B01 Attachment 2 Septic Design.pdf

PDF 6 MB Posted

Attached to
S. Delacruz Septic System Federal contract opportunity
Solicitation number
75H70122Q00016
Issued by
Department of Health and Human Services Indian Health Service

View the file

Other files for this federal contract opportunity

Other files attached to S. Delacruz Septic System, newest first.
File Type Posted
75H70122Q00016-A00001 Ext.pdf PDF
B01 Attachment 6 IHS IEE Representation Form.pdf PDF
B01 Attachment 4 Aerial Home Location.pdf PDF
B01 Attachment 5 Measurement and Payment.pdf PDF
B01 Attachment 1 WD 20220085.pdf PDF
B01 RFQ S Delacruz Septic.pdf PDF
B01 Attachment 3 Technical Provisions.pdf PDF
B01 Attachment 7 Price Schedule.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

sschatz Typewritten Text

CLEAN-

OUTS

sschatz Line sschatz Line sschatz Line

Mound Worksheet

Number Of Bedrooms 3

Slope: 0 0

Soil Loading Rate: 0.4

DAILY DESIGN FLOW:

360 Gallons Per Day

DESIGN OF THE INFILTRATION AREA:

1. Size the Infiltration Area

a. Infiltration Rate of Filter Media : 1.0 Gal/Ft2/Day

b. Infilitrative Surface Area (Bed) = Daily Design Flow (Gal/Day)

1.0 Gal/Ft2/Day (Maximum)

1.0 Gal/Ft2/Day (Maximum)

= 360 Ft2

2. Bed Configuration

a. Bed Width (A) = 7.5 ft. (Dependent on Soil Depth. See Table 2)

b. Bed Length (B) =

= 360 FT2

7.5

= 48

DESIGN THE ENTIRE MOUND:

1. Filter Media Height

a. Filter Media Depth (D + E)

1) Depth Below Upslope Edge of Bed (D) = 2 ft or 1 ft if Mound is only for dispersal following Treatment Level B.

1.5 Feet

2) Depth at Downslope Edge of Bed (E)

a. E = D + {% Slope as Decimal x Width of Bed (A)}

1.5 + 0 = 1.5 Feet

b. Bed Depth (F) = 9 Inches (minimum for 1" lateral) in gravel

` F = 0.75 Ft

c. Cap and Topsoil

1) Depth at Bed Center (H) = 18 inches 1.5 Ft

2) Depth at Bed Edges (G) = 12 inches 1.0 Ft

2. Filter Media Length

a. End Slope Width (K) = Total Filter Media Depth at Bed Center X Horizontal Gradiant of Side Slope

K= (D + E) + F+H x

2 (3 if 3:1)

K= 3 + 2.3 x 3

K= 3.75 x 3 K= 11.25

Selected Horizontal Gradiant of Slope

Decimal Slope:

bedrooms x 120 GPD

Required Bottom Infiltrative Surface Area

Bed Width (A)

Mound Worksheet

b. Filter Media Length (L) = Bed Length + [2 x End Slope Width]

L= B+2K

L= 48 +

L= 70.5 Ft

3. Filter Media Width

Side of Slope (3 if 3:1) X Slope Correction Factor (See Table)

Slope Correction Factor = 1

J= (D + F+ G) X Horizontal Gradient x Slope Correction Factor

J= 3.3 X 3 X 1

J= 9.75

Horizontal Gradient of Slope (3 if 3:1) X Slope Correction Factor (See Table

Slope Correction Factor = 1

I= (E + F+ G) X Horizontal Gradient x Slope Correction Factor

I= 3.3 X 3 X 1

I= 9.75

W= J + A + I

W= 27.00 Ft

4. Check the Basal Area

a. Basal Area Required = Daily Design Flow

Infiltration Area

= 360 gal / day

0.4 gal / ft2 / day

= 900 Feet Squared

b. Basal Area Available = B X (A+I)

= B X (A + I)

= 48 X 17.25

= 828 Sq Feet

= L X W

= 1903.5 Sq Feet

Sufficient Basal Area? X Yes No

1) Sloping Site = Bed Length X (Bed Width + Downslope Width)

2) Level Site = Filter Media Length X Fill Width

22.5

a. Upslope Width (J) = Filter Media Depth at Upslope Edge of Bed (D+F+G) X Gradient

b. Downslope Width (I) = Filter Media Depth at Downslope Edge of Bed (E+F+G) X

c. Filter Media Width (W) = Upslope Width + Bed Width + Downslope Width

Pump Selection for a Pressurized System - Single Family Residence Project

2018-336: DE LA CRUZ

Parameters

Discharge Assembly Size

Transport Length

Transport Pipe Class

Transport Line Size

Distributing Valve Model

Max Elevation Lift

Manifold Length

Manifold Pipe Class

Manifold Pipe Size

Number of Laterals per Cell

Lateral Length

Lateral Pipe Class

Lateral Pipe Size

Orifice Size

Orifice Spacing

Residual Head

Flow Meter

'Add-on' Friction Losses

1.50

1.50

None

13.75

1.25

1.25

1/8

2.3

None inches feet inches feet feet inches feet inches inches feet feet inches feet

