B08_Section_J_Attachment_3_Product_File_06-03-22_1.pdf
PDF 20 MB Posted
- Attached to
- DOI MATOC ONLY - BISC 251091, Attachments 1-3 Federal contract opportunity
- Solicitation number
- 140P2022R0152
About this file
This document provides details on a federal contract opportunity for roofing replacement and pavilion structure work. The National Park Service intends to issue a solicitation through its Multiple Award Task Order Contract (MATOC) for Building Florida vendors. Plans and specifications are being released early to allow MATOC vendors time to prepare proposals for the requirement. The formal solicitation will be issued in July 2022 for work at the Department of Interior with an expectation the acquisition will be approved this fiscal year. Only authorized Florida MATOC vendors will be eligible to submit proposals. An uncompressed copy of the drawings is available upon request since the file size is too large to transfer otherwise.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| B08_Section_J_Attachment_1_Specifications_06-27-22_1.pdf | ||
| B08_Section_J_Attachment_2_Drawings_06-27-22_1.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Prepared By:
Croft & Associates PC
3380 Blue Springs Road
Kennesaw, Georgia 30144
June 3, 2022
National Park Service U.S. Department of the Interior
Denver Service Center
BISC 251091
ROOF REPLACEMENT AND PAVILION STRUCTURE
FINAL CD - PRODUCT FILE
TABLE OF CONTENTS
National Park Service
BISC 251091
Corrugated Metal Roofing 2
Concrete Tile Roofing 3
Asphalt Shingle Roofing 22
Photovoltaic Collectors 30
Solar Charge Controllers 32
Solar Disconnect 34
PV Battery 36
Solar Power Distribution 38
PV Collector Roof Attachment 44
800 PAC CLAD | PAC-CLAD.COM ©2017 Petersen Aluminum Corporation
1/2” & 7/8”
CORRUGATED PANEL
PRODUCT FEATURES
` 30-year non-prorated finish warranty
` Matching screws and rivets
` Closure strips available
` Precut short lengths (5’-0” minimum)
` Panel lengths up to 38’
MATERIAL
` 43 stocked colors (24 gauge steel)
` 15 stocked colors (22 gauge steel)
` 36 stocked colors (.032 aluminum)
` 22 stocked colors (.040 aluminum)
` 29 stocked colors (.050 aluminum)
` Galvalume Plus available
FLORIDA BUILDING PRODUCT APPROVALS
Please refer to pac-clad.com or your local factory for specific product approval numbers for exposed fastener panels.
R-41
R-36
M-42
M-36
7.2
1/2” Corrugated
7/8” Corrugated
EXPOSED FASTENER
39.75”
2.667” 7/8”
37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING
34.67” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING
6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions.
7.2"
1-1/2" 36”
1-1/32"6"
3/4" 36”
1"6"
3/4" 42”
1-1/4"
12"
36”
1"13-21/32"
1-1/4" 41”
44.5”
2.667” 1/2”
42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING
40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING
R-41
R-36
M-42
M-36
7.2
1/2” Corrugated
7/8” Corrugated
EXPOSED FASTENER
39.75”
2.667” 7/8”
37.33” COVERAGE WITH 1 LAPPED RIB FOR SIDING
34.67” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING
6/8/17 - JESSICA - changed 1/2” Corrugated + 7/8 Corrugated width decimals to fractions.
7.2"
1-1/2" 36”
1-1/32"6"
3/4" 36”
1"6"
3/4" 42”
1-1/4"
12"
36”
1"13-21/32"
1-1/4" 41”
44.5”
2.667” 1/2”
42.67” COVERAGE WITH 1 LAPPED RIB FOR SIDING
40” COVERAGE WITH 2 LAPPED RIBS FOR ROOFING
7/8” CORRUGATED
1/2” CORRUGATED
SPECS
39.75" Wide, 7/8” High 44.5" Wide, 1/2" High
MATERIALS
.032 aluminum .040 aluminum .050 aluminum
24 gauge steel 22 gauge steel Galvalume Plus
CORRUGATED METAL ROOFING - BOCA CHITA BARN
Boral Roofing Build something great™
CONCRETE ROOF TILE COLLECTIONS
Proudly Serving the Florida Market for over 60 Years
Okeechobee
FLORIDA
CONCRETE TILE ROOFING - BOCA CHITA PAVILION
We focus on the latest innovations in tile manufacturing.
Our process is unique, providing pre-blended tile for the best roof aesthetic. With locations in Lake Wales, Okeechobee, and Pompano Beach we continue to maintain our commitment to our Florida customers.
The Mastery of Manufacturing
1 2221
NATURAL PROTECTION
Attic temperatures measured using identical heat sources simulating the sun’s radiation comparing standard Boral concrete roof tile to a common asphalt shingle. The result is less heat in the attic and lower energy bills.
Why Tile?
Asphalt Shingle
139° attic temperature
Concrete Tile
94° attic temperature
3 4443
Material Matters. BEAUTY MATTERS
Our concrete tiles have texture and substance, creating a true multidimensional look for your roof. Their natural colorways harmonize easily with other exterior building elements.
DURABILITY MATTERS
Boral engineered tile is specifically designed for new build and reroof, helping provide Floridians protection from the elements.
VALUE MATTERS
Boral stands behind the quality of our roof tile with a Fully Transferable, Non-Prorated Limited Lifetime Warranty.
SUSTAINABILITY MATTERS
Boral roof tile is locally made and sourced in Florida since 1958.
5 666
Color Matters.
As the market leader, we strive to enhance the curb appeal of your home. We continuously develop new colors to harmonize with the shifting architectural trends in Florida. We take pride in the color quality and blending we provide.
7 887 8
Boral concrete roof tile easily harmonizes with all three dominant architectural styles in Florida.
