Appendix A Lab Report - USDA Building 89.pdf
PDF 1 MB Posted
- Attached to
- Mold Remediation Services BLDG 89 Federal contract opportunity
- Solicitation number
- 12405B24Q0372
About this file
This document is a combined synopsis/solicitation for a Request for Quote (RFQ) for mold remediation services at USDA Building 89 in Miami, Florida. The Department of Agriculture Agricultural Research Service is seeking a contractor to provide these services. The solicitation number is 12405B24Q0372 and the associated NAICS code is 562910 Environmental Remediation Services.
The government anticipates awarding a firm fixed price contract for the mold remediation work. Offerors must provide a price breakdown, technical specifications, and past performance information. A site visit is scheduled for July 24, 2024. Quotes are due by July 30, 2024 at 4:00 PM CST. The basis for award will be the lowest price technically acceptable offer. The contract will include standard FAR and AGAR clauses for commercial items. All contractors must be registered in the System for Award Management (SAM) to be eligible for award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PWS B89 Mold Remediation Miami FL.docx | DOCX document | |
| Wage Rates.pdf | ||
| Appendix B Miami B89 MOLD ASSESSMENT REPORT 13601 Old Cutler Rd.pdf | ||
| Service Provisions 1135441.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ECO AIR MOLD ASSESSOR
2846 LINCOLN ST
HOLLYWOOD, FL 33020
Certificate of Mold Analysis
Prepared for: ECO AIR MOLD ASSESSOR
Phone Number: (954) 991-9778
Fax Number:
Project Name: SEA SUBTROPICAL HORTICULTURE RESEARCH
Test Location: 13601 OLD CUTLER ROAD
MIAMI, FL 33158
Report Number: 1745090
Received Date: May 31, 2024
Report Date: May 31, 2024
Diana Sauri, Laboratory Director or other approved signatory
Currently there are no Federal regulations for evaluating potential health effects of fungal contamination and remediation. This information is subject to change as more information regarding fungal contaminants becomes available. For more information visit http://www.epa.gov/mold or www.nyc.gov/html/doh/html/epi/mold.shtml. This document was designed to follow currently known industry guidelines for the interpretation of microbial sampling, analysis, and remediation. Since interpretation of mold analysis reports is a scientific work in progress, it may as such be changed at any time without notice. The client is solely responsible for the use or interpretation. PRO-LAB/SSPTM Inc.
makes no express or implied warranties as to health of a property from only the samples sent to their laboratory for analysis. The Client is hereby notified that due to the subjective nature of fungal analysis and the mold growth process, laboratory samples can and do change over time relative to the originally sampled material. PRO-LAB/SSPTM Inc. reserves the right to properly dispose of all samples after the testing of such samples are sufficiently completed or after a 7 day period, whichever is greater.
For more information please contact PRO-LAB at (954) 384-4446 or email info@prolabinc.com
Prepared for : ECO AIR MOLD ASSESSOR Test Address : SEA SUBTROPICAL HORTICULTURE RESEARCH
13601 OLD CUTLER ROAD
MIAMI, FL 33158
IDENTIFICATION
Raw
Count Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Alternaria
Cladosporium
Dicyma
Hyphae
Memnoniella
Nigrospora
Other Ascospores 4 53 50
Other Basidiospores
Penicillium/Aspergillus 8 110 100 4 53 50 8 110 100 4 53 100
Smuts, myxomycetes
Stachybotrys
Trichoderma
ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination
LOCATION 2ND FLOOR HALLWAY 201/202 202/203 212/213
COC / LINE # 1745090 - 1 1745090 - 2 1745090 - 3 1745090 - 4
SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15
VOLUME 75.00L 75.00L 75.00L 75.00L
SERIAL NUMBER Q2514843 Q2489886 Q2506506 Q2506511
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED
TOTAL SPORES 8 110 100 8 106 100 8 110 100 4 53 100
MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53
BACKGROUND DEBRIS Light Light Light Light
OBSERVATIONS & COMMENTS
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
NA = Not Applicable.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated with one or more of the types of mold/fungi identified in the analyzed sample.
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Count Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Alternaria
Cladosporium 4 53 50
Dicyma
Hyphae
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores 4 53 33
Penicillium/Aspergillus 4 53 100 4 53 50 8 110 67 12 160 100
Smuts, myxomycetes
ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination
LOCATION 217/218 232/233 215/216 211
COC / LINE # 1745090 - 5 1745090 - 6 1745090 - 7 1745090 - 8
SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15
VOLUME 75.00L 75.00L 75.00L 75.00L
SERIAL NUMBER Q2541145 Q2541298 Q2549626 Q2514838
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED
TOTAL SPORES 4 53 100 8 106 100 12 163 100 12 160 100
MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53
BACKGROUND DEBRIS Light Light Light Light
OBSERVATIONS & COMMENTS
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Count Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Alternaria
Cladosporium 8 110 50 20 270 23
Dicyma
Hyphae
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores 4 53 100
Penicillium/Aspergillus 8 110 50 68 910 77 12 160 100
Smuts, myxomycetes
ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination
LOCATION 205 124/125 A/C UNIT ROOM 1 A/C UNIT ROOM 2
COC / LINE # 1745090 - 9 1745090 - 10 1745090 - 11 1745090 - 12
SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15
VOLUME 75.00L 75.00L 75.00L 75.00L
SERIAL NUMBER Q2489844 Q2549489 Q2549093 Q2524483
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED
TOTAL SPORES 4 53 100 16 220 100 88 1,180 100 12 160 100
MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53
BACKGROUND DEBRIS Light Light Light Light
OBSERVATIONS & COMMENTS
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Count Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Alternaria 12 160 4
Cladosporium 112 1,500 41
Dicyma
Hyphae 8 110 3
Memnoniella
Nigrospora 8 110 3
Other Ascospores 8 110 100 36 480 13
Other Basidiospores
Penicillium/Aspergillus 8 110 100 80 1,100 30
Smuts, myxomycetes 16 210 6
Stachybotrys 4 53 100
ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination
LOCATION LIBRARY 1ST FLOOR 126/127 OUTSIDE BASELINE MAIN ENTRANCE
COC / LINE # 1745090 - 13 1745090 - 14 1745090 - 15 1745090 - 16
SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15
VOLUME 75.00L 75.00L 75.00L 75.00L
SERIAL NUMBER Q2532818 Q2541146 Q2489831 Q2549487
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION NOT ELEVATED NOT ELEVATED CONTROL ELEVATED
TOTAL SPORES 8 110 100 8 110 100 272 3,670 100 4 53 100
MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53
BACKGROUND DEBRIS Light Light Moderate Light
OBSERVATIONS & COMMENTS
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Count Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Raw Count
Spores per m3
Percent of Total
Alternaria
Cladosporium
Dicyma
Hyphae
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus 12 160 100 8 110 100 8 110 100
Smuts, myxomycetes
ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination
LOCATION 1ST FLOOR HALLWAY ADMIN OFFICE HALLWAY 113 CONFERENCE ROOM
COC / LINE # 1745090 - 17 1745090 - 18 1745090 - 19 1745090 - 20
SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15
VOLUME 75.00L 75.00L 75.00L 75.00L
SERIAL NUMBER Q2532960 Q2549483 Q2524477 Q2549488
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED
TOTAL SPORES 12 160 100 8 110 100 8 110 100
MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53
BACKGROUND DEBRIS Light Light Light
OBSERVATIONS & COMMENTS No Fungi Detected.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Mold
Present Mold
Present Mold
Present Mold
Present
Alternaria
Cladosporium
Dicyma
Hyphae X X X X
Memnoniella X
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus X X X
Smuts, myxomycetes
Stachybotrys X X
ANALYSIS METHOD
6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination
LOCATION 201 PAINT BELLOW WINDOW
232 BACK WALL DRYWALL
WINDOW 218 BACKROOM DRYWALL 213 DOOR PAINT
COC / LINE # 1745090 - 21 1745090 - 22 1745090 - 23 1745090 - 24
SAMPLE TYPE BULK BULK BULK BULK
VOLUME NA NA NA NA
SERIAL NUMBER B1 B2 B3 B4
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION UNUSUAL UNUSUAL UNUSUAL UNUSUAL
TOTAL SPORES NA NA NA NA
MINIMUM DETECTION LIMIT* NA NA NA NA
BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable
OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. Presence of growth observed. Presence of growth observed.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Present Mold
Present Mold
Present Mold
Present
Alternaria
Cladosporium
Dicyma
Hyphae X X X X
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus X X X X
Smuts, myxomycetes
Stachybotrys X X
Trichoderma X
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination
LOCATION
213 DRYWALL UNDER
CABINET A/C ROOM PIPES
WOMENS LOCKER RM
CEILING SINK CABINET RM 126
COC / LINE # 1745090 - 25 1745090 - 26 1745090 - 27 1745090 - 28
SAMPLE TYPE BULK SWAB SWAB SWAB
VOLUME NA NA NA NA
SERIAL NUMBER B5 SW14 SW13 SW12
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION UNUSUAL UNUSUAL UNUSUAL UNUSUAL
TOTAL SPORES NA NA NA NA
MINIMUM DETECTION LIMIT* NA NA NA NA
BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable
OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. Presence of growth observed. Presence of growth observed.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Present Mold
Present Mold
Present Mold
Present
Alternaria
Cladosporium
Dicyma
Hyphae X X
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus X X X
Smuts, myxomycetes
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination
LOCATION 126 A/C VENTS 133 DESK 213 A/C VENT 213 SINK CABINET
COC / LINE # 1745090 - 29 1745090 - 30 1745090 - 31 1745090 - 32
SAMPLE TYPE SWAB SWAB SWAB SWAB
VOLUME NA NA NA NA
SERIAL NUMBER SW11 SW10 SW9 SW8
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION UNUSUAL NORMAL NORMAL UNUSUAL
TOTAL SPORES NA NA NA NA
MINIMUM DETECTION LIMIT* NA NA NA NA
BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable
OBSERVATIONS & COMMENTS Presence of growth observed. No Fungi Detected. No presence of growth. Only normally settled spores observed.
Presence of growth observed.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Present Mold
Present Mold
Present Mold
Present
Alternaria
Cladosporium
Dicyma X
Hyphae X X X
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus X X X
Smuts, myxomycetes
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination
LOCATION 212 CABINETS 212 A/C VENTS 211 A/C VENTS 211 DRAWERS
COC / LINE # 1745090 - 33 1745090 - 34 1745090 - 35 1745090 - 36
SAMPLE TYPE SWAB SWAB SWAB SWAB
VOLUME NA NA NA NA
SERIAL NUMBER SW7 SW6 SW5 SW4
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION UNUSUAL NORMAL UNUSUAL UNUSUAL
TOTAL SPORES NA NA NA NA
MINIMUM DETECTION LIMIT* NA NA NA NA
BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable
OBSERVATIONS & COMMENTS Presence of growth observed. No presence of growth. Only normally settled spores observed.
Presence of growth observed. Presence of growth observed.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Present Mold
Present Mold
Present
Alternaria
Cladosporium X X
Dicyma
Hyphae X X
Memnoniella
Nigrospora
Other Ascospores
Other Basidiospores
Penicillium/Aspergillus X X X
Smuts, myxomycetes
Examination 6210 Surface and Bulk Direct
Examination 6210 Surface and Bulk Direct
Examination INTENTIONALLY BLANK
LOCATION 205 WINDOW AREA 202 DRAWERS 202 TABLE
COC / LINE # 1745090 - 37 1745090 - 38 1745090 - 39
SAMPLE TYPE SWAB SWAB SWAB
VOLUME NA NA NA
SERIAL NUMBER SW3 SW2 SW1
COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024
ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024
CONCLUSION UNUSUAL UNUSUAL NORMAL
TOTAL SPORES NA NA NA
MINIMUM DETECTION LIMIT* NA NA NA
BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable
OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. No presence of growth. Only normally settled spores observed.
Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.
* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.
Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.
Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.
CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).
ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.
NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.
UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated
NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.
Chain of Custody # 1745090
2Nd Floor Hallway
Outside Baseline
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Smuts, myxomycetes
Spores per cubic meter
201/202
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
202/203
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
212/213
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
217/218
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
232/233
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
215/216
1 10 100 1000 10000
Alternaria
Other Ascospores
Other Basidiospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
1 10 100 1000 10000
Alternaria
Other Ascospores
Other Basidiospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
124/125
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
A/C Unit Room 1
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
A/C Unit Room 2
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Library 1St Floor
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
126/127
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Main Entrance
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Smuts, myxomycetes
1St Floor Hallway
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Admin Office Hallway
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Conference Room
1 10 100 1000 10000
Alternaria
Other Ascospores
Cladosporium
Hyphae
Nigrospora
Penicillium/Aspergillus
Identification Outdoor Habitat Indoor Habitat Possible Allergic Potential Not an opinion or interpretation
Comments
Alternaria
One of the most commonly reported airborne spores worldwide. Often common in outdoor air. Usually not observed in large nubmers in outdoor air. Soil, dead or dying plants, foodstuffs, textiles
Wallboard paper backing, wood, other various cellulose-containing materials. Commonly found in settled dust and as normal settled spores on carpets, drapes, textiles, etc.
Common allergen. Type I allergies (hay fever and asthma); Type III hypersensitivty pneumonitis.
Common cause of extrinsic…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .