Addendum_1.docx

DOCX document 13 KB Posted

Attached to
FY21 HOFU FURNACE STACK STABILIZATION Federal contract opportunity
Solicitation number
140P4221R0015
Issued by
Department of the Interior National Park Service Northeast Region

About this file

This addendum modifies details for the bluestone coping specified in drawings for the FY21 HOFU FURNACE STACK STABILIZATION project solicited by the Department of the Interior National Park Service Northeast Region. The addendum changes the overhang requirement for the bluestone from 1 inch to 1/2 inch for both the inner and outer elevations at the brick parapets. It also modifies the thickness specification at the inner elevation from 2 1/2 inches to 2 inches and sets the maximum thickness allowed at the outer elevation to 1 inch. All other aspects of the original drawing details remain the same.

View the file

Other files for this federal contract opportunity

Other files attached to FY21 HOFU FURNACE STACK STABILIZATION, newest first.
File Type Posted
HOFU_Furnace_Stack_Stabilization_Questions_and_Answers_0002.pdf PDF
Sol_140P4221R0015_Amd_0002.pdf PDF
site_visit_furnace_stack_0002.pdf PDF
Sol_140P4221R0015_Amd_0001.pdf PDF
Form_A.docx DOCX document
References_Worksheet.doc DOC document
All_Final_100__Specs_052920.pdf PDF
Sol_140P4221R0015.pdf PDF
hofu_Drawings_CD_set_combined_0529_20.pdf PDF
Wage_Determination_PA_20210083_Chester_County_7-2-21.pdf PDF
Form_B.docx DOCX document
Bid_Guarantee_SF24-16d.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum 1 HOFU Furnace Structure Repairs 03/04/2021 The purpose of this addendum is to provide the compliance requirement(s) for the bluestone coping at the brick parapets. These requirements will take precedence over the corresponding information found on drawing A3 detail 1.

1. Bluestone is shown to overhang the parapet by 1 inch on the outer elevation. This addendum shall modify this requirement to reflect a ½ inch overhang for both the inner and outer elevations.

2. Bluestone thickness at the inner elevation is shown at 2 ½ inches. This addendum shall modify this dimension to 2 inches. Additionally, the thickness at the outer elevation shall not exceed 1 inch.

All other items in this detail shall remain as found on the original drawings dated 05/29/2020.