Attachment 1 - Vyntus Salient Characteristics.pdf

PDF 126 KB Posted

Attached to
USAFA - VYNTUS BODY PC Diffusion System Federal contract opportunity
Solicitation number
FA700022Q0062
Issued by
Department of the Air Force Headquarters Air Force Academy

View the file

Other files for this federal contract opportunity

Other files attached to USAFA - VYNTUS BODY PC Diffusion System, newest first.
File Type Posted
FA700022Q0062 Combined Synopsis Solicitation.pdf PDF
Attachment 2 - Vyntus Brand Name J and A_Redacted.pdf PDF
Attachment 4 - Provisions and Clauses.pdf PDF
Attachment 3 - DFARS 252.225-7000 Buy American Certificate.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Vyntus Salient Characteristics Solicitation Number FA700022Q0062

Essential Characteristics:

Measurement Capabilities:

• Spirometry ( FVC, FEV1, Flow Volume Loop)

• Slow Vital Capacity ( SVC, ERV, IC)

• Maximum Voluntary Ventilation (MVV).

• CO-Diffusion SB Real-time: with continuous, high speed gas analysis for calculation of DLCO, VA, DL/VA.

• CO Diffusion Intrabreath: an alternative diffusion method with a non-breath hold maneuver with continuous, high speed gas analysis for calculation of DLCO, VA, DL/A etc.

• Pre and post medication testing for therapy control.

• Maximal Inspiratory and Expiratory Pressures (MIP/MEP)

• Bronchial Challenge Testing

• Lung Volumes and Airway Resistance by Body Plethysmography (TLC, FRC, sRaw, etc.)

Hardware:

• Glass cabin with open vision on all four sides to avoid claustrophobia.

• 1100L Volume Cabin

• Electromagnetic door closure not requiring any gas to seal cabin.

• Door can be opened by patient via release button inside the cabin

• Stable handgrip for safe an easy entry and exit

• Bench that is approved for 551lbs.

• Flexible, telescoping arm that extends 25" outside the cabin to test patients in wheelchairs or for whatever reason cannot enter the cabin.

• Low entry step that is less than 3"

• Digital Pressure Compensation

• 3 frequency calibration

• LED status lights

• Fast Multigas analyzer (CO/CH4) for the Diffusion measurements with response time <150ms.

• Fully digital, high speed CO2 analyzer, based on infrared absorption

• Only requires a single gas tank

• USB ambient module for continuously reading ambient data temperature, humidity and barometric pressure.

• Factory Calibrated Ultrasonic sensor with 1000Hz sampling rate and double shot technology.

Volume accuracy of 2.5%, meeting 2017 ATS/ERS DLCO guidelines.

• Waterproof ultrasonic flow sensor

• Quiet and fast magnetically-controlled shutter system

• Shutter system is free of balloons

• Validated bacterial/viral filters available along with complete hygiene documentation and concept.

• Optional Height adjustable cart for sitting and standing position to accommodate the needs of the technician

• Keyboard and mouse that is sealed so that it can be cleaned and disinfected.

General software functions:

• Compliance with ATS/ERS guidelines including the 2017 DLCO and reporting guidelines.

• Resting and Panting testing techniques available

• Digital Questionnaire can be integrated in to patient record.

• Mobile review application to allow physicians to interpret testing from any device.

• Digital signature for reports

• Report output format selectable as print, monitor view, PDF, TIFF, RTF, JPG

• Online coaching for technician and patient

• Quality feedback based on ATS/ERS guidelines