Alaska Sub Flooring Specs (AKS-AB846) - (Attachment 1).pdf

PDF 578 KB Posted

Attached to
DDXX Alaska Tents Federal contract opportunity
Solicitation number
SP330023Q0185
Issued by
Defense Logistics Agency Distribution

About this file

This document provides specifications for corrugated polypropylene sub flooring panels to be used under vinyl flooring in Alaska tents. The panels are pre-attached and accordion up for storage, fitting inside shelter base frames. Specifications include a tolerance gauge of 8mm, density of 1800 grams/sq meter (367 lbs/1000 sq ft), skin and flute thicknesses of 0.030" and 0.029" respectively, and performance factors such as a melting point of 3240F and notched Izod impact of 3 ft-lbs/in at 700F. The related federal contract opportunity is solicitation number SP330023Q0185 for DDXX Alaska Tents through the Defense Logistics Agency Distribution.

View the file

Other files for this federal contract opportunity

Other files attached to DDXX Alaska Tents, newest first.
File Type Posted
Tab C-6 RFQ SP3300-23-Q-0185 Amendment P00001.pdf PDF
AK-SSS-CONT spec sheet - Attachment 4.pdf PDF
AK-ULC spec sheet - Attachment 3.pdf PDF
Tab C-6 RFQ SP3300-23-Q-0185.pdf PDF
AKS-BA145 Spec Sheet - Attachment 2.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Proprietary and Confidential

Alaska Sub Flooring

(AKS-AB846)

Specifications

• Material: Corrugated Polypropylene (see specs below)

• Design: Pre-attached panels that fit inside shelter base frame and accordion up for storage

• Installed under Alaska vinyl flooring to protect against rocks, gravel, etc.

• Can be packed with shelters or with other sets of sub flooring.

Alaska Structures Sub-Floor Specification Tolerance Gauge 8 mm ±0.15 mm Density (grams / sq. meter) 1800 ±5% Density (lbs. / 1000 sq. ft.) 367 ±5% Skin Thickness 0.030” ±0.008” Flute Thickness 0.029” ±0.008” Surface Tension (Dyne Level) 46 dyne / cm (minimum) Normal Temperature Performance Range -17˚F to 160˚F Melting Point 162˚C, 324˚F Notched Izod Impact (ft. lbs. / in.) ASTM-D256-A at 70˚F 3 Tensile Strength at Yield (psi units) ASTM-D638 4000 Elongation at Yield (%) 10 Deflection Temperature (degrees F) at 66 psi 194 Water Absorption – 24 hrs, % ASTM-D570 0.02 Falling Weight Impact Strength at -29˚F (ft. lbs.) 23 Coefficient of Linear Thermal Expansion -30˚C to 0˚C 12 0˚C to 30˚C 14 (MM/MM/C x {10 to the -5th}) 30˚C to 60˚C 21

File details come from the government source that posted it. Updated .