BCT - BP4 Roofing - Architectural Drawings.pdf

PDF 25 MB Posted

Attached to
Buffalo Central Terminal - Bid Package #4 (Roofing) State and local contract opportunity
Solicitation number
2119822
Issued by
Erie County, New York

About this file

These are architectural roofing drawings for the Buffalo Central Terminal Restoration Project, developed by Quinn Evans Architects and a team of consulting engineers for the Buffalo Central Terminal Central Terminal Restoration Corp. The project is Phase 2, Bid Package 4, focusing on roof restoration for a historically significant building listed on the National Register of Historic Places. The drawings cover multiple roof types and levels, including L1, L2, and L5 office areas, concourse, penthouse, and tower roofs, with detailed demolition and replacement plans. The scope involves removing existing roofing materials, salvaging specific architectural elements like precast concrete tiles, and installing new roofing assemblies using PVC, SBS, and metal roofing systems.

The project emphasizes preservation and historical integrity, requiring all work to meet the Secretary of the Interior's Standards for Historic Properties. The restoration includes careful removal of existing roofing materials, replacement of roof drains and hatches, and detailed membrane installation with specific attention to water drainage, insulation, and flashing. Multiple roof types (Type 1-4) are specified with variations in membrane, insulation, and drainage systems. The project acknowledges potential hazardous materials and requires contractors to verify existing conditions, protect historic elements, and coordinate closely with the architectural team. Structural repairs and masonry work are noted to be part of future bid packages (BP5), indicating this is part of a phased restoration approach for the Buffalo Central Terminal.

View the file

Other files for this state and local contract opportunity

Other files attached to Buffalo Central Terminal - Bid Package #4 (Roofing), newest first.
File Type Posted
Bid Package #4 Roofing Addendum #1.pdf PDF
BCT - BP4 Roofing - Project Specification Manual.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLAN NORTH

DRAWING INDEX

DRAWN BY:PROJECT MANAGER:

QUINNEVANS.COM

4219 WOODWARD AVE

SUITE 301

DETROIT, MI 48201

v 313.462.2550

VICINITY MAPS

QUINN EVANS

4219 WOODWARD AVE

SUITE 301

DETROIT, MI 48201

v 313.462.2550

PROJECT TEAM

02/07/2025

ARCHITECT

PHASE 2 - BID PACKAGE 4

JABLONSKI BUILDING CONSERVATION, INC.

40 WEST 27TH STREET, FLOOR 12

NEW YORK, NY 10001

T: (212) 532-7775

CONSERVATION:

BURO HAPPOLD CONSULTING

ENGINEERS P.C.

100 BROADWAY

NEW YORK, NY 10006

T: (212) 334-2025

MECH/ELEC/PLUMB ENGINEER:

TREDO ENGINEERS

755 SENECA STREET, STE 202

BUFFALO, NY 14210

CIVIL:

GHD

26850 HAGGERTY RD

FARMINGTON HILLS, MI 48331

T: (248) 893-3400

LIFE SAFETY & FIRE PROTECTION:

BARBARA A. CAMPAGNA/ARCHITECTURE

+PLANNING, PLLC

2495 MAIN STREET, STE 402

BUFFALO, NY 14210

LOCAL PRESERVATION ARCHITECT:

TYLIN

1053 31ST STREET NW

WASHINGTON, DC 20007

T: (202) 333-6230

STRUCTURAL ENGINEER:

G001.4

COVER

AWAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL TERMINAL

CENTRAL TERMINAL RESTORATION CORP.