R A
N C
H / S
P
LIT LE
V E
L P
R A
IR
IE
S
TY
LE
M
IX
E
D
LO
O K
S
M E
D
ITE
R R
A N
E A
N
TU
S C
A N
W E
S
T IN
D
IE
S
FLO
R
ID
A
O
LD
S
TY
LE
FR
E N
C H
C O
U N
TR
Y
M O
D E
R N
M
ID
-C E
N
TU
R Y
M O
D E
R N
C O
N
TE
M P
O R
A R
Y
T R A D I T I O N A L
T R A N S I T I O N A L
C O N T E M P O R A R Y
AMERICAN ADAPTATIONS OF REGIONAL HOME
STYLES FROM OTHER TIME PERIODS OR AREAS
OF THE WORLD. OFTEN MIXED REFERENCES.
PREFERS THE CLEAN LINES OF CONTEMPORARY
ARCHITECTURE, BUT DRAWS HEAVILY ON DETAILS
AND STYLES FROM TRADITIONAL ARCHITECTURE.
CHARACTERIZED BY A PREFERENCE FOR CLEAN
LINES, OPEN CONCEPTS, DECORATION,
AMPLE LIGHT SOURCES / LARGE WINDOWS,
AND LACK OF ROUND FORMS.
STYLES
9 1010
The printed colors shown in this brochure may vary from actual available tile colors. Always use actual product samples for color selection.
BERMUDA | Smooth
PREMIUM COLORS
STANDARD COLOR
NATURAL GRAY
No Antique 1GKCS5159NN
TERRA COTTA
No Antique 1GKCS6230NN
BOCA WHITE
No Antique 1GKWU8006NN
Made to Order in Okeechobee
Made to Order in Okeechobee Made to Order in Okeechobee
DESIGNER PRODUCT
BERMUDA Smooth | Terra Cotta - No Antique
37 38
Hot air is released through the ridge
Hot air rises and is vented off the roof
Shown in Saxony® Slate 900 Butterscotch
Have you considered what is underneath your roof tile?
Boral™ Cool Roof System
Boral TileSeal® UnderlaymentBoral® Roof Tile
Boral® Vented Eave Riser
Energy Savings Every Year
Reduction in heating and cooling costs†
22%
† Steep-slope Assembly Testing of Clay and Concrete Tile with and without Cool Pigmented Colors, Oak Ridge National Laboratory, 2005.
Results vary based on profile of tile installed, location, weather and other factors.
4 5
Boral® Vented RidgeBoral® Elevated Batten System®
For more information, please visit our website at BoralRoof.com@
Air enters through vented eave riser
Eave Riser
43 44
ESTATE Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals Rake Barrel
16.5” x 13” 2-3/8" At 3" minimum headlap, 91 field tiles will cover approx. 100 square feet of roof area.
Approx: 828 lbs. 240 2.63 Approx: 2,560 lbs. NOA 18-0829.03
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1GUCS/1GUWS/1GUBS 1GRCS/1GRSS/1GRBS
GALENA Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals Rake Barrel
17" x 10" 2-11/16" At 2.5" minimum headlap, 111 field tiles will cover approx. 100 square feet of roof area.
Approx: 877 lbs. 352 3.17 Approx: 3,100 lbs. NOA 14-0416.12
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1GUCS 1GRCS
SAXONY 900 SLATE Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals 90° Rake 3-Sided Ridge 3-Sided Hip Starter
17" x 13" 1-5/32" At 3" minimum headlap, 85 field tiles will cover approx. 100 square feet of roof area.
Approx: 950 lbs. 210 2.47 Approx: 2,566 lbs. NOA 19-0207.02
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1R9CS/1R9BS 1R3CS/1R3BS 1FHCS/1FHBS
SAXONY 900 SPLIT SLATE Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals 90° Rake 3-Sided Ridge 3-Sided Hip Starter
17" x 13" 1-5/32" At 3" minimum headlap, 85 field tiles will cover approx. 100 square feet of roof area.
Approx: 950 lbs. 210 2.47 Approx: 2,566 lbs. NOA 19-0207.02
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1R9CS 1R3CS 1FHCS
PLANTATION SLATE LIKE Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals Rake V-Ridge
16.5" x 13" 1-5/32" At 3" minimum headlap, 91 field tiles will cover approx. 100 square feet of roof area.
Approx: 1,074 lbs. 210 2.31 Approx: 2,700 lbs. NOA 19-0207.02
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1GUCS 1GVCS
BERMUDA FLAT Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals Rake V-Ridge Thick Butt
16" x 10" 1-3/16" At 3" minimum headlap, 123 field tiles will cover approx. 100 square feet of roof area.
Approx: 1,255 lbs. 300 2.44 Approx: 3,300 lbs. NOA 16-0112.07
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1GUCS 1GVCS 1GNCS
BERMUDA RUSTIC SHAKE Size Height Coverage Installed Weight / Square Pieces / Pallet Squares / Pallet Weight / Pallet Approvals Rake V-Ridge
16" x 10" 1-3/16" At 3" minimum headlap, 123 field tiles will cover approx. 100 square feet of roof area.
Approx: 1,255 lbs. 300 2.44 Approx: 3,300 lbs. NOA 16-0112.07
FL 7849 (NON HVHZ*)
FL 601 (HVHZ*)
1GUCS 1GVCS
Specifications & Finishing Touches
45 4646
The printed colors shown on this sheet may vary from actual colors. Please contact your local sales office for further assistance.
