HASKELL_BLDG_112_DRAWINGS.pdf

PDF 3 MB Posted

Attached to
Parker Hall Lecture Room Renovation Project Federal contract opportunity
Solicitation number
A15PS00217
Issued by
Department of the Interior Bureau of Indian Affairs Central Office

About this file

Building 112 Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Parker Hall Lecture Room Renovation Project, newest first.
File Type Posted
HINU_BLDG_112_-ADDENDUM_FIVE.pdf PDF
Sol_A15PS00217_Amd_000004.pdf PDF
Sol_A15PS00217_Amd_000003.pdf PDF
Sol_A15PS00217_Amd_000002.pdf PDF
Sol_A15PS00217_Amd_000001.pdf PDF
HASKELL_BLDG_112_SPECS.pdf PDF
Wage_Rates_KS150010.pdf PDF
Sol_A15PS00217.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

CAMPUS MAP

GENERAL NOTES

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

DRAWING INDEX

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :0

P

M

BUILDING 112 - ROOM 110 LECTURE HALL

155 EAST INDIAN AVE., LAWRENCE, KS

HASKELL INDIAN NATIONS UNIVERSITY

G-001

C O

V E

R S

H E

E T

IN

D E

X

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W G

-0

CONSTRUCTION SUBMITTAL

A m e ri c a s P k w y N

E S u it e

A lb q u e r q u e

N

M

-2

-0

F a x

-2

-4 w w w .w h p a ci fic .c o m

GENERAL

G-001 COVERSHEET & INDEX

G-101 BLDG 112 - CODE & LIFE SAFETY ANALYSIS

ARCHITECTURAL

AD-100 BLDG 112 - OVERALL DEMO. FLOOR PLAN

AD-101 BLDG 112 - DEMO. PHOTOS & DETAILS

AD-102 BLDG 112 - DEMO. REFL. CEILING PLAN

A-100 BLDG 112 - OVERALL NEW WORK PLAN

A-101 BLDG 112 - FLOOR & REFL. CEILING PLAN

A-102 BLDG 112 - ENLARGED PLAN & ELEV.

A-401 BLDG 112 - ELEVATIONS & DETAILS

A-501 BLDG 112 - DETAILS

A-601 BLDG 112 - DOOR/WINDOW SCHEDULES

A-602 BLDG 112 - SCHEDULES

PROJECT LOCATION

HASKELL INDIAN NATIONS

UNIVERSITY

PARKER HALL BUILDING 112

ELECTRICAL

E-001 LEGEND,SCHEDULES & ABBREVIATIONS

ED-101 BLDG 112 - ELECTRICAL DEMO. PLAN

E-101 BLDG 112 - LIGHTING PLAN

E-201 BLDG 112 - POWER PLAN

E-301 BLDG 112 - SPECIAL SYSTEM PLAN

E-501 BLDG 112 - SCHEDULES & DETAILS

PLUMBING

P-001 PLUMBING NOTES AND LEGENDS

PD-101 BLDG 112 - PLUMBING DEMOLITION PLAN

P-101 BLDG 112 - PLUMBING PLAN

P-501 BLDG 112 - PLUMBING DETAILS

P-601 BLDG 112 - PLUMBING SCHEDULES

MECHANICAL

M-001 MECHANICAL NOTES AND LEGENDS

MD-101 BLDG 112 - HVAC DEMOLITION PLAN

M-101 BLDG 112 - HVAC PLAN

M-102 BLDG 112 - HVAC ROOF PLAN

M-301 BLDG 112 - HVAC SECTIONS

M-501 BLDG 112 - MECHANICAL DETAILS

M-601 BLDG 112 - MECHANICAL SCHEDULES

M-701 BLDG 112 - HVAC CONTROL DIAGRAMS

STRUCTURAL

S-101 BLDG 112 - CANOPY PLAN & DETAILS

A. THE CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL EQUIPMENT

AND FURNITURE IN ORDER TO EXECUTE AND COMPLETE THE SCOPE

OF WORK IDENTIFIED IN THE CONSTRUCTION DOCUMENTS. THE EXISTING

FURNITURE SHALL EITHER BE REMOVED AND STORED

WHERE INDICATED BY THE HASKELL REPRESENTATIVE, REMOVED AND

RELOCATED TO ANOTHER AREA OF WORK, OR REMOVED AND

REINSTALLED IN THE SAME LOCATION. THE FURNITURE AND EQUIPMENT

LIST MAY NOT BE ENTIRELY CONCLUSIVE. CONTRACTOR SHALL

DOCUMENT, BY PHOTO, THE LOCATION OF ALL FURNITURE PRIOR TO

REMOVAL FROM THE SPACES. IF THE LOCATION OF THE FURNITURE AND

EQUIPMENT IS UNCLEAR OR CONFLICTS WITH AN EXISTING CONDITION,

CONSULT WITH THE HASKELL UNIVERSITY REPRESENTATIVE FOR

CLARIFICATION. THE CONTRACTOR WILL RETURN ALL UNUSED

FURNITURE AND EQUIPMENT BACK TO THE UNIVERSITY.

B. EXISTING CONDITIONS COULD AFFECT THE INSTALLATION OF ANY

WORK SET FORTH IN THESE PLANS. CONSTRACTOR IS RESPONSIBLE

FOR VERIFYING ALL DIMENSIONS.

C. SMOKE SEAL ALL PENETRATIONS AROUND PIPE/CONDUIT AT

ALL FLOOR, WALL, DECK AND ROOF PENETRATIONS.

D. ALL TERMINATIONS OF ONE FLOOR MATERIAL TO ANOTHER FLOOR

MATERIAL SHALL HAVE TRANSITION OR REDUCER STRIPS.

E. ALL MATERIALS REQUIRED SHALL BE OF A GRADE AND QUALITY

CONSISTENT WITH THE SURROUNDING MATERIAL AND APPROVED

BY THE OWNER.

F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE

EXISTENCE AND LOCATION OF ANY CONCEALED LINES THAT MAY BE

REQUIRED TO BE REMOVED OR AVOIDED DURING CONSTRUCTION.

G. INSTALL GYPSUM BOARD CONTROL JOINTS AT ALL LOCATIONS

INDICATED OR IF NOT INDICATED AS ACCORDING TO THE

REQUIREMENTS THAT ARE ESTABLISHED IN THE SPECIFICATIONS.

H. REFER TO CODE ANAYLSIS PLANS AND WALL TYPES FOR THE FIRE

RATED ASSEMBLIES AND COMPLETE DESCRIPTIONS OR WALL

CONSTRUCTION.

I. INSTALL A CONTINUOUS BEAD OF SEALANT AT ALL GAPS/SEAMS

BETWEEN FIXED EQUIPMENT AND WALLS OR OTHER ASSEMBLIES.

J. STUD PARTITIONS ARE DIMENSIONED TO FACE OF STUD. ALL ROUGH

OPENINGS ARE LOCATED 4" TO NEAREST ADJACENT WALL UNLESS

INDICATED OTHERWISE.

K. REFERENCE ALL DISCIPLINES FOR COORDINATION OF WORK.

L. CONTRACTOR SHALL MAINTAIN A CLEAN, DUST FREE SEPARATION

BETWEEN WORK AREAS AND OCCUPIED AREAS OF THE BUILDING.

M. UNLESS NOTED OTHERWISE ALL BLOCKING OR BACKING MATERIAL

SHALL BE 18 GAUGE SHEET METAL FOR ALL WALL MOUNTED ITEMS.

N. CONTRACTOR SHALL REVIEW ASBESTOS & LEAD PAINT REPORT ON

WORK AREAS FROM HASKELL AND SHALL ABATE/REMOVE ALL

MATERIALS REQUIRED TO INSTALL NEW FINISHES

**NOTES APPLY TO ALL SHEETS**

CIVIL

C-101 DEMO AND NEW PARKING PLANS

/0

/2

DN

UP

STORAGE

STORAGE

109A

VESTIBULE

110B

MECHANICAL

110A

LECTURE HALL

WOMEN

104AMEN

104B

JANITOR

104C

2012 NFPA 5000 - BUILDING CONSTRUCTION AND SAFETY CODE

ASCE/SEI 7-10 - MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER

STRUCTURES

2012 UNIFORM PLUMBING CODE

2012 UNIFORM MECHANICAL CODE

2014 NATIONAL ELECTICAL CODE

2012 NFPA 101, NFPA 10, & NFPA 80

2009 NFPA 54 NATIONAL FUEL GAS CODE

2004 NFPA 45 - FIRE PROTECTION FOR LABORATORIES USING

CHEMICALS

2004 AMERICANS WITH DISABILITY ACT AND ARCHITECTURAL BARRIERS

ACT ACCESSIBILITY GUIDELINES (26 CFR, PART 1191: ADAABAAG

CODE ANALYSIS (NFPA 5000):

BUILDING AREA: EXISTING - 33,178 TOTAL GSF

NEW - NONE

TOTAL GROSS FLOOR AREA = 33,178 TOTAL GSF

MAJOR OCCUPANCY: BUSINNESS/ASSEMBLY (SEC. 6.1.11 & 6.1.2)

THIS BUILDING WORK IS CLASSIFIED AS RECONSTRUCTION (SEC.15.2.2.4). WORK IS

RECONFIGURATION OF THE SPACE WITH A NEW EXTERIOR ACCESSIBLE EXIT. LECTURE HALL 110 WILL

BE MODIFIED FROM A CLASSROOM TO A LECTURE SPACE. THE EXISTING RESTROOM WILL BE

RECONFIGURED TO ADD A FEMALE RESTROOM AND EXISTING SURFACES WILL BE REMOVED AND

REPLACED. THE EXISTING OFFICES AND STORAGE AREAS WILL HAVE ASBESTOS REMEDIATED AND

NEW FINISHES INSTALLED. NO OTHER WORK WILL OCCUR IN THESE AREAS.

OCCUPANT LOAD FACTOR: (TABLE 11.3.1.2)

OFFICE 103 - 796 SF/100 GSF 8 OCCUPANTS - NO CHANGE

OFFICE 103A - 425 SF/100 GSF 5 OCCUPANTS - NO CHANGE

MENS 104A - 112 SF - N/A 0 OCCUPANTS

WOMEN'S 104B - 66 SF - N/A 0 OCCUPANTS

JANITOR 104C - 42 SF - N/A 0 OCCUPANTS

CLASSROOM 105 - 525 SF/20 NSF 27 OCCUPANTS - NO CHANGE

STORAGE 108 - 111 SF/500 SF 1 OCCUPANT - NO CHANGE

STORAGE 109 - 97 SF/500 SF 1 OCCUPANT - NO CHANGE

STORAGE 109A - 157 SF/500 SF 1 OCCUPANT - NO CHANGE

LECTURE HALL 110 - 2,112 SF/ 15 NSF 141 OCCUPANTS

TOTAL MODIFIED AREA OCCUPANCY: 184 OCCUPANTS

CONSTRUCTION TYPE: TYPE II 000 - NON SPRINKLERED

FIRE RESISTANCE RATING: (TABLE 7.2.1.1)

EXTERIOR NON-BEARING WALLS: 0 HR

INTERIOR NON-BEARING WALLS: 0 HR

FLOOR/CEILING ASSEMBLIES: 0 HR

NO AUTOMATIC SPRINKLER SYSTEM PROVIDED

MEANS OF EGRESS:

CLASSROOMS AND OFFICES (CHAPTER 11 & 28):

EGRESS WIDTH (WORST CASE): .2 x 42 = 8.4" REQUIRED 32" PROVIDED (TABLE 11.3.3.1)

NUMBER OF MEANS OF EGRESS: 2 REQUIRED 2 PROVIDED (SEC. 28.2.4.1 - 2)

COMMON PATH OF EGRESS TRAVEL: 75 FEET MAX 25 ACTUAL

LECTURE HALL (CHAPTER 11 & 16):

EGRESS WIDTH = .2 x 141 = 28.2" REQUIRED 96" PROVIDED (TABLE 11.3.3.1)

NUMBER OF MEANS OF EGRESS: 2 REQUIRED 2 PROVIDED (SEC. 11.4.1.1)

MAIN EXISTING EXIT PASSAGE WAY IS ASSUMED TO BE ONE-HOUR RATED PER CHAPTER 11.1.3.2.1.1.

NFPA 10: FIRE EXTINGUISER REQUIREMENTS:

CHAPTER 5.2.1 - BUILDING FIRE CLASSIFICATION TYPE: CLASS A

CHAPTER 5.4.1.1 - LIGHT HAZARD OCCUPANCY CLASSIFICATION

CHAPTER 6.2.1.1 - LIGHT (LOW) HAZARD OCCUPANCY REQUIREMENTS

MIN. RATED EXTINGUISHER - TYPE 2A

MAX DISTANCE TO EXTINGUISHER - 75 FT

MAX AREA (PER UNIT 'A') - 3000 SF

CLASSROOM/OFFICE/STORAGE: 1 REQUIRED 3 PROVIDED (IN CLASSROOM & OFFICES)

LECTURE HALL: 1 REQUIRED 1 PROVIDED

ALL FIRE EXTINGUISHERS SHALL BE BRACKET MOUNTED ON THE WALLS 48" A.F.F.

PROVIDE TYPE "ABC 5-ALV-W" BY STRIKE FIRST CORPORATION OF AMERICA (OR EQUAL).

SEE SHEET CODE PLAN FOR LOCATIONS.

FIXTURE ANALYSIS:

PLUMBING FIXTURES REQUIRED (UPC TABLE 422.1) - ANALYSIS FOR NEW LECTURE HALL ONLY:

TOTAL A-3 OCCUPANTS: 72 36- MALE 36- FEMALE

WATERCLOSETS: REQUIRED: EXISTING NEW TOTAL

MALE 1 1 0 1

FEMALE 2 0 2 2

URINALS:

MALE 1 0 0

LAVATORIES:

MALE 1 1 0 1

FEMALE 1 0 1 1

DRINKING FOUNTAINS: 1 1 0 1

SERVICE SINKS: 1 1 0 1

APPLICABLE CODES:

4' - 0" 4' - 0"

BRACKET MOUNTED

FIRE EXTINGUISHER

BRACKET MOUNTED

FIRE EXTINGUISHER

1-HR RATED

AREA OF NEW WORK

SHOWN IN B1/G101

AC CESSIBLE

DRINKING

FOUNTAIN

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :0

P

M

A s in d ic at ed

G-101

B L

D G

C

O D

E

L

IF

E S

A F

E T

Y A

N A

L Y

S

IS

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W G

-1

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

1/8" = 1'-0" B1

BUILDING 112 - CODE & LIFE SAFETY ANALYSIS

N

SCALE: 1/8" = 1'-0"

0' 4' 8' 16' 32'

1" = 30'-0" A1

FLOOR PLAN

37' - 0"9' - 2" 4' - 8" 9' - 2" 2' - 4" 4

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\w fr a n k \D o c u m e n ts \H

A S

K E

L L

A

R C

H C

E N

T R

A L w fr a n k .r v t

/8

/2

:2 :2

P

M

/8

'-0

C-101

D E

M O

A N

D N

E W

P A

R K

IN

G

P L

A N

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

C h e ck e r

A u th o r

D e si g n e r

P

7W C

-1

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

1/8" = 1'-0"

NEW PARKING PLAN

1/8" = 1'-0"

FLOOR PLAN

KEYED NOTES

1 REMOVE EXISTING PARKING STRIPING

2 REMOVE ASPHALT & BASE COURSE

3 REMOVE EXISTING CONCRETE LANDING,

STAIRS, & RAILING

4 EXISTING CONCRETE DRAIN SWALE TO

REMAIN

5 EXISTING PARKING STRIPING TO REMAIN

6 EXISTING ASPHALT TO REMAIN

7 BRICK PAVERS TO MATCH TYPE AND COLOR

OF SIMILAR SITE BRICK PAVING ON CAMPUS

SEE DETAIL B1/A-501

8 CONCRETE LANDING, RAMP, & STAIRS SEE

D1/A-401

9 CONCRET PARKING CURB

10 VAN ACCESSIBLE HANDICAP PARKING

SPACES WITH SIGNAGE

11 HANDICAP ACCESSIBLE PARKING SIGN

myazzie

FRANK

UP

STORAGE

STORAGE CLOSET

CLASSROOM

RESTROOM

CLASSROOM

CLASSROOM

OFFICE

103A

344 2

23' - 11" 18' - 2" 42' - 2"

/2

39' - 0"

GENERAL NOTES

A. PHOTOS SHOW EXISTING LAYOUTS, CONTRACTOR

RESPONSIBLE FOR ALL ITEMS TO COMPLETE WORK,

SHOWN OR NOT

B. CONTRACTOR TO DOCUMENT LOCATION OF ALL

EQUPMENT TO BE REINSTALLED

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

AD100

B L

D G

O

V E

R A

L L

D E

M O

. F L

O O

R P

L A

N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

D

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

3/16" = 1'-0" A2

BUILDING 112 - OVERALL DEMOLITION FLOOR PLAN

KEYED NOTES

1 ABATE & REMOVE FLOOR TILE, BASE AND ADHESIVE.

PREPARE FLOOR FOR INSTALLATION OF NEW TILE

2 REMOVE WALL COMPLETELY, RELOCATE ANY ITEMS

ON WALL TO ADJACENT LOCATION. REFER TO SHEET

A101.

3 REMOVE DOOR & FRAME ASSOCIATED HARDWARE

COMPLETELY, INFILL WALL

4 REMOVE WALL FOR NEW DOOR. SEE DOOR

SCHEDULE ON SHEET A601 FOR SIZE

5 REMOVE TOILET PARTITIONS, PATCH WALL @

ATTACHMENTS

6 REMOVE PLUMBING FIXTURES, SEE PLUMBING FOR

PIPING DEMOLITION

7 REMOVE ALL EQUIPMENT & FURNISHING, RETURN TO

UNIVERSITY

8 REMOVE SLAB & FOUNDATION, TO GRADE

9 REMOVE STEPS AND HANDRAIL

10 REMOVE HANDRAIL

11 PROTECT MURAL DURING CONSTRUCTION

12 REMOVE CHALK BOARD AND RETURN TO UNIVERSITY

13 REMOVE CARPET

14 REMOVE DOWNSPOUT, PATCH GUTTER AND HOLD

FOR REINSTALLATION

15 REMOVE ROLL-UP DOOR FRAME AND HARDWARE

16 REMOVE EXISTING STOREFRONT & DOOR. PREP

OPENING FOR NEW SYSTEM

17 REMOVE DOOR & FRAME, ASSOCIATED HARDWARE.

PREP OPENING FOR NEW DOOR & FRAME

18 REMOVE HVAC EQUIPMENT, SEE MECHANICAL

19 REMOVE ACOUSTIC CEILING TILES, GRID TO REMAIN

20 REMOVE ALL FLOOR & WALL TILE & PREP WALLS FOR

NEW TILE INSTALLATION

21 REMOVE ASPHALT PAVING THE WIDTH OF THE NEW

STAIR TO THE DRAINAGE SWALE NEAR THE

DRIVEWAYAND 5' WEST OF NEW RAMP

22 REMOVE DOOR & FRAME ASSOCIATED HARDWARE

COMPLETELY

23 REMOVE ALL FURNITURE, CASEWORK, SHELVING,

AND ASSOCIATED ITEMS. STORE ITEMS WHERE

DIRECTED BY HASKELL UNIVERSITY

24 SCRAPE FLOOR & PATCH & REPAIR AS NEEDED FOR

NEW FLOORING

1/64" = 1'-0" A5

KEY PLAN

SCALE: 3/16" = 1'-0"

0' 2' 8' 12'4'