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

BID PACKAGE 4: ROOF PACKAGE

NUMBER SHEET NAME

G001.4 COVER

G004.4 REFERENCE PLANS

G005.4 ROOF TYPES

AD106NE.4 L1 OFFICES NE DEMO PLAN

AD106NW.4 L1 OFFICES NW DEMO PLAN

AD107SW.4 L2 OFFICES SW DEMO PLAN

AD110NE.4 L5 OFFICES NE & CONCOURSE ROOF DEMO PLAN

AD110NW.4 L5 OFFICES NW & CONCOURSE ROOF DEMO PLAN

AD110SE.4 L5 OFFICES SE & CONCOURSE ROOF DEMO PLAN

AD110SW.4 L5 OFFICES SW & CONCOURSE ROOF DEMO PLAN

AD116.4 PENTHOUSE & TOWER ROOF DEMO PLANS

A106NE.4 L1 OFFICES NE ROOF PLAN

A106NW.4 L1 OFFICES NW ROOF PLAN

A107SW.4 L2 OFFICES & SW ROOF PLAN

A110NE.4 L5 OFFICES NE & CONCOURSE ROOF PLAN

A110NW.4 L5 OFFICES NW & CONCOURSE ROOF PLAN

A110SE.4 L5 OFFICES SE & CONCOURSE ROOF PLAN

A110SW.4 L5 OFFICES SW & CONCOURSE ROOF PLAN

A116.4 PENTHOUSE & TOWER ROOF PLANS

A560.4 ROOF DETAILS - LIGHTCOURT ROOF C1

A561.4 ROOF DETAILS - CONCOURSE ROOF A

A562.4 ROOF DETAILS - B2-B9 ROOFS

A563.4 ROOF DETAILS - ROOF B1 & H

A564.4 ROOF DETAILS - CANOPIES

No. Date Description

K

M

ROOF B1

10 12 13

J

N

K

M

ROOFS B2-B9

1 2 3 4 5 6 7 8 9 10 12 13 14

A

B

C

D

E

F

G

H

J

N

P

K

M

L

ROOF C:

NOT IN SCOPE

ROOF A

(L5 OFFICE)

ROOF H

(L2 OFFICE)

ROOF G:

NOT IN SCOPE

ROOF F:

NOT IN SCOPE

ROOF D:

NOT IN SCOPE

ROOF E:

NOT IN SCOPE

ROOF C1

(L1 OFFICE)

CANOPY

NW 1

(L1 OFFICE)

CANOPY

NW 2

(L1

OFFICE)

CANOPY

NE 2:

NOT IN

SCOPE

CANOPY

NE 1

(L1 OFFICE)

ROOF L1-NW

(L1 OFFICE)

NE NW

SE SW

INTERIOR SPACE

NOT IN SCOPE

ROOF A

(L5 OFFICE)

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF

NATIONAL HISTORICAL SIGNIFICANCE AND IS

LISTED ON THE REGISTER OF HISTORIC

PLACES. TREAT THE BUILDING RESPECTFULLY.

TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER OR

DISFIGURE ANY EXISTING MATERIALS,

ELEMENTS OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS

PROJECT MUST MEET THE SECRETARY OF THE

INTERIOR’S STANDARDS FOR THE TREATMENT

OF HISTORIC PROPERTIES WITH GUIDELINES

FOR PRESERVING, REHABILITATING,

RESTORING, AND RECONSTRUCTING HISTORIC

BUILDINGS.

3. ALTHOUGH INTENDED TO CONVEY

APPROPRIATE INFORMATION, ALL DRAWINGS

ARE BASED ON LIMITED FIELD INVESTIGATION

AND ARCHIVAL BUILDING INFORMATION. AS

SUCH, DRAWINGS MAY CONTAIN

DISCREPANCIES DUE TO CONCEALED

CONDITIONS, INACCURACIES IN ORIGINAL

DRAWINGS INACCESSIBLE LOCATIONS,

UNRECORDED BUILDING ALTERATIONS, AND

OTHER CONFLICTING INFORMATION.

CONTRACTOR SHALL VERIFY EXISTING

CONDITIONS AND MEASUREMENT. NOTIFY THE

ARCHITECT REGARDING ANY DISCREPANCY

BETWEEN EXISTING CONDITIONS AND THE

CONTRACT DOCUMENTS PRIOR TO

COMMENCING WORK. FAILURE TO NOTIFY THE

ARCHITECT WILL NOT RELIEVE THE

CONTRACTOR OF THE RESPONSIBILITY TO

PERFORM THE WORK AS INTENDED INTHE

CONTRACT DOCUMENTS.