ESTATE
Antigua Tan
Arizona Clay Terra Cotta
Brown Sugar Brown
Canyon Clay Terra Cotta
Carmel Terra Cotta
Casa Grande Blend Terra Cotta
Coconut Tan
Cedar Tan Tan
Copper Red
Coquina Tan
Delcrest Tan Tan
Desert Tan Tan
Espresso Blend Brown
Frosty Gray Gray
Gold Dust Terra Cotta
Light Brown Brown
Malibu Sand Tan
Natural Gray Gray
Pinto Blend Tan
Salmon Terra Cotta
Slate Gray
Spanish Clay Red
Spanish Red Red
Sterling White
Tan Tan
Terra Clay Terra Cotta
Terra Cotta Terra Cotta
Tequila Sunset Terra Cotta
Ultra White White
ESTATE BLENDS
Autumn Blend Tan
Bayside Blend Terra Cotta
Caladesi Blend Terra Cotta
Candle Flame Blend Red
Cobblestone Blend Tan
Destin Blend Tan
Driftwood Blend Terra Cotta
Harvest Blend Terra Cotta
Largo Blend Tan
Monterey Blend Terra Cotta
Navajo Sand Blend Red
Osceola Blend Terra Cotta Sienna Blend Tan
GALENA
Canyon Clay Terra Cotta
Carmel Terra Cotta
Cedar Terra Cotta
Desert Tan Tan
Nevada Clay Terra Cotta
Spanish Clay Red
Spanish Red Red
Tan Tan
Terra Cotta Terra Cotta
SAXONY® 900 SLATE
Brown Sugar Brown
Butterscotch Tan
Cedar Tan Tan
Chestnut Burnt Brown
Dark Charcoal Blend Black
Desert Tan Tan
Espresso Brown
Espresso Blend Brown
Latte Tan
Midnight Black Black
Natural Gray Gray
Slate Gray
Smoke Gray
Sterling White
Stone Mountain Blend Black
Ultra White White
SAXONY® 900 SLATE BLENDS
Bungalow Blend Brown
Cloudy Bay Blend Gray
Stone Creek Blend Tan
Suwanee Blend Brown
SAXONY® 900 SPLIT SLATE
& PLANTATION SLATE LIKE
Brown Sugar Brown
Canyon Clay Terra Cotta
Coconut Tan
Cedar Tan Tan
Cinnamon Brown Brown
Lignite Gray
Natural Gray Gray
Sierra Brown Brown Smoke Gray Slate Gray Taupe Gray
Terra CottaTan Brown BlackRed
White Gray
SAXONY® 900 SPLIT SLATE
& PLANTATION SLATE LIKE BLENDS
Cheyenne Rock Blend Gray Clam Shell Blend Brown Oyster Bay Blend Gray Pablo Creek Blend Gray Rockport Gray Blend Gray
BERMUDA SMOOTH
Boca White White Natural Gray Gray Terra Cotta Terra Cotta
BERMUDA BROOM SWEPT
Cedar Tan Tan Indian Red Red Natural Gray Gray Sierra Brown Brown Slate Gray
BERMUDA RUSTIC SHAKE
Lignite Gray Moss Tan Sandstone Tan Slate Gray Smoke Gray
BERMUDA RUSTIC SHAKE BLENDS
Weathered Ash Blend Gray
Code Approval: Complies with all building codes including but not limited to ICC ESR-1647. Some approvals are regional and only apply to locally produced products; please contact Boral Roofing before transporting product across state lines. Specifically, products used in the Miami Dade County region of Florida require PREMIUM testing and recognition. All tiles are Class A fire rated.
Disclaimer: The printed colors shown in this brochure may vary from actual available tile colors. Before making a final selection, be sure to review actual tile samples and roof installations. Please contact your local sales office for further assistance. Inadvertent errors in this publication are subject to change without notice. No performance guarantee is offered or implied beyond that expressly indicated.
Efflorescence is a temporary surface condition which is common to all concrete products. The process is caused by the chemical nature of cement. This reaction can appear as an overall chalky white bloom (a softening of color) or in more concentrated patches. It is difficult to predict how long the effects of efflorescence will last. It depends on the type and amount of deposit as well as local weather conditions. The action of carbon dioxide and rainwater will gradually remove the deposit, in most cases, leaving the original color of the roof intact without further efflorescence occurring. It is superficial and in no way affects the quality or functional properties of the tile.
Installation: According to the Tile Roofing Institute loading guidelines, “To achieve a pleasant, random blend of color for your job, care should be taken upon loading to mix the tiles.” (Source: 2015 Clay and Concrete Roof Tile Installation Manual). Please consult the Tile Roofing Institute (TRI) Installation guides for application recommendations.
Visualize Picture your new roof with Boral Roofing’s Inspiration house photo gallery on our website.
Order A Sample Deciding on the perfect roof can be overwhelming. So, instead of wondering what color or style will work, order a sample and take the guesswork out of your decision. It’s just another way Boral Roofing makes it easy to buy with confidence.
Architectural Tools Our complete suite of architectural tools, including Arcat 3-Part Specs and CAD/BIM drawings, are available for download directly from our website.
Online Ordering Manage your orders through My Boral, a simple online tool to track product orders in real time, all from the convenience of your computer, tablet or smartphone. Sign-up for e-mail alerts to notify you of your order status.
Limited Lifetime Warranty As a brand you can trust, Boral Roofing offers one of the most comprehensive, fully transferable roofing warranties available on the market today.
Follow Us On Social Media See what everyone loves about Boral Roofing and get inspired on: Facebook, Twitter, LinkedIn, YouTube, Houzz, Pinterest, Instagram.
BoralRoof.com - Imagine the Possibilities
Cover: Saxony 900 Slate Dark Charcoal Blend
Suggested Eave Metal Colors
47 484848
SAXONY 900 Slate | Slate - Black Antique 5049
2020 B oral R oofing LLC
B R
121 - 3/20
Sales Offices Phoenix, ARIZONA
Corona, CALIFORNIA
Lathrop, CALIFORNIA
Stockton, CALIFORNIA
Rialto, CALIFORNIA
Denver, COLORADO
Pompano Beach, FLORIDA
Corporate Office Boral Roofing
200 Mansell Court East, Suite 310
Roswell, GA 30076
Western Office Boral Roofing
7575 Irvine Center Drive, Ste. #100
Irvine, CA 92618
Customer Service 863.824.1289
Download a QR Code reader app for your smart phone, then take a photo to visit our website BoralRoof.com
Lake Wales, FLORIDA
Okeechobee, FLORIDA
Atlanta, GEORGIA
Kapolei, HAWAII
Henderson, NEVADA
Fort Worth, TEXAS
Katy, TEXAS
Website
ABOUT BORAL ROOFING
Boral Roofing LLC is a subsidiary of Boral USA and is the country’s largest premium provider of complete roofing and re-roofing solutions for architects as well as commercial and residential builders. Boral Roofing operates manufacturing plants throughout the U.S.
