Alaska Sub Flooring Specs (AKS-AB846) - (Attachment 1).pdf
PDF 578 KB Posted
- Attached to
- DDXX Alaska Tents Federal contract opportunity
- Solicitation number
- SP330023Q0185
- Issued by
- Defense Logistics Agency Distribution
About this file
This document provides specifications for corrugated polypropylene sub flooring panels to be used under vinyl flooring in Alaska tents. The panels are pre-attached and accordion up for storage, fitting inside shelter base frames. Specifications include a tolerance gauge of 8mm, density of 1800 grams/sq meter (367 lbs/1000 sq ft), skin and flute thicknesses of 0.030" and 0.029" respectively, and performance factors such as a melting point of 3240F and notched Izod impact of 3 ft-lbs/in at 700F. The related federal contract opportunity is solicitation number SP330023Q0185 for DDXX Alaska Tents through the Defense Logistics Agency Distribution.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Tab C-6 RFQ SP3300-23-Q-0185 Amendment P00001.pdf | ||
| AK-SSS-CONT spec sheet - Attachment 4.pdf | ||
| AK-ULC spec sheet - Attachment 3.pdf | ||
| Tab C-6 RFQ SP3300-23-Q-0185.pdf | ||
| AKS-BA145 Spec Sheet - Attachment 2.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Proprietary and Confidential
Alaska Sub Flooring
(AKS-AB846)
Specifications
• Material: Corrugated Polypropylene (see specs below)
• Design: Pre-attached panels that fit inside shelter base frame and accordion up for storage
• Installed under Alaska vinyl flooring to protect against rocks, gravel, etc.
• Can be packed with shelters or with other sets of sub flooring.
Alaska Structures Sub-Floor Specification Tolerance Gauge 8 mm ±0.15 mm Density (grams / sq. meter) 1800 ±5% Density (lbs. / 1000 sq. ft.) 367 ±5% Skin Thickness 0.030” ±0.008” Flute Thickness 0.029” ±0.008” Surface Tension (Dyne Level) 46 dyne / cm (minimum) Normal Temperature Performance Range -17˚F to 160˚F Melting Point 162˚C, 324˚F Notched Izod Impact (ft. lbs. / in.) ASTM-D256-A at 70˚F 3 Tensile Strength at Yield (psi units) ASTM-D638 4000 Elongation at Yield (%) 10 Deflection Temperature (degrees F) at 66 psi 194 Water Absorption – 24 hrs, % ASTM-D570 0.02 Falling Weight Impact Strength at -29˚F (ft. lbs.) 23 Coefficient of Linear Thermal Expansion -30˚C to 0˚C 12 0˚C to 30˚C 14 (MM/MM/C x {10 to the -5th}) 30˚C to 60˚C 21