A06 EDIS Potting shed roof plan_r1.pdf

PDF 223 KB Posted

Attached to
EDIS: REPLACE FLAT ROOF Federal contract opportunity
Solicitation number
140P4520R0025
Issued by
Department of the Interior National Park Service

View the file

Other files for this federal contract opportunity

Other files attached to EDIS: REPLACE FLAT ROOF, newest first.
File Type Posted
Sol_140P4520R0025_Amd_0002.pdf PDF
Sol_140P4520R0025_Amd_0001.pdf PDF
B03 Wage Rates NJ20200031.pdf PDF
B08 EDIS FLAT ROOF PRICE SCHEDULE.pdf PDF
References Worksheet (1) (1).doc DOC document
A06 Building photos for Solicitation.pdf PDF
B03 Wage Rates NJ20200002.pdf PDF
Sol_140P4520R0025.pdf PDF
A04 Binder for PR 4-8-20.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

wmachurat Text Box

U.S. DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

NORTHEAST REGION

Historic Architecture, Conservation, and Engineering Center (HACE)

WBM

wmachurat Text Box 4-1-20 wmachurat Text Box A1 wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Text Box

ROOF PLAN

GARDENER'S COTTAGE AND POTTING SHED

THOMAS EDISON NATIONAL HISTORICAL PARK

wmachurat Line wmachurat Line wmachurat Line wmachurat Line wmachurat Line wmachurat Line wmachurat Text Box wmachurat Text Box 38'-0" +/-wmachurat Text Box 38'-0" +/-wmachurat Text Box

ROOF N.I.C

wmachurat Text Box

ROOF N.I.C

wmachurat Text Box

ROOF N.I.C

wmachurat Text Box

ROOF N.I.C

wmachurat Text Box

GENERAL NOTES

wmachurat

VERIFY ALL CONDITIONS AND DIMENSIONS IN FIELD.

PATCH & REPAIR AN ESTIMATED QUANTITY OF 500 SQUARE FEET X 1" DEEP OF DETERIORATED CONCRETE ROOF DECK.

1.

wmachurat Text Box 2.

wmachurat Text Box

DRAWING KEY NOTES

wmachurat Text Box REMOVE AND PROPERLY DISPOSE OF ALL EXISTING ASPHALT BUILIT-UP ROOFING, UNDERLAYMENTS, FLASHINGS AND ACCESSORIES TO FULLY EXPOSE CONCRETE DECK AND FACE OF PARAPET WALLS; PATCH AREAS OF DETERIORATED CONCRETE WALL AND ROOF DECK; INSTALL RIGID INSULATION BOARD ADHERED TO THE CONCRETE DECK; INSTALL PLYWOOD UNDERLAYMENT MECHANICALLY FASTENED TO THE INSIDE FACE OF PARAPET WALLS; INSTALL FULLY-ADHERED EPDM MEMBRANE ROOFING SYSTEM AT ROOF AND PARAPET WALLS.

REMOVE ASPHALTIC MASTIC FROM ALL FACES OF CHIMNEY APPROX. 6'-0" WIDE X 4'-0" DEEP X 6'-0" HEIGHT. REMOVE EXISTING METAL COUNTER FLASHING. INSTALL NEW EPDM MEMBRANE BASE FLASHING AND NEW METAL COUNTER FLASHING AT FOUR SIDES OF CHIMNEY.

REMOVE EXISTING METAL PARAPET WALL CAP FLASHING AND WOOD BLOCKING; INSTALL NEW PARAPET CAP FLASHING AND CONTINUOUS WOOD BLOCKING.

PROVIDE NEW METAL VENT-THRU ROOF FLASHING AND EPDM BASE FLASHING (5) LOCATIONS.

TEMPORARILY REMOVE AND SALVAGE ROOF HATCH, INSTALL NEW WOOD CURB AND EPDM FLASHING AND REINSTALL EXISTING ROOF HATCH.

REMOVE & REPLACE EXISTING METAL CHIMNEY CAP, TOP SECTION OF METAL FLUE AND CONICAL FLUE CAP.

PROVIDE METAL BASE FLASHING AND NEW ROOF DRAIN AT EXISTING 3" DIAMETER DRAIN OPENING (NO EXISTING ROOF DRAIN IN PLACE).

PROVIDE EPDM FLASHING AND COUNTER FLASHING CONTINUOUS AT EXISTING CONCRETE CURB (3 SIDE OF ROOF); CURB HEIGHT VARIES 6" TO 1'-0" +/- X 6" WIDE.

PROVIDE PEDESTRIAN OVERHEAD PROTECTION SCAFFOLDING 8'-0" WIDE X 8'-0" LONG X 10'-0" HEIGHT AT EXTERIOR ENTRY DOORS.

wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Text Box wmachurat Callout wmachurat Callout wmachurat Arrow wmachurat Line wmachurat Callout wmachurat Callout wmachurat Callout wmachurat Arrow wmachurat Callout wmachurat Callout wmachurat Callout wmachurat Callout wmachurat Callout wmachurat Callout wmachurat Text Box wmachurat Text Box wmachurat Callout wmachurat Callout wmachurat