B08_Solicitation_(Attachment_2_-_A06_Specifications_(PLB-Solar-Install-Instructions).pdf
PDF 293 KB Posted
- Attached to
- Solar Light Bollard Replacment and Fiber Optic Sys Federal contract opportunity
- Solicitation number
- 140P6022Q0045
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B08_Solicitation_(Attachment_8_-_Specifications_Revised_8-22-2022)_0001.pdf | ||
| Sol_140P6022Q0045_Amd_0001.pdf | ||
| B08_Solicitation_(Attachment_4_-_Technical_Questionnaire).docx | DOCX document | |
| B08_Solicitation_(Attachment_6_-_Vaccination_Certification).pdf | ||
| B08_Solicitation_(Attachment_1_-_A06_Specifications).pdf | ||
| B08_Solicitation_(Attachment_5_-_Price_Schedule).xlsx | XLSX spreadsheet | |
| Sol_140P6022Q0045.pdf | ||
| B08_Solicitation_(Attachment_7_-_Certification_of_Vaccination_Form).pdf | ||
| B08_Solicitation_(Attachment_3_-_B03_DOL_Wage_Determination_(Gage_County).pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRIOR TO INSTALL
Ensure install location receives at least 2 to 3 hours of midday sun on average. Please handle bollard with care as scratches will affect appearance and powder coat durability.
TOOLS REQUIRED
• 5/32 inch hex key
• 3/4 inch wrench or deep socket
Path
First Light Technologies Document 70-0003 27 April 2021 © Copyright First Light Technologies www.firstlighttechnologies.com info@firstlighttechnologies.com
Toll Free: 1 (844) 279-8754
HEAD
POST
BASEPLATE
PLB MODELS
Please refer to the diagram below to identify the model you are installing. This is needed for step 4.
INSTALL INSTRUCTIONS
PLB Series Solar Bollard
1. INSTALL ANCHOR BOLTS
With a one to two foot setback from the path or area to be illuminated, install concrete footing with supplied anchor bolts. Align anchor bolts to path as shown below using the supplied cardboard template to hold the bolts in position.
Footing
Anchor Bolts
Path
Footing
PLB ASYMMETRICAL
(PLB ASM)
PLB SYMMETRICAL
(PLB SYM)
First Light Technologies Document 70-0003 27 April 2021 © Copyright First Light Technologies www.firstlighttechnologies.com info@firstlighttechnologies.com
Toll Free: 1 (844) 279-8754
INSTALL INSTRUCTIONS
PLB Series Solar Bollard
3. MOUNT BOLLARD
Mount the bollard onto the baseplate, with the supplied 1/4 - 20 screws and tighten to 65 in-lbs.
6. INSTALL COMPLETE
5. PUT BACK HEAD
Place the head back on the post and fasten with the supplied 1/4 - 20 screws and tighten to 65 in-lbs.
4. CONNECT BATTERY
Remove the head of the bollard from the post and connect the battery cables. Observe the light to ensure it illuminates for approximately 20 seconds after connecting the battery. If the light does not illuminate after connecting the battery, please call us at 1 (844) 279-8754.
Head
Battery
Battery Cables
*CLICK*
Path
Path
PLB Asymmetrical Model Only Ensure the PLB ASM Optic is facing the pathway.
2. INSTALL BASEPLATE
Remove the baseplate from the bottom of the bollard and place it on the footing. Use supplied nuts to secure baseplate to footing and tighten to 45 ft-lbs.
* Supplied leveling nuts can be placed below the baseplate but are optional.
Nuts
Footing
Baseplate
PLB ASM MODEL ONLY
Ensure base plate is aligned to path as shown.