ABOUT BORAL NORTH AMERICA
Headquartered in Roswell, Georgia, Boral North America is a leader in key construction materials and building products markets with operations across the USA, Canada, and Mexico. In 2017 Boral acquired Headwaters Incorporated, expanding Boral’s product offering and manufacturing and distribution footprint across North America. In construction materials, Boral has a national footprint and industry-leading position in the processing and distribution of fly ash – a by-product of coal combustion.
In building products, Boral manufactures and supplies cladding, roof tiles, windows, and other light building products for residential and commercial markets nationally. Boral’s manufactured stone veneer includes leading brands Cultured Stone® by Boral®, Boral Versetta Stone®, Eldorado Stone®, Dutch Quality Stone®, and StoneCraft Industries®. Boral’s light building products portfolio includes Boral TruExterior® Siding & Trim – a pioneer of the innovative poly-ash category of exterior building products – as well as shutters, gable vents, mounting blocks, and tool systems. In roofing, Boral is a leading manufacturer of clay and concrete roof tiles, and also produces composite polymer and stone-coated metal roof tiles.
Boral also has a 50% share of the Meridian Brick joint venture, a leading clay and concrete brick manufacturer which was formed with Forterra Brick in 2016.
BoralAmerica.com
FORT MYERS:
16240 S Tamiami Trail Fort Myers, FL 33908 T: 863.467.3470
Visit our Design Centers:
POMPANO:
2125 NW 22nd Street Pompano Beach, FL 33069 T: 954.973.2128
ORLANDO:
2250 Lee Road Suite 80 Winter Park, FL 32789 T: 407.960.7536
TAMPA:
5411 Beaumont Center Blvd Suite 795 Tampa, FL 33634 T: 813.285.8211 www.BoralRoof.com SKU: 1GKWU8006NN Bermuda Smooth - Boca White
NOA No. 21-0323.04 Expiration Date: 06/07/26
Approval Date: 05/20/21
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing, LLC 7575 Irvine Center Drive Suite 100 Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bermuda Concrete Flat Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 19-1021.08 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
ROOFING ASSEMBLY APPROVAL
Category: Roofing Sub Category: Roofing Tiles Material: Concrete
1. SCOPE
This approves a roofing system using Bermuda Flat Concrete Roof Tile, as manufactured Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Applicant
Dimensions
Test Specifications
Product Description
Bermuda Flat Concrete Tile Length = 16" Width = 10"
TAS 112
Type 3a Class III
Flat profile, interlocking, high pressure extruded concrete roof tile equipped with two nail holes.
For mechanical, mortar or adhesive set applications.
Trim Pieces l = varies w = varies varying thickness
TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier
Test Name/Report Date Redland Technologies 7161-03
Appendix III Static Uplift Testing
PA 102 & PA 102(A)
Dec. 1991
The Center for Applied Engineering, Inc.
94-084 Static Uplift Testing PA 101 (Mortar Set)
May 1994
The Center for Applied Engineering, Inc.
94-060A Static Uplift Testing PA 101 (Adhesive Set)
March, 1994
The Center for Applied Engineering, Inc.
25-7094-2 Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New
Construction)
Oct. 1994
The Center for Applied Engineering, Inc.
25-7094-8 Static Uplift Testing PA 102 (4" Headlap, Nails, Battens)
Oct. 1994
The Center for Applied Engineering, Inc.
25-7094-5 Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof)
Oct. 1994
The Center for Applied Engineering, Inc.
25-7183-6 Static Uplift Testing PA 102 (2 Quik-Drive Screws, Direct Deck)
Feb. 1995
2.2 EVIDENCE SUBMITTED
Test Agency Test Identifier
Test Name/Report Date The Center for Applied Engineering, Inc.
25-7183-5 Static Uplift Testing
PA 102
(2 Quik-Drive Screws, Battens)
Feb. 1995
The Center for Applied Engineering, Inc.
25-7214-1 Static Uplift Testing
PA 102
(1 Quik-Drive Screw, Direct Deck)
March, 1995
The Center for Applied Engineering, Inc.
25-7214-5 Static Uplift Testing
PA 102
(1 Quik-Drive Screw, Battens)
March, 1995
Redland Technologies 7161-03 Appendix II
Wind Tunnel Testing PA 108 (Nail-On)
Dec. 1991
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing PA 108 (Nail-On)
Aug. 1994
Redland Technologies P0631-01 Wind Tunnel Testing PA 108 (Mortar Set)
July 1994
Redland Technologies P0402 Withdrawal Resistance Testing of screw
vs. smooth shank nails
Sept. 1993
The Center for Applied Engineering, Inc.
Project No. 307025 Test #MDC-77
Wind Driven Rain
PA 100
Oct. 1994
Atlanta Testing & Engineering, Inc. R1.894 R2.894 R3.894
Physical Properties
PA 112
Aug. 1994
Professional Service Industries, Inc. 395-40011-1 Physical Properties
PA 112
Feb 2004
Celotex Corporation Testing Service 520109-1 520111-4
Static Uplift Testing
PA 101
Dec. 1998
Celotex Corporation Testing Service 520191-1
Static Uplift Testing
PA 101
March 1999
Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 2004 Walker Engineering, Inc. Evaluation Calculations 25-7094 Feb 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584
25-7804b-8 25-7804-4 & 5
25-7848-6
December
Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Restoring Moment, Mg March 2004 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Nutting Engineers 13343.1 TAS 112 05/06/08 American Test Lab of South Florida RT1210.02-15 TAS 112 12/17/15
RT0201.05-21 TAS 112 02/12/21
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein.
3.5 Minimum 4/12 slope for mechanically installed tiles.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code.
4. INSTALLATION
4.1 Boral Bermuda ‘Flat’ Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (l x w )
Tile Profile
Weight-W (lbf) Length-l (ft.) Width-w (ft.)
Bermuda Flat Tile 9.7 1.33 .833
Table 2: Aerodynamic Multipliers - (ft3)
Tile Profile
(ft3) Batten Application
(ft3) Direct Deck Application
Bermuda Flat Tile 0.189 0.205
Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf)
3":12" 4":12" 5":12" 6":12" Greater than 7":12"
Bermuda Flat Tile Battens Direct Deck
Battens Direct Deck
Battens Direct Deck
Battens Direct Deck
Battens Direct Deck
N/A 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 6.35
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail-On Systems
Fastener Type Direct Deck (min 15/32” plywood)
Direct Deck (min. 19/32” plywood)
Battens
Bermuda Flat
2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw
Shank Nail
7.3 9.8 4.9
2-10d Smooth or Screw Shank Nails
14.0 18.8 7.4
1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4
1-10d Smooth or Screw Shank Nail (Field Clip)
24.3 24.3 24.2
1-10d Smooth or Screw Shank Nail (Eave Clip)
19.0 19.0 22.1
2-10d Smooth or Screw Shank Nails (Field Clip)
35.5 35.5 34.8
2-10d Smooth or Screw Shank Nails (Eave Clip)
31.9 31.9 32.2
2-10d Ring Shank Nails1 50.3 65.5 48.3
1 Installation with a 4" tile headlap and fasterners are located a min. of 2½“ from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf) for Two Patty Adhesive Set Systems
Tile Application Minimum Attachment Resistance
Bermuda Flat Tile Adhesive 31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3M™ 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf) for Single Patty Adhesive Set Systems
Tile Application Minimum Attachment Resistance
Bermuda Flat
3M™ 2-Component Foam Roof Tile Adhesive AH-160 118.94
3M™ 2-Component Foam Roof Tile Adhesive AH-160 40.45
4 Large paddy placement of 45 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160 5 Medium paddy placement of 24 grams of 3M™ 2-Component Foam Roof Tile Adhesive AH-160
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami-Dade County Product Control Approved".
Bermuda Flat Concrete Tile
LABEL (LOCATED ON UNDERSIDE OF TILE)
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
Bermuda "FLAT" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
FIELD TILE
THICK BUTT TILE
Desert Tan†
SUPREME®
Shingles
SEAL. BREATHE.DEFEND.
TOTAL PROTECTION. TOTAL CONFIDENCE.®
ASPHALT SHINGLE ROOFING - BOCA CHITA CHAPEL
Product Attributes Warranty Length* 25-Year Limited
Wind Resistance Limited Warranty*
60 MPH
Algae Resistance Limited Warranty* 10 Years
TRU PROtection® Non-Prorated Limited Warranty* Period 5 Years
Product Specifications Size 12" x 36"
Application Exposure 5"
Shingles per Bundle Not less than 26
Average Shingle Count per 3 Bundles 80
Average Coverage per 3 Bundles 100 sq. ft.
Applicable Standards and Codes
ASTM D228
ASTM D3018 (Type 1)
ASTM D3161 (Class F Wind Resistance)
ASTM D3462
ASTM D7158 (Class H Wind Resistance)
ASTM E108/UL 790 (Class A Fire Resistance)
Florida Product Approval‡
ICC-ES AC438#
Miami-Dade County Product Approval††
PRI ER 1378E01
Shasta White color meets ENERGY STAR® requirements for initial solar reflectance of 0.25 and 3-year aged solar reflectance of 0.15;
2013 California Building Energy Efficiency Standards; Title 24, Part 6 requirements; Rated by the Cool Roof Rating Council (CRRC).
Supreme® Shingles Supreme® three-tab shingles—a smart choice when you need to balance curb appeal, weather resistance and value. Supreme shingles come with a 25-Year Limited Warranty*, 60-MPH Wind Resistance Limited Warranty*, and Class A UL Fire Resistance— the industry’s highest. StreakGuard™ Protection with a 10-year Algae Resistance Limited Warranty is also available on a regional basis. Visit owenscorning.com/roofing to learn more.
ENERGY STAR® is for roofs too Similar to the energy-efficient appliances in your home, roofing products can help provide energy-saving qualities. Owens Corning® Supreme roofing shingles in Shasta White can help reduce your heating and cooling bills when installed properly. These shingles reflect solar energy, helping to decrease the amount of heat transferred to a home’s interior—and the amount of air conditioning needed to keep it comfortable. Actual savings will vary based on geographic location and individual building characteristics. Call 1-800-GET-PINK® or 1-888-STAR-YES for more information.
COLORS AVAILABLE IN ALL AREAS
Shasta White†
Aspen Gray† Autumn Brown†
Brownwood† Desert Tan†
Driftwood†
Onyx Black†
Estate Gray†
ADDITIONAL REGIONAL COLORS (See chart and map for availability)
* See actual warranty for complete details, limitations and requirements.
† Actual colors and granule blends may vary from the photo. We suggest that you view actual product on the roof to get a better idea of the finish color. Color availability subject to change without notice. Ask your professional roofing contractor for samples of colors available in your area.
†† Applies for all areas that recognize a Miami-Dade Notice of Acceptance (NOA).
‡ Applicable only in Service Area 3 (see map).
# International Code Council Evaluation Services Acceptance Criteria for Alternative Asphalt Shingles.
ENERGY STAR and the ENERGY STAR mark are registered trademarks of the U.S. Environmental Protection Agency.
^ Excludes non-Owens Corning® roofing products such as flashing, fasteners, pipe boots and wood decking.
Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein.
Weathered Wood†Teak†
Antique Silver†
Williamsburg Gray†
Forest Green† Spanish Red†
Chateau Green†
REGIONAL COLOR AVAILABILITY MAP
1 2 3 4 5 6 7 8 9 10 11 12
Amber†
Antique Silver†
Beachwood Sand†
Chateau Green†
Forest Green†
Spanish Red†
Teak†
Weathered Wood†
Williamsburg Gray†
Beachwood Sand†
Amber†
OWENS CORNING ROOFING AND ASPHALT, LLC
ONE OWENS CORNING PARKWAY
TOLEDO, OHIO, USA 43659
1-800-GET-PINK®
www.owenscorning.com/roofing
Pub. No. 10013324-I. Printed in U.S.A. October 2019.
