BT STEAM STERLIZER PRICE TEMPLATE.xlsx
XLSX spreadsheet 14 KB Posted
- Attached to
- 6530--BT Steam Sterilizers Federal contract opportunity
- Solicitation number
- 36C24525Q0643
About this file
This is a detailed pricing template for BT Steam Sterilizers for the Department of Veterans Affairs (VA) at the Baltimore VA Medical Center. The template lists 21 line items covering sterilizer systems, components, and installation services, including MST-V 6-0-6 VS1 sterilizers, pull-out shelves, foot switches, electric steam generators, power supply buffers, equipment finish kits, installation kits, water sample testing, and various installation-related services. The solicitation (36C24525Q0643) requires delivery, transport, deinstallation, and installation of new sterilizer systems with comprehensive requirements for shipping, pre-site readiness, removal of existing equipment, phased installation, and full operational validation within one year of contract award. The procurement is categorized under NAICS code 339112 and involves up to 4 sterilizer systems with all necessary accessories, tools, parts, and qualified installation personnel.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| BUy American Cert .docx | DOCX document | |
| 36C24525Q0643_1.docx | DOCX document | |
| Trade Agreement Cert.docx | DOCX document | |
| 36C24525Q0643.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| ITEM NUMBER | DESCRIPTION | Place of manufacter | QUANTITY | UNIT OF MEASURE | manufacturer name | Price | TOTAL |
| 0001 | MST-V 6-0-6 VS1 Includes single powered vertical sliding door, liquid-ring vacuum pump, pneumatic steam valves, encased mineral wool insulation, and LED status indicator. Constructed with 100% stainless steel chamber, jacket, and piping; clean steam compatible.V-09.02. make and model size/specification sheet capatiable | 3 | EA | $ - 0 | |||
| 0002 | MST-V 6-6-6 2 pull-out shelves 50% MST V 606 US.V-09.02 compatiable | 4 | EA | $ - 0 | |||
| 0003 | Foot switch MST-V must have hands free opening of the sterilizer door.V-09.02. compatiable | 4 | EA | $ - 0 | |||
| 0004 | Electric Steam Generator (30 kW) for generating clean steam according to meet ANSI/AAMI ST8. | 4 | EA | $ - 0 | |||
| 0005 | For WTD units or compatiable. | 4 | EA | $ - 0 | |||
| 0006 | Includes single powered vertical sliding door, liquid-ring vacuum pump, pneumatic steam valves, encased mineral wool insulation, and LED status indicator. Constructed with 100% stainless steel chamber, jacket, and piping; clean steam compatible.V-09.02. | 1 | EA | $ - 0 | |||
| 0007 | Power Supply Buffer, MST V with tube and shell heat exchanger Provides about 35 seconds of 24 VDC backup power to. | 4 | KT | $ - 0 | |||
| 0008 | Equipment finish kit for MST-V 6 Series sterilizers; (3) single door sterilizers w/ integrated steam generators installed side by side and recessed in a wall. Kit includes stainless access panel for service and trim to finish wall opening. | 1 | EA | $ - 0 | |||
| 0009 | Equipment finish kit for MST-V 606 sterilizers; (1) single door sterilizer w/ integrated steam generator installed standalone. Kit includes stainless steel side panels, enclosure panels from top of sterilizer to the ceiling, and access panels for service. | 1 | EA | $ - 0 | |||
| 0010 | Installation kit for MST-V 6 Series sterilizer w/ integrated electric boiler. flex hoses for utility connections, 6 rolls of printer paper, and hardware for installation. | 4 | EA | $ - 0 | |||
| 0011 | Water Sample Kit-3 Containers. | 1 | EA | $ - 0 | |||
| 0012 | This includes water sample collection and testing of 3 water types: hot water, cold water, and critical water. Facility water test meet equipment requirements prior to installation. NOT designed to test to ST-108 requirements. | 1 | EA | $ - 0 | |||
| 0013 | Installation/Equipment Assembly 600 Series Vertical Sterilizer SD (INS-MST6VS1) | 4 | EA | $ - 0 | |||
| 0014 | Installation/Equipment Assembly Power Supply Buffer (INS-PSB | 4 | EA | $ - 0 | |||
| 0015 | Weekend/After Hours Installation Installations outside normal working hours are offered at 36% premium above the negotiated installation pricing (INS-EXT Hours) | 1 | HR | $ - 0 | |||
| 0016 | B-US INS-FORKLIFT-FEE | 1 | EA | $ - 0 | |||
| 0017 | B-US RMV-INT-DIS. | 1 | EA | $ - 0 | |||
| 0018 | Equipment removal to nearest loading dock Vertical Sterilizer (RMV-STV) for VA property manager disposal . | 4 | EA | $ - 0 | |||
| 0019 | B-US INS- DISTANCE-MULTI -FLOOR-FEE. | 4 | EA | $ - 0 | |||
| 0020 | phased Installation Each Additional Mobilization (INS-STAGED) | 5 | EA | $ - 0 | |||
| 0021 | B-US INS-Extended Installation. | 1 | HR | $ - 0 |
File details come from the government source that posted it. Updated .