The provided document is a set of location drawings for NextGen WiFi access points related to the federal contract opportunity "7G21--621-22-704 - EHRM NextGen Wifi Upgrade". This solicitation, issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9, is for the upgrade of the nextgen WiFi system. The drawings detail the planned locations for the WiFi access points as part of this contract. No further details about required products, services, response dates, pricing, or other key information are provided in this specific document.
View the file
Other files for this federal contract opportunity
Show all 17
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VHAMOUPageD Typewritten Text Attachment 2: NextGen WiFi Access Point Location Drawings
PolyLine
VHAMOUPageD Typewritten Text Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Line
VHAMOUPageD Text Box Install CAT 6A cable from TE to AP01 using handers on the ceiling of the basement. Mount a 4x4x1 box to ceiling for AP01 to mount.
VHAMOUPageD Ellipse
VHAMOUPageD Line
VHAMOUPageD Text Box Install CAT 6A cable from TE to AP03 on 1st floor using conduit through the basement.
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Typewritten Text
VHAMOUPageD
TE
Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Line
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Run Wire Mold up from basement and along upper wall then through the wall to AP03 in Closet 103A. Install 4x4x1 box for the AP to mount to.
VHAMOUPageD Arrow
Ellipse
Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Rectangle
VHAMOUPageD Typewritten Text Install a 4x4x1 electrical box for AP01 to mount to the ceiling.
VHAMOUPageD Arrow
VHAMOUPageD PolyLine
VHAMOUPageD Text Box CAT 6A cable. Run cable and attach/hang the cable to the ceiling. Run the cable from the panel to AP01.
Arrow
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Conduit going up to 1st floor.
Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Line
VHAMOUPageD Rectangle
VHAMOUPageD PolyLine
VHAMOUPageD PolyLine
VHAMOUPageD Ellipse
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD PolyLine
VHAMOUPageD Ellipse
VHAMOUPageD Ellipse
VHAMOUPageD Rectangle
VHAMOUPageD PolyLine
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Conduit to 1st floor for AP02.
VHAMOUPageD Text Box Conduit to 1st floor for AP01.
VHAMOUPageD Text Box Conduit through the wall and to 1st floor for AP04.
VHAMOUPageD Text Box Conduit to 1st floor for AP03.
VHAMOUPageD Arrow
VHAMOUPageD Text Box Install CAT 6A cable to the APs and conduits while strapping the cable to the ceiling. Use 4x4x1 electrical boxes to mount the AP.
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Text Box Install CAT 6A cable to the APs and conduits while strapping the cable to the ceiling. Use 4x4x1 electrical boxes to mount the AP.
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Text Box Conduit through the wall and to AP02.
Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Line
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Run wire mold from the floor to the ceiling then to the AP. Mount the ap with a 4x4x1 electrical box. Pull Cat 6A cable from the basment to the APs.
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Arrow
Wire Mold
VHAMOUPageD Typewritten Text CAT 6A Cable
VHAMOUPageD Line
VHAMOUPageD Typewritten Text Conduit
VHAMOUPageD Line
VHAMOUPageD Line
VHAMOUPageD Ellipse
VHAMOUPageD PolyLine
VHAMOUPageD Line
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Mount APs with electrical box 4x4x1. Conduit to the Attic for the CAT 6A cable to come from the Attic
VHAMOUPageD Text Box Mount APs with electrical box 4x4x1. Conduit to the Attic for the CAT 6A cable to come from the Attic
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Text Box Route CAT 6A cable through the Attic and down through the ceiling to the APs.
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Text Box Condi=uit from the Basement to the Attic must be large enough for 3 CAT 6A cables.
VHAMOUPageD PolyLine
VHAMOUPageD Text Box Install wire mold from the floor to the ceiling then to AP04. Run the CAT 6A cable from the basement through the wire mold to AP04. Install a 4x4x1 electrical box for the AP to mount.
VHAMOUPageD Text Box Run the Cat 6A Cable throught the attic over to AP02 and come down from the attic. Run in conduit if required. Install a 4x4x1 Box to mount AP02.
VHAMOUPageD Arrow
VHAMOUPageD Line
VHAMOUPageD
Cat 6A Cable
VHAMOUPageD Text Box The TR ceiling is in a warehouse that is open above the TR room. Run conduit out the top for the TR along the wall to AP03. Then run the Cat 6A cable from the TR to the AP03
VHAMOUPageD Arrow
VHAMOUPageD Arrow
VHAMOUPageD Line
VHAMOUPageD
Conduit
| 03-02 Attachment 2- NextGen WIFI Access Point Location Drawings |
| Net Gen WIFI Bldg. 15 Basement |
| Net Gen WIFI Bldg. 15 1st Floor |
| Net Gen WIFI Bldg. 35 Basement |
| Net Gen WIFI Bldg. 37 Ground |
| Net Gen WIFI Bldg. 39 Basement |
| Net Gen WIFI Bldg. 39 1st floor |
| Net Gen WIFI Bldg. 39 2nd floor |
| Net Gen WIFI Bldg. 41 Basement |
| Net Gen WIFI Bldg. 41 1st floor |
| Net Gen WIFI Bldg. 41 2nd floor |
| Net Gen WIFI Bldg. 42 Basement |
| Net Gen WIFI Bldg. 42 1st Floor |
| Net Gen WIFI Bldg. 43 Basement |
| Net Gen WIFI Bldg. 43 2nd floor |
| Net Gen WIFI Bldg. 44 Basement |
| Net Gen WIFI Bldg. 44 1st Floor |
| Net Gen WIFI Bldg. 44 2nd floor |
| Net Gen WIFI Bldg. 46 Basement |
| Net Gen WIFI Bldg. 47 Basement |
| Net Gen WIFI Bldg. 47 1st floor |
| Net Gen WIFI Bldg. 69 3rd floor |
| Net Gen WIFI Bldg. 205 Ground |