N

GENERAL NOTES

A. PHOTOS SHOW EXISTING LAYOUTS, CONTRACTOR

RESPONSIBLE FOR ALL ITEMS TO COMPLETE WORK,

SHOWN OR NOT

B. CONTRACTOR TO DOCUMENT LOCATION OF ALL

EQUPMENT TO BE REINSTALLED

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :0

P

M

A s in d ic at ed

AD101

B L

D G

D

E M

O . P

H O

T O

S A

N D

D E

T A

IL

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

D

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

KEYED NOTES

1 REMOVE DOOR & FRAME ASSOCIATED HARDWARE

COMPLETELY, INFILL WALL

2 ABATE & REMOVE FLOOR TILE, BASE AND ADHESIVE.

PREPARE FLOOR FOR INSTALLATION OF NEW TILE

3 REMOVE PLUMBING FIXTURES, SEE PLUMBING FOR

PIPING DEMOLITION

4 REMOVE TOILET PARTITIONS, PATCH WALL @

ATTACHMENTS

5 REMOVE ALL EQUIPMENT & FURNISHING, RETURN TO

UNIVERSITY

6 REMOVE STEPS AND HANDRAIL

7 REMOVE HANDRAIL

8 REMOVE SLAB & FOUNDATION, TO GRADE

9 REMOVE DOWNSPOUT, PATCH GUTTER AND HOLD

FOR REINSTALLATION

10 REMOVE STOREFRONT GLAZING, DOORS, AND FRAME

11 REMOVE ASPHALT PAVING THE WIDTH OF THE NEW

STAIR TO THE DRAINAGE SWALE NEAR THE

DRIVEWAYAND 5' WEST OF NEW RAMP

12 REMOVE WALL TILE, PATCH WALL FOR NEW TILE

13 REMOVE ALL FURNITURE, CASEWORK, SHELVING,

AND ASSOCIATED ITEMS. STORE ITEMS WHERE

DIRECTED BY HASKELL UNIVERSITY

14 REMOVE CARPET

12" = 1'-0" C2

HALL 102A

12" = 1'-0" A2

EXISTING RESTROOM - NORTH EAST

12" = 1'-0" C3

CLASSROOM 103

12" = 1'-0" B3

EXISTING RESTROOM - NORTH WEST

12" = 1'-0" A3

ENTRY TO CLASSROOM 110

12" = 1'-0" B4

OFFICE 103A

12" = 1'-0" A4

CLASSROOM 105

GENERAL NOTES

A. PHOTOS SHOW EXISTING LAYOUTS, CONTRACTOR

RESPONSIBLE FOR ALL ITEMS TO COMPLETE WORK,

SHOWN OR NOT

B. CONTRACTOR TO DOCUMENT LOCATION OF ALL

EQUPMENT TO BE REINSTALLED

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :0

P

M

A s in d ic at ed

AD102

B L

D G

D

E M

O . R

E F

L . C

E

IL

IN

G

P L

A N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

D

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

3/16" = 1'-0" A2

DEMOLITION REFLECTED CEILING PLAN

N

SCALE: 3/16" = 1'-0"

0' 2' 8' 12'4'

KEYED NOTES

1 REMOVE THE GYPSUM BOARD CEILING SYSTEM

2 REMOVE SKYLIGHT DIFFUSER & INNER SKYLIGHT

LINING. FRAMING TO REMAIN. DO NOT DISTURB

ROOFING OR SKYLIGHT LENS

3 REMOVE CEILING OPENING DUCTING & FRAME WORK

TO DECK

4 REMOVE ALL EXISTING LIGHTING FIXTURES, SEE

ELEC

5 LIGHTING TO BE REMOVED, SEE ELECTRICAL

6 REMOVE WALL COMPLETELY, RELOCATE AND ITEMS

ON WALL TO ADJACENT LOCATION, REFER TO SHEET

A101

12" = 1'-0" C1

LECTURE HALL 110 - NORTH

12" = 1'-0" B1

LECTURE HALL 110 - EAST

1/64" = 1'-0" A5

KEY PLAN

8" 23' - 3" 8" 17' - 6" 8" 42' - 2" 8"

70 seats

+6" A.F.F

+12" A.F.F.

67 SF

MECHANICAL

110A

76 SF

VESTIBULE

110B

153 SF

STORAGE

109A

97 SF

STORAGE

39 SF

JANITOR

104C

+6"+12"

+18" A.F.F

+18"

17' - 6"

18' - 2"

9' - 0"

23' - 3"

/2

66 SF

MEN

104B 112 SF

WOMEN

104A

S

F

L E

C T

U R

E H

A L L

A-101

A1

A-102

C1

D A

D C

D

D A

D B

16' - 0"

A-401

D1

A-100

A1

D109A

A AA

C D

B

W1

STORAGE

CLASSROOM

OFFICE

OFFICE

103A

HALL

102A

1/4" / 12"

C3

A-501

STORAGE

STORAGE

CLASSROOM

OFFICE

HALL

102A

OFFICE

103A

GENERAL NOTES

A. SEE SHEET A-501 FOR WALL TYPES

1/8" = 1'-0" B3

BUILDING 112 - OVERALL NEW WORK PLAN

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

A-100

B L

D G

O V

E R

A L

L N

E W

W O

R K

P L

A N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-1

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

N

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16' 1/4" = 1'-0" A3

CANOPY ROOF PLAN

N

KEYED NOTES

1 60 MIL TPO MEMBRANE ROOF OVER SLOPED

INSULATION (1/4" PER 1'-0") & RECOVERY BOARD

OVER STEEL DECK

2 TPO MEMBRANE LINED GUTTER, SEE DETAIL

C3/A501

3 6" X 6" DROP TO PREFORMED METAL GUTTER

4 INSTALL VCT TILE & BASE, SEE FINISH SCHEDULE

5 PATCH & REPAIR ADJACENT SURFACES AS

NECESSARY

6 INSTALL CARPET & BASE, SEE FINISH SCHEDULE

7 INSTALL SUSPENDED ACOUTIC CEILING

TILES,REPAIR & REPAINT GRID AS NEEDED TO

LOOK NEW

8 (2) WHITEBOARD 6' LONG X 4' TALL

9 PAINT ALL WALLS

10 HOLLOW STEEL TUBE, SEE STRUCTURAL

SCALE: 1/8" = 1'-0"

0' 4' 8' 16' 32'

3/16" = 1'-0" A1

ROOM 102A, 103, 103A, 105, & 108 FLOOR PLAN

1/64" = 1'-0" A5

KEY PLAN

SCALE: 3/16" = 1'-0"

0' 2' 8' 12'4'

S S

S S

S S

S S

C

C

DN VESTIBULE

110B

STORAGE

109A MECHANICAL

110A

LECTURE HALL

9' - 0"

12' - 0"

8' - 0"

1010' - 0"

10' - 6"

10' - 6"

10' - 6"

10' - 6"

8' - 8 1/2"

7' - 0"

B4

A-601

TYP

B3

A-501

TYP.

4' - 0"

24 24

4' - 10"

A4

A-501

Sim

A-401

C3

A-401

VESTIBULE

110B

MECHANICAL

110ASTORAGE

109A

LECTURE HALL

A-401

B3

B1

A-401A1

A-401

A3

D

D A

D C

A-401C2 A-401 C1

6' - 5 1/2" 6' - 5 1/2" 6' - 5 1/2"

C L E

A R

1' - 6" 1' - 0" 0' - 6" 0' - 0"

1' - 6" 1' - 0" 0' - 6" 0' - 0"

A.F.F.A.F.F.A.F.F.A.F.F.

A.F.F.A.F.F.A.F.F.A.F.F.

1818 18

18 18 18

SLOPE 1"/12" MAX

D109A

W1

A-401

D1

D B

39' - 0"

/2

6' - 1"

3' - 11 1/2" 3' - 11 1/2"

4' - 0" 4' - 0"

3' - 11 1/2"

RCP SYMBOL LEGEND

10'-0" SOFFIT OR CEILING HEIGHT A.F.F.

FLOURESCENT LIGHT FIXTURE

DOWNLIGHT FIXTURE

SUPPLY AIR DIFFUSER

RETURN AIR GRILL

ACOUSTICAL LAY-IN CEILING PANELS

GYPSUM BOARD CEILNG

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

A-101

B L

D G

F

L O

O R

R

E F

L . C

E

IL

IN

G

P L

A N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-1

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

3/16" = 1'-0" A3

REFLECTED CEILING PLAN

3/16" = 1'-0"

A1

ROOM110 PLAN

N N

SCALE: 3/16" = 1'-0"

0' 2' 8' 12'4'

SCALE: 3/16" = 1'-0"

0' 2' 8' 12'4'

KEYED NOTES

1 SUSPENDED ACOUSTICAL LAY-IN CEILING.SEE

SCHEDULE ON SHEET A-602

2 SUSPENDED GYPSUM BOARD CEILING.

3 EXISTING SKYLIGHT. PATCH, TEXTURE & PAINT

TO MATCH LECTURE HALL WALLS. INSTALL

HORIZONTAL SHADES ABOVE DIFFUSER.

4 COMPUTER TABLE. SEE FURNITURE

SCHEDULE SHEET A-602

5 INSTALL NEW CHAIRS AT COMPUTER TABLES.

SEE FURNITURE SCHEDULE SHEET A-602

6 STOREFRONT SYSTEM & ADA COMPLIANT

DOORS.

7 INFILL DOOR WITH CMU, FINISH TO MATCH

ADJACENT WALL

8 NEW WALL, SEE SHEET A-100 FOR WALL TYPES

9 GYPSUM BOARD SUSPENDED CEILING OVER

FURRING CHANNELS

10 OPEN TO STRUCTURE ABOVE

11 CEILING MOUNTED PROJECTION SCREEN

12 SMART BOARD MOUNTED TO WALL. SEE

ELECTRICAL AND FURNITURE SCHEDULE ON

SHEET A-602

13 WHITE BOARD MOUNTED TO WALL. SEE

FURNITURE SCHEDULE ON SHEET A-602

14 SMART PODIUM. REFER TO ELECTRICAL AND

FURNITURE SCHEDULE ON SHEET A-602

15 TEXTURE, PRIME, AND PAINT ENTIRE WALL.

SEE SCHEDULE SHEET A-602

16 ADA WALK-OFF MAT. REFER TO FURNITURE

SCHEDULE.

