About this file

This document is an asset inventory list for a South Carolina state and local contract opportunity for rodding and eddy current testing services. The file contains a comprehensive catalog of chiller units distributed across multiple university and medical facility buildings, organized by building number and asset identification codes. The inventory lists 71 chiller units across various locations, including both helical rotary screw, centrifugal, and air-cooled configurations with tonnage capacities ranging from 8 to 2,400 tons. The chillers are primarily manufactured by Trane, York, Daikin, Carrier, and Filtrine, with refrigerants including R-134A, R-123, R-22, R-11, R-410A, and R-507. Each unit is documented with specific model numbers, serial numbers, and operational specifications to facilitate the rodding and eddy current testing services.

The asset inventory identifies equipment requiring inspection and maintenance across university (UNIV) and medical facility (MUHA) locations. The documentation includes detailed manufacturer specifications and serial number tracking, enabling vendors to provide targeted testing and maintenance services for the chiller system components. The variety of chiller types and refrigerant systems represented in the inventory indicates a diverse and aging mechanical infrastructure requiring specialized diagnostic testing to assess equipment condition, identify potential failures, and ensure continued operational reliability across multiple institutional facilities.

View the file

Other files for this state and local contract opportunity

Other files attached to RFQ RODDING AND EDDY CURRENT TESTING, newest first.
File Type Posted
RFQ.pdf PDF
NO AWARD.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNIV

QTYBLDGASSET IDDESCRIPTIONCHILLER#MFGMODEL#SERIAL#TONNAGETYPEREFRG
1106106-04-2895CHILLER #1 - HELICAL ROTARY SCREW/WATER COOLED. (R-134A 300T)1TRANERTHC1C2F0H0G1L3G1LFU03A08241300WC134A
1106106-04-2896CHILLER #2 - HELICAL ROTARY SCREW/WATER COOLED. (R-134A 300T)2TRANERTHC1C2F0H0G1L3G1LFU03A08240300WC134A
1106106-04-100CHILLER #3 - CENTRIFUGAL (R-11 710T)3TRANECVHE-0710-AH-ARB247L85M33287710WC11
1112112-02-2648CHILLER #1 - SCREW/AIR (R-134A 213T)1YORKYVAA0213ARV46BAVS11531H42961029213AC134A
1148148-39213CHILLER #11TRANERTAF310EU18F00747300AC134A
1197197-02-106CHILLER #1 - SCREW/AIR (R-22 125T) - "ADSIL COATED COILS"1YORKYLAA010011552K12058739100AC410A
1334334-CH-01AIR COOLED CHILLER CH-011YORKYVAA0213ARV46BAVNX82012M27857524190AC134A
1515515-CH-01AIR-COOLED SCREW CHILLER CH-01 - R134A - 228 TONS - MFG. DATE 1-22-171DAIKINAWV016AJJNNNN00STNU170600091228AC134A
1520520-02-100CHILLER #1 - CENTRIFUGAL (R-123 1470T)1TRANECVHF1470L03F054391470WC123
1520520-04-186CHILLER #2 - CENTRIFUGAL2TRANECVHF1300L09L026631300WC123
1520520-CH-03CHILLER CH-033TRANECVHF1300L20G025451300WC514A
1520520-04-188CHILLER #4 - CENTRIGUAL - WATER-COOLED4TRANECVHF1300L09M028991300WC123
1520520-04-189CHILLER #5 - CENTRIFUGAL - WATER-COOLED5TRANECVHF1300L09L026511300WC123
1525525-04-CH1CHILLER #1 - CENTRIFUGAL WATER COOLED (R-134A 600T)1YORKYKEMEKP8-CTFSBTM-831440600WC134A
1525525-04-CH2CHILLER #1 - CENTRIFUGAL WATER COOLED (R-134A 600T)2YORKYKEMEKP8-CTFSBTM-834250600WC134A
1600600-04-CH1CHILLER #1 - CENTRIFUGAL (R-134A 500T)1YORKYKFDFQQ7-ENGSMAM-835500500WC134A
1600600-04-CH2CHILLER #2 - CENTRIFUGAL (R-134A 500T)2YORKYKFDFQQ7-ENGSMAM-835680500WC134A
1600600-04-521CHILLER #3 - SCREW/WAT (R-134A 560T)3CARRIER23XRV5750410Q19521560WC134A
1650650-CH-01CHILLER1CARRIER19XR1420Q27944600WC
1750750-CH-1CHILLER - CH-11YORKYMC2-S1231AASSGJM-811900400WC134A
1750750-04-4874CHILLER - CH-33YORKYVAA0183ABV46BAVS11531A53439736183AC134A
1770770-02-503CHILLER #1 - CENTRIFUGAL (R-123 - 1280T)1TRANECVHF128GA2K0LDY290EJ7DEFBC0000L04K046491280WC123
1770770-02-504CHILLER #2 - CENTRIFUGAL (R-123 1280T)2TRANECVHF128GA2K0LDY290EJ7DEFBC0000L04K047261280WC123
1770770-CH-01CHILLER #13TRANERTAC200U19A02469200AC134A
1770770-CH-02CHILLER #24TRANERTAC200U19A02468200AC134A
1770770-CH-03CHILLER #35TRANERTAC200U19A02470200AC134A
1850850-04-15CHILLER #1 - CENTRIFUGAL, R-123 380T1YORKYTG3HLELGNGHFCM000159380WC123
1850850-CH-2CHILLER #22YORKM2C-218FAC11551N65855303400WC134A
1925925-CH-01CHILLER #1 - CENTRIFIGUL - WATER-COOLED1TRANECVHF760L21E01517760WC514A
1925925-02-136CHILLER #2 - CENTRIFUGAL (R-123 650T)2TRANECVHF-650-GA2E0ACTL03K07247650WC123
1925925-02-135CHILLER #3 - CENTRIFUGAL (R-123 650T)3TRANECVHF650L03K07245650WC123
1952952-CH-01CHILLER #1 - SCREW TYPE - AIR-COOLED1TRANERTAC2004U20K07655200AC134A
1952952-CH-02CHILLER #2 - SCREW TYPE - AIR-COOLED2TRANERTAC2004U20K07656200AC134A
1975975-04-222CHILLER #1 - SCREW/AIR (R-410A 190T)1DAIKINAGZ190DHHNN-ER10STNU131100051190AC410A
1925925-CHILL-09CHILLER 09 - SERVES AHU-09 (CHEMO PHARMACY)1YORKYCAL0022EE46XEBBTX11551G722997018.7AC410A
35

MUHA

QTYBLDGASSET IDDESCRIPTIONCHILLER#MFGMODEL#SERIAL#TONNAGETYPEREFRG
1300300-0611CHILLER 01 - CENTRIFUGAL WATER COOLED1TRANECVHF091GAU003L96K07976910WC123
1300300-0613CHILLER 02 - CENTRIFUGAL WATER COOLED2TRANECVHF091GAU003L96K07977910WC123
1300300-0615CHILLER 03 - CENTRIFUGAL WATER COOLED3TRANECVHF091GA1A03L98J05543910WC123
1300300-0617CHILLER 04 - CENTRIFUGAL WATER COOLED4TRANECVHF091GAU003L96K08077910WC123
1300300-0252CHILLER 05 - GLYCOL AIR COOLED Serves the OR's in CH5YORKYVAA0215CRV2CAMO19534215AC134A
1300300-0245CHILLER 06 - GLYCOL AIR COOLED Serves the OR's in CH6YORKYVAA0215CRV2CAMO19533215AC134A
1*300300-45779DX AIR COOLED WATER CHILLER - UNIT USED TO COOL GAMMA KNIFE1FILTRINEPCP-750S-98A-WP0174/208AC
1*300300-45780DX AIR COOLED WATER CHILLER - UNIT USED TO COOL GAMMA KNIFE2FILTRINEPCP-750G-96A-WP0183/208AC
1*320320-1019CHILLER 01 - GLYCOL HERMETIC AIR COOLED1FILTRINEPEP6000660ARL7466310660AC507
1*320320-1018CHILLER 02 - GLYCOL HERMETIC AIR COOLED2FILTRINEPEP6000660ARL7466110660AC507
1325325-0161CHILLER #1 - CENTRIFUGAL WATER COOLED1TRANECVHE147NA2MOFL05C013881470WC123
1325325-0160CHILLER #2 - CENTRIFUGAL WATER COOLED2TRANECVHE148NA2MOFL05C0138791470WC123
1325325-0159CHILLER #3 - CENTRIFUGAL WATER COOLED3TRANECVHE147NA2ROFL05J041001470WC123
1325325-43750CHILLER CH-05 - CENTRIFUGAL WATER COOLED5YORKYKS3S4K-DJGSSDEM7965402400WC134A
1500500-04-103CHILLER #6 - SCREW/WAT. (R-22 300T) - SERVES ANIMAL AREA6TRANERTHB300FMF00LWP0M0UNN3LF2LFV0QU0U98B07677300WC22
1580580-0043CHILLER #1 - CENTRIFUGAL WATER COOLED1TRANECVHF058FA2L06H03755580WC123
1580580-0044CHILLER #2 - CENTRIFUGAL WATER COOLED2TRANECVHE050GA2L99D01666M500WC123
1580580-0035CHILLER #3 - ROTARY WATER COOLED - Serves OR on EMG Power. Can isolate to provide Chill Water just to the OR Air Handler3TRANERTHC1B2FOU01E09812150WC22
1580580-0188CHILLER #44TRANECVHF049GAL16D02309485WC123
1900900-0810CHILLER #1 - CENTRIFUGAL WATER COOLED1TRANECVHF128GA1UO3L01E084721300WC123
1900900-0811CHILLER #2 - CENTRIFUGAL WATER COOLED2TRANECVHF130FA3XOPL09K020171300WC123
21

File details come from the government source that posted it. Updated .