attachments.pdf

PDF 1 MB Posted

Attached to
West Carson Common Stand Exam Federal contract opportunity
Solicitation number
AG-0261-S-16-0087
Issued by
Department of Agriculture Forest Service R4-Intermountain Region

About this file

Attachments

View the file

Other files for this federal contract opportunity

Other files attached to West Carson Common Stand Exam, newest first.
File Type Posted
ag0261s160087.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIST OF DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS

EXHIBITS

1 Intensive Plots Stand List

2 Aspen Quick Plot Stand List

3 West Carson Stand Exam Vicinity Map

4 West Carson Stand Exam Unit Map

5 Common Stand Exam Inspection Form (sides 1 & 2)

6 Setting Inspection Form and Accuracy Standards

7 Sample Design Inspection Form and Accuracy Standards

8 Plot Data Inspection Form and Accuracy Standards

9 Tree Data (Large Variable Radius Plot) Inspection Form and Accuracy Standards

10 Tree Data (Small Fixed Plot) Inspection Form and Accuracy Standards

11 Ground Surface Cover Inspection Form and Accuracy Standards

12 Vegetation Composition Inspection Form and Accuracy Standards

13 Down Woody Inspection Form and Accuracy Standards

14 Photograph ID Form

15 Example Camping Permit 16 Fire Precautions

EXHIBIT 1 – West Carson Intensive Plot Stand List

Bid Item Setting ID Location Stand Loc.Site Acres Number of Plots

West Carson Intensive 0417010011760001 001176 0001 176.1 168 21

West Carson Intensive 0417010011790002 001179 0002 179.2 67 8

West Carson Intensive 0417010011800003 001180 0003 180.3 177 22

West Carson Intensive 0417010011900001 001190 0001 190.1 118 15

West Carson Intensive 0417010011920001 001192 0001 192.1 82 10

West Carson Intensive 0417010011930001 001193 0001 193.1 78 10

West Carson Intensive 0417010012090001 001209 0001 209.1 27 3

West Carson Intensive 0417010011810001 001181 0001 181.1 78 10

West Carson Intensive 0417010011810005 001181 0005 181.5 47 6

West Carson Intensive 0417010011820006 001182 0006 182.6 98 12

West Carson Intensive 0417010011870006 001187 0006 187.6 74 9

West Carson Intensive 0417010011880001 001188 0001 188.1 76 10

West Carson Intensive 0417010011880003 001188 0003 188.3 123 16

West Carson Intensive 0417010011880004 001188 0004 188.4 74 9

West Carson Intensive 0417010011890001 001189 0001 189.1 83 10

West Carson Intensive 0417010011890002 001189 0002 189.2 30 4

West Carson Intensive 0417010011890003 001189 0003 189.3 46 6

West Carson Intensive 0417010011890004 001189 0004 189.4 34 4

West Carson Intensive 0417010011890005 001189 0005 189.5 54 7

West Carson Intensive 0417010011950001 001195 0001 195.1 158 20

West Carson Intensive 0417010011950002 001195 0002 195.2 71 9

West Carson Intensive 0417010011950002 001195 0002 195.2 81 10

West Carson Intensive 0417010011960005 001196 0005 196.5 32 4

TOTAL 1,876 235

EXHIBIT 2 –Aspen Quick Plot Stand List

Bid Item Plot # Acres # Plots Bid Item Plot # Acres # Plots

Aspen Quick Plot 1 13 3 Aspen Quick Plot 52 44 9

Aspen Quick Plot 2 52 10 Aspen Quick Plot 53 13 3

Aspen Quick Plot 3 19 4 Aspen Quick Plot 54 27 6

Aspen Quick Plot 4 6 3 Aspen Quick Plot 55 16 3

Aspen Quick Plot 5 8 3 Aspen Quick Plot 56 18 4

Aspen Quick Plot 6 7 3 Aspen Quick Plot 57 5 3

Aspen Quick Plot 7 31 6 Aspen Quick Plot 58 16 3

Aspen Quick Plot 8 13 3 Aspen Quick Plot 59 25 5

Aspen Quick Plot 9 5 3 Aspen Quick Plot 60 9 3

Aspen Quick Plot 10 6 3 Aspen Quick Plot 61 11 3

Aspen Quick Plot 11 26 5 Aspen Quick Plot 62 58 12

Aspen Quick Plot 12 16 3 Aspen Quick Plot 63 14 3

Aspen Quick Plot 13 9 3 Aspen Quick Plot 64 9 3

Aspen Quick Plot 14 5 3 Aspen Quick Plot 65 11 3

Aspen Quick Plot 15 11 3 Aspen Quick Plot 66 16 3

Aspen Quick Plot 16 5 3 Aspen Quick Plot 67 15 3

Aspen Quick Plot 17 15 3 Aspen Quick Plot 68 7 3

Aspen Quick Plot 18 16 3 Aspen Quick Plot 69 25 5

Aspen Quick Plot 19 9 3 Aspen Quick Plot 70 8 3

Aspen Quick Plot 20 11 3 Aspen Quick Plot 71 37 7

Aspen Quick Plot 21 6 3 Aspen Quick Plot 72 16 3

Aspen Quick Plot 22 31 6 Aspen Quick Plot 73 47 10

Aspen Quick Plot 23 13 3 Aspen Quick Plot 74 26 5

Aspen Quick Plot 24 15 3 Aspen Quick Plot 75 10 3

Aspen Quick Plot 25 9 3 Aspen Quick Plot 76 5 3

Aspen Quick Plot 26 4 3 Aspen Quick Plot 77 9 3

Aspen Quick Plot 27 7 3 Aspen Quick Plot 78 7 3

Aspen Quick Plot 28 11 3 Aspen Quick Plot 79 15 3

Aspen Quick Plot 29 17 4 Aspen Quick Plot 80 38 8

Aspen Quick Plot 30 11 3 Aspen Quick Plot 81 8 3

Aspen Quick Plot 31 13 3 Aspen Quick Plot 82 26 5

Aspen Quick Plot 32 30 6 Aspen Quick Plot 83 8 3

Aspen Quick Plot 33 21 5 Aspen Quick Plot 84 9 3

Aspen Quick Plot 34 19 4 Aspen Quick Plot 85 7 3

Aspen Quick Plot 35 19 4 Aspen Quick Plot 86 7 3

Aspen Quick Plot 36 25 5 Aspen Quick Plot 87 7 3

Aspen Quick Plot 37 17 4 Aspen Quick Plot 88 6 3

Aspen Quick Plot 38 11 3 Aspen Quick Plot 89 8 3

Aspen Quick Plot 39 22 5 Aspen Quick Plot 90 18 4

Aspen Quick Plot 40 9 3 Aspen Quick Plot 91 22 5

Aspen Quick Plot 41 10 3 Aspen Quick Plot 92 13 3

Aspen Quick Plot 42 5 3 Aspen Quick Plot 93 7 3

Aspen Quick Plot 43 12 3 Aspen Quick Plot 94 10 3

Aspen Quick Plot 44 21 5 Aspen Quick Plot 95 6 3

Aspen Quick Plot 45 30 6 Aspen Quick Plot 96 14 3

Aspen Quick Plot 46 35 7 Aspen Quick Plot 97 12 3

Aspen Quick Plot 47 14 3 Aspen Quick Plot 98 10 3

Aspen Quick Plot 48 63 13 Aspen Quick Plot 99 17 3

Aspen Quick Plot 49 16 3 Aspen Quick Plot 100 7 3

Aspen Quick Plot 50 29 6 Aspen Quick Plot 101 19 4

Aspen Quick Plot 51 8 3 TOTAL ASPEN QUICK PLOTS 1,634 401

EXHIBIT 3 – West Carson Common Stand Exam Vicinity Map

EXHIBIT 4 – West Carson Common Stand Exam Stand Map

EXHIBIT 5

side 1

BLOCK LOCATION STAND FOREST / UNIT

DATE BLOCK RECEIVED DATE BLOCK INSPECTED INSPECTORS

NUMBER OF STANDS: NUMBER OF STANDS INSPECTED: L.S. TREE RECORDS INSPECTED:

NUMBER OF PLOTS: NUMBER OF PLOTS INSPECTED: S.S. TREE RECORDS INSPECTED:

OFFICE INSPECTION

ACCEPTABLE N/A

ALL REQUIRED MATERIALS RETURNED IN GOOD CONDITION

CORRECT NUMBER OF PLOTS COMPLETED IN EACH STAND

ALL REQUIRED FORMS AND FIELDS COMPLETED AND LEGIBLE

MINIMUM NUMBER OF SITE/GROWTH TREES COLLECTED FOR EACH SITE

ALL STANDS MEET MINIMUM TREE PER PLOT AVERAGES

ELECTRONIC DATA COMPLETE AND ACCEPTABLE

FIELD INSPECTION

ACCEPTABLE N/A

ALL REFERENCE POINTS AND PLOT CENTERS RELOCATABLE

ALL PLOT LOCATIONS CORRECT AND UNBIASED

ALL STANDS HAVE A PLOT DISTRIBUTION THAT

EQUALLY SAMPLES ALL PORTIONS OF THE ENTIRE STAND

SUFFICIENT ERRORS ACCUMULATE TO INDICATE A DISCREPANCY TREND

ALL INFORMATION ON SAMPLE DESIGN FORMS COMPLETE AND CORRECT

ALL STANDS AND PLOTS HAVE CORRECT STAND ID (LOCATION, STAND)

TOTAL FORM SCORE CALCULATION

Setting Form Score Sample Design Form Score Plot Form Score Total Tree Form Score Ground Surface Cover Form Score Vegetation Composition Form Score Downed Woody Form Score

TOTAL SCORE (sum of all scores)

OFFICE AND FIELD INSPECTION

-- ANY UNACCEPTABLE ITEM FAILS INSPECTION BLOCK

INSPECTION BLOCK

TOTAL FORM SCORE CALCULATION

All form scores < 5.0 and Total Score < 10.0 = pass (full payment) PASS

Any Form >= 5.0 = rework forms that fail for entire inspection unit

Total Score >= 10.0 = rework entire inspection unit FAIL

Errors in any field that has a Point Value of "unacceptable" will fail the block

INSPECTION CREW SIGNATURES:

DATE

DATE

COMMENTS AND FOLLOW-UP ACTION on side 2

UNACCEPTABLE

COMMON STAND EXAM INSPECTION FORM

UNACCEPTABLE

EXHIBIT 5 (cont’d)

COMMON STAND EXAM INSPECTION FORM SIDE 2

EXHIBIT 6 ‐ SETTING INSPECTION FORM AND ACCURACY STANDARDS

SETTING INSPECTION FORM AND ACCURACY STANDARDS A B C

NAME ACCURACY STANDARD POINT VALUE # OF ERRORS

DEDUCTION

(A X B) Region no errors 1 Proclaimed Forest no errors 3 District no errors 3 Location no errors unacceptable Stand Number no errors unacceptable Ownership no errors 1 State no errors 1 County no errors 1 Administrative Forest no errors 1 Date no errors 2 Photo ID no errors 1 Exam Level no errors 3 Exam Purpose no errors 2 Stratum no errors 2 Existing Veg no errors 5 Potential Veg Reference no errors 1 Potential Veg no errors 20 Structure no errors 2 Cap. Growing Area % + 10 percent 1 Fuel Model no errors 2 Elevation + 2 contour intervals 3 Aspect + 45 degrees 3 Slope + 10 percent 2 Slope Position + 1 class 1 Acres no errors 1 Radial Growth Interval no errors 3 Radial Growth Interval #2 N/A N/A Height Growth Interval no errors 3 Fuel Photo Reference N/A N/A Precision Protocol N/A N/A Examiner no errors 1 Setting Remarks Complete and accurate 3 Damage Category no errors 2 Damage Agent no errors 1 Damage Severity no errors 1 Species of Mgt. Interest no errors 1 Sketch Map & Traverse Notes Complete and Thorough 3 Total Deductions (sum of column C') D � Number of Stands Inspected E � Setting Form Score (D ÷ E) F �

EXHIBIT 7 SAMPLE DESIGN INSPECTION FORM AND ACCURACY STANDARDS

A B C

FIELD NAME

ACCURACY

STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTIO

N (A X B)

1 Form Type no errors unacceptable

2 Selection Method Type no errors unacceptable

3 Sample Expansion Factor no errors unacceptable

4 Starting Azimuth no errors unacceptable

5 Plots Installed no errors unacceptable

6 Subpop Filter no errors unacceptable

7 Sample/Select Remarks no errors unacceptable

8 Selection Criteria no errors unacceptable

9 Subpop Variable no errors unacceptable

10 Subpop Min Value no errors unacceptable

11 Subpop Max Value no errors unacceptable

Total Deductions (sum of column 'C') D �

Number of Stands Inspected E �

Sample Design Form Score (D ÷ E) F �

EXHIBIT 8

PLOT DATA INSPECTION FORM AND ACCURACY STANDARDS

FIELD NAME ACCURACY STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A X B)

1 Plot Number no errors 10 2 Plot Latitude no errors 6 3 Plot Longitude no errors 6 4 Cap. Growing Area % + 10% 2 5 Plot Aspect + 45 degrees 6 6 Plot Slope % + 10% 6 7 Slope Position + 1 class 6 8 Slope Horizontal Shape + 1 class 2 9 Slope Vertical Shape + 1 class 2

10 Elevation + 2 contour intervals 6 11 Existing Veg no errors 10 12 Potential Veg 1) 10 13 Plot History no errors 6 14 Plot History Date 2) 2 15 Fuel Model no errors 2 16 Residue Descriptive Code N/A N/A 17 Distance to Seed Wall N/A N/A 18 Remarks complete and accurate 10

Total Deductions (sum of column 'C') D � Number of Plots Inspected E �

Plot Form Score (D÷ E) F �

1) Accurate to series understory union and phases

2) Year required if field #13 is other than code 10 or blank

EXHIBIT 9–TREE DATA LARGE VARIABLE RADIUS PLOT INSPECTION & ACCURACY STANDARDS

FIELD NAME

ACCURACY

STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A x B)

1 Plot Number No Errors 10

2 Tag ID Number No Errors 10

3 Tree Status No Errors 50

4 No Errors 50

4 No Errors 20

5 Tree Species No Errors 50

6 *Tree Count * *

7 Number of Stems No Errors 2

8 DBH/DRC 1)

9 Tree Height + 10% 10

10 Height to Crown + 10% 2

11 Radial Growth + 1/20 inch 5

12 Radial Growth #2 N/A N/A

13 Height Growth + 1 foot 5

14 Tree Age + 10% 10

15 Crown Ratio + 10% 5

16 Crown Class No Errors 5

17 Crown Width No Errors 5

18 Wildlife Use No Errors 2

19 Log/Snag Decay No Errors 5

20 Cone Serotiny N/A N/A

21 Damage Category No Errors 10

22 Damage Agent No Errors 2

23 Damage Part No Errors 2

24 Damage Severity No Errors 5

25 Tree Remarks No Errors 10

Large Sample Plot Deduction (sum of column C) D

Large Sample Plot Tree Records Inspected E

Large Sample Plot Score (D / E) F

*Refer to Common Stand Exam 1) DBH/DRC Accuracy Standards Field Guide Region 4 for Specific DBH Range Accuracy Accuracy Standards and Point Values. <0.5 inch No Errors

0.5 to 13.9 inches + 0.1 inch

14.0 to 23.9 inches + 0.2 inch

24.0 to 34.9 inches + 0.4 inch >35 inches + 0.5 inch

Quick Plot Accuracy Standards are to 2‐Inch Diameter Class

EX. 10–TREE DATA SMALL VARIABLE RADIUS PLOT INSPECTION & ACCURACY STANDARDS

SMALL SAMPLE PLOT (S.S.) -- Small Fixed Area Plot A B C

FIELD NAME

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A X B)

1 Plot Number 10

2 Tag ID Number 10

3 Tree Status 20

4 Site Tree/GST - field correct 10

5 Tree Species 10

6 Tree Count 20

7 Number of Stems 2

8 DBH/DRC 10

9 Tree Height 10

10 Height to Crown 2

11 Radial Growth 5

12 Radial Growth #2 5

14 Tree Age 10

15 Crown Ratio 5

16 Crown Class 5

17 Crown Width 5

18 Wildlife Use 2

19 Log/Snag Decay 5

20 Cone Serotiny 5

21 Damage Category 10

22 Damage Agent 2

23 Damage Part 2

24 Damage Severity 5

25 Tree Remarks 10

S.S. Deductions (sum of column 'C') D

S.S. Tree Records Inspected E

S.S. Sample Score (D ÷ E) F

Total Tree Form Score (Sum of L.S. score and S.S. score)

1) Tree Count (small sample plot) Accuracy Stds: 2) DBH/DRC Accuracy Standards:

Height Diameter Actual Trees Accuracy a. < 0.5 inch no errors

Range Range On Plot Standard b. 0.5 inch to 13.9 inches + 0.1 inch

*All All 0 0 trees

< 0.5 feet 1 - 5 + 2 trees < 0.5 feet >= 6 + 50%

>= 0.5 feet < 0.5 feet 1 - 5 + 1 tree >= 0.5 feet < 0.5 feet >= 6 + 20%

All 0.5" - brkpt dbh 1 - 5 + 1 tree All 0.5" - brkpt dbh >= 6 + 10%

All >= brkpt dbh >= 1 0 trees

*There is no tolerance for recording a tree when none are actually present in any of the above size classes. The recording of a fixed plot tree when none are present will result in a single discrepancy.

*Grouping criteria are standardized to facilitate stand exam contract inspection and payment. However, distinguishing characteristics other than tree class, species, and size class may warrant individual tre recording or more refined grouping criteria. Such characteristics include age, crown ratio, crown class, or incidence of damage.

13 5

ACCURACY STANDARD

no errors no errors no errors no errors no errors

1) no errors for DRC species

2)

+ 10 %

+ 10 %

+ 1/20 inch

+ 1/20 inch Height > 6 ft + 1.0 foot Height <= 6 ft + 0.1 footHeight Growth

+ 10 %

+ 10 % no errors

+ 20% no errors no errors no errors complete and accurate no errors no errors no errors no errors

Exhibit 11

GROUND SURFACE COVER

INSPECTION FORM AND ACCURACY STANDARDS

EXHIBIT 12 VEGETATION COMPOSITION

INSPECTION FORM AND ACCURACY STANDARDS

GROUND SURFACE COVER FORM

FIELD NAME ACCURACY STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A X B)

1 Plot Number no errors 5

2 Surface Cover Type no errors 3

3 Surface Cover % + 10 % 3

4 Remarks

Total Deductions (sum of column 'C') D �

Number of Plots Inspected E �

Ground Surface Cover Form Score (D ÷ E) F �

VEGETATION COMPOSITION FORM

A B C

FIELD NAME ACCURACY STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A X B)

1 Plot Number no errors 5 2 Live/Dead no errors 3 3 Layer no errors 1 4 Life Form no errors 5 5 Species 1) 5 6 Min. Layer Height + 10 % of height 3 7 Ave. Layer Height + 10 % of height 3 8 Max. Layer Height + 10 % of height 3 9 Canopy Cover + 10 % 5 10 Average Diameter no errors 1 11 Maturity no errors 1 12 Remarks

Total Deductions (sum of column 'C') D Number of Plots Inspected E

Vegetation Composition Form Score (D ÷ E) F

1) No Error in species level identification for dominant, common or cummity type indicator plants. No plant name can be repeated in a

Species present but not recorded

EXHIBIT 13

DOWN WOODY MATERIAL

INSPECTION FORM AND ACCURACY STANDARDS

A B C

FIELD NAME ACCURACY STANDARD

POINT

VALUE

# OF

ERRORS

DEDUCTION

(A X B)

1 Plot Number no errors 5

2 First Duff + 1/2 inch 3

3 Second Duff + 1/2 inch 3

4 Fuel Depth No Errors 3

5 Twig 0 - 0.24 + 40% 3

6 Twig 0.25 - 0.99 + 30% 3

7 Twig 1.0 - 2.99 + 20% 3

8+ Volume N/A

9+ Weight N/A

16 Piece Count no missed pieces 3

17 Decay Class No Errors 3

18 Diameter + 1 inch on measurements 3

19 Piece Length No Errors 3

Total Deductions (sum of column 'C') D �

Number of Downed Woody Records Inspected E �

Down Woody Form Score (D ÷ E) F �

EXHIBIT 14 – PHOTGRAPH ID FORM

EXHIBIT 15

SAMPLE CAMPING AUTHORIZATION

Dear XX , The employees of Stand Exam Contractor working on the West Carson Stand Exam Contract, Contract #xx-xxxx-x-xxxx, are hereby authorized to camp on the Humboldt-Toiyabe National Forest, Carson Ranger District until the contract is completed or November 30, 2016, whichever occurs first.

The following provisions apply to all camping on National Forest lands, during performance of this agreement:

1. Before final acceptance, all areas occupied by the Contractor in connection with the work shall be cleaned of all Contractor's rubbish, excess materials, temporary structures, and equipment, and all parts of the work shall be left in a neat and presentable condition. Campsite will be inspected prior to payment.

2. The campsite shall have a clean appearance at all times, all garbage will be hauled to the nearest authorized dumping site (not buried).

3. Unless otherwise designated by a Forest Service representative, the use of this area is not exclusive, and may be granted to other Permittees or recreating public. Disorderly conduct is not permitted.

4. Damaging or removing any natural feature or other property of the Forest Service is prohibited.

5. No wastewater may be dumped on the ground within 200 feet of creeks or lakes.

6. The contractor shall take all reasonable precautions to prevent and suppress forest fires. No material shall be disposed of by burning in open fires during the closed season established by law or regulation without a written permit from the Forest Service.

7. The contractor must comply with the following fire regulations:

a. A campfire permit (Form R5-FS-5100-54).

b.A shovel, and a fire extinguisher with an Underwriters Laboratory (UL) rating of at least 5 B, C is required during the fire season.

c. All generators and other internal combustion engines shall be equipped with USFS approved spark arrestors and/or factory designed muffler and exhaust system in good working order. They shall be located in a cleared area.

8. Any violation of these conditions may result in revocation of camping approval.

9. The Forest Service reserves the right to terminate this permit at any time.

Sincerely, IRENE DAVIDSON

District Ranger

FIRE PRECAUTIONS

This plan outlines the channels of responsibility for fire prevention and suppression activities and sets up an attack procedure in the event of fire within the Project Area. The Project Area is defined as that area which is in and adjacent to the project rights-of-way and work areas and all roads used in connection with the work.

I. Responsibilities

A. Contractor-Fire Suppression

1. It is understood and agreed that the Contractor will do all in his/her power to prevent and suppress fires on or adjacent to the Project Area, as stipulated in the contract.

2. Responsible for and will direct all fire activities on the project until relieved by a Forest Officer and will insure that prevention and suppression actions are in accordance with contract requirements, including this fire plan. Contractor shall delegate the next highest in authority on the job to be responsible for the above activities when he/she is not on the project.

3. In line with this agreement, individuals will be supplied from the Contractor's crews to fight fires on the project area up to the total number of individuals employed by the Contractor as they are needed by the Fire Boss. The Forest Service will make every effort to avoid calling on the Contractor for action on fires outside the contract project area except in emergencies and will call out all needed available help to control fires in the general area.

4. The Contractor insures that this Fire Plan will be complied to for the duration of the contract.

B. Forest Service District Ranger

1. Responsible for all fire activities on the Ranger District on which the contract project is located.

District Ranger's representative will discuss the fire plan with the Contractor including needed equipment and action to be taken when a fire occurs. Will notify the Contractor through the Contracting Officer's Representative (COR) to take correction measures when fire requirements are in compliance.

II. Contractor's Responsibility When Fire Occurs Within the Contract Project Area

A. Immediately send the entire contract crew with tools and equipment to the fire and take initial-attack suppression action.

B. Immediately notify the nearest Forest Service Fire Control Officer or other Forest Service employee of fire location and action taken.

C. Designate a person to act as dispatcher who will handle messages and initiate action upon request until relieved.

III. Contractor Furnished Manpower, Tools, and Equipment Required on all Contracts During Fire Season

A. The Contractor shall furnish to the COR a list of manpower and equipment used on the contract on forms furnished by the Forest Service. Changes in Contractor's personnel shall be reflected in amendment to the list.

Fire Prevention

Smoking: Prohibited in the woods during the fire season, May 10 - October 20, except in areas agreed upon by the Contractor and COR. No smoking is permitted while walking or working in the woods.

Refueling Chainsaw/Soil Auger: Refueling will be confined to a six-foot diameter cleared to mineral earth. Chainsaws/soil auger spark arresters shall be U.S. Forest Service approved, and will be cleaned daily. A size "O" or larger round-pointed shovel with a minimum of a 38 ½-inch handle and a fire extinguisher shall be within 10 feet of actual point of chainsaw/soil auger operation.

Burning, Blasting, or Welding: Permit will be required and will contain special stipulations pertinent to the particular job.

Spark Arresters: All internal combustion power equipment used by the Contractor on the project shall be equipped with an approved spark arrester as set forth in the publication of the USDA Forest Service, entitled "Standard 5100-1a for Spark Arresters for Internal Combustion Engines" as amended under date of July 1970, and be listed in the most recent "Spark Arrester Guide" as having been approved as meeting above standard. They shall be cleaned regularly and maintained in satisfactory working condition. The following are exempt from the requirements of the rule: (a) turbo-charged internal combustion engines in which 100 percent of the exhaust gasses pass through a turbo-charger; (b) engines of passenger carrying vehicles and light trucks equipped with a muffler with baffles that are kept in good repair (glass packs are not an approved muffler for wildland work); (c) water pumping equipment used in firefighting.

Spark arrester shall comply with all State and Federal fire requirements.

Lunch and Warming Fires: Cooking and warming fires will not normally be permitted and then only by written permit by the COR which contains stipulations regulating use of such fires.

Hand Tools: The Contractor shall furnish one size "O" shovel (38 1/2 inch handle minimum) or larger, one axe or pulaski with 26 inch handle or larger, one 5 BC or larger rated pressurized fire extinguisher for each truck, each personal vehicle, each tractor, and each grader. For each welder he shall furnish on size "O" shovel and one backpack pump. For each gasoline power tools (power saw, soil auger, etc.), one shovel (38 1/2 inch handle minimum) and one 8 ounce or larger BC rated chemical-pressurized fire extinguisher.

Contractor shall also furnish any other equipment called for elsewhere in the contract. The shovel and fire extinguisher will be located within 10 feet of the operating chainsaw/power auger.

Storage and Parking Areas: Equipment service area, parking area, and gas and oil drum storage areas will be cleared of all flammable material for a radius of at least fifty feet. These areas must be approved in writing by the COR in advance of use. Small stationary engine sites shall be cleared of flammable material for a radius of at least five feet from such engine.

Fire Tool Box: A red fire toolbox will be required to be on each work site while work is being performed.

This fire toolbox will contain sufficient tools to equip all persons engaged in Contractor's operation. Fire tools shall be used only for suppressing wildfires. Tools shall be stored in fireboxes provided by the Contractor and readily available to employees. Each toolbox shall be marked "Tools for Fire Only". The COR will inspect the fire toolbox and then seal the box.

File details come from the government source that posted it. Updated .