B08_A02_SAMA_VC_Doors-drawings.pdf

PDF 17 MB Posted

Attached to
REPLACE SAMA VISITOR CENTER DOORS Federal contract opportunity
Solicitation number
140P4321R0019
Issued by
Department of the Interior National Park Service Northeast Region

About this file

This document outlines a federal contract opportunity to replace the doors at the San Antonio Missions National Historical Park visitor center. The solicitation number is 140P4321R0019 issued by the Department of the Interior National Park Service Northeast Region to replace the doors at the SAMA visitor center. Interested parties should respond with proposals to remove and replace the existing doors, as drawings of the current door configuration are provided in an attached PDF file. The opportunity type is listed as a solicitation, indicating the government is seeking competitive bids or proposals from contractors to complete the work of replacing the doors at the specified location.

View the file

Other files for this federal contract opportunity

Other files attached to REPLACE SAMA VISITOR CENTER DOORS, newest first.
File Type Posted
B08_A01_SAMA_Replace_VC_Doors-project_manual.pdf PDF
Sol_140P4321R0019.pdf PDF
B08_A03_DOL_DBA_GD_MA20200001_07302021.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

DRAWING NO.

PKG. NO.

UNITED STATES

DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

HACE OF

NAME OF PARK

LOCATION WITHIN PARK

REGION COUNTY STATE

TITLE OF DRAWINGREVISIONMARK SHEET DATE INITA/E FIRM

SALEM MARITIME NATIONAL HISTORIC SITE

VISITOR CENTER

(HISTORIC SECOND CORPS of CADETS ARMORY)

CONSTRUCTION DOCUMENTS

REGION 1 ESSEX MASSACHUSETTS

175242

SAMA

244818

SALEM MARITIME NATIONAL HISTORIC SITE

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

MAY 2021

SAMA 244818

-- COVER SHEET

A.1 KEY PLAN; EXISTING ENTRANCES; ENTRANCE SCHEDULE

A.2 NEW ENTRANCE ASSEMBLIES (101A, 101B, 102C)

A.3 NEW ENTRANCE ASSEMBLIES (102A, 102D, 102B)

A.4 NEW ENTRANCE ASSEMBLIES (103, 104)

A.5 NEW ENTRANCE ASSEMBLIES -- DETAILS

E-1 ELECTRICAL

LIST OF DRAWINGS

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE ENTRANCES

EXISTING

PROPOSED

JG

A.1

KEY PLAN;

EXISTING ENTRANCES;

ENTRANCE SCHEDULE

04/30/21

SAMA 244818

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

Salem Maritime National Historic Site

KEY PLAN15

A.1 NOT TO SCALE

SALEM VISITOR CENTER

BROWN STREET ENTRANCE 1044

A.1 NOT TO SCALE

A.1 NOT TO SCALE

BROWN STREET ENTRANCE 1042

A.1 NOT TO SCALE

SOUTHEAST ENTRANCE 101A1

A.1 NOT TO SCALE

VESTIBULE 102, SW CORNER8

A.1 NOT TO SCALE

A.1 NOT TO SCALE

A.1 NOT TO SCALE

NORTHWEST ENTRANCE 103

A.1

NOT TO SCALE

BROWN STREET ENTRANCE 104

NORTHWEST ENTRANCE 103 EXISTING EXTERIOR THRESHOLD

SOUTHWEST ENTRANCE 102A

A.1

NOT TO SCALE

A.1

SOUTHEAST ENTRANCE 101B, WEST ELEV.

NOT TO SCALE

A.1

SOUTHWEST ENTRANCE 102B, NORTH ELEV.

NOT TO SCALE

A.1

VESTIBULE 102, SOUTHEAST CORNER DETAIL

NOT TO SCALE

A.1

SOUTHWEST ENTRANCE 102B, SOUTH ELEV.

NOT TO SCALE

A.1

SOUTHWEST ENTRANCE 102D

NOT TO SCALE NOTE: VESTIBULE 101 CONDITON IS SIMILAR.

