B08_Solicitation_(Attachment_2_-_Drawings).pdf
PDF 11 MB Posted
- Attached to
- REPLACE SEPTIC SYSTEM AT FORT LARNED Federal contract opportunity
- Solicitation number
- 140P6023B0002
About this file
This solicitation seeks to replace the septic system at Fort Laredo National Historical Park. The Department of the Interior National Park Service Midwest Region is soliciting proposals to replace an existing septic tank and leach field. Drawings providing additional details on the project scope can be found in Attachment 2 of the solicitation package. Offerors should review all attachments for full proposal requirements. Proposals are due by the date specified in the solicitation to replace failing infrastructure and ensure continued operations and visitor services at the historic site.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140P6023B0002_Amd_0005.pdf | ||
| B11_Site_Visits_(140P6023B0002_Sign-In_Sheet)_0004.pdf | ||
| Sol_140P6023B0002_Amd_0004.pdf | ||
| Sol_140P6023B0002_Amd_0003.pdf | ||
| Sol_140P6023B0002_Amd_0002.pdf | ||
| Sol_140P6023B0002_Amd_0001.pdf | ||
| B08_Solicitation_(Attachment_1_-_Specifications).pdf | ||
| Sol_140P6023B0002.pdf | ||
| B08_Solicitation_(Attachment_4_-_Construction_Wage_Determination_KS20230037_1-30-2023).pdf | ||
| B08_Solicitation_(Attachment_5_-_Limitations_on_Subcontracting_Report).xlsx | XLSX spreadsheet | |
| B08_Solicitation_(Attachment_3_-_Submittal_List).pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TITLE OF PROJECT
FORT LARNED NATIONAL HISTORIC SITE
80085
NATIONAL
SERVICE
PARK
LOCATION WITH PARK
REPLACE THE VC SEPTIC TANK AND LEACH FIELD
VISITOR CENTER
NAME OF PARK
REGION COUNTY STATE
KANSASPAWNEEMIDWEST
ENGINEER:
CIVIL
TRAVIS HEIER
KS PE NO. 21598
SITE PLAN SYMBOLOGY GENERAL SYMBOLOGY
ENGINEER:
CIVIL
ENGINEER:
CIVIL
N
E
S
S
B-1
B-2
B-3
B-4
B-5
LEGEND
SANITARY MANHOLE
WATER MANHOLE
WATER VALVE
FIRE HYDRANT
POWER POLE
ELECTRIC JUNCTION BOX/OUTLET
POWER METER
GAS TANK ACCESS
SIGN W/ ONE POST
MISCELLANEOUS POST/BOLLARD
FOUND BOUNDARY MONUMENT
BENCHMARK
EDGE OF CONCRETE
SPLIT RAIL FENCE
SANITARY SEWER PIPE
NATURAL GAS PIPE
OVER HEAD ELECTRIC CABLE
UNDERGROUND ELECTRIC CABLE
DOMESTIC WATER MAIN PIPE
CULVERT
COMMUNICATIONS CABLE
S S
G G
OHE OHE
UE UE
W W
T T
NATURAL GAS VALVE
TEST WELL
ANTENNA
SATELLITE DISH
SIGN W/ TWO POST
CONTROL POINT
FLAGPOLE
GUY WIRE
WALKWAY LIGHTING
BORE HOLE
MAJOR CONTOUR
MINOR CONTOUR
EDGE OF GRAVEL
EDGE OF ASPHALT
ENGINEER:
CIVIL
2034.056
SPT
2036.465
WDP
S
S
B-1
B-2
B-3
B-4
B-5
ENGINEER:
CIVIL
SPT
2036.465
S
S
S
S
B-1
B-2
B-3
ENGINEER:
CIVIL
2036.465
S
S
S
S
S
S
S
S
S
B-1
ENGINEER:
CIVIL
SPT
2036.465
S
S
S
S
B-1
B-2
B-3
COORDINATE POINTS TABLE
ENGINEER:
CIVIL
S
S
S
S
B-1
B-2
ENGINEER:
CIVIL
CIVIL
CIVIL
CIVIL
ONE-LINE, POWER, AND LIGHTING SYMBOLOGY
S
XXX
J
KVA
SPD
WH
DMP
LP100
208/120V
3 , 4W
ATS
B
C
D
C
D
C
A
B
C
A
7 1/2 HP
G
GFP
CB
CONDUIT RUN BETWEEN DEVICES CONCEALED IN
NON-ARCHITECTURALLY FINISHED AREAS OR UNDER
FLOOR SLAB. CONDUIT AND CONDUCTOR SIZES SHALL
BE THE SAME AS THE HOMERUN FOR THE CIRCUIT.
CURRENT TRANSFORMER (CT)
VOLTAGE TRANSFORMER (VT, PT, OR CPT)
UTILITY WATT-HOUR METER PER UTILITY REQUIREMENTS
GROUND
LIGHTNING ARRESTER
DIGITAL METERING PACKAGE
LOW VOLTAGE SURGE PROTECTIVE DEVICE
CONTROL PANEL WITH DISCONNECT SWITCH INTEGRAL OR PROVIDED
WITH ASSOCIATED EQUIPMENT
MOTOR/LOAD CONTROLLER AND SEPARATELY MOUNTED
MOTOR/LOAD CONTROLLER WITH SHORT CIRCUIT
PROTECTION AND DISCONNECT
TWO RECEPTACLES IN 2-GANG BOX UNDER COMMON COVER
PLATE
X
Y
PLUG-IN RECEPTACLE STRIP, QUANTITY AND SPACING
OF RECEPTACLES AS NOTED OR SPECIFIED
SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE,
PHASE, NUMBER OF WIRES WHEN INDICATED
Z
CONDUIT TAG OR CIRCUIT NUMBER - WIRE
AND CONDUIT SIZE AS SPECIFIED IN CIRCUIT
SCHEDULE ON THE SHEETS
CONDUIT STUBBED OUT AND CAPPED
CIRCUIT CONTINUATION
WALL MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED, ALL OR PARTIAL
EMERGENCY (INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED
X
Y
Z
NON-MOTOR LOAD WITH DESIGN KVA, KW, OR AMP
SIMPLEX RECEPTACLE
X
Y
Z
Y
X
SEPARATELY MOUNTED COMBINATION MOTOR STARTER
OR CONTROLLER; SEE ELECTRICAL ONE - LINE DIAGRAM
OR SCHEDULE FOR DESCRIPTION
NON-FUSED SWITCH, CURRENT RATING, AND
NUMBER OF POLES AS NOTED (3 POLE UON)
GROUND ROD
GROUND CABLE
Y
X
SPECIAL-PURPOSE RECEPTACLE AS DEFINED ON PLANS
DUPLEX RECEPTACLE
WALL SWITCH
Y
X
Y
X
Y
X
SINGLE-FACED CEILING OR WALL MOUNTED EXIT LIGHT;
DIRECTIONAL ARROWS (IF REQUIRED) AS INDICATED ON PLANS
DOUBLE-FACED CEILING OR WALL MOUNTED EXIT LIGHT;
DIRECTIONAL ARROWS (IF REQUIRED) AS INDICATED ON PLANS
X
Y
X
Y
EMERGENCY LIGHT, REMOTE MOUNTED HEAD
X
Y
EMERGENCY LIGHT, NUMBER OF ATTACHED HEADS AS SHOWN
CEILING/PENDANT MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED, ALL OR
PARTIAL EMERGENCY (INTERNAL OR EXTERNAL POWER SOURCE AS
INDICATED
Y
X
Z
WALL MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED
CEILING/PENDANT MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED
Y
X
Z
WALL MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED
X
Y
Z
CEILING/PENDANT/BOLLARD MOUNTED LUMINAIRE, LAMP TYPE AS
SPECIFIED
X
Y
Z
CIRCUIT HASH MARKS (WHEN INDICATED); LONG,
SHORT, SINGLE DOT, AND DOUBLE DOT REPRESENT
PHASE, NEUTRAL, EQUIPMENT GROUND, AND ISOLATED
EQUIPMENT GROUND, RESPECTIVELY. X REPRESENTS
CONDUCTOR SIZE OTHER THAN #12 IN 3/4" CONDUIT.
GROUND FAULT PROTECTION
CIRCUIT RUN BETWEEN DEVICES EXPOSED IN
NON-ARCHITECTURALLY FINISHED AREAS; CONCEALED
IN ARCHITECTURALLY FINISHED AREAS. CONDUIT AND
CONDUCTOR SIZES SHALL BE THE SAME AS THE
HOMERUN FOR THE CIRCUIT.
HOMERUN TO SOURCE (E.G. PANELBOARD, MCC)
NUMBER IN PARENTHESES REPRESENTS CONDUCTOR SIZE OTHER THAN #12
SINGLE PHASE: 2#12, 1#12G IN 3/4"C
THREE PHASE: 3#12, 1#12G IN 3/4"C
UNLESS OTHERWISE NOTED, CONDUCTOR SIZE IS FOR ENTIRE CIRCUIT,
SOURCE TO LAST DEVICE. ALSO, SEE ONE LINE DIAGRAM FOR CIRCUIT
REQUIREMENTS
CONDUIT TURNING DOWN
CONDUIT TURNING UP
PANELBOARD (LESS THAN 250V)
PANELBOARD (250V TO 600V)
JUNCTION OR PULL BOX
CONTROL PANEL INTEGRAL OR PROVIDED WITH ASSOCIATED EQUIPMENT
IC
INSTRUMENTATION / CONTROL DEVICE
PB
PUSHBUTTON
SELECTOR SWITCH
SS
OR
3-PHASE, 4-WIRE GROUNDED WYE CONNECTION
3-PHASE, 3-WIRE DELTA CONNECTION
TRANSFORMER
TRANSFER SWITCH, CURRENT RATING, AND
NUMBER OF POLES AS NOTED
GENERATOR
MOTOR WITH DESIGN HORSEPOWER
(WHEN INDICATED)
NON-FUSED SAFETY SWITCH, 30A, 3P, X
INDICATES AMP RATING GREATER THAN 30A
MEDIUM VOLTAGE CIRCUIT BREAKER
FUSIBLE SWITCH, CURRENT RATING, FUSE
RATING, AND QUANTITY AS NOTED (3 POLE
UON)
FUSED CUTOUT, CURRENT RATING, FUSE RATING,
AND QUANTITY AS NOTED
FUSE, RATING, AND NUMBER OF FUSES AS NOTED
OR
SEPARATELY MOUNTED CIRCUIT BREAKER; SEE
ELECTRICAL ONE - LINE DIAGRAM OR SCHEDULE
FOR DESCRIPTION
MAGNETIC MOTOR STARTER AND SEPARATELY
MOUNTED COMBINATION MAGNETIC MOTOR
STARTER
DISCONNECT OR DRAWOUT CONNECTION
X
Y
ATS - AUTOMATIC
MTS - MANUAL
SUBSCRIPTS:
X - INDICATES TYPE
GFCI - GROUND FAULT CIRCUIT INTERRUPTER
IG - ISOLATED GROUND
TR - TAMPER RESISTANT
PLH - PLUG LOAD HALF CONTROLLED
PLD - PLUG LOAD DUAL CONTROLLED
USB - USB CHARGING STATION
SPD - SURGE PROTECTIVE DEVICE
Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD
XXX
OR
X
Y
Z
X
Y
Z
CEILING/PENDANT/BOLLARD MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED,
EMERGENCY (INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED)
WALL MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED, EMERGENCY
(INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED)
Y
X
RECESSED FLOOR MOUNTED BOX, QUANTITY AND TYPE OF
RECEPTACLES AS INDICATED
CORD AND PLUG CONNECTION
X
ELECTRICAL EQUIPMENT ENCLOSURE: SWITCHBOARD, MOTOR
CONTROL CENTER, CONTROL PANEL, TRANSFORMER OR OTHER
EQUIPMENT AS INDICATED. ESTIMATED SIZE AS INDICATED.
WHEN USED X INDICATES EQUIPMENT TYPE.
FUSED SAFETY SWITCH, 3P, X INDICATES AMP RATING
GREATER THAN 30A, Y INDICATES FUSE SIZE
SEPARATELY MOUNTED MOTOR STARTER OR CONTROLLER;
SEE ELECTRICAL ONE-LINE DIAGRAM OR SCHEDULE FOR
DESCRIPTION.
Y
X
WALL MOUNTED FLOOD LUMINAIRE, LAMP TYPE AS SPECIFIED
POLE/STANCHION MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED
POLE/STANCHION MOUNTED LUMINAIRE, LAMP TYPE AS SPECIFIED,
EMERGENCY (INTERNAL OR EXTERNAL POWER SOURCE AS INDICATED
POLE/STANCHION MOUNTED FLOOR LUMINAIRE, LAMP TYPE AS SPECIFIED
X
Y
Z
X
Y
Z
X
Y
Z
X
Y
Z
X
20A
3P
X
100AF
80AT
3P
PHOTOCELL
PC
OSX LIGHTING CONTROL OCCUPANCY SENSOR, CEILING MOUNTED,
X INDICATES SPECIFIC TYPE AS SPECIFIED
TC TIME CLOCK
X - INDICATES TYPE
NONE
K
P
L
DM
MC
T
SINGLE POLE
DOUBLE POLE
THREE-WAY
FOUR-WAY
KEY SWITCH
PILOT LIGHT
LIGHTED HANDLE
DIMMING
MOMENTARY CONTACT
TIMER
Y - INDICATES CONTROLLING SWITCH (IF REQUIRED)
X - INDICATES LUMINAIRE TYPE PER LUMINAIRE SCHEDULE
Y - INDICATES CIRCUIT NUMBER FROM PANELBOARD
Z - INDICATES CONTROLLING SWITCH (IF REQUIRED)
NL - NIGHT LIGHT UNSWITCHED
SUBSCRIPTS:
LIGHTING FIXTURE SUBSCRIPTS:
MOTOR STARTER AND CONTROLLER SUBSCRIPTS:
A - MAGNETIC STARTER NEMA SIZE
B - STARTER TYPE
C - CONTROL DIAGRAM OR CONTROLS
SCHEDULE NUMBER (IF REQUIRED)
D - CONTROLLER TYPE
NONE
FVR
2S
RVAT
FULL VOLTAGE NON-REVERSING (FVNR)
FULL VOLTAGE REVERSING
TWO SPEED
REDUCED VOLTAGE AUTO TRANSFORMER
VFD
SS
CONT
VARIABLE FREQUENCY DRIVE
SOLID STATE
CONTACTOR
EQUIPMENT TYPES:
ATS
CP
MTS
MCC
UPS
VFD
SB
SG
T
AUTOMATIC TRANSFER SWITCH
CONTROL PANEL
MANUAL TRANSFER SWITCH
MOTOR CONTROL CENTER
UNINTERRUPTIBLE POWER SUPPLY
VARIABLE FREQUENCY DRIVE
SWITCHBOARD
SWITCHGEAR
TRANSFORMER
GENERAL NOTES:
MCCB
ICCB
LVP
MCP
TYPES:
MOLDED CASE
INSULATED CASE
LOW VOLTAGE POWER
MOTOR CIRCUIT
PROTECTOR
(RATING PER CONNECTED
LOAD)
LOW VOLTAGE CIRCUIT BREAKER (CB). RATING
AND NO. OF POLES AS SHOWN. WHEN SPECIFIC
TYPE, OTHER THAN MCCB, IS REQUIRED, X
INDICATES TYPE.
L
S
I
G
A
TRIP UNIT:
LONG TIME PICKUP
SHORT TIME PICKUP
INSTANTANEOUS PICKUP
GROUND FAULT PICKUP
ARC ENERGY REDUCTION
MODE
S
MANUAL MOTOR STARTER
X
Y
OSX LIGHTING CONTROL OCCUPANCY SENSOR, WALL MOUNTED,
X INDICATES SPECIFIC TYPE AS SPECIFIED
S
OSX
OR
X - INDICATES TYPE
HP
TE
FT
HORSEPOWER RATED
HORSEPOWER RATED WITH THERMAL ELEMENT
HORSEPOWER RATED WITH FUSETRON FUSE
Y - INDICATES SWITCH TYPE
SUBSCRIPTS:
NONE
R
TOGGLE SWITCH TYPE
ROTARY SWITCH TYPE
X
Y
X
Y
OR
X
Y
CONDUIT CONNECTION TO EQUIPMENT
X
1. THIS IS A STANDARD ELECTRICAL SYMBOLOGY SHEET. NOT
ALL SYMBOLS MAY BE USED ON THIS PROJECT.
2. SCREENING OR SHADING OF WORK IS USED TO INDICATE
EXISTING COMPONENTS OR TO DE-EMPHASIZE PROPOSED
IMPROVEMENTS TO HIGHLIGHT SELECTED TRADE WORK.
REFER TO CONTEXT OF EACH SHEET FOR USAGE.
3. SEE P&ID LEGEND SHEET FOR PROJECT SPECIFIC EQUIPMENT
SYMBOLS, EQUIPMENT ABBREVIATIONS, AND PIPING SYSTEM
ABBREVIATIONS.
X
E - ELECTRICAL
M - MECHANICAL
K - KEY
INTERLOCK: X - INDICATES TYPE
TYPES:
X
ROOM/AREA LIGHTING CONTROL TYPE,
SEE LIGHTING CONTROL SCHEDULE FOR REQUIREMENTS
(#X)
(#X)
LOW VOLTAGE DIGITAL WALL SWITCH, NUMBER INDICATES
QUANTITY OF PUSH BUTTONS PER SINGLE GANG PLATE, LETTER
INDICATES CONTROL ZONE WHEN SHOWN
a
J
OR
SV
SOLENOID VALVE
2036.465
S
S
S
S
S
S
S
S
S
B-1
G
IC ICICIC
EXISTING XFMR
MIDWEST ENERGY
EXISTING 600A MAIN
BREAKER
MTS
EXISTING 600A
TRANSFER SWITCH
P 208/120V
3PH, 4W
EXISTING 600A
PANELBOARD P
GENERAL NOTES:
1.
2.
3.
MFR
SPD
45A 3P
20A 1P
100A 3P
MFR
45A 3P
100A, 10KAIC
CP-01 MFR DUPLEX CONTROL PANEL
FURNISHED BY SPEC 33 32 13
INSTALLED BY DIV 26
208/120V, NEMA 4X
WP IN-USE
GFCI
GND BUS
#2
GROUND ROD
3#4/0, #1G, 1 1/4"C
3#6, #6G, 1"C
(INCREASED FOR VOLT DROP)
PUMP MFR SUBMERSIBLE CABLE, DIRECT BURIED
ROUTE CABLES THROUGH
ELECTRICAL COUPLING IN SIDE OF
WETWELL, SEE DETAIL 1/C9
8#14TSP, 1"C
HANDHOLE
HANDHOLE (UNCLASSIFIED)
SPLICE CABLES WITH
WATERTIGHT SPLICES
LEVEL SWITCH MFR
CABLES, DIRECT BURIED
LEVEL SWITCH, TYP OF 4
EXISTING 80KVA
STANDBY
GENERATOR
MFR
6" TYPICAL
P E
R
S
P E
C I F
I C
A T
I O
ADDITIONAL SECTION
IF REQUIRED BY
APPLICATION
MODULAR STRUT
FLAT PLATE
FITTING TYPICAL
EQUIPMENT MOUNTED
TO MODULAR STRUT
DOUBLE
MODULAR
STRUT
TYPICAL
90° ANGLE
FITTING
MODULAR STRUT ON
THE HORIZONTAL
TYPICAL
DOUBLE
MODULAR STRUT
FLAT PLATE
FITTING TYPICAL
ANGULAR FITTING
TYPICAL
6"MINIMUM
FINISH
GRADE
EQUIPMENT PAD OR
STRUCTURAL SLAB
EXPANSION ANCHOR
TYPICAL
�4'-6"
MINIMUM
1'-11"
MIMIMUM
#4@12 EACH WAY
CENTERED
FRONT VIEW SIDE VIEW
1.
2.
3.
4.
5.
6.
7.
NOTES
COMBINED EQUIPMENT LOADS PER 36" SPAN SHALL NOT EXCEED 500LBS.
PROVIDE GROUNDING FOR OUTDOOR INSTALLATIONS, PER
SPECIFICATION 26 05 00.
MODULAR STRUCT WIDTH: 1 5/8".
RACK ASSEMBLY MATERIAL: GALVANIZED PER SPECIFICATION 26 05 00.
ANCHORS: STAINLESS STEEL, 1/2" DIAMETER, 3 1/2" EMBEDMENT.
PROTECT SURFACES WITH DISSIMILAR MATERIALS.
REPAIR CUT ENDS AND DAMAGED SURFACES IN ACCORDANCE WITH
SPECIFICATION.
1/2 HEIGHT
MODULAR STRUT
P
P
P C C
CNOTE 1
BACKFILL PER
SPECIFICATION
26 05 43
WARNING TAPE
FINISH GRADE
3" MINIMUM
NOTE 4
3" MINIMUM
M
I N
I M
U M
M
I N
I M
U M
D E
P T
H
A
S
S P
E C
I F
I E
D
NOTES:
1. NUMBER OF CONDUITS AS REQUIRED FOR THE APPLICATION.
2. P SUBSCRIPT ELECTRICAL POWER OR CONTROL CONDUIT.
3. C SUBSCRIPT COMMUNICATION (TELEPHONE, DATA, INSTRUMENTATION) CONDUIT.
4. 6" MINIMUM WHEN POWER CONDUIT CONTAINS LESS THAN 1000V. 12" MINIMUM
WHENPOWER CONDUIT CONTAINS MORE THAN 1000V.
D E
P T
H
A
S
S P
E C
I F
I E
D
�3" MINIMUM
M
I N
I M
U M
GENERAL NOTES:
1. THIS DRAWING WAS PREPARED FROM LIMITED EXISTING DRAWINGS. FIELD VERIFY EXISTING CONDITIONS FOR ACCURACY
EXISTING TRANSFORMER, GENERATOR KVA RATINGS ARE UNKNOWN AT TIME OF DESIGN.
2. EXISTING MAIN BREAKER AND TRANSFER SWITCH SIZES ARE NOT SHOWN ON RECORD DRAWINGS AND SIZES ARE ASSUMED.
VERIFY THE EXACT LOCATION AND RATINGS OF EXISTING EQUIPMENT MODIFIED BY THIS INSTALLATION AND CONFIRM WITH
ENGINEER ANY DISCREPANCIES FOUND.
3. EXISTING EQUIPMENT IS SHOWN SCREENED. NEW EQUIPMENT IS SHOWN BOLD.
| Sheets and Views |
| G0 COVER - Layout1 |
| G1 LEGENDS - Plot |
| G2 ABBREVIATIONS - Plot |
| C1 TOPO - Plot |
| C2 OVERALL - Plot |
| C3 EROSION - Plot |
| C4 REMOVALS - Plot |
| C5 LAYOUT - Plot |
| C6 P&P - Plot |
| C7 DETAILS - Plot |
| C8 DETAILS - Plot |
| C9 DETAILS.dwg - Plot |
| E1 LEGEND - Plot |
| E2 LAYOUT - Plot |
| E3 DETAILS - Plot |
File details come from the government source that posted it. Updated .