4. WHERE HAZARDOUS MATERIALS ARE PRESENT

IN CONSTRUCTION AREAS AFFECTED BY

REMOVAL AND DISMANTLING WORK, NOTIFY

OWNER AND REFER TO ENVIRONMENTAL

REPORTS PROVIDED BY OWNER FOR

ADDITIONAL INFORMATION PRIOR TO

DISTURBING OR REMOVAL.

5. REFER TO STRUCTURAL DRAWINGS FOR

ADDITIONAL WORK.

6. COORDINATE ALL DEMOLITION WORK WITH

CUTTING AND PATCHING REQUIRED BY NEW

WORK.

7. PROVIDE ADEQUATE PROTECTION TO ALL

AREAS AFFECTED BY THE WORK. THE

CONTACTOR SHALL BE HELD RESPONSIBLE

FOR ANY DAMAGE TO ANY BUILDING

COMPONENTS WHICH OCCUR AS A RESULT OF

ALL PHASES OF WORK.

GENERAL NOTES

LEGEND

ROOF NOT IN SCOPE

ROOF WORK AREA

AREA OF TEMP ROOFING

REPAIR (ALTERNATE)

TOWER ROOF (B1)

PENTHOUSE

BALCONIES (B2-B9)

ROOF A

ROOF L1-NW

ROOF C1

CANOPY NW-2

CANOPY NW-1CANOPY NE-1

TOWER ROOF (B1)

PENTHOUSE

BALCONIES (B2-B9)

ROOF A

ROOF L1-NW

CANOPY NW-2

CANOPY NW-1

ROOF H

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:0

A M

G004.4

REFERENCE PLANS

AWAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/16" = 1'-0"G004.4

3 TOWER ROOF (ROOF B1)

1/16" = 1'-0"G004.4

2 PENTHOUSE BALCONIES (ROOFS B2-B9)

1/16" = 1'-0"G004.4

1 OVERALL PLAN - LOWER ROOFS

1/64" = 1'-0"G004.4

5 ROOF DIAGRAM - VIEW FROM NORTH

1/64" = 1'-0"G004.4

4 ROOF DIAGRAM - VIEW FROM WEST

No. Date Description

MarcusDeLeys Cloud

MarcusDeLeys Callout N.I.C

MarcusDeLeys Rectangle

MarcusDeLeys Line

MarcusDeLeys Line

MarcusDeLeys Text Box N.I.C

MarcusDeLeys Rectangle

FULLY ADHERED ROOF

MEMBRANE (PVC)

INSULATED COVER BOARD

REPLACEMENT DECK, NOT

IN SCOPE (REFER TO BP5

FOR STRUCTURAL

REPAIRS)

RIGID INSULATION,

TAPERED

ROOF TYPE 4B (PVC ROOFING ASSEMBLY)

SBS ROOFING

ROOF TYPE 1 (SBS ROOFING)

EXIST. CONCRETE SLAB

(REFER TO BP5 FOR

STRUCTURAL REPAIRS)

RIGID INSULATION

VAPOR RETARDER

FULLY ADHERED ROOF

MEMBRANE (PVC)

INSULATED COVER BOARD

EXIST. CONCRETE SLAB

(REFER TO BP5 FOR

STRUCTURAL REPAIRS)

RIGID INSULATION,

TAPERED

ROOF TYPE 4D (PVC ROOFING ASSEMBLY)

RIGID INSULATION

VAPOR RETARDER

TOPPING SLAB (NOT IN

SCOPE, REFER TO BP5)

FULLY ADHERED ROOF

MEMBRANE (PVC)

INSULATED COVER BOARD

EXIST. CONCRETE SLAB

(REFER TO BP5 FOR

STRUCTURAL REPAIRS)

RIGID INSULATION,

TAPERED

ROOF TYPE 4C (PVC ROOFING ASSEMBLY)

RIGID VACUUM

INSUALTION PANEL

VAPOR RETARDER

ROOF TYPE 2 (PVC ROOFING)

EXIST. CONCRETE SLAB

(REFER TO BP5 FOR

STRUCTURAL REPAIRS)

FULLY ADHERED ROOF

MEMBRANE (PVC)

ROOF TYPE 3 (METAL ROOFING)

EXISTING STRUCTURE TO

REMAIN

ALUMINUM SHEET METAL

EXISTING TEMP MEMBRANE

TO REMAIN

FULLY ADHERED ROOF

MEMBRANE (PVC)

INSULATED COVER BOARD

EXIST. CONCRETE SLAB

(REFER TO BP5 FOR

STRUCTURAL REPAIRS)

RIGID INSULATION,

TAPERED

ROOF TYPE 4A (PVC ROOFING ASSEMBLY)

RIGID INSULATION

VAPOR RETARDER

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:1

A M

G005.4

ROOF TYPES

AWAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

3" = 1'-0"G005.4

1 ROOF TYPES

02.XXX

X - XXX

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

KEYNOTES

1 2 3 4 5 6 7

G

H

J

N

P

K

M

L

INTERIOR SPACE

AREA NOT IN SCOPE

02.04002.040

02.092

02.093

M A

T C

H L

IN

E

A D

N

W .4

INTERIOR SPACE

AREA NOT IN SCOPE

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:0

A M

AD106NE.4

L1 OFFICES NE DEMO

PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

REFERRED FROM:1/8" = 1'-0"AD106NE.4 200

1 L1 OFFICES NE - ROOF DEMO PLAN

02.040 REMOVE EXISTING BUILT-UP ASPHALT ROOF AND INSULATION DOWN TO EXISTING

CONCRETE DECK.

02.092 REMOVE ASPHALT ROOFING.

02.093 EXISTING CANOPY SUPPORT RODS TO REMAIN.

DN

DN

02.XXX

X - XXX

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

KEYNOTES

8 9 10 12 13 14

G

H

J

N

P

K

M

L

02.04002.040

02.040

02.092

02.093

02.092

02.093OPEN TO

BELOW

M A

T C

H L

IN

E

A D

N

E .4

INTERIOR SPACE

AREA NOT IN SCOPE

INTERIOR SPACE

AREA NOT IN SCOPE

INTERIOR SPACE

AREA NOT IN SCOPE

02.098

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:1

A M

AD106NW.4

L1 OFFICES NW

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

REFERRED FROM:1/8" = 1'-0"AD106NW.4 200

1 L1 OFFICES NW - ROOF DEMO PLAN

02.040 REMOVE EXISTING BUILT-UP ASPHALT ROOF AND INSULATION DOWN TO EXISTING

CONCRETE DECK.

02.092 REMOVE ASPHALT ROOFING.

02.093 EXISTING CANOPY SUPPORT RODS TO REMAIN.

02.098 SALVAGE EXISTING EXTERIOR LIGHT FOR REINSTALLATION.

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

KEYNOTES

8 9 10 12 13 14

A

B

C

D

E

F

G

F O

R P

A R

A P

E T

W O

R K

R E

F E

R T

O R

E P

A

IR

W O

R K

: TREE

02.059

02.062

02.063

INTERIOR SPACE

AREA NOT IN SCOPE

INTERIOR SPACE

AREA NOT IN SCOPE

ROOFING AREA

AREA NOT IN SCOPE

ROOFING AREA

AREA NOT IN SCOPE

NOT IN SCOPE

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:2

A M

AD107SW.4

L2 OFFICES SW

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

REFERRED FROM:1/8" = 1'-0"AD107SW.4 200

1 L2 OFFICES SW ROOF DEMO PLAN

02.059 REMOVE ALL BIOLOGICAL GROWTH.

02.062 REMOVE EXISTING ROOFING AND CONCRETE ROOF DECK, REFER TO STRUCTURAL

IN FUTURE BID PACKAGE 5.

