Attachment 1_SOW.docx

DOCX document 19 KB Posted

Attached to
N063--PAC System RFQ Federal contract opportunity
Solicitation number
36C24124Q0069
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1

About this file

This document contains a performance work statement and supplemental contract requirements for upgrading a physical access control system at a Department of Veterans Affairs medical center. The scope of work involves installing a new PAC system capable of supporting 28 card readers, 2 intrusion systems, and 1 scrambler. Specific tasks include installing 7 new panels/boards to manage the card readers and integrate them into the upgraded system, installing 1 controller board, 12 reader boards, and 8 backup batteries with housing. The performance period is 30 days from award. Services will be performed Monday through Friday from 7:00 am to 4:30 pm, excluding federal holidays, and any off-hours work must be coordinated with the contracting officer's representative. The supplemental requirements mandate that contractor employees comply with COVID-19 documentation, screening, notification, and compliance procedures.

View the file

Other files for this federal contract opportunity

Other files attached to N063--PAC System RFQ, newest first.
File Type Posted
Electrical First Floor Security Plan Drawings.pdf PDF
36C24124Q0069_3.docx DOCX document
Site Visit Questions and Answers.pdf PDF
36C24124Q0069_2.docx DOCX document
Attachment 2_Price Schedule.xlsx XLSX spreadsheet
Attachment 3_Past Performance Worksheet.xlsx XLSX spreadsheet
Combined Synopsis-Solicitation.docx DOCX document
36C24124Q0069_1.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Performance Work Statement Department of Veterans Affairs (VA) Medical Center, Leeds MA Primary Care PAC System

1. GENERAL

The VA Central Western Mass requires upgrades to the Physical Access Control (PAC) system in Building 1. The current system was designed before Electronic Health Record System (EHRM) updates making it outdated and is not compatible with EHRM requirements. Special programing and equipment will be required to synchronize the upgraded equipment to the campus system.

Place of Performance:

421 N. Main St, Leeds MA Building 1 (Primary Care Section)

2. PROJECT SCOPE OF WORK

Install PAC System capable of sustaining 28x card readers, 2x intrusion systems, and 1x scrambler. Work shall consist of the following:

a) Install 7x new panel/boards that can manage 28x card readers, program the board and integrate to the PAC System

b) Install 1x controller board and connect to the system

c) Install 12x reader boards and connect to the system

d) Install 8x backup batteries including housing, and connect to the system

e) Program all equipment into updated PAC system

3. The performance period for this work is 30 days from time of award, unless other time frames are approved in writing by the contracting office with no options to renew.

a) Services will be performed during business hours 7:00am – 4:30 pm. If work needs to be done off hours, it must be coordinated with the COR.

b) There will be no unscheduled work during Federal Holidays.

VHA Supplemental Contract Requirements for Combatting COVID-19

1. Contractor employees who work in or travel to VHA locations must comply with the following:

1. Documentation requirements:

0. If fully vaccinated, contractors shall show proof of vaccination.

0. NOTE: Acceptable proof of vaccination includes a signed record of immunization from a health care provider or pharmacy, a copy of the COVID-19 Vaccination Record Card (CDC Form MLS-319813_r, published on September 3, 2020), or a copy of medical records documenting the vaccination.

0. If unvaccinated, contractors shall show negative COVID-19 test results dated within three calendar days prior to desired entry date. Test must be approved by the Food and Drug Administration (FDA) for emergency use or full approval. This includes tests available by a doctor’s order or an FDA approved over-the-counter test that includes an affiliated telehealth service.

0. Documentation cited in this section shall be digitally or physically maintained on each contractor employee while in a VA facility and is subject to inspection prior to entry to VA facilities and after entry for spot inspections by Contracting Officer Representatives (CORs) or other hospital personnel.

0. Documentation will not be collected by the VA; contractors shall, at all times, adhere to and ensure compliance with federal laws designed to protect contractor employee health information and personally identifiable information.

1. Contractor employees are subject to daily screening for COVID-19 and may be denied entry to VA facilities if they fail to pass screening protocols. As part of the screening process contractors may be asked screening questions found on the COVID-19 Screening Tool. Check regularly for updates.

1. Contractor employees who work away from VA locations, but who will have direct contact with VA patients shall self-screen utilizing the COVID-19 Screening Tool, in advance, each day that they will have direct patient contact and in accordance with their person or persons who coordinate COVID-19 workplace safety efforts at covered contractor workplaces. Contractors shall, at all times, adhere to and ensure compliance with federal laws designed to protect contractor employee health information and personally identifiable information.

1. Contractor must immediately notify their COR or Contracting Officer if contract performance is jeopardized due to contractor employees being denied entry into VA Facilities.

1. For indefinite delivery contracts: Contractor agrees to comply with VHA Supplemental Contract Requirements for any task or delivery orders issued prior to this modification when performance has already commenced.

File details come from the government source that posted it. Updated .