Text version

Arrestor Plus® Gas Tube Surge Arrestor (350 V), 45–2170 MHz, with interface types N Female Bulkhead and N Female

Product Classification Product Type Surge arrestor

General Specifications Interface N Female Bulkhead

Interface 2 N Female

Device Type dc Pass

Ordering Note CommScope® standard product in Asia Pacific

Body Style Bulkhead

Electrical Specifications Operating Frequency Band 1000 – 2000 MHz | 2000 – 2170 MHz | 45 – 1000 MHz

Average Power 400 W

Connector Impedance 50 ohm

Gas Tube Voltage 350 V

Lightning Surge Current 20 kA

Lightning Surge Current Waveform 8/20 waveform

Insertion Loss, typical 0.10 dB

APG-BNFNF-350

February 13, 2020

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 14, 2019

Outline Drawing

Mechanical Specifications Attachment Durability 25 cycles

Inner Contact Plating Gold

Interface Durability 500 cycles

Interface Durability Method IEC 61169-16:9.5

Outer Contact Plating Silver

Pressurizable No

Dimensions Height 30.99 mm | 1.22 in

Length 68.07 mm | 2.68 in

Weight 0.14 kg | 0.31 lb

Width 30.99 mm | 1.22 in

Environmental Specifications Corrosion Test Method MIL-STD-202, Method 101, Test Condition B

Immersion Depth 1 m

Immersion Test Mating Mated

APG-BNFNF-350

February 13, 2020

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the

Regulatory Compliance/Certifications

* Footnotes

Immersion Test Method IEC 60529:2001, IP68

Mechanical Shock Test Method MIL-STD-202F, Method 213B, Test Condition C

Moisture Resistance Test Method MIL-STD-202, Method 106

Operating Temperature -40 °C to +100 °C (-40 °F to +212 °F)

Storage Temperature -40 °C to +100 °C (-40 °F to +212 °F)

Thermal Shock Test Method MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C

Vibration Test Method GR 2846-CORE

Water Jetting Test Mating Mated

Water Jetting Test Method IEC 60529:2001, IP66

Standard Conditions Attenuation, Ambient Temperature 20 °C | 68 °F

Average Power, Ambient Temperature 40 °C | 104 °F

Return Loss/VSWR Frequency Band VSWR Return Loss (dB) 45–1000 MHz 1.11 26.00 1000–2000 MHz 1.17 22.00 2000–2170 MHz 1.33 17.00

Agency Classification ISO 9001:2015 Designed, manufactured and/or distributed under this quality management system

Immersion Depth Immersion at specified depth for 24 hours

Insertion Loss, typical 0.05√¯freq (GHz) (not applicable for elliptical waveguide)

APG-BNFNF-350

February 13, 2020

©2020 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the

Cable Assemblies
Surge Arrestors and Accessories
Gas Tubes
APG-BNFNF-350

File details come from the government source that posted it. Updated .