02.063 REMOVE ALL EXISTING DEBRIS.

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

1 2 3 4 5 6 7

G

H

J

N

P

K

M

L

02.06602.066

02.094

02.097

:TYP. AT PERIMETER

GUTTER

02.097

:ROOF C

02.097

:TYP. AT

PERIMETER

GUTTER

M A

T C

H L

IN

E

A D

N

W .4

MATCHLINE

1 / AD110SE.4

LIGHT WELL,

OPEN TO

ROOF BELOW

BASE SCOPE: NO WORK IN THIS AREA

ALTERNATE 1: KEYNOTES 02.066, 02.094

BASE SCOPE: NO WORK IN THIS AREA

ALTERNATE 2: KEYNOTES 02.066, 02.094

NOT IN SCOPE

NOT IN

SCOPE

5 PANELS

~ 6' - 8"

P

A N

E L S

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:2

A M

AD110NE.4

L5 OFFICES NE &

CONCOURSE ROOF

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/8" = 1'-0"AD110NE.4

1 L5 OFFICES NE & CONCOURSE - ROOF DEMO PLAN

02.066 REMOVE ALL EXISTING PRECAST CONCRETE TILE, SALVAGE (12) TILES.

02.094 REMOVE EXISTING MODIFIED BITUMINOUS BUILT-UP ROOFING DOWN TO EXISTING

CONCRETE DECK.

02.097 EXISTING FLUID APPLIED MEMBRANE TO REMAIN.

X - XXX

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

8 9 10 12 13 14

G

H

J

N

P

: AT PARAPET

K

M

L

02.065

02.066 02.096

02.094

02.097

:TYP. AT PERIMETER

GUTTER

02.097

02.097

:TYP. AT

PERIMETER

GUTTER

:ROOF C

EXISTING ACCESS TO

ROOF THRU WINDOW

M A

T C

H L

IN

E

A D

N

E .4

MATCHLINE

1 / AD110SW.4

INTERIOR SPACE

AREA NOT IN SCOPE

OPEN TO

BELOW

EXISTING SBS

ROOFING TO REMAIN

02.065

: ~18" BAND

ALONG PARAPET

BASE SCOPE: NO WORK IN THIS AREA

ALTERNATE 1: KEYNOTES 02.066, 02.094

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:2

A M

AD110NW.4

L5 OFFICES NW &

CONCOURSE ROOF

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/8" = 1'-0"AD110NW.4

1 L5 OFFICES NW & CONCOURSE - ROOF DEMO PLAN

02.065 REMOVE EXISTING FLUID APPLIED MEMBRANE.

02.066 REMOVE ALL EXISTING PRECAST CONCRETE TILE, SALVAGE (12) TILES.

02.094 REMOVE EXISTING MODIFIED BITUMINOUS BUILT-UP ROOFING DOWN TO EXISTING

CONCRETE DECK.

02.096 REMOVE ALL LOOSE AND DAMAGED CONCRETE FILL.

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

1 2 3 4 5 6 7

A

B

C

D

E

F

G

02.066

02.094

02.097

:TYP. AT PERIMETER

GUTTER

02.097

:TYP. AT

PERIMETER

GUTTER

24' - 2" 21' - 4" 26' - 4" 21' - 4 1/2" 15' - 9" 26' - 6"

/2

/2

MATCHLINE

1 / AD110NE.4

M A

T C

H L

IN

E

A D

S

W .4

NOT IN SCOPE

NOT IN

SCOPE

BASE SCOPE: NO WORK IN THIS AREA

ALTERNATE 1: KEYNOTES 02.066, 02.094

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:3

A M

AD110SE.4

L5 OFFICES SE &

CONCOURSE ROOF

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/8" = 1'-0"AD110SE.4

1 L5 OFFICES SE & CONCOURSE - ROOF DEMO PLAN

02.066 REMOVE ALL EXISTING PRECAST CONCRETE TILE, SALVAGE (12) TILES.

02.094 REMOVE EXISTING MODIFIED BITUMINOUS BUILT-UP ROOFING DOWN TO EXISTING

CONCRETE DECK.

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

8 9 10 12 13 14

A

B

C

D

E

F

G

: AT PARAPET

02.065

02.066 02.096

02.094

02.097

02.097

:TYP. AT

PERIMETER

GUTTER

:TYP. AT

PERIMETER

GUTTER

MATCHLINE

1 / AD110NW.4

M A

T C

H L

IN

E

A D

S

E .4

NOT IN SCOPE

02.065

: ~18" BAND ALONG

PARAPET

EXISTING SBS

ROOFING TO REMAIN

BASE SCOPE: NO WORK IN THIS AREA

ALTERNATE 1: KEYNOTES 02.066, 02.094

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:3

A M

AD110SW.4

L5 OFFICES SW &

CONCOURSE ROOF

DEMO PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

REFERRED FROM:1/8" = 1'-0"AD110SW.4 200

1 L5 OFFICES SW & CONCOURSE - ROOF DEMO PLAN

02.065 REMOVE EXISTING FLUID APPLIED MEMBRANE.

02.066 REMOVE ALL EXISTING PRECAST CONCRETE TILE, SALVAGE (12) TILES.

02.094 REMOVE EXISTING MODIFIED BITUMINOUS BUILT-UP ROOFING DOWN TO EXISTING

CONCRETE DECK.

02.096 REMOVE ALL LOOSE AND DAMAGED CONCRETE FILL.

UP

02.XXX

X - XXX

KEYNOTE

PHOTO TAG

DEMOLITION LEGEND

AREA OF DEMO (BASE SCOPE)

AREA OF DEMO (ALTERNATE)

EXISTING WALLS TO REMAIN

DEBRIS ON ROOF

1. BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE DURING

CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING ELEMENTS

FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER AND

ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

8. IN AREAS INDICATED FOR CEILING REMOVAL AND WALL DISMANTLING, EXISTING

SPACES MAY CONTAIN HISTORIC FINISHES AND ELEMENTS. PROTECT EXISTING

FLOORS, WALLS, COLUMNS, AND ALL ADJACENT FINISHES AND ELEMENTS FROM

DAMAGE. DO NOT PROCEED WITH DEMOLITION WORK IN THOSE AREAS UNTIL ALL

SALVAGE WORK HAS BEEN COMPLETED.

9. ALL SALVAGE WORK SHALL BE PERFORMED BY A PERSON EXPERIENCED IN THE

PRESERVATION OF HISTORIC MATERIALS AND IN ACCORANCE TO SPECIFICATIONS.

10. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS TO ENSURE

SALVAGED ITEMS ARE PROPERLY DISMANTLED, PACKAGED, AND TRANSPORTED

INTACT WITHOUT DAMAGE.

11. PRIOR TO REMOVAL OF ELEMENTS FOR DISMANTLE, CONTRACTOR SHALL CONSULT

WITH ARCHITECT FOR APPROVAL OF PIECES.

12. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS, INCLUDING

EXECUTION REQUIREMENTS, PHOTOGRAPHING, QUANTIFYING AND SCHEDULING,

TAGGING, AND STORAGE OF SALVAGED ITEMS.

13. UNSTABLE CONDITIONS, INCLUDING FINISHES, WALLS, AND STRUCTURAL

ELEMENTS, EXIST INSIDE AND OUTSIDE THE BUILDING. CONTRACTOR SHALL BE

RESPONSIBLE FOR PROVIDING TEMPORARY SAFETY MEASURES TO PROTECT

WORKERS DURING CONSTRUCTION.

14. BE AWARE THAT ACTIVE UTILITIES AND SERVICES EXIST IN THE BUILDING AND MAY

INCLUDE, BUT ARE NOT LIMITED TO, POWER, LIGHTING AND ROOF DRAINAGE

SYSTEMS. THESE ARE A MIX OF NEW AND EXISTING ELEMENTS AND MAY BE

DIFFICULT TO IDENTIFY. COORDINATE WITH CONTRACTOR TO LOCATE, IDENTIFY

AND PROTECT ANY UTILITIES AND SERVICES THAT MAY BE AFFECTED DURING

DEMOLITION.

10 12 13

J

N

P

: TYP (8) BALCONIES

K

M

02.040

27' - 5 1/2" VIF

V

IF

27' - 9 1/2" V

IF

" V

IF

INTERIOR SPACE

AREA NOT IN SCOPE

KEYNOTES

N

K

M

02.040

02.067

45' - 5" VIF

V

IF

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:3

A M

AD116.4

PENTHOUSE &

TOWER ROOF DEMO

PLANS

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/8" = 1'-0"AD116.4

1 PENTHOUSE ROOFS DEMO PLAN

1/8" = 1'-0"AD116.4

2 TOWER ROOF DEMO PLAN

02.040 REMOVE EXISTING BUILT-UP ASPHALT ROOF AND INSULATION DOWN TO EXISTING

CONCRETE DECK.