Calculations

Minimum Flow Rate per Orifice

Number of Orifices per Zone

Total Flow Rate per Zone

Number of Laterals per Zone

% Flow Differential 1st/Last Orifice

Transport Velocity

0.43

27.4

1.9

4.3 gpm fps

Frictional Head Losses

Loss through Discharge

Loss in Transport

Loss through Valve

Loss in Manifold

Loss in Laterals

Loss through Flowmeter

'Add-on' Friction Losses

2.3

2.2

0.0

0.2

0.2

0.0

0.0 feet feet feet feet feet

Pipe Volumes

Vol of Transport Line

Vol of Manifold

Vol of Laterals per Zone

Total Volume

5.3

0.5

10.7

16.5 gals gals gals gals

Minimum Pump Requirements

Design Flow Rate

Total Dynamic Head

27.4

23.6

PumpData Legend

System Curve:

Pump Curve:

Pump Optimal Range:

Operating Point:

Design Point:

ITT

Goulds Pumps PE Submersible

Effluent Pump

GouldsPumpsisabrandofITTWaterTechnology,Inc.
-asubsidiaryofITTIndustries,Inc.

www.goulds.com

Engineered for life

Residential Water Systems

FEATURES

■ Corrosion resistant construction.

■ Cast iron body.

■ Thermoplastic impeller and cover.

■ Upper sleeve and lower heavy duty ball bearing construction.

■ Motor is permanently lubricated for extended service life.

■ Powered for continuous operation.

■ All ratings are within the working limits of the motor.

■ Quick disconnect power cord, 20' standard length, heavy duty 16/3 SJTW with 115 or 230 volt grounding plug.

■ Complete unit is heavy duty, portable and compact.

■ Mechanical seal is carbon, ceramic, BUNA and stainless steel.

■ Stainless steel fasteners.

0 10 20 30

FEET

TO

TA

L D

YN

A

M

IC

H

EA

D

CAPACITY

GPM

m3/h

METERS

0 5 10

MODELS: PE31, PE41, PE51

HP: .33, .40, .50

40 50 60 80

PE31

PE41 1 FT

2 GPM

PE51

APPLICATIONS

Specially designed for the following uses:

• Mound Systems

• Effluent/Dosing Systems

• Low Pressure Pipe Systems

• Basement Draining

• Heavy Duty Sump/

Dewatering

SPECIFICATIONS

Pump – General:

• Discharge: 11⁄2" NPT

• Temperature: 104ºF (40ºC) maximum, continuous when fully submerged.

• Solids handling: 1⁄2" maximum sphere.

• Automatic models include a float switch.

• Manual models available.

• Pumping range: see performance chart or curve.

PE31 Pump:

• Maximum capacity: 53 GPM

• Maximum head: 25’ TDH PE41 Pump:

• Maximum capacity: 61 GPM

• Maximum head: 29' TDH PE51 Pump:

• Maximum capacity: 70 GPM

• Maximum head: 37' TDH

Goulds Pumps is ISO 9001 Registered.

C US

Tested to UL 778 and CSA 22.2 108 Standards

By Canadian Standards Association File #LR38549

ITT GOULDS PUMPS

Residential Water Systems mOTOR General:

• Single phase

• 60 Hertz

• 115 and 230 volts

• Built-in thermal overload protection with automatic reset.

• Class B insulation.

• Oil-filled design.

• High strength carbon steel shaft.

PE31 Motor:

• .33 HP, 3000 RPM

• 115 volts

• Shaded pole design PE41 Motor:

• .40 HP, 3400 RPM

• 115 and 230 volts

• PSC design PE51 Motor:

• .50 HP, 3400 RPM

• 115 and 230 volts

• PSC design

AGENCY LISTINGS

ITT GOULDS PUMPS

Residential Water Systems

DImENSIONSPERFORmANCE RATINGS

PE31

Total Head

GPM

(feet of water) 5 52 10 42 15 29 20 16 25 0

(All dimensions are in inches. Do not use for construction purposes.)

Minimum Float Switch Cord Discharge

Minimum Maximum Shipping Order No. HP Volts Amps Circuit Phase

Style Length Connection Basin Solids Weight

Breaker Diameter Size lbs/kg

PE31M

0.33

12 20 Manual / No Switch

PE31P1

Piggyback Float Switch

PE41M

7.5 15 Manual / No Switch

PE41P1

0.4

Piggyback Float Switch

PE42M

230 3.7 10 1 Manual / No Switch

20' 1.5" 18" .5" 31 / 14.1 PE42P1 Piggyback Float Switch

PE51M

115 9.5 20 Manual / No Switch

PE51P1

0.5

Piggyback Float Switch

PE52M

230 4.7 10 Manual / No Switch

PE52P1 Piggyback Float Switch

PUmP INFORmATION

PE41

8 61 10 57 15 46 20 33 25 16

9.6

2.2

6.4

15.4

12.0

.6

3.1

11∨2” NPT DISCHARGE

PE51

10 67 15 59 20 50 25 39 30 26 35 8

6.4

9.6 2.2

3.1

15.4 12.0

.6

11⁄2" NPT DISCHARGE

ITT

GouldsPumpsandtheITTEngineeredBlocksSymbolare
registeredtrademarksandtradenamesofITTIndustriesInc.

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

BPE February, 2006 © 2006 ITT Water Technology, Inc.

Engineered for life

Residential Water Systems