BID OPTION #1

BID OPTION #1:

(BID OPTION #1) (BID OPTION #1) (BID OPTION #1)

BID OPTION #2:

BID OPTION #2:

(BID OPTION #2)

(BID OPTION #2) (BID OPTION #2)

(BID OPTION #2)

BID OPTION #2

BID OPTION #2

BID OPTION #2

DRAWING NO.

PMIS No.:

SHEET:

OF

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET

BOXED

STEEL

TRUSS

WOOD

BASEBD.

TRIM

BOXED

STEEL

TRUSS

TYPICAL GWB SOFFIT AND

COLUMN ENCLOSURE

ALIGN FACE OF NEW ENTRANCE

WITH FACE OF EXISTING GWB.

ARCHED TRANSOM

ASSEMBLY IS

CONCEALED ABOVE.

SCRIBED SPANDREL

GLASS TRANSOM

LIGHT ASSEMBLY

BUILT-UP (HOLLOW)

CONCRETE ARCHITRAVE

ASSEMBLY

NOTE IRREGULAR

CONDITIONS

AT GRADE.

PROTECT

EXISTING EXIT

SIGNS,

FIXTURES AND

SOFFITS,

TYPICAL.

NOTE: THIS GWB PARTITION WILL BE

MODIFIED FOR NEW ENTRANCE.

FIELD-MEASURE EXIST'G. MASONRY OPENINGS.

FIELD-

MEASURE

EXIST'G.

MASONRY

OPENINGS;

DOCUMENT

INTERNAL

BLOCKING &

ANCHORS,

TYPICAL.

175242

JG A.2

NEW ENTRANCE ASSEMBLIES

(101A, 101B, 102C)

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

Salem Maritime National Historic Site 7

SAMA 244818

04/30/21

ENTRANCE 101A - EXTERIOR ELEVATION - FULL BREAKOUT SYSTEM1

A.2

A.2

A.2

ENTRANCE 101B - EXTERIOR ELEVATION (LOOKING WEST) - FULL BREAKOUT SYSTEM

ENTRANCE 102C - INTERIOR ELEVATION (LOOKING WEST) - FULL BREAKOUT SYSTEM5

A.2

ENTRANCE 101A - INTERIOR ELEVATION (LOOKING EAST) - FULL BREAKOUT SYSTEM2

A.2

ENTRANCE 101B - INTERIOR ELEVATION (LOOKING EAST) - FULL BREAKOUT SYSTEM4

A.2

ENTRANCE 102C - EXTERIOR ELEVATION (LOOKING EAST) - FULL BREAKOUT SYSTEM6

A.2

BID OPTION #2 BID OPTION #2

BID OPTION #2 BID OPTION #2

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEET DRAWING NO.

PMIS No.:

SHEET:

OF

SCALE A

SCALE A

SCALE A

3' -8

/4

5" 7"

C

SCALE A

SCALE OF FEET

2 1 0 2 4

SCALE A

SCALE A

SCALE A

A

A

D

D

D

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

4"

12'-0" 2'-10 1/2"2'-10 1/2"

17'-9" 1/2"

3' -8

/4

5"

7' -6

7"

9' -1

1/

2" 9'

-1

1/ 2"

0"

7' -6

12'-0"

2 1/2" V.I.F.

7' -5

/4

4"

4"

2'-10 1/2" 12'-0"

FILLER ASSEMBLY, TYPICAL

LEFT AND RIGHT; FINISH TO

MATCH ENTRANCE ASSEMBLY.

D

EXISTG. BRICK

MASONRY

HINGED ACCESS

COVER

HINGED ACCESS

COVER

H

H

C

C

C

C

C

C

C

C

HINGED ACCESS

COVER

2'-10 1/2"

17'-9"

F

F

F

E

E

E

E

J

TREATMENT KEY

A

B

C

D

E

F

G

H

Prepare substrate to receive new extruded aluminum threshold. Install and bed threshold in non-shrink grout as required, ensuring level orientation and correct elevation to allow for proper door operation.

Provide and install extruded aluminum receptor channel (finish to match door assembly) IF required to conceal gaps in soffit and/or bridge gaps and irregularities between door/transom assembly frame and masonry architrave.

Using concealed metal framing (studs, channels and/or struts) and corrosion-resistant fasteners, secure new entrance assemblies to existing structural steel and/or masonry, typical.

Provide continuous backer rod and flexible sealant (in approved color) at entrance assembly perimeter (head and jambs), typical.

At sidelights, align built-up mid-rail and transom rails with adjacent door assemblies as indicated.

Reconnect and reinstall salvaged wired door- and window contact sensors, typical

In association with typical interior cutting-and-patching finish work, extend GWB partition as required to meet new entrance assembly. Provide wood baseboard trim to match and align with existing.

Provide: matching door pulls (at fully-compliant height above fin. flr.); concealed vertical rod bolt set at each leaf; lockset with interchangeable cylinder. Refer to hardware Specifications.

Provide manual hookbolt assembly incorporating integral key lock with interchangeable cylinder.

Provide extruded sill flashing beneath sidelights and uncapped vertical extrusions.

I

J

GENERAL NOTES:

1. VERIFY IN FIELD ALL CLEAR AND PROPOSED DIMENSIONS.

2. SELECT AND PROVIDE APPROPRIATE CONCEALED

BLOCKING, BRACKETS, STRUTS AND/OR ANCHOR BOLTS TO

ENSURE SECURE AND STURDY INSTALLATION OF ENTRANCE

SYSTEMS AND ASSOCIATED TRANSOM LIGHTS AND

SIDELIGHTS.

LOCATION KEY

A.5

A.5

A.5

4' -0

5-POSITION

KEY SWITCH

A

JG A.3

NEW ENTRANCE ASSEMBLIES

(102A, 102D, 102B)

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

Salem Maritime National Historic Site 7

SAMA 244818

04/30/21

ENTRANCE 102A - EXTERIOR ELEVATION - FULL BREAKOUT SYSTEM1

A.3

A.3

ENTRANCE 102A - INTERIOR ELEVATION (LOOKING WEST) - FULL BREAKOUT SYSTEM2

A.3

ENTRANCE 102D - EXTERIOR ELEVATION - FIXED SIDELITE SYSTEM ENTRANCE 102D - INTERIOR ELEVATION (LOOKING SOUTH) - FIXED SIDELITE SYSTEM4 A.3

ENTRANCE 102B - EXTERIOR ELEVATION (LOOKING NORTH) - FIXED SIDELITE SYSTEM5

A.3

ENTRANCE 102B - INTERIOR ELEVATION (LOOKING SOUTH) - FIXED SIDELITE SYSTEM6

A.3

SUB SHEET NO.DESIGNED:

CADD

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO. DRAWING NO.

PMIS No.:

SHEET:

OF

SCALE A

SCALE OF FEET

2 1 0 2 4

SCALE A

SCALE A

SCALE A

SCALE A

SCALE A SCALE A

A

A

A

D

D

G

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

EXISTG. PAINTED GWB SOFFIT

D

D

EXISTG.

BRICK

MASONRY

EXISTG. PAINTED GWB SOFFIT

14'-0"

D

14'-0"

9' -1

1/

2" 9'

-1

1/ 2"

12'-0"

2-1/2" V.I.F.

FILLER ASSEMBLY, TYPICAL

LEFT AND RIGHT; FINISH TO

MATCH ENTRANCE ASSEMBLY.

7' -5

/4

4"

9' -1

1/

2"

7' -5

/4

3/ 4"

EXISTG. PAINTED GWB SOFFIT

4" 4"

D

EXISTG.

PAINTED GWB

EXISTG.

PAINTED GWB

HINGED ACCESS

COVER THIS SIDE

HINGED ACCESS

COVER THIS SIDE

MOTION/PRESENCE

SENSOR

HINGED ACCESS

COVER

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

MOTION/PRESENCE

SENSOR

C

C

C

C

C

C C

C

C

C

APPROX. LINE OF BOXED

TRUSS IN FRONT OF

ENTRANCE ASSEMBLY.

APPROX. LINE OF BOXED

TRUSS IN FRONT OF

ENTRANCE ASSEMBLY.

F

J

TREATMENT KEY

A

B

C

D

E

F

G

H

Prepare substrate to receive new extruded aluminum threshold. Install and bed threshold in non-shrink grout as required, ensuring level orientation and correct elevation to allow for proper door operation.

Provide and install extruded aluminum receptor channel (finish to match door assembly) IF required to conceal gaps in soffit and/or bridge gaps and irregularities between door/transom assembly frame and masonry architrave.

Using concealed metal framing (studs, channels and/or struts) and corrosion-resistant fasteners, secure new entrance assemblies to existing structural steel and/or masonry, typical.

Provide continuous backer rod and flexible sealant (in approved color) at entrance assembly perimeter (head and jambs), typical.

At sidelights, align built-up mid-rail and transom rails with adjacent door assemblies as indicated.

Reconnect and reinstall salvaged wired door- and window contact sensors, typical

In association with typical interior cutting-and-patching finish work, extend GWB partition as required to meet new entrance assembly. Provide wood baseboard trim to match and align with existing.

Provide: matching door pulls (at fully-compliant height above fin. flr.); concealed vertical rod bolt set at each leaf; lockset with interchangeable cylinder. Refer to hardware Specifications.

Provide manual hookbolt assembly incorporating integral key lock with interchangeable cylinder.

Provide extruded sill flashing beneath sidelights and uncapped vertical extrusions.

I

J

FACE OF

EXISTING BOXED

TRUSS, BEYOND.

FACE OF

EXISTING BOXED

TRUSS, BEYOND.

J

GENERAL NOTES:

1. VERIFY IN FIELD ALL CLEAR AND PROPOSED DIMENSIONS.

2. SELECT AND PROVIDE APPROPRIATE CONCEALED

BLOCKING, BRACKETS, STRUTS AND/OR ANCHOR BOLTS TO

ENSURE SECURE AND STURDY INSTALLATION OF ENTRANCE

SYSTEMS AND ASSOCIATED TRANSOM LIGHTS AND

SIDELIGHTS.

EXISTING PAINTED

WOOD BASEBOARD

TRIM TO REMAIN.

EXISTING PAINTED

WOOD BASEBOARD

TRIM TO REMAIN.

EXISTING PAINTED

WOOD BASEBOARD

TRIM TO REMAIN.

EXISTING

PAINTED WOOD

BASEBOARD

TRIM TO REMAIN.

LOCATION KEY

A.5

4' -0

5-POSITION

KEY SWITCH

4' -0

5-POSITION

KEY SWITCH

JG A.4

NEW ENTRANCE ASSEMBLIES:

BASE BID ENTRANCE103;

BID OPTIONS #1 and #2

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

Salem Maritime National Historic Site 7

SAMA 244818

04/30/21

ENTRANCE 103 - EXTERIOR ELEVATION1

A.4

A.4

ENTRANCE 103 - INTERIOR ELEVATION2

A.4

ENTRANCE 104 - EXTERIOR ELEVATION ENTRANCE 104 - INTERIOR ELEVATION4

A.4

BID OPTION #1

BID OPTION #2

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO.DESIGNED:DESIGNED: DRAWING NO.

PMIS No.:

SHEET:

OF

SCALE A

SCALE OF FEET

2 1 0 2 4

SCALE A

SCALE A

SCALE A

SCALE A

A

A

B

D

D

PROVIDE PAINTED WOOD

TRIM BOARD (FASCIA) AS

REQUIRED TO CONCEAL

GAP AT EXISTING SOFFIT.

3' -3

/4

3' -6

8"

9'-1 1/16" CLEAR -- V.I.F.

V.I.F.

1'-6 1/2" 3'-0"

EQ. EQ.

EXISTG.

PAINTED GWB

EXISTG. BRICK

MASONRY

EXISTG. BRICK

MASONRY

EXISTG.

STONE

MASONRY

1/

4"

3' -7

/2

1/ 8"

1 3/4"

6'-0"

1/4" OPAQUE

SPANDREL GLASS

I.G. I.G.

I.G. I.G.

1'-5 1/2" 1'-5 1/2" V.I.F.V.I.F.

EXISTG.

PAINTED GWB

PROTECT EXISTING

EXIT SIGN TO REMAIN

7' -1

3/

4"

7' -1

0"

9'-0" MASONRY OPENING WIDTH -- V.I.F.

8' -1

1/

2"

8'-11 1/16" CLEAR -- V.I.F.

HORIZONTAL CROSSRAIL

ASSEMBLY: EXTRUDED

TOP & BOTTOM RAILS

WITH BRAKE METAL

INFILL. FILL VOID WITH

INSULATION, TYPICAL.

EXISTING RESILIENT

BASE TRIM TO REMAIN.

EXTRUDED ALUMINUM

SILL FLASHING

BENEATH SIDELIGHTS;

MATCH SIDELIGHT

FRAME FINISH.

EXTRUDED ALUMINUM SILL

FLASHING BENEATH SIDELIGHTS;

MATCH SIDELIGHT FRAME FINISH.

EXISTING PAINTED WOOD

BASEBOARD TRIM TO

REMAIN.

PROVIDE CONCEALED,

CORROSION-RESISTANT

CLIPS AND/OR ANCHORS

TO SECURE SCRIBED

FRAME TO MASONRY

OPENING.

I.G. I.G.

I.G. I.G.

EXISTG.

PAINTED GWB

C/L

9'-2" MASONRY OPENING WIDTH -- V.I.F.

9' -1

3/

8" C

LE

A R

V .I

.F

7' -1

0"

8' -5

/4

OVERHEAD POWER DOOR OPERATORS

CONCEALED IN 6"X6" EXTRUDED ENCLOSURE

FINISHED TO MATCH ENTRANCE ASSEMBLY.

CUSTOM-EXTRUDED

ALUMINUM CAP,

SCRIBED TO FIT

ARCHED MASONRY

OPENING.

EXISTING MASONRY-

PANEL ARCHITRAVE

ASSEMBLY.

H

H

F

F

E

E

TREATMENT KEY

A

B

C

D

E

F

G

H

Prepare substrate to receive new extruded aluminum threshold. Install and bed threshold in non-shrink grout as required, ensuring level orientation and correct elevation to allow for proper door operation.

Provide and install extruded aluminum receptor channel (finish to match door assembly) IF required to conceal gaps in soffit and/or bridge gaps and irregularities between door/transom assembly frame and masonry architrave.

Using concealed metal framing (studs, channels and/or struts) and corrosion-resistant fasteners, secure new entrance assemblies to existing structural steel and/or masonry, typical.

Provide continuous backer rod and flexible sealant (in approved color) at entrance assembly perimeter (head and jambs), typical.

At sidelights, align built-up mid-rail and transom rails with adjacent door assemblies as indicated.

Reconnect and reinstall salvaged wired door- and window contact sensors, typical

In association with typical interior cutting-and-patching finish work, extend GWB partition as required to meet new entrance assembly. Provide wood baseboard trim to match and align with existing.

Provide: matching door pulls (at fully-compliant height above fin. flr.); concealed vertical rod bolt set at each leaf; lockset with interchangeable cylinder. Refer to hardware Specifications.

Provide manual hookbolt assembly incorporating integral key lock with interchangeable cylinder.

Provide extruded sill flashing beneath sidelights and uncapped vertical extrusions.

I

J

II

II

(THIS AREA ABOVE SUSPENDED CEILING ASSEMBLY)

GENERAL NOTES:

1. VERIFY IN FIELD ALL CLEAR AND PROPOSED DIMENSIONS.

2. SELECT AND PROVIDE APPROPRIATE CONCEALED

BLOCKING, BRACKETS, STRUTS AND/OR ANCHOR BOLTS TO

ENSURE SECURE AND STURDY INSTALLATION OF ENTRANCE

SYSTEMS AND ASSOCIATED TRANSOM LIGHTS AND

SIDELIGHTS.

LOCATION KEY

3/

4"

1/

4"

4' -0

KEY SWITCH

1' 0"

JG A.5

NEW ENTRANCE ASSEMBLIES --

DETAILS

REPLACE VISITOR CENTER DOORS WITH

ACCESSIBLE DOORWAYS

Salem Maritime National Historic Site 7

SAMA 244818

04/30/21

A.5

ENTRANCE 102D DOOR MID-RAIL

NOT TO SCALE

A.5

ENTRANCE 102D BI-PARTING DOORS

NOT TO SCALE

A.5

ENTRANCE 102A DOOR & THRESHOLD

NOT TO SCALE

A.5

ENTRANCE 104 DOOR JAMB & SIDELIGHT

NOT TO SCALE

A.5

ENTRANCE 103 SIDELIGHT RAIL ASSEMBLY

NOT TO SCALE

A.5

ENTRANCE 103 SECTION

NOT TO SCALE

A.5

ENTRANCE 102D TRANSOM ASSEMBLY

NOT TO SCALE

A.5

ENTRANCE 102D DOOR HEAD

NOT TO SCALE

A.5

ENTRANCE 102C DOOR HEAD & SIDELIGHT

NOT TO SCALE

A.5

SECTION THROUGH 102C SIDELIGHT

NOT TO SCALE

A.5

ENTRANCE 103 HEAD RECEPTOR

NOT TO SCALE

A.5

ENTRANCE 103 OHC ENCLOSURE & TRANSOM

NOT TO SCALE

A.5

ENTRANCE 102C DOOR & SIDELIGHT

NOT TO SCALE

A.5

ENTRANCE 104 SIDELIGHT & TRANSOM LIGHT

NOT TO SCALE

A.5

ENTRANCE 102C SIDELIGHT TRANSOM

NOT TO SCALE

A.5

ENTRANCE 102C SIDELIGHT MID-RAIL

NOT TO SCALE

A.5

ENTRANCE ASSEMBLIES 102D (LEFT) AND 102A (RIGHT)

NOT TO SCALE

A.5

ENTRANCE 101A "BREAKOUT" SIDELIGHT & BRAKE METAL FILLER ASSEMBLY

NOT TO SCALE

A.5

ENTRANCE ASSEMBLIES 102C (CENTER) & 102B (UPPER RIGHT)

NOT TO SCALE

A.5

ENTRANCE 104 SIDELIGHT

NOT TO SCALE

BID OPTION #1

BID OPTION #2

BID OPTION #1

BID OPTION #1

SUB SHEET NO.DESIGNED:

CADD

DESIGNED:

TECH. REVIEW:

DATE:

TITLE OF SHEETSUB SHEET NO.DESIGNED:DESIGNED: DRAWING NO.

PMIS No.:

SHEET:

OF

PROVIDE EXTRUDED HEAD RECEPTOR

(FINISH TO MATCH ENTRANCE) IF

REQUIRED TO CONCEAL GAP BETWEEN

EXISTING MASONRY OPENING AND NEW

ENTRANCE ASSEMBLY.

TYPICAL MID-RAIL ASSEMBLY

COMBINING STANDAR EXTRUSIONS

WITH "GLAZED" AND MORTISED

BRAKE METAL PANELS. FILL VOID

WITH THERMAL INSULATION.

NOTE: ACCESS PANEL FOR

AUTOMATIC OPERATOR

LOCATED ON EXTERIOR

"BREAKOUT" SIDE FOR FIXED

SIDELITE SYSTEM.

FULL-BREAKOUT CONFIGURATION,

TYPICAL FOR ALL AUTOMATIC

SLIDING ENTRANCE SYSTEMS

FACING EAST-WEST.

A.5

A.5

A.5

INTERIOR

EXTERIOR

INTERIOR

INTERIOR

INTERIOR

EXTERIOR

EXTERIOR

INTERIOR

INTERIOR

EXTERIOR

INTERIOR

EXTERIOR

INTERIOR

ENTRANCE 102B BEYOND EXISTING GWB

COLUMN

ENCLOSURE

INTERIOR

EXTERIOR

THERMAL-BREAK EXTRUDED

THRESHOLD ASSEMBLY

THERMAL-BREAK EXTRUDED

THRESHOLD ASSEMBLY

A.5

A.5

SIDELIGHT BAY

ENTRANCE SYSTEM

ALIGN AND FASTEN-TOGETHER

SIDELIGHT ASSEMBLY AND

INTEGRAL AUTOMATIC

ENTRANCE ASSEMBLY,

TYPICAL FOR BOTH SIDES.

INTERIOR

EXTERIOR

CONTINUOUS BACKER ROD

AND SEALANT BEAD.

I.G.

I.G.

I.G.

OPAQUE

SPANDREL

GLASS PAINTED WD. FASCIA AS

REQ'D. TO CONCEAL GAP

AT EXIST'G. SOFFIT.

EXTERIOR

INTERIOR

I.G.

I.G.

TYPICAL MID-RAIL ASSEMBLY

COMBINING STANDARD EXTRUSIONS

WITH "GLAZED" AND MORTISED BRAKE

METAL PANELS. FILL VOID WITH

THERMAL INSULATION.

CONTINUOUS BACKER ROD

AND SEALANT BEAD.

CONTINUOUS

BACKER ROD AND

SEALANT BEAD.

POWER DOOR OPERATOR

IN EXTRUDED ENCLOSURE

WITH SOLID END CAPS;

FINISH SHALL MATCH

ENTRANCE ASSEMBLY.

GASKETED DOOR STOP AT PERIMETER

SPACER / GLASS STOP,

AS REQUIRED.

BID OPTION #2

1 2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

DN

DN

PANEL P1: 120/208V,

3Ø, 4W, 225A MCB

PANEL L1: 120/208V,

3Ø, 4W, 225A MCB

EX

N

EX

N

EX

N

EX

N

EX

N

EX

N

J

EX

N

SOUTHEAST

ENTRANCE

SOUTHWEST

ENTRANCE

NORTHWEST

ENTRANCE

BROWN ST

ENTRANCE

102C

102D102B

102A

101B

101A

P1-20/1 J

N

P1-20/1

P1-20/1

P1-20/1

P1-20/1

EX

X

EX

X

EX

X

EX

X

SOUTHWEST

ENTRANCE

102C

102D102B

102A

EX

X

EX

X

SOUTHEAST

ENTRANCE

101B

101A

EX

X

EX

X

1. PROVIDE 2-#10 & 1-#12G - 3/4"C FROM 20-AMPERE. 1-POLE BRANCH BREAKER IN

EXISTING PANEL P1 FOR POWER TO DOORS 102B & 102C.

2. PROVIDE 2-#10 & 1-#12G - 3/4"C FROM 20-AMPERE. 1-POLE BRANCH BREAKER IN

EXISTING PANEL P1 FOR POWER TO DOORS 102A & 102D.

3. PROVIDE A NEW EXIT SIGN, FED FROM THE EXISTING CIRCUIT, AFTER THE NEW

DOORS HAVE BEEN INSTALLED.

4. PROVIDE 2-#10 & 1-#12G - 3/4"C FROM 20-AMPERE. 1-POLE BRANCH BREAKER IN

EXISTING PANEL P1 FOR POWER TO DOORS 103.

5. REMOVE EXISTING EXIT SIGNS AND LOCK-OUT THE CIRCUIT DURING

CONSTRUCTION FOR RE-USE.

6. PROVIDE 2-#10 & 1-#12G - 3/4"C FROM 20-AMPERE. 1-POLE BRANCH BREAKER IN

EXISTING PANEL P1 FOR POWER TO DOORS 101A & 101B.

7. REMOVE LIGHT FIXTURES, EMERGENCY LIGHTS, SWITCHES, RECEPTACLE AND

OTHER ELECTRICAL DEVICES INTERFERING WITH THE NEW CONSTRUCTION.

REPLACE REMOVED DEVICES, AFTER NEW DOORS ARE INSTALLED, AND FEED

FROM THE EXISTING CIRCUITS.

SHEET NOTES:

1. THE DRAWINGS ARE CONCEPTUAL AND SHOW GENERAL CONFIGURATION. THE

DRAWINGS DO NOT NECESSARILY INDICATE ALL EXISTING DEVICES AND

COMPONENTS

2. IT IS HIGHLY RECOMMENDED THAT THE CONTRACTOR VISIT THE SITE PRIOR TO

SUBMITTING A PROPOSAL.

3. THE PROJECT WILL REPLACE THE EXISTING ENTRY DOOR PAIRS (8) WITH NEW

AUTOMATIC DOORS (7 PAIR) AND NEW MANUAL DOORS (1 PAIR).

4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE POWER TO THE NEW

AUTOMATIC DOORS (7 PAIR). NEW BRANCH CIRCUITS SHALL BE RUN CONCEALED

IN CONSTRUCTION AND ABOVE EXISTING DROPPED CEILINGS.

5. NO MORE THAN TWO AUTOMATIC DOOR OPERATORS SHALL BE FED FROM A

SINGLE 20A, 1P BRANCH BREAKER IN EXISTING PANEL P1. UTILIZE EXISTING

SPARE BREAKERS OR PROVIDE NEW, BRANCH BREAKERS LISTED FOR THE

EXISTING PANEL.

6. REMOVE ALL EXISTING LIGHTING FIXTURES, EMERGENCY LIGHTS, SWITCHES,

RECEPTACLES, FIRE ALARM AND/OR INTRUSION DEVICES AND OTHER DEVICES

INTERFERING WITH THE DEMOLITION AND/OR NEW CONSTRUCTION AS

REQUIRED. RETAIN EXISTING BRANCH CIRCUITS AND MAKE SAFE, AND LOCK-OUT,

DURING THE CONSTRUCTION. REINSTALL REMOVED DEVICES AFTER THE NEW

CONSTRUCTION IS COMPLETE.

7. ALL NEW WIRING SHALL BE CONCEALED IN CONSTRUCTION OR ABOVE EXISTING

DROPPED CEILINGS, EXCEPT IN THE ELECTRIC ROOM. WIRING SHALL BE IN EMT IN

THE ELECTRIC ROOM AND ABOVE DROPPED CEILINGS. WIRING MAY BE MC-TYPE

CABLE CONCEALED IN CONSTRUCTION.

GENERAL NOTES:

NEW WIRING ABOVE DROPPED CEILINGS OR CONCEALED IN

CONSTRUCTION.

NEW WIRING RUN BACK TO INDICATED PANEL.

NEW LED EXIT SIGN.

SYMBOLS LEGEND:

EX

N

PART PLAN DEMOLITION:

SOUTHWEST ENTRANCE

PART PLAN DEMOLITION:

SOUTHEAST ENTRANCE

PART PLAN DEMOLITION:

NORTHWEST ENTRANCE

PART PLAN DEMOLITION:

BROWN ST. ENTRANCE

P L

A N

N O

R T

H

AutoCAD SHX Text

ELECTRICAL FLOOR PLAN

AutoCAD SHX Text

VISITOR CENTER

AutoCAD SHX Text

NEW ENTRY DOORS

AutoCAD SHX Text

AutoCAD SHX Text E-1

AutoCAD SHX Text

RT

AutoCAD SHX Text

DT

AutoCAD SHX Text

HACE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE OF FEET

AutoCAD SHX Text 1/8" = 1'-0"

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

SALEM MARITIME NATIONAL HISTORICAL PARK

AutoCAD SHX Text

DERBY STREET, SALEM, MASSACHUSETTS

AutoCAD SHX Text

AutoCAD SHX Text 175242

AutoCAD SHX Text 244818

AutoCAD SHX Text

AutoCAD SHX Text

PROGRESS

AutoCAD SHX Text

DT

AutoCAD SHX Text

RT

AutoCAD SHX Text

HACE

AutoCAD SHX Text

MAY 2021

jglassman Text Box

DWG - Electrical - SAMA 244818 - 04262021 (1).pdf
Sheets and Views
NEW

File details come from the government source that posted it. Updated .