02.067 REMOVE EXISTING ROOF HATCH AND CURB

1 2 3 4 5 6 7

G

H

J

N

P

REPLACEMENT DRAIN WITH

OVERFLOW, REFER TO BP5 FOR

CONNECTION TO PLUMBING.

ROOF TYPE 4A

A560.4

A560.4

A564.4

K

M L

ROOF TYPE 3

A560.4

RD

E X

IS

T

S L O

P E

ROOF TYPE 2

/A

N

W .4

INTERIOR SPACE

AREA NOT IN SCOPE

INTERIOR SPACE

AREA NOT IN SCOPE

S L O

P E

A560.4

S L O

P E

EXISTING DRAIN AND

DOWNLEADER TO REMAIN,

REPLACE STRAINER BASKET,

REFER TO BP5 FOR CONNECTION

TO PLUMBING.

A560.4

VIF

39' - 10 1/2"

V

IF

/4

A564.4

PVC ROOFING ASSEMBLY

(ROOF TYPES 2 & 4, REFER TO G005.4)

SBS ROOFING ASSEMBLY

(ROOF TYPE 1, REFER TO G005.4)

LEGEND

ROOF/OVERFLOW DRAIN

EXIST SCUPPER LOCATION

SC

METAL ROOFING ASSEMBLY

(ROOF TYPE 3, REFER TO G005.4)

REPLACEMENT ROOFING (ALTERNATE)

ROOF DRAIN

1. THE BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE

DURING CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING

ELEMENTS FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER

AND ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NO DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122 3 4 5 6 7 8 9 10 11

1 122 3 4 5 6 7 8 9 10 11

KEY PLAN

GENERAL NOTES:

02/07/2025

PHASE 2 - BID PACKAGE 4

A u to d e s k D o c s

/B u ff a lo

C e n tr a l T e rm in a l/

B u ff a lo C e n lT e rm

R

.r v t

/8

/2

:2

:3

A M

A106NE.4

L1 OFFICES NE ROOF

PLAN

MNAW

QEA No.42245240

495 Paderewski Dr, Buffalo, NY 14212

BUFFALO CENTRAL

TERMINAL

CENTRAL TERMINAL

RESTORATION CORP.

1/8" = 1'-0"A106NE.4

1 L1 OFFICES NE - ROOF PLAN

DN

8 9 10 12 13 14

G

H

J

N

P

ROOF TYPE 4A

A560.4

A560.4

A560.4

A564.4

K

M

L

REPLACEMENT ROOF DRAIN

CONNECTED TO EXISTING PIPING,

REFER TO BP5 FOR CONNECTION

TO PLUMBING.REPLACEMENT DRAIN WITH

OVERFLOW, REFER TO BP5 FOR

CONNECTION TO PLUMBING.

ROOF TYPE 4A

ROOF TYPE 3

RD

E X

IS

T

S L O

P E

ROOF TYPE 2

RD

EXIST SLOPE

ROOF TYPE 2

A564.4

V

IF

VIF

20' - 4 1/2"

M A

T C

H L

IN

E

A N

E .4

INTERIOR SPACE

AREA NOT IN SCOPE

INTERIOR SPACE

AREA NOT IN SCOPE

A560.4

A560.4

S L O

P E

S L O

P E

EXISTING DRAIN AND

DOWNLEADER TO REMAIN,

REPLACE STRAINER BASKET,

REFER TO BP5 FOR

CONNECTION TO PLUMBING.

EXISTING DRAIN AND DOWNLEADER

TO REMAIN, REPLACE STRAINER

BASKET, REFER TO BP5 FOR

CONNECTION TO PLUMBING.

A560.4

REINSTALL EXISTING

EXTERIOR LIGHT

REINSTALL EXISTING

EXTERIOR LIGHT

VIF

32' - 10"

V

IF

/4

1. THE BUFFALO CENTRAL TERMINAL IS A BUILDING OF NATIONAL HISTORICAL

SIGNIFICANCE AND IS LISTED ON THE NATIONAL REGISTER OF HISTORIC PLACES.

TREAT THE BUILDING RESPECTFULLY. TREAT EXISTING MATERIALS AS

IRREPLACEABLE. DO NOT REMOVE, ALTER, DISFIGURE, OR OTHERWISE DAMAGE

ANY EXISTING MATERIALS, ELEMENTS, OR FINISHES UNLESS SPECIFICALLY

INDICATED HEREIN OR DIRECTED BY THE ARCHITECT. CONTRACTORS SHALL BE

RESPONSIBLE FOR PROTECTING EXISTING CONSTRUCTION FROM DAMAGE

DURING CONSTRUCTION ACTIVITIES. DO NOT REMOVE SALVAGED BUILDING

ELEMENTS FROM THE SITE WITHOUT WRITTEN PERMISSION FROM THE OWNER

AND ARCHITECT.

2. ALL WORK CONDUCTED AS PART OF THIS PROJECT MUST MEET THE SECRETARY

OF THE INTERIOR'S STANDARD FOR THE TREATMENT OF HISTORIC PROPERTIES

WITH GUIDELINES FOR PRESERVING, REHABILITATING, RESTORING, AND

RECONSTRUCTING HISTORIC BUILDINGS. THE CONTRACTOR SHALL BE FAMILIAR

WITH THESE STANDARDS PRIOR TO COMMENCING WORK.

3. ALL DRAWINGS ARE BASED ON LIMITED FIELD INVESTIGATION. VARYING AND

HIDDEN CONDITIONS MAY EXIST. CONTRACTOR SHALL VERIFY ALL EXISTING

CONDITIONS AND MEASUREMENTS. NOTIFY THE ARCHITECT REGARDING ANY

DISCREPANCY BETWEEN EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS

PRIOR TO COMMENCING WORK IN A PARTICULAR AREA.

4. CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK. REFER TO

SPECIFICATIONS FOR COORDINATION REQUIREMENTS.

5. CONTRACTORS ARE RESPONSIBLE FOR TEMPORARY PROTECTION OF EXISTING

AND HISTORIC CONSTRUCTION. REFER TO SPECIFICATIONS FOR REQUIREMENTS.

6. NOTIFY ARCHITECT AND OWNER IF THE REMOVAL OF EXISTING ELEMENTS WILL

RESULT IN UNSTABLE CONDITIONS OF THE EXISTING STRUCTURE OR SUBSTRATES

TO REMAIN. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED BY

SPECIFICATIONS.

7. HAZARDOUS MATERIALS ARE PRESENT IN THE BUILDING AND MAY BE

ENCOUNTERED IN THE WORK. IF SUSPECTED HAZARDOUS MATERIALS ARE

ENCOUNTERED, DO NO DISTURB; IMMEDIATELY NOTIFY OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

PVC ROOFING ASSEMBLY

(ROOF TYPES 2 & 4, REFER TO G005.4)

SBS ROOFING ASSEMBLY

(ROOF TYPE 1, REFER TO G005.4)

LEGEND

ROOF/OVERFLOW DRAIN

EXIST SCUPPER LOCATION

SC

METAL ROOFING ASSEMBLY

(ROOF TYPE 3, REFER TO G005.4)

REPLACEMENT ROOFING (ALTERNATE)

ROOF DRAIN

KEYNOTES

1/8" = 1' - 0" SCALE OF FEET

0'8' 8' 16'

PLAN NORTH

P A

T H

F

IL

E

N A

M E

P L O

T T

IN

G

D A

T E

T

IM

E

A

DRAWN BY:PROJECT MANAGER:

1840 WEST BROAD STREET

SUITE 400

RICHMOND, VA 23220

v 804.788.4774

QUINNEVANS.COM

M

B

C

D

E

F

G

H

J

K

L

122…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .