
I
J
B
D
E
SPEAKER ZONE 1
SPEAKER ZONE 3
SPEAKER ZONE 4
THESE SPEAKER ZONES
ARE THE PUBLIC
ADDRESS SPEAKER
ZONES. THERE IS ONLY
ONE FIRE ALARM ZONE
SUCH THAT ALL FIRE
ALARM SIGNALS WILL
ACTIVATE ALL THREE
ZONES.
GEN EXAM
PCMH TEAM
RM
TRMT
NUR MGR OFF
GEN EXAM
GEN EXAM
EXAM/ TELE.
HEALTH
IDC SHRD OFF
MD SHARED
MCMH TEAM
RM
1121 COPY
1121A
MEF OFF
1119 SEL OFF
OIC OFF
PHARM
S TLT
JC
B. HEALTH
OFF
WC ALCOVE
EQ STOR
P TLT
ISO/ EXAM
ISO TLT
GEN EXAM
1128 GEN EXAM
GEN EXAM
GEN EXAM
PROVDR
GEN EXAM
P TLT
ALCOVE
STOR
CLEAN
SOIL
HEARING
SPEC TLT
COMM
GEN EXAM
PAT REC
P TLT
HT/WT
ALCOVE
IMMUN/
PHARM WAIT
1102D
PHARM
WAIT
1102B
PT
WAITING
1102A
KIOSK
1102C
PUB WAIT
1102E
PUB WAIT
1102G
HEARING WAIT
1102H
TLT/SHWR
CONF
M CHNG
F CHNG
TLT/SHWR
DENTAL MECH
1223A
C LINEN
JC
S LINEN
STAFF
LOUNGE
DIR OFF
SEL OFF
DENTAL READI
DENTAL HYG
SHARED PROV
OFF
DENTAL HYG
GEN DTR
GEN DTR
GEN DTR
GEN DTR
GEN DTR
GEN DTR
TRMT EXER
PRIV TRMT
SHARED OFF
S UTIL
1203P TLT
LINEN
1201F
ICE
1201E
TRMT
SUPP
1201D
LAB SHIP/REC
TECH W/S
1201A
EQ STOR
1201C
M TLT
EQ STOR
GAS STOR
CHEM STOR
INST DECON
INST STERIL
DENTAL SUPP
LAB STOR
SERV/ COMM
F TLT
LACT
DENTAL REC
S TLT
DENTAL X-RAY
INST STOR
P TLT
TRMT
OBS/HYD
DENTAL HYG
VENI
MULTI-STAT
SAT LAB
IMMUN
MED RECEPT
S TLT
JC
RECYCLE
ELEC
MEP
MEP
MAIN ELEC
RISER
SPEAKER ZONE 2
SPEAKER ZONE 5
SPEAKER ZONE LEGEND
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:4
P
M
FA002
18303655
F
IR
E A
LA
R
M S
P E
A K
E R
Z O
N
IN
G P
LA
N
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
16'8'4'
FIRE ALARM SPEAKER ZONING PLAN
1/8" = 1'-0"
A P
FACPFAPS
F F
WMWM WMWM
WMWM
W M
W M
F
F
F
LO
C
I
F A
P S
I
T S
T S
W F
I
I
F
WMWM
W M
W M
I
I
WM
WMWM
WM
WM
WM
W M
W M
W M
W M
W M
WMWM
WMWM
WMWM
W M
W M
WM
WMWM
WMWM
W M
WMWM
WMWM
WMWM
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
F
W M
W M
W M
W M
W M
W M
WMWM
T S
W M
W M
T S
W M
W M
W M
W M
W M
W M
S
A H
U O
CO
O
O
O
WMWM
W F
WMWM
W M
W M
WMWM
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
S
A H
U
I
WMWM
F
G
H
I
J
B
D
E
DACT
ANTENNA
REFER TO SECTOR
PLANS FOR FURTHER
INFORMATION.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:5
P
M
FA101
18303656
F
IR
E A
LA
R
M O
V E
R A
LL
P
LA
N
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
16'8'4'
FIRE ALARM OVERALL PLAN
A
P S
I
T S
T S
W F
I
I
F
I
I
WM
W M
W M
WM
T S
W F
WMWM
I
J
GEN EXAM
EXRG1
PCMH TEAM
RM
WRCH1
RISER
TRMT
TRGM1
NUR MGR OFF
OFA04
GEN EXAM
EXRG1
PROVDR
OFA04
GEN EXAM
EXRG1
P TLT
TLTU1
ALCOVE
ICE01
CORR
ZCORR
11C7
STOR
SRS01
CLEAN
UCCL1
SOIL
USCL1
TRMT
TRGM1
JC
JANC1
15C .5W
15C .25W
15C .25W
.25W
15C .5W
15C .5W
30C .5W
15C .25W
15C .25W
15C .5W
15C .25W 15C .25W
15C .25W
15C .25W
15C
1W
RECYCLE
UTR01
DACT
15C .5W
.5W
ANTENNA
OBS/HYD
OOHR1
REF. FA112
REF. FA112
R E
F
F A
R E
F
F A
C
.2 5W
15C
WPMNSR
2 3
SAT LAB
LBSP1
STOR
SRS01
AUDIO
BOOTH
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:5
P
M
FA111
18303657
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
8'4'2'
FIRE ALARM PLAN - SECTOR 1
1/4" = 1'-0"
1 PROVIDE 18-INCH X 16-INCH X 10-INCH NEMA 4X
ENCLOSURE, WITHIN 15 FEET OF THE FIRE
ALARM/MNS PANEL FOR THE GOVERNMENT
PROVIDED AND INSTALLED MNS TRANSCEIVER
PANEL (COOPER NOTIFICATION TRX-401).
2 PROVIDE A MINIMUM 1.5-INCH CONDUIT WITH LMR
400 CABLE FROM THE TRANSCEIVER ENCLOSURE
TO A POINT LOCATED 4 FEET ABOVE THE ROOF,
WITH A ROOF MOUNTED WEATHER-HEAD FOR THE
FUTURE ANTENNA INSTALLATION. COIL A
MINIMUM LENGTH OF 6 FEET OF LMR 400 CABLE
AT EACH END FOR THE FUTURE ANTENNA
INSTALLATION. THE MAXIMUM DISTANCE FROM
THE TRANSCEIVER ENCLOSURE TO THE
WEATHER-HEAD MUST BE WITHIN 200 FEET USING
LMR 400 CABLE. LONGER CABLE RUNS REQUIRE
UPGRADE TO LMR 600 TYPE CABLE.
3 PROGRAM THE AUDIO INPUT AND NORMALLY
OPEN RELAY CONNECTIONS AS A SECOND
MICROPHONE WITH ON WAY INPUT AND PROVIDE
ALL COMPONENTS IN THE FACP/MNS VOICE
PANEL FOR THE FUTURE TRANSCEIVER
CONNECTION.
4 PROVIDE CONDUITS FROM THE FIRE ALARM/MNS
PANEL TO THE TRANSCEIVER ENCLOSURE FOR
FUTURE PANEL INTERCONNECTIONS. PROVIDE A
SEPARATE JUNCTION BOX CONTAINING A
TERMINAL STRIP, WITH A MINIMUM OF FOUR
CONTACTS, FOR THE FUTURE MNS TRANSCEIVER
CONNECTIONS.
SHEET NOTES
P S
I
WMWM
T S
W M
W M
8 7 6
H
GEN EXAM
EXRG1
GEN EXAM
EXRG1
EXAM/ TELE.
HEALTH
EXTH1
GEN EXAM
EXRG1
GEN EXAM
EXRG1
GEN EXAM
EXRG1
GEN EXAM
EXRG1
CORR
ZCORR
11C6
PROVDR
OFA04
GEN EXAM
EXRG1
GEN EXAM
EXRG1
HT/WT
ALCOVE
EXR11
15C .25W
15C .25W
15C .25W
15C .5W
15C .25W
15C .25W
15C .25W
15C .25W
15C .25W
15C .25W
15C .5W
.5W
15C .5W
R E
F
F A
R E
F
F A
REF. FA111
REF. FA111
REF. FA113
REF. FA113
15C .25W
C
.2 5W
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:5
P
M
FA112
18303658
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
8'4'2'
FIRE ALARM PLAN - SECTOR 2
1/4" = 1'-0"
W M
W M
W M
W M
WMWM
WMWM
WMWM
8 7 6
F
G
IDC SHRD OFF
WRCH1
MD SHARED
OFA03
MCMH TEAM
RM
WRCH1
1121 COPY
RPR01
1121A
MEF OFF
OFA04
1119 SEL OFF
OFA04
JC
JANC1
EQ STOR
SRE01
P TLT
TLTU1
ISO/ EXAM
EXRG6
ISO TLT
TLTU1
COPY
RPR01
1121A
15C .25W
15C .25W
15C .25W
.25W
.25W
15C .5W
15C .5W
30C .25W
30C .25W
15C .5W
15C .5W
30C .25W
.5W
S TLT
TLTU1
R E
F
F A
R E
F
F A
REF. FA112
REF. FA112
C
.2 5W
C
.2 5W
15C .25W
15C .25W
15C .25W
.25W
.25W
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:0
P
M
FA113
18303659
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
8'4'2'
FIRE ALARM PLAN - SECTOR 3
WMWM
A
P S
I
WMWM
WMWM
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
T S
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
WMWM
I
J
D
E
ELEC
MEP
HEARING
PEHS2
SPEC TLT
TLTU1
COMM
COMC1
PUB WAIT
LOB04
1102G
HEARING WAIT
WRC01
1102H
TLT/SHWR
TLTM2
CONF
CRA01
M CHNG
LR002
F CHNG
LR002
TLT/SHWR
TLTF2
ELEC.
CORR
ZCORR
12C2
C LINEN
LCCL4
JC
JANC1
S LINEN
LCSL2
STAFF
LOUNGE
SL001
15C .25W
15C .25W
15C .25W
15C .5W
110C .5W
15C .25W
15C .25W
15C .5W
15C .5W
15C .25W
15C .25W
15C .25W
15C
15C
R E
F
F A
R E
F
F A
REF. FA115
REF. FA115
R E
F
F A
R E
F
F A
15C .25W
C
.2 5W
C
.2 5W
C
.2 5W
C
.2 5W
C
.2 5W
C
.2 5W
0C
.5 W
0C
.5 W
0C
.5 W
0C
.5 W
0C
.5 W
15C .25W
SAT LAB
LBSP1
STOR
SRS01
AUDIO
BOOTH
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:0
P
M
FA114
18303660
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
8'4'2'
FIRE ALARM PLAN - SECTOR 4
FAPS
A
P S
I
W M
W M
WMWM
WMWM
T S
W M
W M
O
O
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
W M
6 5
H
WC ALCOVE
SRLW1
CORR
ZCORR
11C1
VENI
MULTI-STAT
LBVP2
COMM
COMC1
GEN EXAM
EXRG1
PAT REC
FILE1
P TLT
TLTU1
HT/WT
ALCOVE
EXR11
PUB WAIT
LOB04
1102E
ELEC.
SERV/ COMM
COMC2
LACT
LAC01
DENTAL REC
MRS01
DENTAL REC
RECP1
1209A
15C .25W
15C .5W
15C .5W
15C .25W 15C .25W
15C .25W
30C .25W
15C .5W
15C .5W
15C .25W
15C .25W
15C .25W
0C
.5 W
MED RECEPT
RECP1
REF. FA116
REF. FA116
R E
F
F A
R E
F
F A
REF. FA114
REF. FA114
R E
F
F A
R E
F
F A
15C .25W
15C .25W
C
.2 5W
C
.2 5W
.25W
A1
FA401
0C
.5 W
0C
.5 W
0C
.5 W
0C
.5 W
0C
.5 W
WALL MOUNTED
SHUTTER
RELEASE DEVICE
REF: FA401 A3
(5)
SAT LAB
LBSP1
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:1
P
M
FA115
18303661
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B M
IT
TA
L
RSHSLSL
07/07/2020
PLAN
NORTH
SCALE:
8'4'2'
FIRE ALARM PLAN - SECTOR 5
1/4" = 1'-0"
1 PROVIDE LIVE MICROPHONE FOR MAKING
MANUAL PAGES THROUGH MASS
NOTIFICATION SPEAKERS PER UFC 4-021-01,
4-4.2.
A P
WMWM WMWM
F
LO
C
W M
W M
WM
W M
W M
W M
W M
W M
O
W M
W M
6 5
F
G
B
SEL OFF
OFA04
OIC OFF
OFA04
PHARM
PHOD1
S TLT
TLTU1
JC
JANC1
B. HEALTH
OFF
OFDC1
IMMUN/
PHARM WAIT
LOB04
1102D
PHARM
WAIT
LOB04
1102B
PT
WAITING
LOB04
1102A
KIOSK
CLSC1
1102C
PHARM
PHOD1
.25W
15C .5W
15C .5W
15C .25W
15C .5W
15C .5W
15C .5W
15C .5W 15C .5W
0C
.5 W
.5W
1W
IMMUN
OPIR1
R E
F
F A
R E
F
F A
R E
F
F A
REF. FA115
REF. FA115
C
.2 5W
C
0C
.5 W
WP
.25W
.25W
0C
.5 W
A5
FA401
0C
.5 W
A3
FA401
WALL
MOUNTED
SHUTTER
RELEASE
DEVICE
GENERAL NOTES
PROVIDE APPROPRIATE NUMBER OF OUTPUT
MODULES TO INTERFACE WITH LIGHT
CONTROLLERS FOR FIRE ALARM OVERRIDE.
SEE DETAIL B1 ON SHEET E-516.
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E
INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR.
NO.
SHEET
NAVFAC DRAWING
NO.
DES DRW CHK
OF
EPROJECT
NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
A M
B U
L A
T O
R Y
C A
R E
C E
N T
E R
R E
P L A
C E
M E
N T
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G C
O M
M A
N D
S O
U T
H W
E S
T N
A V
F A
C
P
A C
IF
IC
H
IG
H W
A Y
, S A
N D
IE
G
O C
A
EE
M C
B C
A M
P P
E N
D
LE
T O
N
A
R E
A
SV/AE
AS NOTED
P-9906
KEY PLAN
HKS WSP JV
350 N SAINT PAUL ST
SUITE 100
DALLAS, TX 75201-4200
UNCLASSIFIED
U N
C
LA
SS
IF
IE
D
UNCLASSIFIED
EW
MG
-0 -2
:2
:1
P
M
FA116
18303662
F
IR
E A
LA
R
M P
LA
N
S
E C
T O
R
F
IN
A L
S U
B…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .