This document outlines the salient characteristics for a high temperature gel permeation chromatography system sought under a Department of the Air Force solicitation. The system must be able to operate between 40-220 degrees Celsius, with an autosampler capable of injecting 10-500 microliters and holding 24 or more samples in 2-10mL vials. The dual, independent pumps must precisely deliver flows from 0.1-2.0mL/min and withstand pressures up to 15MPa while temperature controlled between 40-220 degrees Celsius. Additional requirements include a 7.8mm ID x 30cm oven, RI detector with viscometer capability, software for data analysis and report generation, installation, training, and a one-year warranty.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Combined Synopsis Solicitation FA700023Q0072.pdf | ||
| Attachment 3 - FA700023Q0072 Provisions and Clauses.pdf | ||
| Attachment 2 - Buy American Certificate.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
The HT GPC should meet or exceed the following technical specifications when evaluated as described for each value:
Operating Temperature Range
40 ⁰C up to 220 ⁰C
Solvent Reservoir
Capacity: at least 4 L
Temperature: maintained at 40 ⁰C
Autosampler
Injection volume: 10 to 500 mL
Number of samples: 24 or more
Vial size: 2-10 mL injection vials
Temperature: must be able to heat in the range of 40 ⁰C up to 220 ⁰C
Pump
Type: Dual, independent, and temperature controlled (40 ⁰C up to 220 ⁰C)
Max pressure: 15 MPa
Flow Rate: 0.1 to 2.0 mL/min
Precision: +/- 0.2%
Accuracy: +/- 3%
Oven
Capacity: 7.8 mm ID x 30 cm or smaller
Temperature range: 40 ⁰C up to 220 ⁰C
Detector
Type: RI dual flow with a tungsten light source, must be able to add a viscometer detector after initial purchase
Drift: 3 x 10-7 RIU/h
Noise: 1.5 x10-7 RIU/h
Volume: 10 mL
Additional Features/Requirements
All software and hardware (desktop, monitor, printer, etc.) required for data analysis must be included in the quotation. The data file format should easily allow sharing/transfer of data files as individual electronic documents, which are readable by the same data analysis package. The data analysis program should also include a .pdf generator, for the efficient export of analyzed plots.
The quotation must include an on-site installation and training.
Instrument must come with at least 1-year warranty, parts, and labor included, from date of installation.