Attachment_2_Quote_Submittal_Worksheet.docx

DOCX document 18 KB Posted

Attached to
Lighting Upgrade at Mississippi PMC Federal contract opportunity
Solicitation number
AG-2B46-S-17-0025
Issued by
Department of Agriculture National Resources Conservation Service Southeast Region

About this file

Attachment 2 Quote Submittal Worksheet

View the file

Other files for this federal contract opportunity

Other files attached to Lighting Upgrade at Mississippi PMC, newest first.
File Type Posted
AG-2B46-S-17-0025_Amendment_0001_Q&A.pdf PDF
Attachment_3_Frequently_Asked_Questions_and_Answers.pdf PDF
Attachment_1_Statement_of_Work.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RFQ Number: AG-2B46-S-17-0025 Attachment 2

Quote Submittal Worksheet

These services are for the USDA NRCS to upgrade lighting in the shop and adjacent equipment storage shed at the Jamie L. Whitten Plant Materials Center

Line Item
Service
Quantity
Unit

(ea/lot/job)

Unit Cost
Extended Cost
1
Retrofit T8 fluorescent lights in equipment bays (5) and in shop (8) into light-emitting diode (LED) fixtures
13
Each
$
$
2
Repair conduit line that carries compressed air and electricity to end of equipment shed and add new hose and reel. Replace electrical outlets if needed.
1
Job
$
$
3
Replace bathroom bulbs with LED troffer lights (3).
3
Each
$
$
4
Replace exterior lights (2) with LED dusk/dawn automatic lights outside shop office.
2
Each
$
$
5
Replace flood lights (mounted on front of bays and one in front of shop office) with LED dusk/dawn automatic lights outside equipment storage shed (2)
2
Each
$
$

1. Retrofit T8 fluorescent lights in equipment bays (5) and in shop (8) from T8 into LED.

Lighting color temperature will be Daylight (5000k). Existing troffers should be used (if feasible). Existing light switches should be examined and replaced if necessary. Lights will be sized appropriately to completely light each area at or exceeding level of existing light fixtures.

2. Repair conduit line that carries compressed air and electricity to end of equipment shed and add new hose and reel. Replace electrical outlets if needed.

Repair damaged conduit line to make compressed air and electrical outlets functional throughout equipment shed. Add air hose line and new 50ft reel. Reel and hose should be of premium commercial quality.

3. Replace single bulbs with LED troffer lights in two bathrooms (3 fixtures).

Replace bathroom bulbs with LED troffer lights (3). Lighting color temperature will be Daylight (5000k). Existing light switches should be examined and replaced if necessary. Lights will be sized appropriately to completely light each area at or exceeding level of existing light fixtures.

4. Replace two exterior lighting fixtures with LED dusk/dawn automatic lights outside shop office.

Existing fixtures will be replaced with downward-facing lights to limit light pollution and be equipped with automatic sensors that will engage during periods of low light (dawn/dusk or sundown sensors). Lights will be sized appropriately to completely light each area at or exceeding level of existing fixtures.

5. Replace three flood lights (mounted on front of bays) with LED dusk/dawn automatic lights outside equipment storage shed.

Existing fixtures will be replaced with downward-facing lights to limit light pollution and be equipped with automatic sensors that will engage during periods of low light (dawn/dusk or sundown sensors). Lights will be sized appropriately to completely light each area at or exceeding level of existing fixtures.