17 EXISTING WALL TO REMAIN.

18 ELEVATED SEATING LEVEL, SEE STRUCTURAL

DETAILS

19 EXTERIOR GYPSUM BOARD SOFFIT CEILING

20 CEILING PROJECTOR

21 STEEL COLUMN, SEE STRUCTURAL

22 ACOUSTICALLY SEAL EXISTING WALLS AT

DECK, & OPENINGS WITH ACOUSTICAL

SEALANT

23 STEEL TUBE, SEE STRUCTURAL, PAINT

24 SPEAKERS SEE ELECTRICAL

25 PERIMETER SOFFIT, SEE DETAIL B3/A-501

26 PROVIDE HANDRAIL 2 1/4" MIN. CLEARANCE TO

WALL

1/64" = 1'-0"

JANITOR

104C

WOMEN

104A

MEN

104B

A-102 B1

A-102B4

A-102 C5

B3

A1

A2

A3

B2

D

B

D A

1' - 3 1/2"

8' - 0 1/2"

1' - 4 1/2"

8' - 1" 4"

8' - 1"

5' - 2" 2' - 11"

1' - 6" 1' - 6"

1' - 8 1/2"

D1

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

4 5

FIN. FLR.

0' - 0"

FIN. FLR.

0' - 0"

SEMI-RECESSED

PAPER TOWEL

DISPENSER/

WASTE

RECEPTACLE

SURFACE

MOUNTED

SOAP

DISPENSER

SURFACE

MOUNTED

SEAT COVER

DISPENSER

SURFACE MOUNTED

DOUBLE ROLL TOILET

TISSUE HOLDER

18"

VERTICAL

GRAB BAR

BARRIER FREE

TOILET

42"

HORIZONTAL

GRAB BAR

NOTE:

PROVIDE BACKING AT

GRAB BAR ANCHOR LOCATIONS

AND ALL WALL MOUNTED

ACCESSORIES

36"

HORIZONTAL

GRAB BAR

SEMI-RECESSED

SANITARY

NAPKIN/TAMPON

DISPENSER

(TO TOP OF

OPERATOR)

SURFACE MOUNTED

SANITARY

NAPKIN/TAMPON

RECEPTACLE

BARRIER FREE

WALL MOUNT

URINAL

TOILET

PARTITION

MOP HOLDER/

UTILITY SHELF

NOTE:

COVER ALL EXPOSED

DRAIN PIPES AND

WATER LINES.

TO FINISH

MAX

1' - 6"

3' - 6"

MAX

1' - 0"

TO FINISH

MIN

1' - 0"

MIN

2' - 0"

M

IN

MAX

9"

M

IN

TO FINISH TO FINISH TO FINISH TO FINISH

TO FINISH

M A

X

M A

X

M A

X

1' - 10"

1' - 3"

MIRROR

M A

X

B .O

M

IR

R

O R

M A

X

SINK HEIGHT

M

IN

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

A-102

B L

D G

E

N L

A R

G E

D P

L A

N

E L

E V

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-1

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

3/8" = 1'-0" C1

ENLARGED RESTROOMS

3/8" = 1'-0" B1

MENS RM 104B - EAST

3/8" = 1'-0"

B2

MENS RM 104B - SOUTH

3/8" = 1'-0" B3

MENS RM 104B - NORTH

3/8" = 1'-0"

B4

WOMENS RM104A - WEST

3/8" = 1'-0" A1

WOMENS RM 104A - NORTH

3/8" = 1'-0"

A2

WOMENS RM 104A - EAST

3/8" = 1'-0" A3

WOMENS RM 104A - SOUTH

3/8" = 1'-0" C5

JANITOR RM 104C - EAST

N

1/4" = 1'-0" C2

ADA ACCESSIBLE MOUNTING HEIGHTS

KEYED NOTES

1 24" x 36" MIRROR IN 1/2" STAINLESS

STEEL FRAME

2 18" VERTICAL GRAB BAR

3 36" HORIZONTAL GRAB BAR

4 42" HORIZONTAL GRAB BAR

5 TOILET PAPER HOLDER

6 TOILET SEAT COVERS AND DISPENSER.

7 SANITARY NAPKINS DISPOSAL

8 TOILET PARTITION

9 SEMI-RECESSED PAPER TOWEL

DISPENSER & WASTE RECPTACLE

10 SOAP DISPENSER

11 FINISH AS SCHEDULED

12 MOP BASIN, SEE PLUMBING

13 WALL TILE 12 X 12 FIELD COLOR

14 WALL TILE ACCENT COLOR 1

15 WALL TILE ACCENT COLOR 2

16 FLOOR DRAIN, SEE MECHANICAL

17 WALL HUNG LAVATORY, SEE PLUMBING

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

SCALE: 3/8" = 1'-0"

0' 2' 8'4' 6'

1/64" = 1'-0"

FIN. FLR.

0' - 0"

SOFFIT

10' - 6"

10' - 0"8"10' - 0"1' - 0"

/2

FIN. FLR.

0' - 0"

1 2

SOFFIT

10' - 6"

(BEHIND)

8' - 0"

8' - 0"

FIN. FLR.

0' - 0"

SOFFIT

10' - 6"

2' - 0" 10' - 0" 2' - 0" 10' - 0" 2' - 7" 10' - 0" 2' - 0" 10' - 0" 2' - 0"

/2

6 666

7 7

FIN. FLR.

0' - 0"

SOFFIT

10' - 6"

5 5 3

1' - 6"10' - 0"2' - 0"10' - 0"1' - 1"10' - 0"1' - 6"

6 6 6

A-401C2

A-401 C1

16' - 0"

1' - 0"

/2

/2

14' - 8"

/2

/2

A-401

C3

15 1515

FIN. FLR.

0' - 0"

GRADE

-1' - 4"

A-FP09

8' - 8 1/2"

1' - 6 1/2"4' - 0" 1' - 8"

FIN. FLR.

0' - 0"

GRADE

-1' - 4"

A-FP09

8' - 8 1/2"

3' - 2" 3' - 2" 1' - 6" 4' - 1 1/2"

R

2T @11" = 22"

FIN. FLR.

0' - 0"

GRADE

-1' - 4"

A-FP09

8' - 8 1/2"

1' - 0"

6' - 0" 6' - 0" 6' - 1 1/2"

1"

12"

9 7

/2

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

/4

'-0

A-401

B L

D G

IN

T . E

L E

V A

T

IO

N S

D

E T

A

IL

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-4

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

1/4" = 1'-0" B3

LECTURE HALL RM 110 - NORTH

1/4" = 1'-0"

B1

LECTURE HALL RM 110 - EAST

1/4" = 1'-0" A1

LECTURE HALL RM 110 - WEST

1/4" = 1'-0"

A3

LECTURE HALL RM 110 - SOUTH

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0" D1

ENLARGED CANOPY PLAN

N

1/4" = 1'-0" C1

CANOPY EAST ELEVATION

1/4" = 1'-0"

C2

CANOPY WEST ELEVATION

1/4" = 1'-0" C3

CANOPY NORTH ELEVATION

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

KEYED NOTES

8 STRUCTURAL STEEL TUBE, SEE STUCTURAL.

9 CONCRETE ENCASED COLUMN, SMOOTH FINISH,

CLEAR SEALANT

10 CONCRETE LANDING, SEE STRUCTURAL

11 CONCRETE STEPS AND LANDING, SEE STRUC

12 CONCRETE RAMP, MAX 1:12 SLOPE, SEE

STRUCTURAL

13 ALUMINUM STOREFRONT, SEE PLAN

14 STEEL TUBE CANOPY, SEE DETAIL A3/A100, SEE

ALSO STUCTURAL, PAINT

15 BRICK PAVERS TO MATCH TYPE AND COLOR OF

SIMILAR SITE BRICK PAVING EXISTING ON CAMPUS

SEE DETAIL B1/A-501

16 METAL COPING

17 TACTILE EXIT SIGN SEE SPECIFICATION

KEYED NOTES

1 SMART BOARD MOUNTED TO WALL. SEE

ELECTRICAL AND FURNITURE SCHEDULE ON SHEET

A-602

2 WHITE BOARD MOUNTED TO WALL. SEE FURNITURE

SCHEDULE ON SHEET A-602

3 CEILING MOUNTED PROJECTION SCREEN

4 ELEVATED SEATING LEVEL, SEE STRUCTURAL

DETAILS

5 PROVIDE RUBBER TREAD NOSING AT INTERIOR

STEPS, TYP.

6 ACOUSTICAL WALL PANEL, 2" THICK, MIN NRC 1.15.

ABUSE RESISTANT WITH HALF BEVEL EDGE

7 1 1/2" O.D. STEEL PIPE HANDRAIL, PAINTED

REFERENCE ASCE 7-05

NOTES:

1. HANGER WIRES MUST BE 12 GA. IN.

SOFT ANNEALED, MILD STEEL WIRE.

WIRES SHALL BE WRAPPED TIGHTLY

RUNNERS AND SUPPORTS WITH A

MIN. OF THREE TURNS.

2. CLIPS SHALL HOLD RUNNERS

TIGHTLY TOGETHER. SPLICE CLIPS

SHALL BE CAPABLE OF RESISTING

AT LEAST 50 LBS IN TENSION OR

COMPRESSION.

3. FOR MANUFACTURED SYSTEMS,

SUBMIT SUBSTANTIATION IN

ACCORDANCE WITH IBC

STANDARDS.

4. RUNNERS SHALL BE CAPABLE OF

SUPPORTING CEILING SYSTEM WITH

DEFLECTIONS LESS THAN 0.133

INCHES.

5. LOCAL KINKS AND BENDS SHALL NOT

BE MADE HANGER WIRES FOR

LEVELING.

6. ALL SUSPENDED SYSTEMS SHALL BE

HUNG IN A SIMILAR FASHION,

INCLUDING, BUT NOT LIMITED

TO, DUCTWORK, LIGHT FIXTURES,

AND PIPING.

VERTICAL STRUT - 16 GA,

1 1/2" x 1/2" CRC @ CENTER

OF SEISMIC HANGER WIRES

TO DECK ABOVE

VERTICAL HANGER WIRES @

4'-0" EACH WAY AND 8" FROM

WALL, TYP.

IF HANGERS MUST BE SPLAYED

MORE THAN 1 IN 6 OUT OF

PLUMB PROVIDE

CONUTERSLOPED HANGER.

SEISMIC HANGER WIRES SHALL

BE SPLAYED AT 45° DEGREES FROM

MAIN RUNNER IN EACH DIRECTION,

AND 45° DEGREES FROM CROSS

RUNNER IN EACH DIRECTION AT

12'-0" MAX. EACH WAY AND 6'-0" MAX.

FROM WALLS, TYP.

DO NOT BEND WIRE

AROUND INTERFERING

EQUIPMENT. PROVIDE

1 1/4" CHANNEL TRAPEZE

WITH TWO (MIN.) HANGER

WIRES.

45° 45°

45°45°

SEISMIC BRACING DETAIL

SCALE: N.T.S.

1/4" / 12"

1/4" / 12"

FIN. FLR.

0' - 0"

A

FIN. FLR.

0' - 0"

B

HALL

JANITOR

FIN. FLR.

0' - 0"

SEE PLAN

4 4

C

SIDEWALK SECTION

12 13

1% CROSS SLOPE

EXPANSION JOINT

R=1/8"

FIN. FLR.

0' - 0"

D

1-HR RATED

WALL/CEILING

SOFFIT

10' - 6"

CEILING

12' - 0"

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

A-501

B L

D G

D

E T

A

IL

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-5

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

1 1/2" = 1'-0" C3

SECTION DETAIL @ CANOPY

3/4" = 1'-0" A1

WALL @ STORAGE & MECH.

3/4" = 1'-0"

A2

WALL @ JANITOR

3/4" = 1'-0" A3

PLUMBING WALL

KEYED NOTES

1 NEW WALL, SEE SHEET A-100 FOR WALL TYPES

3 5/8" GYPSUM BOARD TYPE 'X'.

4 4" METAL STUD.

5 SCHEDULED CEILING. REFER TO REFLECTED CEILING

PLAN A-101.

6 SOUND ATTENUATION BATT INSULATION.

7 VINYL BASE

8 5/8" WATER RESISTIVE GYPSUM BOARD.

9 8" METAL STUD WALL

10 BRICK PAVERS

11 PROVIDE 1/2" EXPANSION JOINT WHEN ABUTTING TO

EXISTING CONCRETE PAVEMENT

12 4" SAND BASE COURSE

13 PREPARED SUBGRADE - SCARIFY AND COMPACT TO

95% DENSITY PER ASTM D-1557

14 PREMOLDED EXP. JOINT FILLER -TRAFFIC RATED

15 EXISTING CONCRETE OR ASPHALT

16 EXISTING DECK

17 3 LAYERS 5/8" TYPE "X" GYPSUM BOARD WITH

STAGGERED JOINTS

18 3 5/8" METAL STUD CEILING FRAMING

19 STEEL SUPPORT AT OPENING, SEE STUCTURAL

20 STRUCTURAL STEEL TUBES, SEE STUCTURAL

DRAWINGS FOR SIZE AND LOCATION.PAINT SEE

COLOR LEGEND ON SHEET A-601

21 SUSPENDED EXTERIOR GYP. BOARD CEILING, SEE

COLOR LEGEND ON SHEET A-601

22 LIGHTING FIXTURE, SEE ELECTRICAL

23 SHEET METAL GUTTER SYSTEM

24 RECOVERY BOARD OVER METAL DECK

25 MEMBRANE ROOFING

26 TAPERED RIGID INSULATION

27 EXISTING CMU

28 3 5/8" METAL STUDS

29 SUSPENDED ACOUSTICAL LAY-IN CEILING.SEE

SCHEDULE ON SHEET A-602

30 EXISTING RIGID INSULATION AND ROOFING

31 EXISTING ROOF DECK

32 METAL COPING

SCALE: 1 1/2" = 1'-0"

1' 9" 3" 0 1'6"

SCALE: 3/4" = 1'-0"

0' 1' 2' 3'

1 1/2" = 1'-0" B1

SIDEWALK SECTION @ 110 ENTRY

1 1/2" = 1'-0"

B2

EXPANSION JOINT DETAIL

3/4" = 1'-0" A4

LECTURE HALL WALL

1" = 1'-0" B3

TYPICAL SOFFIT DETAIL

4" 2' - 4" 4"1' - 10" 8" 6"

AS SCHED.

A S

S C

H E

D U

L E

D

D1 D2 D3

T

T

2" AS SCHED. 2"

A S

S C

H E

D U

L E

D

2" AS SCHED. 2"

A S

S C

H E

D U

L E

D

2" AS SCHEDULED 2"

A S

S C

H E

D U

L E

D

2" 2' - 10" 2"

AS SCHEDULED 2"

9' - 4"

" 1

A S

S C

H E

D U

L E

D

F1 F2 F3 F4

T

T

T T

" 1

2" 2' - 8" 2"

3' - 0"

FIN. FL.

W1

T

T

T

8"

6"

8" STUDS

10 1/8" @

2"

/8

S

T U

D S

FIN. FL.

10 10

151 5

2"

12 12

18 18

5 1/2"

F

IE

L D

V E

R

IF

Y D

IS

T

A N

C E

12 12

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A s in d ic at ed

A-601

B L

D G

D

O O

R /W

IN

D

O W

S C

H E

D U

L E

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-6

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

1/4" = 1'-0" C1

DOOR TYPES

1/4" = 1'-0" B1

FRAME TYPES

1/4" = 1'-0" C2

WINDOW TYPE

1 1/2" = 1'-0" D3

CMU HEAD DETAIL

1 1/2" = 1'-0"

D4

TYP. HEAD DETAIL

1 1/2" = 1'-0" C4

TYP. JAMB DETAIL

1 1/2" = 1'-0" B3

STOREFRONT HEAD DETAIL

1 1/2" = 1'-0" A3

STOREFRONT SILL DETAIL

1 1/2" = 1'-0"

A1

STOREFRONT JAMB DETAIL

KEYED NOTES

1 EXISTING CMU

2 BACKER ROD & SEALANT ON BOTH SIDES

3 HOLLOW METAL FRAME

4 3 5/8" METAL STUDS

5 SEALANT ON BOTH SIDES

6 5/8" GYPSUM BOARD TYPE 'X'.

7 METAL BOX HEADER

8 FRAME ANCHOR

9 ALUMINUM STOREFRONT

10 GLAZING

11 FINISH AS SCHEDULED

12 EXISTING SKYLIGHT AND CURB

13 EXISTING RIGID INSULATION AND ROOFING

14 EXISTING ROOF DECK

15 EXISTING HAT CHANNEL FURRING

16 5/8" GYPSUM BOARD FINISH IN SKYLIGHT WELL

AND SKYLIGHT SOFFIT

17 MOTORIZED SKYLIGHT BLACKOUT SHADE, INSTALL

PER MANUFACTURER

18 ACOUSTICAL LAY-IN CEILING

19 GROUT SOLID, TYP AT JAMBS IN CMU

20 ALUMINUM THRESHOLD

1 1/2" = 1'-0" C3

CMU JAMB DETAIL

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

SCALE: 1 1/2" = 1'-0"

1' 9" 3" 0 1'6"

1" = 1'-0" B4

SKYLIGHT SECTION

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

P

B

IA

\0 W

\D e s ig n \B

IM

\B

U

IL

D

IN

G

\L

O C

A L

F

IL

E S

\H A

S K

E L

L A

R C

H C

E N

T R

A L

K

H a rr is .r v t

/9

/2

:1 :5

P

M

A-602

E Q

U

IP

M E

N T

F

U R

N

IT

U R

E S

C H

E D

U L

E S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

W F

K H

F F

P

7W A

-6

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

FINISH ABBREVIATIONS

ACT ACOUSTICAL CEILING TILE

EXP EXPOSED

EPXY EPOXY FLOOR

FRP FIBERGLASS REINFORCED PLASTIC PANELS

PT PAINTED GYPSUM BOARD

VINYL VINYL BASE

S. CONC SEAL CONCRETE

CT CERAMIC TILE

EPT EPOXY MOISTURE RESISTANT PAINT

CPT CARPET TILE

EM ENTRY MAT

ROOM FINISH SCHEDULE

ROOM NO ROOM NAME FLOOR BASE

WALLS CEILING

NOTESN S E W MATL

102A HALL

103 OFFICE

103A OFFICE

104A WOMEN CT CT CWT CWT CWT CWT EPT

104B MEN CT CT CWT CWT CWT CWT EPT

104C JANITOR EPXY FRP FRP FRP FRP FRP EXP

105 CLASSROOM CPT VINYL PT PT PT PT ACT

108 STORAGE

109 STORAGE VCT VINYL PT PT PT PT EXP

109A STORAGE VCT VINYL PT PT PT PT EXP

110 LECTURE HALL CPT VINYL PT PT PT PT ACT ACOUSTICAL WALL PANELS

110A MECHANICAL EPXY VINYL PT PT PT PT EXP

110B VESTIBULE VCT/EM VINYL PT PT PT PT PT

DOOR AND FRAME SCHEDULE

MARK

DOOR

DOOR

MATERIAL

FRAME FRAME FRAME FRAME FRAME

FIRE

RATING HARDWARE NOTESTYPE

SIZE SIZE SIZE

MATL TYPE

DETAIL DETAIL DETAIL

W HT THK JAMB HEAD SILL

D104A D1 3' - 0" 7' - 0" 0' - 1 3/4" HM HM F2 C3/A601 D3/A601 45 SEE SPEC

D104B D1 3' - 0" 7' - 0" 0' - 1 3/4" HM HM F2 C3/A601 D3/A601 45 SEE SPEC

D104C D1 3' - 0" 7' - 0" 0' - 1 3/4" HM HM F2 C3/A601 D3/A601 45 SEE SPEC

D109A D1 3' - 0" 7' - 0" 0' - 1 3/4" HM HM F1 C4/A601 D4/A601 SEE SPEC

D110 D2 3' - 0" 7' - 0" 0' - 1 3/4" HM HM F1 C4/A601 D4/A601 45 SEE SPEC SOUND SEAL

D110A D1-(2) 6' - 0" 7' - 0" 0' - 1 3/4" HM HM F3 C4/A601 D4/A601 SEE SPEC SOUND SEAL

D110B D3-(2) 6' - 0" 7' - 0" 0' - 1 3/4" AL AL F4 A1/A601 B3/A601 A3/A601 SEE SPEC SOUND SEAL

D110C D3-(2) 6' - 0" 7' - 0" 0' - 1 3/4" AL AL F4 A1/A601 B3/A601 A3/A601 SEE SPEC

FINISH MATERIALS AND COLORS

CEILINGS:

- CEILING GRID PAINT WHITE ENAMEL PAINT

- CEILING ACOUSTICAL TILES ARMSTRONG

RANDOM FISSURED TEXTURED

2'X4' PANEL

COLOR: WHITE

FLOORS:

- VINYL COMPOSITION TILE (VCT) ARMSTRONG T3513

- VINYL BASE JOHNSONITE

TRADITIONAL WALL BASE

COLOR: 129 SILK WB

- CARPET TILE BUILDING 112, ROOM 110

SHAW CONTRACT GROUP

WISDOM 60709

COLOR: 09900 MAJESTIC PURPLE

WALLS:

- INTERIOR PAINT SHERWIN- WILLIAMS

COLOR: NAVAJO WHITE SW 6126

- DECORATIVE ACOUSTICAL WALL PANEL BUILDING 112, ROOM 110

ACOUSTICAL SURFACES INC.

NOISE S.T.O.P. FIBRISORB

COLOR: DEEP BURGANDY

- PORCELAIN TILE: BUILDING 112, RESTROOMS

- FIELD TILE (WALLS & FLOORS) COLOR: DAL TILE PERSIAN GOLD CS54

- ACCENT TILE 1 COLOR: DAL TILE INDIAN RED CS51

- ACCENT TILE 2 COLOR: DAL TILE TUSCAN BLUE CS56

EXTERIOR:

- EXTERIOR PAINT SHERWIN- WILLIAMS

EXTERIOR ENAMEL

COLOR: IZMIR PURPLE SW 6825

(4 ACCESSIBLE TABLES)

DOMESTIC COLD WATER PIPING (CW)

DOMESTIC HOT WATER PIPING (HW)

HOT WATER CIRCULATING PIPING (HWR)

G GAS PIPING

DS DOMESTIC SOFT WATER

RO REVERSE OSMOSS WATER PIPING

C CONDENSATE PIPING

S SANITARY WASTE PIPING

SANITARY VENT PIPING

RD ROOF DRAIN PIPING

V

SD STORM DRAIN PIPING

AW ACID WASTE PIPING

AV ACID VENT PIPING

FP FIRE PROTECTION PIPING

PLUMBING PIPING TO BE REMOVED

POINT OF CONNECTION/DISCONNECT

NOTE; NOT ALL SYMBOLS ARE USED

(E) EXISTING PIPING/EQUIPMENT

PIPING DROP

A. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE

NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS. IT

IS INTENDED THAT A COMPLETE PLUMBING SYSTEM BE

PROVIDED WITH ALL NECESSARY EQUIPMENT,

APPURTENANCES, AND CONTROLS COMPLETELY

COORDINATED WITH ALL DISCIPLINES. ALL PARAMETERS

GIVEN IN THESE DOCUMENTS SHALL BE STRICTLY

CONFORMED TO ANY ITEMS AND LABOR REQUIRED FOR

A COMPLETE PLUMBING SYSTEM IN ACCORDANCE WITH

ALL APPLICABLE CODES, STANDARDS, LOCAL

AUTHORITIES, AND THESE CONTRACT DOCUMENTS

SHALL BE FURNISHED WITHOUT INCURRING ANY

ADDITIONAL COST TO THE OWNER. CAREFULLY REVIEW

ALL CONTRACT DOCUMENTS AND THE DESIGN OF OTHER

TRADES.

B. COORDINATE ALL WORK WITH ARCHITECTURAL,

STRUCTURAL, FIRE PROTECTION, MECHANICAL AND

ELECTRICAL TRADES. PIPE ROUTING SHOWN IS

DIAGRAMMATIC. PROVIDE ALL OFFSETS, ETC., TO AVOID

INTERFERENCE WITH EQUIPMENT, PIPING, DUCTWORK,

LIGHTS, CONDUIT, ETC.

C. COORDINATE ALL FLOOR PENETRATIONS WITH

STRUCTURAL DRAWINGS, SET SLEEVES IN FLOORS AND

WALLS AND ATTACHMENTS FOR HANGERS AS

CONSTRUCTION PROGRESSES. ALL PENETRATIONS

MUST BE SEALED AND HELD AS TIGHT TO COLUMNS OR

WALLS AS POSSIBLE.

D. PROVIDE 24x24 OR 18x18 ACCESS PANELS (AS

REQUIRED) FOR WATER HAMMER ARRESTORS, ALL

VALVES LOCATED ABOVE NON-ACCESSIBLE CEILINGS

AND INSIDE PIPE CHASES. EXACT LOCATION MUST BE

COORDINATED WITH ARCHITECTURAL DRAWINGS AND

APPROVED BY ARCHITECT PRIOR TO INSTALLATION.

E. ALL DRAINAGE PIPING SHALL BE CONCEALED INSIDE

WALLS AND PIPE CHASES OR ABOVE CEILINGS. INSTALL

ALL PIPING ABOVE CEILING AS HIGH AS POSSIBLE.

F. WALL HYDRANTS AND HOSE BIBBS SHALL BE MOUNTED

24" ABOVE GRADE OR ABOVE FINISH FLOOR.

G. COORDINATE ALL UNDERGROUND PIPING WITH GRADE

BEAMS, WALL FOOTINGS AND OTHER STRUCTURAL

CONDITIONS.

H. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS

FOR LOCATION OF ALL PLUMBING FIXTURES. EXACT

LOCATION OF ALL PLUMBING FIXTURES MUST BE

VERIFIED IN FIELD PRIOR TO INSTALLATION. FINAL

LOCATION SHALL BE AS DIRECTED BY ARCHITECT.

I. DO NOT RUN PLUMBING, PIPING OR FIRE PROTECTION

PIPING THROUGH TRANSFORMER VAULTS, ELECTRICAL

CLOSETS, ELECTRICAL SWITCHGEAR ROOMS, OR

TELEPHONE ROOMS.

J. PROVIDE BASE CLEANOUT AT LOWEST FLOOR LEVEL OF

ALL SANITARY STACKS, WASTE STACKS, AND ROOF

DRAIN LEADERS. EXACT LOCATION OF WALL CLEANOUT

MUST BE COORDINATED AND ACCEPTED BY ARCHITECT

PRIOR TO INSTALLATION.

K. ALL MATERIALS IN AREAS EXPOSED TO WEATHER ARE

TO BE PAINTED WITH TWO COATS OF ZINC CHROMATE

PRIMER OR HOT DIP GALVANIZED.

L. ALL TRAPS TO FLOOR DRAINS AND FLOOR SINKS TO

HAVE APPROVED TRAP PRIMERS.

M. PRODUCTS, MANUFACTURERS AND MODEL NO.S FOR

EQUIPMENT INDICATE A BASIS FOR DESIGN BUT ARE NOT

LIMITED TO THE PRODUCTS SPECIFIED. SUBSTITUTION

OF PRODUCTS MUST COMPLY OR EXCEED THE

REQUIREMENTS DESIGNATED IN THE SPECIFICATIONS

AND DRAWINGS.

N. CLEANOUTS TO BE PROVDED AS INDICATED ON PLANS

AND AS REQUIRED BY CODE.

O. PLUMBING DESIGN AND INSTALLATION SHALL COMPLY

WITH UPC 2012.

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\P u b li c \D o c u m e n ts \H

A S

K E

L L

P

L U

M C

E N

T R

A L c a rn tz e n

.r v t

/5

/2

:2

:4

P

M

/8

'-0

P-001

P L

U M

B

IN

G N

O T

E S

A N

D L

E G

E N

D S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

M T

B

C G

A

M T

B

P

7W P

-0

PLUMBING SYMBOL LEGENDGENERAL PLUMBING NOTES

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

/0

/2

STORAGE

CLASSROOM

HALL

102A

LECTURE HALL

STORAGE

(E)WC

(E)UR

(E)LAV

(E)FD

222222

33 CAP

FURNACEFURNACE

(E)G(E)G(E)G

(E )G

(E)G

A. SEE SHEET P-001 FOR PLUMBING NOTES AND LEGEND.

GENERAL NOTES

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\P u b li c \D o c u m e n ts \H

A S

K E

L L

P

L U

M C

E N

T R

A L c a rn tz e n

.r v t

/5

/2

:2

:4

P

M

A s in d ic at ed

PD101

B L

D G

P

L U

M B

IN

G

D E

M O

L

IT

IO

N

P L

A N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

M T

B

C G

A

M T

B

P

7W P

D

1/4" = 1'-0" A1

BLDG 112 - PLUMBING DEMOLITION PLAN

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

N

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

KEYED NOTES

1 REMOVE EXISTING PLUMBING FIXTURES AND

ASSOCIATED CW, HW, WASTE AND VENT PIPING. CAP

PIPING AT MAINS.

2 DEMO EXISTING PIPING AS REQUIRED TO

ACCOMODATE NEW PLUMBING FIXTURE PIPING IN

NEW LOCATIONS. SEE SHEET P-101. FIELD

VERIFICATION OF EXISTING PIPING SIZES AND

LOCATION WILL BE REQUIRED.

3 EXISTING GAS LINE IN CRAWL SPACE TO REMAIN.

4 REMOVE EXISTING GAS LINE SERVING FURNACES

AND CAP GAS LINE AT MAIN.

5 FLOOR DRAIN TO REMAIN IN PLACE FOR REUSE.

6 REMOVE EXISTING CONDENSATE PIPING SERVING

FURNACE.

7 FIELD VERIFY AND REMOVE INACTIVE OR

ABANDONED PIPING OR APPURTENANCES IN THIS

ROOM. CAP INACTIVE/ABANDONED PIPING ABOVE

CEILING, BEHIND WALL OR BELOW FLOOR AND PATCH

SURFACES PER ARCHITECTURAL DIRECTION.

A5

KEY PLAN

/0

/2

WOMEN

104A

JANITOR

104C

CLASSROOM

LECTURE HALL

MEN

104B

HALL

102A

(E)FD

FD1

TYP.

11 TYP.

WCWC1

WC1

MB

U1

L1 L1

NOTE: SEE ISOMETRICS THIS

SHEET FOR PIPE SIZES AND

ADDITIONAL INFORMATION.

A. SEE SHEET P-001 FOR PLUMBING NOTES AND LEGEND.

B. SEE SHEET M-101 FOR LOCATION OF AIR HANDLER AHU-

1 AND FOR NOTING REGARDING THE AIR HANDLER'S

ASSOCIATED CONDENSATE DRAIN.

GENERAL NOTES

FD1

(E)FD

1 1/2"ø

2"ø

U1

MB

L1

L1

WC1

WC

1 1/2"ø 2"ø

2"ø

2"ø

2"ø

2"ø

3"ø

WOMEN

104A

MEN

104B

JANITOR

104C

1 1/2"ø

2"ø

3"ø

3"ø

3"ø

TYP.

2"ø

2"ø

2"ø

2"ø

2"ø

1"ø

1"ø

3/4"ø

3/4"ø

1"ø

3/4"ø

1/2"ø

1/2"ø

WC

WC1

MB

U1

WC1

L1

L1

WOMEN

104A

MEN

104B

JANITOR

104C

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\P u b li c \D o c u m e n ts \H

A S

K E

L L

P

L U

M C

E N

T R

A L c a rn tz e n

.r v t

/5

/2

:2

:4

P

M

A s in d ic at ed

P-101

B L

D G

P

L U

M B

IN

G

P L

A N

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

M T

B

C G

A

M T

B

P

7W P

-1

1/4" = 1'-0" C2

BLDG 112 - PLUMBING PLAN

KEYED NOTES

1 ROUTE NEW PLUMBING PIPING TO CONNECT TO EXISTING.

VERIFY EXISTING SIZE IS ADEQUATE PER CODE. FIELD

VERIFICATION OF EXISTING PIPING SIZES AND LOCATION

WILL BE REQUIRED.

2 ROUTE NEW PLUMBING PIPING TO CONNECT TO EXISTING.

VERIFY EXISTING SIZE IS ADEQUATE PER CODE. FIELD

VERIFICATION OF EXISTING PIPING SIZES AND LOCATION

WILL BE REQUIRED.

3 EXISTING FLOOR DRAIN AND ASSOCIATED WASTE AND

VENT TO REMAIN. MODIFY PIPING AS NEEDED TO MEET

CODE. IF P-TRAP AT EXISTING FLOOR DRAIN IS NOT

PRIMED, INSTALL NEW TRAP GUARD, TG.

4 ROUTE NEW 3" VENT TO CONNECT TO EXISTING VENT.

VERIFY EXISTING SIZE IS ADEQUATE PER CODE. FIELD

VERIFICATION OF EXISTING VENT PIPING SIZE AND

LOCATION WILL BE REQUIRED. IF A NEW VENT THROUGH

ROOF IS INSTALLED, SEE DETAIL B1/P-501.

5 EXTEND EXISTING HWR PIPE AND CONNECT TO 3/4" HW

LINE SERVING LAVATORIES IN PLUMBING CHASE. PROVIDE

BALANCING COCK IN HWR LINE IN CHASE AND PROVIDE

ACCESS PANEL IN WALL FOR ACCESS TO BALANCING

COCK. FIELD VERIFICATION OF EXISTING HWR PIPING

SIZES AND LOCATION WILL BE REQUIRED.

6 VERIFY IF NEW FLOOR CLEANOUTS ARE REQUIRED FOR

WASTE PIPING SERVING ROOMS 104A, 104B AND 104C. IF

REQUIRED, INSTALL PER DETAIL C1/P-501.

7 INSTALL WALL CLEANOUT AT URINAL AND LAVATORIES

AND AS REQUIRED BY CODE.

8 NEW FLOOR DRAIN, SEE DETAIL C4/P-501 AND INSTALL

WITH TRAP GUARD, TG.

9 WATER HAMMER ARRESTOR IN PLUMBING CHASE, SIZED

FOR NUMBER OF FIXTURES SERVED BY CW LINE. SEE

DETAIL B2/P-501.

A1

PLUMBING ISOMETRIC - WASTE & VENT

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

N

SCALE : 1/4" = 1'-0"

0' 2' 4' 8' 16'

A5

KEY PLANA3

PLUMBING ISOMETRIC - WATER

/0

/2

WYE FITTING

LENGTH TO SUIT

FLOW

EXISTING FINISHED FLOOR

CAULK AS REQUIRED

TOP OF CLEANOUT TO BE FLUSH

WITH FINISHED FLOOR

ADJUSTABLE FLOOR CLEANOUT

WITH INTERNAL BRONZE THREADED

PLUG AND SCORIATED COVER

SECURED TO PLUG WITH

COUNTERSUNK SCREW

BALANCE OF PIPING SAME AS

CLEANOUT TO GRADE

GROUTED PLUG IN WYE

FITTING OR 1/8 BEND IF

CLEANOUT OCCURS AT END

OF LINE

NOTES:

BLOWTHRU: DIMENSION A = GREATER OF 4" OR 1/2"

PLUS AC TOTAL PRESSURE IN INCHES WATER

COLUMN (WC)

DRAIN LINE SHALL BE INSULATED.

ROOF TOP UNIT DRAIN PAN

DRAIN LINE SHALL BE AT LEAST THE SAME

SIZE AS THE NIPPLE ON THE DRAIN PAN

CLEAN

OUT PLUG

DEPTH FOR SEAL,

SEE NOTE 1

SEE FLOOR PLANS

PITCH DOWN

TOWARD DRAIN

CLEAN

OUT PLUG

OPEN TO

ATMOSPHERE

UNION

CL

A

B

DRAWTHRU: DIMENSION B = GREATER OF 2" OR 1/2"

PLUS AC TOTAL PRESSURE IN INCHES WATER

COLUMN (WC)

OR

1.

2.

CLAMP TO 24"x24" 4# LEAD SHEET

AND WATERPROOFING

MEMBRANE (NOT REQUIRED FOR

SINGLE POUR CONSTRUCTION)

COATED CAST IRON FLOOR DRAIN

WITH ADJUSTABLE STRAINER,

DOUBLE DRAINAGE FLANGE AND

WEEP HOLES

EXISTING FINISHED FLOOR

CAULK AS REQUIRED

SUPPORT AT

THIS POINTCONCRETE FLOOR

OF TWO POUR

CONSTRUCTION

DEEP

SEAL "P"

TRAP

STAINLESS

STEEL CLAMP

ROOFING (SEE ARCH

FOR ROOF TYPE)

FASTEN & SEAL FULL

WIDTH OF FLANGE

OFFSET IN

CEILING WHERE

REQUIRED

PIPE SLEEVE

VENT PIPE

ESCUTCHEON

FOR EXPOSED

RISER

24" MIN. FROM ANY

WALL OR VERTICAL

SURFACE

24" MINIMUM

FOR SNOW LOAD

NEOPRENE

PIPE BOOT

SEALANT

UNION

BALL VALVE

HAMMER ARRESTOR

SEE PLAN FOR SIZE

FRAMED STAINLESS STEEL ACCESS

DOOR WITH CYLINDER LOCK AND

"HAMMER ARRESTOR" LABEL

12-32

1-11

FIXTURE UNITSMARK P.D.I. UNITS

WHA1

WHA

B

A

33-60WHA2 C

REMARKS

PROVIDE

ACCESS

DOOR5010

JR SMITH MODEL No.

1. WATER HAMMER ARRESTORS TO BE SIZED BASED ON QUANTITY OF

FIXTURE UNITS SERVED WITHIN A FIXTURE GROUP, AND TO HAVE

THREADED CONNECTION, STAINLESS STEEL 304 CASING AND BELLOWS.

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\P u b li c \D o c u m e n ts \H

A S

K E

L L

P

L U

M C

E N

T R

A L c a rn tz e n

.r v t

/5

/2

:2

:4

P

M

A s in d ic at ed

P-501

B L

D G

P

L U

M B

IN

G

D E

T A

IL

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

M T

B

C G

A

M T

B

P

7W P

-5

C1

FLOOR CLEANOUT DETAIL

C2

CONDENSATE DRAIN DETAIL

C4

FLOOR DRAIN DETAIL

B1

VENT THROUGH ROOF DETAIL

B2

WATER HAMMER ARRESTOR DETAIL

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

/0

/2

FD1

FLOOR DRAIN: ZURN Z-415, 6" ASSEMBLY WITH TYPE B STRAINER,

CAST IRON. PROVIDE WITH TRAP GUARD TG.

TG

TRAP GUARD BY J.R. SMITH MODEL No. 2692. SIZE TO MATCH DRAIN

SIZE. INSTALL PER MFG. REQUIREMENTS.

FCO

FLOOR CLEANOUT: SMITH 4223 CAST IRON BODY WITH GAS AND

WATERTIGHT BRONZE PLUG.

WCO:

WALL CLEANOUT: SMITH 4472 ROUND STAINLESS STEEL COVER

WITH BRONZE PLUG.

WC-WATER CLOSET:

AMERICAN STANDARD AFWALL "MILLENIUM" FLOWISE 1.28 GPF,

FLUSHOMETER TOILET SYSTEM, WALL-HUNG VITREOUS CHINA

WATER CLOSET WITH ELONGATED SIPHON JET ACTION BOWL

AND 1-1/2" TOP SPUD INLET AND MANUAL HIGH EFFICIENCY

FLUSH VALVE, MODEL 2856.128. PROVIDE WITH CHURCH

295CT WHITE OPEN FRONT ELONGATED SEAT LESS COVER,

J.R. SMITH CARRIER: FLOOR SUPPORTED, CONCEALED IN

WALL.

MFG: SMITH, WADE, JOSAM OR ZURN.

SUPPLY: MCGUIRE H166 STOP AND SUPPLY.

MOUNTING HEIGHT: HEIGHT AS INDICATED ON

ARCHITECTURAL DRAWINGS, OR AS SPECIFIED BY THE

ARCHITECT.

SERVICE REQUIREMENTS: 3" WASTE, 1" CW

WC1-WATER CLOSET (ADA COMPLIANT):

AMERICAN STANDARD AFWALL "MILLENIUM" FLOWISE 1.28 GPF,

FLUSHOMETER TOILET SYSTEM, WALL-HUNG VITREOUS CHINA

WATER CLOSET WITH ELONGATED SIPHON JET ACTION BOWL

AND 1-1/2" TOP SPUD INLET AND MANUAL HIGH EFFICIENCY

FLUSH VALVE, MODEL No. 2856.128. PROVIDE WITH CHURCH

295CT WHITE OPEN FRONT ELONGATED SEAT LESS COVER,

J.R. CARRIER: FLOOR SUPPORTED, CONCEALED IN WALL.

MFG: SMITH, WADE, JOSAM OR ZURN.

SUPPLY: MCGUIRE H166 STOP AND SUPPLY.

BARRIER FREE TOILET: MOUNTING HEIGHT: HEIGHT AS

INDICATED ON ARCHITECTURAL DRAWINGS, OR AS SPECIFIED

BY THE ARCHITECT.

SERVICE REQUIREMENTS: 3" WASTE, 1" CW

U1, URINAL (ADA COMPLIANT):

AMERICAN STANDARD WASHBROOK FLOWISE 0.125 GPF

ULTRA HIGH EFFICIENCY URINAL SYSTEM, WALL HUNG,

VITREOUS CHINA, WASHOUT FLUSH ACTION, SENSOR-

OPERATED FLUSHOMETER VALVE AND URINAL SYSTEM,

MODEL No. 6590.525 WITH FACTORY-INSTALLED 6V LITHIUM

BATTERY AND LOW BATTERY INDICATOR.

CARRIER: FLOOR SUPPORTED, CONCEALED IN WALL.

MFG: SMITH, WADE, JOSAM OR ZURN.

MOUNTING HEIGHT: HEIGHT AS INDICATED ON

ARCHITECTURAL DRAWINGS, OR AS SPECIFIED BY THE

ARCHITECT.

SERVICE REQUIREMENTS: 2" WASTE, 3/4" CW

L1, LAVATORY (ADA COMPLIANT):

TYPE: WALL-HUNG, VITREOUS CHINA

MFG: AMERICAN STANDARD MODEL 0356.012 "LUCERNE"

FAUCET: DELTA FAUCET MODEL No. 2529LF-LGHGMHDF WITH

SOLID BRASS BODY, 4" CENTERSET, WITH WRISTBLADE

HANDLES, VANDAL RESISTANT 0.5 GPM SPRAY OUTLET AND

METAL GRID STRAINER.

SUPPLIES: 1/2" COMPRESSION ANGLE BALL VALVE STOPS

WITH 16" BRAIDED STAINLESS STEEL RISERS. CHROME

PLATED.

TAILPIECE: 1-1/4" IN X 1-1/2" OUT, 17 GA, CHROME PLATED,

ADJUSTABLE.

CARRIER: FLOOR SUPPORTED, CONCEALED IN WALL WITH

CONCEALED ARMS.

MFG: SMITH, WADE, JOSAM OR ZURN.

MOUNTING HEIGHT: HEIGHT AS INDICATED ON

ARCHITECTURAL DRAWINGS, OR AS SPECIFIED BY THE

ARCHITECT.

NOTE: HOT WATER SUPPLY LINE AND WASTE SHALL BE

INSULATED WITH TRUEBRO T101W KIT. SEE ARCHITECTURAL

FOR MOUNTING HEIGHT.

SERVICE REQUIREMENTS: 1-1/2" WASTE, 1-1/2" VENT, 1/2" CW

AND 1/2" HW.

MB, MOP BASIN

TYPE: FLOOR MOUNT, MOLDED STONE BY FIAT MODEL No.

TSBC1611, 32"x32"x12" DEEP, WITH STAINLESS STEEL CAP ON

THRESHOLD ONLY. DRAIN BODY IS STAINLESS STEEL CAST

INTEGRALLY AND A WITH A STAINLESS STEEL STRAINER.

PROVIDE WITH No. 832AA HOSE AND HOSE BRACKET, No.

833AA SILICONE SEALANT AND No. MSG STAINLESS STEEL

WALL GUARDS (TWO PANELS).

FAUCET: CHICAGO FAUCET MODEL No. 897-CCP WALL-MOUNT, 8" BODY, ADJUSTABLE ARMS, VANDAL PROOF LEVER

HANDLES, WITH ATMOSPHERIC VACUUM BREAKER SPOUT,

PAIL HOOK AND WALL BRACE.

SERVICE REQUIREMENTS: 3" WASTE, 2" VENT, 1/2" CW AND

1/2" HW.

MARK

WC & WC1

U1

L1 LAVATORY

URINAL, FLUSHVALVE

WATER CLOSET, FLUSHVALVE

DESCRIPTION

MINIMUM INDIVIDUAL CONNECTIONS (IN)

WASTE

VENT

CW HW

2 2 3/4 -

1/21/21-1/21-1/2

REMARKS

FD1 FLOOR DRAIN -2 -1-1/2

MB MOP BASIN 1/21/223

SHEET NUMBER

D E

S

IG

N E

D

D R

A W

N

C H

E C

K E

D

D

A T

E R

E M

A R

K S

IS

S

U E

D A

T E

S U

B M

IT

T

A L

D R

A W

IN

G

S C

A L E

D R

A W

IN

G

F

IL

E N

A M

E P

R O

JE

C

T N

U M

B E

R

M A

N A

G E

M E

N T

R E

V

IS

IO

N

S

A D

D E

N D

U M

S

C

U s e rs

\P u b li c \D o c u m e n ts \H

A S

K E

L L

P

L U

M C

E N

T R

A L c a rn tz e n

.r v t

/5

/2

:2

:4

P

M

2"

'-0

P-601

B L

D G

P

L U

M B

IN

G

S C

H E

D U

L E

S

H A

S K

E L

L

IN

D

IA

N N

A T

IO

N

S U

N

IV

E R

S

IT

Y

B U

IL

D

IN

G

R

O O

M

L

E C

T U

R E

H A

L L

P

7W

M T

B

C G

A

M T

B

P

7W P

-6

WASTE DEVICES

FIXTURE SCHEDULE

PLUMBING FIXTURE PIPE CONNECTION SCHEDULE

A m e ri c a s P k w y N

E S u it e

A lb q u e rq u e N

M

-2 -0

F a x

-2

-4 w w w .w h p a c ifi c .c o m

/0

/2

GENERAL HVAC DUCTWORK NOTES

(APPLICABLE TO ALL DUCTWORK DRAWINGS)

A. PRODUCTS, MANUFACTURERS, AND MODEL NUMBERS FOR

EQUIPMENT INDICATE A BASIS FOR DESIGN AND ARE NOT LIMITED

TO THE PRODUCTS SPECIFIED. SUBSTITUTION OF PRODUCTS MUST

COMPLY OR EXCEED THE REQUIREMENTS DESIGNATED IN THE

SPECIFICATIONS AND DRAWINGS.

B. CONCRETE HOUSEKEEPING PADS AT MECHANICAL EQUIPMENT

SHALL BE A MINIMUM OF 6" THICK AND A MINIMUM OF 6" LARGER

THAN THE MECHANICAL EQUIPMENT.

C. ALL DUCT SIZES SHOWN ON THE DRAWINGS ARE CLEAR INSIDE

DIMENSIONS.

D. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT SIZE, LOCATION,

AND MOUNTING HEIGHT OF ALL LOUVERS.

E. MOUNT ROOM THERMOSTATS AND TEMPERATURE SENSORS

WHERE INDICATED ON PLANS, AT 48 IN. A.F.F. UNLESS NOTED

OTHERWISE.

F. PROVIDE MANUAL BALANCING DAMPERS ON BRANCH DUCT FOR

ALL AIR OUTLETS, INLETS AND DEVICES.

G. PLANS SHOW AIR DEVICES IN COORDINATION WITH REFLECTED

CEILING PLANS. VERIFY CEILING TYPES BEFORE ORDERING AIR

DEVICES.

H. REFER TO REFLECTED CEILING PLANS FOR EXACT LOCATION OF AIR

DEVICES.

I. WHERE CEILING SPACE IS USED AS A RETURN AIR PLENUM AND

WALLS EXTEND TO DECK, PLANS SHOW SIZE OF OPENINGS.

J. USE NO MORE THAN 5 FT OF FLEXIBLE DUCT LENGTHS AT

CONNECTION TO AIR TERMINALS. ALL OTHER DUCTWORK SHALL BE

PER SPECIFICATIONS.

K. SEE DUCT SPECIFICATIONS FOR SPECIFIC AND GENERAL

MATERIALS AND REQUIREMENTS.

L. ALL RECTANGULAR SQUARE ELBOWS SHALL BE PROVIDED WITH

INTERNAL TURNING VANES.

M. VERIFY ACTUAL CONDITIONS ON SITE BEFORE BID.

N. IN HARD CEILINGS AND WALLS, PROVIDE 30"x30" ACCESS PANELS

FOR ALL ISOLATION VALVES, FIRE/SMOKE DAMPERS, BALANCING

DAMPERS, CONTROL DEVICES, AND ALL OTHER DEVICES THAT

REQUIRE MAINTENANCE.

O. ALL MATERIALS ON PLANS ARE NEW, UNLESS INDICATED

OTHERWISE.

P. INSTALL FLEXIBLE DUCT CONNECTIONS BETWEEN DUCTWORK AND

ANY EQUIPMENT CONTAINING A MOTOR (NO EXCEPTIONS).

Q. WITHOUT EXCEPTION, ELIMINATION OF ANY PIPING INSULATION FOR

HANGERS IS NOT ACCEPTABLE. PROVIDE INSERTS, AS SPECIFIED,

FOR THE PLACEMENT OF PIPING SUPPORT. CRUSHING OF

INSULATION IS NOT ACCEPTABLE. SEE SPECIFICATIONS.

R. FOR ALL PIPING LOCATED OUTSIDE BUILDING, PROVIDE ALUMINUM

JACKET OVER WATERPROOFED INSULATION.

S. WHERE CONFLICTS OCCUR BETWEEN THE CONTRACT DRAWINGS,

SPECIFICATIONS, FIELD CONDITIONS AND/OR THE BUILDING CODE,

THE MOST STRINGENT REQUIREMENTS SHALL APPLY, IN THE SOLE

JUDGMENT OF THE ARCHITECT/ENGINEER.

T. DRAWINGS ARE CONSIDERED SCHEMATIC IN NATURE. PROVIDE

REQUIRED FITTINGS AND OFFSETS FOR A COMPLETELY

OPERATIONAL SYSTEM.

U. FIRE/SMOKE DAMPERS SHALL BE 120V WITH DUCT INTEGRAL

SMOKE DETECTORS, WIRED AND MONITORED BY DIV. 26.

V. PROVIDE INSULATED BASE OF THERMOSTATS LOCATED ON

EXT…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .