A04_Wells_SEAT_BAse_Air_Ops_Mobile_Office_SOW.pdf

PDF 202 KB Posted

Attached to
SEAT Base Mobile Office Federal contract opportunity
Solicitation number
140L3924Q0142
Issued by
Department of the Interior Bureau of Land Management Nevada Region

About this file

This document is a Statement of Work (SOW) for a mobile office structure to accommodate fire and aviation program personnel at the Bureau of Land Management (BLM) Elko District SEAT Base in Wells, Nevada. The mobile office must be made of metal, at least 16' wide x 40' long, and contain four office spaces and a conference room. It must include specific features such as insulation, HVAC, electrical, lighting, data ports, and paint/finish requirements. The desired delivery date is mid-March 2025, and the office will be shipped to the Wells Airport SEAT Base location. This SOW is related to a federal contract opportunity with Solicitation Number 140L3924Q0142 for a SEAT Base Mobile Office, issued by the Department of the Interior Bureau of Land Management Nevada Region.

View the file

Other files for this federal contract opportunity

Other files attached to SEAT Base Mobile Office, newest first.
File Type Posted
Sol_140L3924Q0142_Amd_0001.pdf PDF
B09_Wells_SEAT_Base_Questiona_and_Answers_with_Site_Plan_0001.pdf PDF
Sol_140L3924Q0142.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work

BLM—Elko District Wells SEAT Base Air Operations Office Space with Conference Room

The BLM-Elko District would like to purchase a mobile office structure for the purpose of accommodating and providing workspace for fire and aviation program personnel in Wells, NV.

The office structure must be made from metal (such as seatrain, Conex container, shipping containers) for durability. This mobile office space will likely remain at the Wells SEAT Base located at the Wells, NV Airport indefinitely.

Requirements:

• Entire structure should be a minimum of 16’ wide X 40’ long (New is preferred but would entertain gently used unit if it has like-new appearance once assembled).

• Exterior finish including all doors needs to be painted light tan with a rust inhibiting UV resistant paint.

• Must contain 4 office spaces 11’ 6” X 8’ (92 sq. ft.) and a conference room at least 17’ X

16’ (272 sq. ft.).

• Each office must have a door with lock.

• Must have 1 total - 36” exterior entry door that swings outward. The door must be industrial grade, door jamb must be constructed out of steel, lockable doorknob, lockable dead bolt, door closer and sweep, and painted to match the exterior. (See schematic for location)

• Must have 6 total 36”x36” horizontal sliding glass windows. Glass must be tempered, window frames constructed out of aluminum, and window jamb to be constructed out of steel. (See schematic for location)

• The container must have interior mounted insulation with a minimum insulation rating of R-11 in the walls and roof.

• The office space must include an industrial grade Air Condition / Heater Unit that is rated to service the size of the building to keep interior at a comfortable temperature. The unit must be securely fastened to the exterior. The unit must have ducting for even cooling/heating in all rooms and controlled by an interior wall mounted thermostat located in the conference room.

• All interior walls and ceiling need to be smoothly finished with sheetrock and painted with semi-gloss white paint.

• All floors must be commercial grade vinyl plank flooring.

• Must include painted door trim (tan in color) and matching vinyl baseboard molding throughout the container where appropriate.

• All electrical outlets, lights, and air handling units must terminate into an interior mounted 125 AMP-120/240VAC electrical sub-panel.

• The container must have 2 total – 120VAC waterproof exterior GFI power receptacles located near each exterior entry door.

• Must have a total of 12 - 120VAC interior duplex GFI receptacles all of which are mounted on exterior walls. (2 per office and 4 in the conference room)

• The container must have 2 total exterior lighting fixtures mounted above each entry door.

Statement of Work

• Must have a total of 12 – ceiling mounted 48-inch 4 bulb fluorescent light fixtures. (2 per office and 4 in the conference room)

• Must have a total of 12 equally spaced network ports (CAT6) connected to a single data box mounted on the interior wall near the electrical sub-panel. (2 per office and 4 in the conference room)

• Delivery and setup must be included.

• Electrician is required to wire units to an existing disconnect (may be subcontracted).

• Ground at placement site is level and should not need any engineering.

• Desired delivery date of mid-March 2025.

Units to be shipped to:

Wells Airport SEAT Base 1550 Hwy 93 North Wells, NV 89835

36”x36”Window

Electrical Panel

11’ 6” x 8’ Office

16’ x 17’ Conference Room

48” 4‐Bulb Light

36”x36”Window

36”x36”Window36”x36”Window 36”x36”Window

36”x36”Window

11’ 6” x 8’ Office

11’ 6” x 8’ Office

11’ 6” x 8’ Office

36”x80” door

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

48” 4‐Bulb Light

8’

16’

11’ 6”

40’

17’

36”x80” door

36”x80” door

36”x80” door

36”x80” door

5’ 8”

15’

7’

20’

File details come from the government source that posted it. Updated .