Appendix A Lab Report - USDA Building 89.pdf

PDF 1 MB Posted

Attached to
Mold Remediation Services BLDG 89 Federal contract opportunity
Solicitation number
12405B24Q0372
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery

About this file

This document is a combined synopsis/solicitation for a Request for Quote (RFQ) for mold remediation services at USDA Building 89 in Miami, Florida. The Department of Agriculture Agricultural Research Service is seeking a contractor to provide these services. The solicitation number is 12405B24Q0372 and the associated NAICS code is 562910 Environmental Remediation Services.

The government anticipates awarding a firm fixed price contract for the mold remediation work. Offerors must provide a price breakdown, technical specifications, and past performance information. A site visit is scheduled for July 24, 2024. Quotes are due by July 30, 2024 at 4:00 PM CST. The basis for award will be the lowest price technically acceptable offer. The contract will include standard FAR and AGAR clauses for commercial items. All contractors must be registered in the System for Award Management (SAM) to be eligible for award.

View the file

Other files for this federal contract opportunity

Other files attached to Mold Remediation Services BLDG 89, newest first.
File Type Posted
PWS B89 Mold Remediation Miami FL.docx DOCX document
Wage Rates.pdf PDF
Appendix B Miami B89 MOLD ASSESSMENT REPORT 13601 Old Cutler Rd.pdf PDF
Service Provisions 1135441.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ECO AIR MOLD ASSESSOR

2846 LINCOLN ST

HOLLYWOOD, FL 33020

Certificate of Mold Analysis

Prepared for: ECO AIR MOLD ASSESSOR

Phone Number: (954) 991-9778

Fax Number:

Project Name: SEA SUBTROPICAL HORTICULTURE RESEARCH

Test Location: 13601 OLD CUTLER ROAD

MIAMI, FL 33158

Report Number: 1745090

Received Date: May 31, 2024

Report Date: May 31, 2024

Diana Sauri, Laboratory Director or other approved signatory

Currently there are no Federal regulations for evaluating potential health effects of fungal contamination and remediation. This information is subject to change as more information regarding fungal contaminants becomes available. For more information visit http://www.epa.gov/mold or www.nyc.gov/html/doh/html/epi/mold.shtml. This document was designed to follow currently known industry guidelines for the interpretation of microbial sampling, analysis, and remediation. Since interpretation of mold analysis reports is a scientific work in progress, it may as such be changed at any time without notice. The client is solely responsible for the use or interpretation. PRO-LAB/SSPTM Inc.

makes no express or implied warranties as to health of a property from only the samples sent to their laboratory for analysis. The Client is hereby notified that due to the subjective nature of fungal analysis and the mold growth process, laboratory samples can and do change over time relative to the originally sampled material. PRO-LAB/SSPTM Inc. reserves the right to properly dispose of all samples after the testing of such samples are sufficiently completed or after a 7 day period, whichever is greater.

For more information please contact PRO-LAB at (954) 384-4446 or email info@prolabinc.com

Prepared for : ECO AIR MOLD ASSESSOR Test Address : SEA SUBTROPICAL HORTICULTURE RESEARCH

13601 OLD CUTLER ROAD

MIAMI, FL 33158

IDENTIFICATION

Raw

Count Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Alternaria

Cladosporium

Dicyma

Hyphae

Memnoniella

Nigrospora

Other Ascospores 4 53 50

Other Basidiospores

Penicillium/Aspergillus 8 110 100 4 53 50 8 110 100 4 53 100

Smuts, myxomycetes

Stachybotrys

Trichoderma

ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination

LOCATION 2ND FLOOR HALLWAY 201/202 202/203 212/213

COC / LINE # 1745090 - 1 1745090 - 2 1745090 - 3 1745090 - 4

SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15

VOLUME 75.00L 75.00L 75.00L 75.00L

SERIAL NUMBER Q2514843 Q2489886 Q2506506 Q2506511

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED

TOTAL SPORES 8 110 100 8 106 100 8 110 100 4 53 100

MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53

BACKGROUND DEBRIS Light Light Light Light

OBSERVATIONS & COMMENTS

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

NA = Not Applicable.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated with one or more of the types of mold/fungi identified in the analyzed sample.

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Count Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Alternaria

Cladosporium 4 53 50

Dicyma

Hyphae

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores 4 53 33

Penicillium/Aspergillus 4 53 100 4 53 50 8 110 67 12 160 100

Smuts, myxomycetes

ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination

LOCATION 217/218 232/233 215/216 211

COC / LINE # 1745090 - 5 1745090 - 6 1745090 - 7 1745090 - 8

SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15

VOLUME 75.00L 75.00L 75.00L 75.00L

SERIAL NUMBER Q2541145 Q2541298 Q2549626 Q2514838

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED

TOTAL SPORES 4 53 100 8 106 100 12 163 100 12 160 100

MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53

BACKGROUND DEBRIS Light Light Light Light

OBSERVATIONS & COMMENTS

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Count Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Alternaria

Cladosporium 8 110 50 20 270 23

Dicyma

Hyphae

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores 4 53 100

Penicillium/Aspergillus 8 110 50 68 910 77 12 160 100

Smuts, myxomycetes

ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination

LOCATION 205 124/125 A/C UNIT ROOM 1 A/C UNIT ROOM 2

COC / LINE # 1745090 - 9 1745090 - 10 1745090 - 11 1745090 - 12

SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15

VOLUME 75.00L 75.00L 75.00L 75.00L

SERIAL NUMBER Q2489844 Q2549489 Q2549093 Q2524483

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED

TOTAL SPORES 4 53 100 16 220 100 88 1,180 100 12 160 100

MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53

BACKGROUND DEBRIS Light Light Light Light

OBSERVATIONS & COMMENTS

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Count Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Alternaria 12 160 4

Cladosporium 112 1,500 41

Dicyma

Hyphae 8 110 3

Memnoniella

Nigrospora 8 110 3

Other Ascospores 8 110 100 36 480 13

Other Basidiospores

Penicillium/Aspergillus 8 110 100 80 1,100 30

Smuts, myxomycetes 16 210 6

Stachybotrys 4 53 100

ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination

LOCATION LIBRARY 1ST FLOOR 126/127 OUTSIDE BASELINE MAIN ENTRANCE

COC / LINE # 1745090 - 13 1745090 - 14 1745090 - 15 1745090 - 16

SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15

VOLUME 75.00L 75.00L 75.00L 75.00L

SERIAL NUMBER Q2532818 Q2541146 Q2489831 Q2549487

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION NOT ELEVATED NOT ELEVATED CONTROL ELEVATED

TOTAL SPORES 8 110 100 8 110 100 272 3,670 100 4 53 100

MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53

BACKGROUND DEBRIS Light Light Moderate Light

OBSERVATIONS & COMMENTS

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Count Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Raw Count

Spores per m3

Percent of Total

Alternaria

Cladosporium

Dicyma

Hyphae

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus 12 160 100 8 110 100 8 110 100

Smuts, myxomycetes

ANALYSIS METHOD 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination 6110 Air Direct Examination

LOCATION 1ST FLOOR HALLWAY ADMIN OFFICE HALLWAY 113 CONFERENCE ROOM

COC / LINE # 1745090 - 17 1745090 - 18 1745090 - 19 1745090 - 20

SAMPLE TYPE PRO-15 PRO-15 PRO-15 PRO-15

VOLUME 75.00L 75.00L 75.00L 75.00L

SERIAL NUMBER Q2532960 Q2549483 Q2524477 Q2549488

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION NOT ELEVATED NOT ELEVATED NOT ELEVATED NOT ELEVATED

TOTAL SPORES 12 160 100 8 110 100 8 110 100

MINIMUM DETECTION LIMIT* 4 53 4 53 4 53 4 53

BACKGROUND DEBRIS Light Light Light

OBSERVATIONS & COMMENTS No Fungi Detected.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Mold

Present Mold

Present Mold

Present Mold

Present

Alternaria

Cladosporium

Dicyma

Hyphae X X X X

Memnoniella X

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus X X X

Smuts, myxomycetes

Stachybotrys X X

ANALYSIS METHOD

6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination

LOCATION 201 PAINT BELLOW WINDOW

232 BACK WALL DRYWALL

WINDOW 218 BACKROOM DRYWALL 213 DOOR PAINT

COC / LINE # 1745090 - 21 1745090 - 22 1745090 - 23 1745090 - 24

SAMPLE TYPE BULK BULK BULK BULK

VOLUME NA NA NA NA

SERIAL NUMBER B1 B2 B3 B4

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION UNUSUAL UNUSUAL UNUSUAL UNUSUAL

TOTAL SPORES NA NA NA NA

MINIMUM DETECTION LIMIT* NA NA NA NA

BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable

OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. Presence of growth observed. Presence of growth observed.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Present Mold

Present Mold

Present Mold

Present

Alternaria

Cladosporium

Dicyma

Hyphae X X X X

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus X X X X

Smuts, myxomycetes

Stachybotrys X X

Trichoderma X

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination

LOCATION

213 DRYWALL UNDER

CABINET A/C ROOM PIPES

WOMENS LOCKER RM

CEILING SINK CABINET RM 126

COC / LINE # 1745090 - 25 1745090 - 26 1745090 - 27 1745090 - 28

SAMPLE TYPE BULK SWAB SWAB SWAB

VOLUME NA NA NA NA

SERIAL NUMBER B5 SW14 SW13 SW12

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION UNUSUAL UNUSUAL UNUSUAL UNUSUAL

TOTAL SPORES NA NA NA NA

MINIMUM DETECTION LIMIT* NA NA NA NA

BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable

OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. Presence of growth observed. Presence of growth observed.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Present Mold

Present Mold

Present Mold

Present

Alternaria

Cladosporium

Dicyma

Hyphae X X

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus X X X

Smuts, myxomycetes

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination

LOCATION 126 A/C VENTS 133 DESK 213 A/C VENT 213 SINK CABINET

COC / LINE # 1745090 - 29 1745090 - 30 1745090 - 31 1745090 - 32

SAMPLE TYPE SWAB SWAB SWAB SWAB

VOLUME NA NA NA NA

SERIAL NUMBER SW11 SW10 SW9 SW8

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION UNUSUAL NORMAL NORMAL UNUSUAL

TOTAL SPORES NA NA NA NA

MINIMUM DETECTION LIMIT* NA NA NA NA

BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable

OBSERVATIONS & COMMENTS Presence of growth observed. No Fungi Detected. No presence of growth. Only normally settled spores observed.

Presence of growth observed.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Present Mold

Present Mold

Present Mold

Present

Alternaria

Cladosporium

Dicyma X

Hyphae X X X

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus X X X

Smuts, myxomycetes

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination

LOCATION 212 CABINETS 212 A/C VENTS 211 A/C VENTS 211 DRAWERS

COC / LINE # 1745090 - 33 1745090 - 34 1745090 - 35 1745090 - 36

SAMPLE TYPE SWAB SWAB SWAB SWAB

VOLUME NA NA NA NA

SERIAL NUMBER SW7 SW6 SW5 SW4

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION UNUSUAL NORMAL UNUSUAL UNUSUAL

TOTAL SPORES NA NA NA NA

MINIMUM DETECTION LIMIT* NA NA NA NA

BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable Not Applicable

OBSERVATIONS & COMMENTS Presence of growth observed. No presence of growth. Only normally settled spores observed.

Presence of growth observed. Presence of growth observed.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Present Mold

Present Mold

Present

Alternaria

Cladosporium X X

Dicyma

Hyphae X X

Memnoniella

Nigrospora

Other Ascospores

Other Basidiospores

Penicillium/Aspergillus X X X

Smuts, myxomycetes

Examination 6210 Surface and Bulk Direct

Examination 6210 Surface and Bulk Direct

Examination INTENTIONALLY BLANK

LOCATION 205 WINDOW AREA 202 DRAWERS 202 TABLE

COC / LINE # 1745090 - 37 1745090 - 38 1745090 - 39

SAMPLE TYPE SWAB SWAB SWAB

VOLUME NA NA NA

SERIAL NUMBER SW3 SW2 SW1

COLLECTION DATE May 29, 2024 May 29, 2024 May 29, 2024

ANALYSIS DATE May 31, 2024 May 31, 2024 May 31, 2024

CONCLUSION UNUSUAL UNUSUAL NORMAL

TOTAL SPORES NA NA NA

MINIMUM DETECTION LIMIT* NA NA NA

BACKGROUND DEBRIS Not Applicable Not Applicable Not Applicable

OBSERVATIONS & COMMENTS Presence of growth observed. Presence of growth observed. No presence of growth. Only normally settled spores observed.

Background debris qualitatively estimates the amount of particles that are not pollen or spores and directly affects the accuracy of the spore counts. The categories of Light, Moderate, Heavy and Too Heavy for Accurate Count, are used to indicate the amount of deposited debris. Light (None to up to 25% obstruction); Medium (26% to up to 75% obstruction); Heavy (76% to up to 90% obstruction); Too Heavy (Greater than 90% obstruction). Increasing amounts of debris will obscure small spores and can prevent spores from impacting onto the slide. The actual number of spores present in the sample is likely higher than reported if the debris estimate is ‘Heavy’ or ‘Too Heavy for Accurate Count’. All calculations are rounded to two significant figures and therefore, the total percentage of spore numbers may not equal 100%. The effect of the results relate only to the items tested. The methods used in this analysis have been validated and is fit for the intended use. R “version” indicated after the lab ID# indicates a sample with amended data. PRO-LAB/SSPTM Inc. does not perform any sample collection. The information is supplied by the customer and can affect the validity of results. The results apply to the sample as received.

* Minimum Detection Limit. Based on the volume of air sampled, this is the lowest number of spores that can be detected and is an estimate of the lowest concentration of spores that can be read in the sample.

Spores that were observed from the samples submitted are listed on this report. If a spore is not listed on this report it was not observed in the samples submitted.

Interpretation Guidelines: A determination is added to the report to help users interpret the mold analysis results. A mold report is only one aspect of an indoor air quality investigation. The most important aspect of mold growth in a living space is the availability of water. Without a source of water, mold generally will not become a problem in buildings. These determinations are in no way meant to imply any health outcomes or financial decisions based solely on this report. For questions relating to medical conditions you should consult an occupational or environmental health physician or professional.

CONTROL is a baseline sample showing what the spore count and diversity is at the time of sampling. The control sample(s) is usually collected outside of the structure being tested and used to determine if this sample(s) is similar in diversity and abundance to the inside sample(s).

ELEVATED means that the amount and/or diversity of spores, as compared to the control sample(s), and other samples in our database, are higher than expected. This can indicate that fungi have grown because of a water leak or water intrusion. Fungi that are considered to be indicators of water damage include, but are not limited to: Chaetomium, Fusarium, Memnoniella, Stachybotrys, Scopulariopsis, Ulocladium.

NOT ELEVATED means that the amount and/or the diversity of spores, as compared to the control sample and other samples in our database, are lower than expected and may indicate no problematic fungal growth.

UNUSUAL means that the presence of growth was observed in the analyzed sample. An abundance of spores are present, and/or growth structures including hyphae and/or fruiting bodies are present and associated

NORMAL means that no presence of growth was observed in the analyzed sample. If spores are recorded they are normally what is in the air and have settled on the surface(s) tested.

Chain of Custody # 1745090

2Nd Floor Hallway

Outside Baseline

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Smuts, myxomycetes

Spores per cubic meter

201/202

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

202/203

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

212/213

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

217/218

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

232/233

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

215/216

1 10 100 1000 10000

Alternaria

Other Ascospores

Other Basidiospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

1 10 100 1000 10000

Alternaria

Other Ascospores

Other Basidiospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

124/125

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

A/C Unit Room 1

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

A/C Unit Room 2

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Library 1St Floor

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

126/127

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Main Entrance

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Smuts, myxomycetes

1St Floor Hallway

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Admin Office Hallway

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Conference Room

1 10 100 1000 10000

Alternaria

Other Ascospores

Cladosporium

Hyphae

Nigrospora

Penicillium/Aspergillus

Identification Outdoor Habitat Indoor Habitat Possible Allergic Potential Not an opinion or interpretation

Comments

Alternaria

One of the most commonly reported airborne spores worldwide. Often common in outdoor air. Usually not observed in large nubmers in outdoor air. Soil, dead or dying plants, foodstuffs, textiles

Wallboard paper backing, wood, other various cellulose-containing materials. Commonly found in settled dust and as normal settled spores on carpets, drapes, textiles, etc.

Common allergen. Type I allergies (hay fever and asthma); Type III hypersensitivty pneumonitis.

Common cause of extrinsic…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .