Albert Creek Fence Project Material Specifications Final.doc
DOC document 52 KB Posted
- Attached to
- ALBERT CREEK FENCE Federal contract opportunity
- Solicitation number
- 140L6220Q0106
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Albert Creek Fence Project Work Data Sheet Final.docx | DOCX document | |
| Albert Creek Fence bid schedule.xlsx | XLSX spreadsheet | |
| Section 02826 Albert Creek Fence Project Drainage Crossings Final.doc | DOC document | |
| 01009 General Albert Creek Fence Project Final.docx | DOCX document | |
| Albert Creek Fence Project BLM Standard Panels and Gates Drawings.docx | DOCX document | |
| Section 02827 Albert Creek Fence Project Fence Removal Final.docx | DOCX document | |
| Albert Creek Fence SOW Final.docx | DOCX document | |
| Section 01505 Albert Creek Fence Project Mobilization and Demobilization Final.doc | DOC document | |
| Sol_140L6220Q0106.pdf | ||
| Section 02824 Albert Creek Fence Project Wire Fence and Gates Final.docx | DOCX document | |
| Albert Creek Fence Drawings 2020 Contract.pdf |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Material Specifications
A. Barbed Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together with 2‑point barbs of 14‑gauge wire spaced 4-inches apart. Wire and barbs shall be zinc‑coated steel, with a zinc coating of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbed wire shall conform to ASTM A 121.
B.
Barbless Wire: A strand of two 12‑1/2‑gauge galvanized wires twisted together. Wire shall be zinc‑coated steel wire of at least 0.3 oz/ft2 of coated surface area. The minimum breaking strength of each wire shall be 950 lb‑force. The barbless wire shall conform to ASTM A 121.
C.
Wood Stays: Straight, sound single-stem members. Shall be 42-inch long, 2-inch (milled) in diameter made from Ponderosa pine, or Lodgepole Pine. Peeled and CCA treated.
D.
Steel Fence Posts: ASTM A 702; painted green with white or silver tops "T" bar type, with a welded or riveted anchor plate. Furnish with clip‑type wire fasteners (punched tabs for fastening wires are not acceptable). Steel posts shall be manufactured from wrought, rail, or new billet steel, and shall have a minimum weight of 1.33 lb/ft. The anchor plates shall weigh a minimum of 0.67 pounds +5 percent, be a minimum of 18 square inches in area, and be 18-inches from the bottom of the post. The posts shall be 5.5-feet in length.
E.
Steel Frame Gate (16-Foot): 16-foot Steel Frame Gates as shown on BLM Standard Drawing for Steel Frame Gate.
F.
Wood Posts and Braces:
1.
Acceptable Wood Posts: Sound single-stem members. A slight bend in one plane is acceptable. Posts may be full stem members, sawed members of square cross section, or split members (western red cedar only). Nominal diameter for treated posts shall be 6-inches. The following species will be acceptable: Ponderosa pine, Lodgepole pine, fir, and tamarack. All treated posts shall be free of bark with ends cut square.
2.
Basis for Rejection: Posts are not acceptable when sweep causes a straight line joining the center of the top to the center of the butt to fall outside the body of the post, or at point 2-inches or more from the center of the post. Posts that are charred, twisted, rotted, or excessively bent are not acceptable. Seasoning checks, single or opposite each other with a sum total equal to or more than 1/2 the thickness of the post are not acceptable.
G. Wood Treatment Practices: General: The following treatments may be used. Treatment method shall be in accordance with AWPA C 1.
1. Chromate Copper Arsenic Method: chromate copper arsenate, waterborne preservative (conforming to Type B in AWPA 5) shall be applied. Minimum net retention of solid preservative shall be 0.4 pounds per cubic foot (gauge only) using the full-cell pressure treatment process.
2. Assay Report: The Supplier shall furnish an assay report, for all treated wood products, from an independent testing laboratory to the Contracting Officer. A minimum of five inch boring shall be taken from each bundle of 50 posts as samples for the assay report.
A written submittal for all materials shall be submitted for approval to Andy Skordas (askordas@blm.gov) Rawlins Wyoming BLM Field Office prior to shipping the products. Contact Andy Skordas with any questions 307-320-5714.
Albert Creek Fence
Material Specifications
File details come from the government source that posted it. Updated .