THE PINK PANTHER ™ & © 1964–2019 Metro-Goldwyn-Mayer Studios Inc.
All Rights Reserved. The color PINK is a registered trademark of Owens Corning.
© 2019 Owens Corning. All Rights Reserved.
(Atlanta, Brookville, Denver, Irving East, Irving West, Jacksonville, Kearny, Medina, Memphis, Minneapolis, Savannah, Summit)
TOTAL PROTECTION SIMPLIFIED™
Total Protection Roofing System®^
Owens Corning® Total Protection Roofing System®^ integrates engineered Owens Corning® components that work together to address these three primary performance areas, critical to a high-performance roof, while also making it easy to understand the importance of each. With Owens Corning, it’s easy to confidently deliver total protection, beauty and peace of mind.
STARTER SHINGLES
LAMINATE SHINGLES
HIP & RIDGE SHINGLES
INTAKE VENTS
EXHAUST VENTS
SELF-ADHERED ICE
& WATER BARRIER
SYNTHETIC UNDERLAYMENT
PINK® FIBERGLAS™
BLOWN-IN
ATTIC INSULATION
NOA No.: 18-0215.01
Expiration Date: 03/20/23
Approval Date: 03/15/18
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Owens Corning Roofing and Asphalt, LLC
1 Owens Corning Parkway
Toledo, OH 43659
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Supreme AR 3 Tab Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA#12-1204.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino http://www.miamidade.gov/economy
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials 3-Tab
Deck Type: Wood
SCOPE
This approves Owens Corning Supreme AR as manufactured by Owens Corning described in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Specifications
Product Description
Supreme AR 12” x 36” TAS 110 A heavy weight, fiberglass reinforced asphalt shingle.
MANUFACTURING LOCATION
1. Atlanta, GA.
2. Irving, TX.
3. Medina, OH.
EVIDENCE SUBMITTED
Test Agency
Test Identifier Test Name/Report Date
Underwriters Laboratories, Inc. R2453 Reference
ASTM D 3462
07/07/15
PRI Asphalt Technologies, Inc. OCF-415-02-01
OCF-417-02-01
OCF-419-02-01
OCF-415-02-02
OCF-417-02-02
OCF-419-02-02
TAS 100
TAS 107/ASTM D3161
01/18/18
01/24/18
01/18/18
01/24/18
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
1. Shingles shall be labeled with the Miami-Dade Seal as seen below, or the wording “Miami-Dade County
Product Control Approved”.
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system.
DETAIL A
6"
5"
6"
DETAIL B
8"
36"
8"
6"
8"
12"
8"
2" 10" 1"
EXPOSURE
ADHESIVE STRIPENAILS
5"
END OF THIS ACCEPTANCE
PHOTOVOLTAIC COLLECTORS - BOCA CHITA BARN
032822
© 2022 LG Electronics USA, Inc. All rights reserved.
PHOTOVOLTAIC COLLECTORS - BOCA CHITA BARN
The MPPT 80 and MPPT 100 600 Vdc Solar Charge Controllers optimize the power from PV arrays for DC coupled solar and storage installations, with easy, flexible installation.
Optimum System Performance
• High power, 600 Vdc MPPT PV optimization and battery charge control
• Flexibility for oversized PV array power ratings up to 8.5 kW with the MPPT 100 or 6.8 kW with the MPPT 80
• High efficiency from PV to battery to grid, ideal for the self-consumption of solar energy
• Black start batteries from solar, providing maximum energy resilience for longer duration grid outages
• Harvest more energy with shade tolerant fast sweep MPPT algorithm
Flexible
• Flexible string sizing with a wide MPPT and PV operating voltage range
• Compatible with XW Pro and SW series hybrid inverters for a complete grid tied or off grid solar and storage solution
Easy to Install
• 2 string installations and smaller wire sizing with 600 Vdc PV arrays, allowing faster, lower cost installations
• No need for a combiner box with DC breakers or fuses
• Easy to install PV disconnect and NEC 2017 compliant rapid shutdown transmitter with the MPPT Disconnect RS accessory, UL1741 PVRSS certified solar.schneider-electric.com
MPPT PV Optimization 600 Vdc Solar Charge Controllers 6 kW MPPT 100 600 (Part Number 865-1034)
4.8 kW MPPT 80 600 (Part Number 865-1032)
Compatible with Insight
Energy Management
• Setup and configuration
• Remote monitoring & control with advanced data security
• Web and mobile app
• Multi-site management for installers
Insight Energy Management
PV SYSTEM - BOCA CHITA BARN
Technical Specifications
© 2021 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. All information is preliminary and will need to be confirmed at the time of order.
DS20210129_MPPT 80 600 | MPPT 100 600.indd
MPPT 80 600 | MPPT 100 600 | 2
MPPT 80 600 MPPT 100 600
Electrical Specifications
Max PV array open circuit voltage 600 V 600 V
MPPT voltage range 195 to 510 VDC 195 to 510 VDC
PV array operating voltage 195 to 550 V 195 to 550 V
Max. array short circuit current at STC 28 A 35 A
Max. input operating current 23 A 29 A
Max. output power 4800 W (nominal 48 V systems) 6000 W (nominal 48 V systems)
Nominal battery voltage 24 and 48 VDC 24 and 48 VDC
Battery voltage operating range 16 to 67 VDC 16 to 67 VDC
Max. output charge current 80 A 100 A
Charger regulation method Three-stage (bulk, absorption, float) plus manual equalization Two-stage (bulk, absorption) plus manual equalization
Supported battery types Flooded, GEL, AGM, Lithium-ion, Custom
Efficiency
Max. power conversion efficiency 95% (nominal 48 V), 92% (nominal 24 V)
General Specifications
Power consumption, night time < 1 W
Battery temperature sensor Included
Auxiliary output Dry contact switching up to 60 VDC, 30 VAC, 8 A
Enclosure material Enclosure material: Indoor, ventilated, aluminium sheet metal chassis
Knockout dimensions
44.0 mm, 35.0 mm , 28.2 mm, and 22.2 mm knockouts for 1-1/4, 1, ¾, and ½ inch trade size fittings
IP degree of protection IP20
Product weight 13.5 kg (29.8 lb)
Shipping weight 20.4 kg (45 lb)
Product dimensions (H x W x D) 76.0 × 22.0 × 22.0 cm (30.0 × 8.6 × 8.6 in)
Shipping dimensions (H x W x D) 113.39 × 28.68 × 31.90 cm (44.64 × 11.29 × 12.56 in)
Ambient air temperature for operation -20 °C to 65 °C (-4 °F to 149 °F), power derating above 40 °C
Storage temperature range -40 °C to 85 °C (-40 °F to 185 °F)
Operating altitude Sea level to 2000 m (6562 ft)
System network and remote monitoring Available with Insight Energy Management
Warranty Please refer to our website, SEsolar.com for the latest version of the warranty state-ment.
Part number 865-1032 865-1034
Regulatory Approvals
Safety CSA certified (UL1741, CSA 107.1) and CE marked for the Low-voltage Directive
(EN50178)
EMC
FCC and Industry Canada (Class B), CE marked for the EMC Directive (EN61000-
6-1, -6-3)
Compatible Products List
XW Pro hybrid inverter XW Pro 6848 120/240 VAC (865-6848-21), XW Pro 8548 230 VAC 865-8548-55)
XW+ hybrid inverter XW+ 8548 230 VAC (865-8548-61)
SW IEC (230 VAC) SW 4024 230 VAC (865-4024-55), SW 4048 230 VAC (865-4048-55)
SW UL (120/240 VAC) SW 4024 120/240 VAC (865-4024-21), SW 4048 120/240 VAC (865-4048-21)
XW Power Distribution Panels 865-1015-01, 865-1014-01
XW Mini Power Distribution Panels 865-1013-01
MPPT Disconnect RS and RS initiator Switch 865-1036, 865-1039
Insight Energy Management InsightHome (865-0330), InsightFacility (865-0335), Insight
Conext System Control Panel 865-1050-01
Conext Automatic Generator Start 865-1060-01
Conext Battery Monitor 865-1080-01
Easy to install and commission for Rapid Shutdown PV arrays and NEC 2017 compliance MPPT Disconnect RS
A Rapid Shutdown transmitter, arc fault detection, and PV disconnect for use with MPPT 60 150, MPPT 80 600, and MPPT 100 600 charge controllers
Solution at a glance The MPPT Disconnect RS is an accessory for the Conext™ MPPT charge controllers. It provides a disconnect for the photovoltaic (PV) circuits, an integrated Rapid Shutdown transmitter, and arc fault detection for enhanced safety.
The MPPT Disconnect RS provides simplified NEC 2017 Compliance
• Integrated Rapid Shutdown transmitter using power line communication (PLC)
• Tested and PVRSS certified with Tigo® TS4-F range of Fire Safety receivers
• Arc fault detection certified to UL 1699B
• Compatible with Conext™ MPPT 100 600, MPPT
80 600, and MPPT 60 150 charge controllers
Integrated PV Disconnect
• 2 leg disconnect, compliant with NEC
• LOTO capability
• 2 input channels with up to 2 strings per channel
Flexible Installation
• Multiple configurations with Conext™
MPPT charge controllers
• Single Rapid Shutdown Initiator Switch can be used with multiple MPPT Disconnect RS for larger systems
• Side or bottom cable entry
• Mount on either side of the Conext™ MPPT charge controllers
4 Strings 2 Strings x 2 Channels
2 Strings x 1 Channel 2 Strings x 2 Channels
MPPT 60 150Qty 2 MPPT 100/80 600MPPT 100/80 600
Charge Controller Configurations with MPPT Disconnect RS
Technical Specifications MPPT Disconnect RS
© 2021 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. Specifications are subject to change without notice.
DS20210216_MPPT Disconnect RS.indd
MPPT Disconnect RS | 2
Device short name MPPT Disconnect RS Electrical specifications Max. PV array open circuit voltage 600 VDC
Max. array short-circuit current1 32 A (25.6 A @ STC) x 2 channels
Max. and min. PV input/output wire size #6 AWG to #14 AWG (13.5 to 2.5 mm²)
Control power input 48 VDC nominal (22-60 VDC)
General specifications PV Disconnect 2 channel, 4 pole DC disconnect switch
Arc fault circuit protection2 Type 1
Rapid Shutdown PLC transmitter included; Rapid Shutdown Initiator Switch ordered separately
Network communications Xanbus
Enclosure type Type 1, indoor rated
Product weight 4.5 kg (10 lb)
Product dimensions (H x W x D) 36.8 x 22 x 14.5 cm (14.48 x 8.66 x 5.7 in)
Shipping dimensions (H x W x D) 28.5 x 44.0 x 29.0 cm (11.22 x 17.32 x 11.41 in)
Ambient air temperature for operation -20°C to +50°C (-4°F to 122°F)
Operating altitude Sea level to 2000 m (6562 ft)
Regulatory
Safety UL1741, UL1741 CRD - PV Rapid Shutdown Systems (PVRSS), UL1699B, CSA C22.2 No. 107.1-16, CSA C22.2 No. 292-18, CSA (LTR) No. AE-004-2015
EMC FCC and Industry Canada (Class B)
Rapid Shutdown Initiator Switch (Ordered separately) Enclosure type Type 4X, outdoor rated
Ambient air temperature for operation -20°C to +50°C (-4°F to 122°F)
Compatible Product Part Numbers And Example Configurations
Products Part Number 1 x MPPT 100/80 2 x MPPT 100/80 3 x MPPT 100/80 4 x MPPT 100/80 1 x MPPT 60 2 x MPPT 60 3 x MPPT 60 4 x MPPT 60
Bill of Materials
MPPT 100 600 or
MPPT 80 600
865-1034 or
865-1032
1 2 3 4 - - - -
MPPT 60 150 865-1030-1 - - - - 1 2 3 4
MPPT Disconnect RS 865-1036 1 1 2 2 1 2 3 4
RS Initiator Switch 865-1039 1 1 1 1 1 1 1 1
PV Rapid Shutdown PVRSS Certified with Tigo TS4-F, TS4-A-F, TS4-A-2F, TS4-R-F (Fire Safety)
1. Refer to MPPT Charge Controller data sheet for total allowable short circuit current
2. With Xanbus communication to MPPT charge controller
XW Pro
MPPT 100 600
MPPT Disconnect RS PV String 1 with Tigo® TS4-F
PV String 2 with Tigo® TS4-F
Power Line Communication to TS4-FBattery RS Initiator Switch
Mini PDP
Example System Solution with MPPT Disconnect RS
SimpliPhi Power’s PHI 3.8-MTM Battery utilizes the safest Lithium Ion chemistry available, Lithium Ferro Phosphate (LFP). No cobalt or explosive hazards that put customers at risk. By eliminating cobalt, the risk of thermal runaway, fire propagation, operating temperature constraints, and toxic coolants are reduced. When combined with our integrated high-performance Battery Management System (BMS), accessible 80A DC breaker On/Off switch and overcurrent protection (OCPD), the PHI 3.8-M Battery delivers safe, highly efficient and cost-effective service over the life of both residential and commercial installations, on or off-grid. Compatible with all industry-standard inverter charge controllers, the PHI 3.8-M Battery supports balance-of-system equipment and optimizes any power generation source -solar, wind, grid, generator - with scalable, on-demand energy storage solutions for critical back-up and daily savings on electricity bills.
805-640-6700 | SIMPLIPHIPOWER.COM | © SIMPLIPHI POWER, INC.
PHI 3.8-M™ BATTERY
REV202106281048© SIMPLIPHI POWER, INC.
PHI 3.8 kWh Module- Metal 24V 48V
SKU PHI-3.8-24-M PHI-3.8-48-M
DC Voltages - Nominal 25.6 VDC 51.2 VDC
Amp-Hours 151 Ah 75 Ah
Maximum Rated kWh Capacity
3.87 kWh DC @ 100% DOD
3.10 kWh DC @ 80% DOD
3.87 kWh DC @ 100% DOD
3.10 kWh DC @ 80% DOD
MAX Discharge Rate (10 minutes) 80 Amps DC (2.05 kW DC) 80 Amps DC (4.1 kW DC)
MAX Continuous Discharge Rate 75 Amps DC (1.9 kW DC) 37.5 Amps DC (1.9 kW DC)
MAX Continuous Charge Rate 75 Amps DC (1.9 kW DC) 37.5 Amps DC (1.9 kW DC)
DC Voltage Range1 24 VDC to 28 VDC 48 VDC to 56 VDC
Depth of Discharge1 up to 100%
Charging Temperature1 32° to 120° F (0° to 49° C)
Operating Temperature1 -4° to 140° F (-20° to 60° C)
Storage Temperature 6 months: 14° to 77° F (-10° to 25° C) 3 months: -4° to 113° F (-20° to 45° C)
Self-Discharge Rate < 1% per month
Cycle Life 10,000+ cycles (@ 80% DOD)
Memory Effect None
Warranty 10 Years
Weight 86 lbs. (39.0 kg)
Dimensions (W x H x D)
13.5 x 14 x 8 in. (15.5” H w/terminals) / 0.88 ft3
(34.3 x 35.6 x 20.3 cm / 0.025 m3)
Model Number PHI3.8 24V M PHI3.8 48V M
1. Max operating ranges. Refer to Installation Manual for recommended conditions.
• All specifications listed are typical/nominal and subject to change without notice
• UN 3480, Lithium ion batteries, 9, II
• UL, CE, UN/DOT and RoHS compliant components - UL 1973, UL 1642
• Designed and manufactured in California, USA
PV BATTERY - BOCA CHITA BARN
805-640-6700 | TECHSUPPORT@SIMPLIPHIPOWER.COM | SIMPLIPHIPOWER.COM
REV202106281048© SIMPLIPHI POWER, INC.
48V Battery Voltage VS. Discharged Capacity
24V Battery Voltage VS. Discharged Capacity
C/2 Discharge Rate
C/2 Discharge Rate
C/3 Discharge Rate
C/3 Discharge Rate
C/5 Discharge Rate
C/5 Discharge Rate
PHI 3.8-MTM
BATTERY
WITH WALL MOUNT BRACKET
Terminals 3/8 IN 10 MM
Battery Cables 6 AWG MINIMUM
Refer to the Integration Guide section of SimpliPhi’s Product Documentation web page for wiring instructions, inverter and/or charge controller specific settings. Must be followed to maintain PHI Warranty.
PV BATTERY - BOCA CHITA BARN
https://simpliphipower.com/product-documentation/
ConextTM XW Power Distribution Panels offer flexibility for your solar and storage system design, including:
• Mini-Power Distribution Panel and Power Distribution Panel
• XW Connection Kit
• XW Conduit Box
• Compatible Breakers solar.schneider-electric.com
XW series inverters Power Distribution Panel (PDP)
ConextTM XW Series Power Distribution Easy to install, flexible and scalable balance of system solutions
Mini Power Distribution Panel (Mini PDP)
Configuration with XW Mini PDPConfiguration with XW PDP
XW Connection Kit or Conduit Box
XW series inverters https://solar.schneider-electric.com/
XW Mini Power Distribution Panel XW Series Power Distribution | 2
XW Mini PDP Part number 865-1013-01
Standards UL
AC Distribution
Included breakers Three 60 A, 120/240 Vac, two-pole, Square D QOU260 AC breakers for AC input, bypass and AC load
(factory-installed)
Mounting DIN rail (35 mm)
Breaker expansion positions One additional expansion position for a 2 pole Square D QOU breaker
AC wiring Factory installed and labeled Arctic Ultraflex BlueTM wiring, including five #6 AWG Arctic AC cables for AC connections: L1, L2, Neutral
DC Distribution
Included breakers One GJ 250A 160 Vdc, 3/8” stud DC breaker installed
Mounting Panel mounted
Breaker expansion positions 2 expansion positions for charge controller DC breakers.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .