Atch 3 - B775 Site Plan Drawing.pdf

PDF 57 KB Posted

Attached to
Building 775 Complex Area Sustainment Services Federal contract opportunity
Solicitation number
FA445222Q0008
Issued by
Department of the Air Force Air Mobility Command

View the file

Other files for this federal contract opportunity

Other files attached to Building 775 Complex Area Sustainment Services, newest first.
File Type Posted
Amendment 02.pdf PDF
FA445222Q0008 - QnR.pdf PDF
Amendment 01.pdf PDF
Atch 1 - B775 Statement of Work (SOW) (Rev 5-4-22).pdf PDF
Combined Synopsis Solicitation-LOX Pad.pdf PDF
Atch 2 - B775 LOX Site Map.pdf PDF
Atch 1 - B775 Statement of Work (SOW).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

B775

B773

B777 conex’s to be moved by unit

LOX Tanks concrete pad areaconcrete pad area fence line

Existing shed type building to be removed by unit

Existing LOX Pad/Buildings/Conex Containers and Shed Building

B775

B773

B777 new cmu walls

LOX Tanks existing concrete pad area existing concrete pad area

Existing fence line

New Fence line

New CMU walls: Number 1 walls to run on the inside of steel columns from rear to front of structure; Number 2 wall to run along the back of structure and connect to the number wall;

Number 3 wall to connect to rear wall run to line up with end of side walls and to be in center of the number 1 walls.

Relocate existing fence approximately 5 feet from existing location to accommodate new concrete pad. Attach the new fence line into the existing fence.

25 feet

25 feet

New concrete pads areas

70 feet

New LOX Pads/New Walls and Existing Buildings/Structures

Expand the LOX storage tank concrete pad adjacent to B775 to meet the concrete pad 25 feet requirement to keep flammable material from a pressurized oxygen source. The areas requiring pad expansion are located directly behind the LOX tanks excluding the existing concrete pad currently supporting the 2 LOX tanks.

Relocate the existing fence approximately 5 feet away from the existing location to accommodate the new pad.

Clear the grounds of rocks an prepare (level) the grounds for the concrete pad.

Construct a squared U-shaped structure wall barrier. Construct a rear wall inside of the two rear steel columns (as you face the structure from B775). Construct two side walls, from the rear wall towards the front two steel columns. Construct a third wall in the center of the squared U-shape structure that runs from the rear wall and lines up with the end of the two side walls. These walls are to be 5”-0” in height, reinforced vertically, and anchored into the concrete slab.

25 feet

Verify the existing concrete pad area in front of the LOX Tanks comply with the 25’ requirement